Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Uncertainty Quantification in GADRAS Inverse Modeling

The Gamma Detector Response and Analysis Software (GADRAS) package includes an inverse modeling tool that is helpful in identifying characteristics of unknown radioactive materials. Traditionally, uncertainties in this analysis were derived solely from measurement data quality and the fit of synthetic spectra. This paper aims to rigorously quantify additional sources of uncertainty, focusing on uncertainties arising from measurements being analyzed, Detector Response Function (DRF) characterization, and DRF extrapolation. Applying these findings to the BeRPBall benchmark data set, we demonstrated the impact of these uncertainties on plutonium and polyethylene estimates. The results underscore the importance of incorporating diverse uncertainty sources to enhance the accuracy and reliability of GADRAS’s inverse modeling capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Special Nuclear Geometric Modeling

This report is a summary of our summer interns project that focused on investigating the usefulness of the Gamma Detector Response and Analysis Software (GADRAS) into the Material Control & Accountability (MC&A) Measurements Team. The project's findings highlight the advantages of using GADRAS and demonstrate its value in improving the MC&A Measurements Team's analytical capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Behavioral Robotics Approach to Radiation Mapping Using Adaptive Sampling

Radiation mapping is a desirable task to automate because of the inherent risks involved and its tedious nature. A novel system was designed to address this by combining various existing technologies, utilizing behavior-based robotics and Bayesian optimization. The system uses a quadruped robot equipped with a manipulator and gamma detector to take measurements at locations that are selected based on the uncertainty of a surrogate model used to estimate the true radiation field. The robot uses input from the world with depth cameras to avoid collisions with the robot’s body, and unreachable points for the end effector are addressed by both allowing for a soft collision with the environment to occur, prompting the system to abandon that point, and varying the exploration tendency of the optimization based on consecutive collisions. This approach provides unique traversability and adaptability over other strategies in the literature. Experiments were performed by placing a Cesium-137 source on the ground and varying geometric setups and an optimization parameter demonstrating the adaptability to diverse environments and the increased robustness resulting from the designed behavior. The results additionally demonstrate that dynamically adjusting the optimization algorithm’s exploration tendency based on the arm’s collision history improves the system’s ability to navigate cluttered environments and construct accurate radiation maps without getting stuck in unreachable areas.

Adams, Joel↗

A Tool Kit for Generating Simulated Radiation Measurements for Advanced Reactor Safeguards and Security

A tool kit was developed to simulate and analyze passive radiation measurements of molten salt reactor (MSR) operations to support development of nuclear safeguards approaches for this emerging reactor technology. A Transient Simulation Framework of Reconfigurable Modules (TRANSFORM) multiphysics simulation of an MSR produces time-dependent isotopic inventories at user-selected locations within the model. The tool kit implements the Gamma Detector Response and Analysis Software (GADRAS) application programming interface to inject the TRANSFORM isotopic inventories extracted/processed by a Python pipeline into GADRAS models of user-defined geometries. The TRANSFORM inventories are the source terms used to obtain synthetic measurements from GADRAS-defined detectors. The speed of TRANSFORM and GADRAS simulations enables surveying the large design space of MSRs (e.g., fuel type, fuel salt composition, number of loops) and the plethora of measurements (e.g., location, detector type, and collimation) within the reactor. This has enabled timely assessment of the various measurement locations and detectors to identify the most effective and efficient safeguards approach for a specific MSR design. Lastly, the tool kit also simulates extracted samples that can be aged to a desired dose, enabling stakeholders to optimize a measurement plan to use sample analysis as an element within a broader material accountancy plan.

Westphal, Greg↗

Simulation of Isotopic Concentrations and Gamma Spectra from Dynamic Fission Sources

A tool was developed to rapidly generate synthetic gamma-ray spectra to evaluate safeguards material control and accounting methods for liquid-fueled molten salt reactors. Molten salt reactor operations pose unique challenges to nuclear safeguards methods and protocols compared to deployed reactors designs (e.g., light water reactors). This research evaluates the use of gamma-ray spectroscopy to monitor fission product isotopic flow through a reactor model to understand expected operations and investigate changes to the spectra with material diversion scenarios. The large design space of molten salt reactors (e.g., liquid-fueled, liquid-cooled, online separations) could potentially lead to many measurement points within the reactor system. The developed analytical tool generates and evaluates synthetic gamma-ray spectra from dynamic reactor simulations by extracting isotopic inventory to generate source terms. An implementation in the Gamma Detector Response and Analysis Software (GADRAS) Application Program Interface (API) uses the source terms, a model of the reactor component, a detector response function, and measurement plan to quickly generate and analyze spectra. Prospective measurements are then evaluated in the more accurate but slower Geant4 simulations. Utilization of the developed modeling tool and analysis of the subsequent spectra enables optimization of collimation, shielding requirements, and expected count rates that are used to determine key measurement points in the modeled reactor design.

O'Brien, Sean↗

Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Compton scattering↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of Selenium in CdZnTeSe as a Defect Engineering Agent

Cadmium zinc telluride (CdZnTe) with 10 atomic % Zn has been the material of choice for room-temperature semiconductor compact X- and gamma-ray detector applications for over three decades. Despite its commercial success as the most desirable room-temperature semiconductor radiation detection material, CdZnTe (CZT) suffers from a lack of compositional homogeneity on both the micro- and macroscales and the presence of high concentrations of performance-limiting defects such as subgrain boundary networks (dislocation walls) and secondary phases (Te-rich inclusions). Random distributions of these defects in the CZT matrix result in the spatial inhomogeneity of the material’s charge-transport properties. The recently discovered quaternary Cd x Zn 1-x Te 1-y Se y (CZTS) has experienced remarkable advances in its material properties, with highly reduced defects and higher compositional homogeneity. This book chapter focuses on the presence of performance-limiting defects in CZT that have thus far hindered the yield and cost of high-quality detectors and restricted their widespread deployment for a variety of potential applications, particularly for their use as large-volume gamma detectors, where the demands on material perfection are significantly greater. This chapter also provides an overview of the recent developments in the quaternary material CZTS, particularly the effects of selenium (Se) in the CZTS matrix on the defect engineering of the quaternary alloy material and the advancement of CZTS as a potential next-generation detector operable at room temperature.

Roy, Utpal N.↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of selenium in CdZnTeSe quaternary compound for radiation detector applications

X- and gamma-ray detectors are increasingly becoming essential tool for science and technology in various fields include homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. Cd 1-x Zn x Te 1-y Se y (CZTS) is emerging as a next-generation compound semiconductor for such applications. CZTS was found to possesses a very low concentration of Te inclusions and free from sub-grain boundary networks. Being a quaternary compound with varying alloy composition, optimization of the composition was performed to determine the minimum amount of selenium required to produce CZTS with reduced defects. The optimized composition was found to be x=0.10 and y=0.02, i.e., Cd 0.9 Zn0.1Te 0.98 Se 0.02 , for excellent material properties as a radiation detector. The resulting material was free from sub-grain boundary networks and with a highly reduced concentration of Te inclusions. The bulk dark resistivity obtained was in the range of 1-3x1010 ohm-cm with the highest achieved mobility-lifetime product of ~6.6x10-3 cm2/V for the optimized CZTS composition. Impurity analyses were performed by the Glow Discharge Mass Spectroscopy (GDMS) technique, and the results showed relatively high impurity concentrations compared to commercial detector-grade CdZnTe. Thus, CZTS has room for further improvement with additional purification of the starting materials.

36 MATERIALS SCIENCE↗

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-energy Electron-track Imaging for a Liquid Argon Time-projection-chamber Telescope Concept Using Probabilistic Deep Learning

The GammaTPC is an MeV-scale single-phase liquid argon time-projection-chamber gamma-ray telescope concept with a novel dual-scale pixel-based charge-readout system. It promises to enable a significant improvement in sensitivity to MeV-scale gamma rays over previous telescopes. The novel pixel-based charge readout allows for imaging of the tracks of electrons scattered by Compton interactions of incident gamma rays. The two primary contributors to the accuracy of a Compton telescope in reconstructing an incident gamma-ray’s original direction are its energy and position resolution. In this work, we focus on using deep learning to optimize the reconstruction of the initial position and direction of electrons scattered in Compton interactions, including using probabilistic models to estimate predictive uncertainty. We show that the deep-learning models are able to predict locations of Compton scatters of MeV-scale gamma rays from simulated 500 μm pixel-based data to better than 1 mm rms error and are sensitive to the initial direction of the scattered electron. We compare and contrast different deep-learning uncertainty estimation algorithms for reconstruction applications. Additionally, we show that event-by-event estimates of the uncertainty of the locations of the Compton scatters can be used to select those events that were reconstructed most accurately, leading to improvement in locating the origin of gamma-ray sources on the sky.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗

Pixel Array Germanium Detectors for Nuclear Physics (Final Technical Report)

The Department of Energy (DOE) Office of Nuclear Physics supports the development and maintenance of germanium gamma-ray detector arrays at national laboratories and universities. Germanium gamma-ray detectors provide state-of-the-art gamma-ray energy resolution, making them critical for gamma-ray and x-ray spectroscopy in Nuclear Physics. Furthermore, detector segmentation and charge-signal waveform processing enables 3-dimensional (3D) measurement of gamma-ray interaction locations needed for the highest-fidelity Nuclear Physics experiments. Attaining and maintaining excellent gamma-ray energy resolution depends largely on the naturally excellent charge-collection properties of germanium crystals. However, the optimal method for achieving the best practical 3D spatial resolution within the detector volume at high counting rates is less clear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗