Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and Quantification of Beta-Emitters in Waste Packages by Segmented Gamma-Scanning - 20114

A commonly applied method for the non-destructive characterization of the radioactive inventory of waste packages (e.g. 200-l drums) is segmented gamma-scanning. The gamma-emitting inventory is identified via their characteristic lines in the measured spectra. The corresponding net peak areas allow for quantification applying appropriate models. The identification and quantification of beta-emitters present in the waste package require further evaluation. While some of them emit gamma-rays, too, which can be used for identification and quantification, pure beta-emitters contribute to the gamma-spectra only by their Bremsstrahlung-spectra. {sup 32}P, {sup 90}Sr and {sup 90}Y are typical representatives of these isotopes. A method is developed for identification and quantification of these pure beta-emitters in radioactive waste packages. Origin of the procedure is the evaluation of the measured gamma-spectrum. After the identification of all lines present in the spectrum (characteristic gamma-lines, single- and double-escape-lines, X-ray-lines, annihilation peak etc.) this information is used together with calibration data of the detection system and further a-priori information like matrix composition, cross-section data from databases etc. to simulate the spectra without the Bremsstrahlung-components by an appropriate method. This may be Monte Carlo simulations or, like in our case, a computer code taking into account mathematical descriptions of the physical effects like photo effect, (multiple) Compton scattering, backscattering etc. and the attenuation effects of the waste matrix. In any case, the resulting spectrum must simulate the real spectrum without its Bremsstrahlung-component as good as possible. Subtracting the simulated from the measured spectrum then results in the Bremsstrahlung-components caused by the beta-emitters. Prior to evaluation, a set of Bremsstrahlung-spectra is calculated and stored for different beta-emitters in different matrices using the Bethe-Heitler equation. This data set can be extended for new conditions, if necessary, and is allocated in a data base for future application. Applying a non-linear optimization using the generalized reduced gradient method for comparing the calculated with the derived Bremsstrahlung-spectra results in the identification of the beta-emitter and a factor, which is proportional to its activity. The proportionality is determined by previous calibration measurements. The application of the method is demonstrated by measurements on a 200-l mock-up drum and a real waste package. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$\gamma$-to-neutron branching ratio for deuterium-tritium fusion determined using high-energy-density plasmas and a fused silica Cherenkov detector

A fused silica Cherenkov detector was used to measure deuterium-tritium (DT) gammas during a set of 52 direct-drive cryogenic experiments performed at OMEGA. The detector was calibrated using the 4.4 MeV$\gamma$ from the first-excited state of carbon, which is produced when 14-MeV DT neutrons impinge upon a carbon puck. An approximate DT $\gamma$ spectrum as well as neutron yields from a standard neutron time-of-flight detector at OMEGA were used to calculate a DT $\gamma$-to-neutron branching ratio of (8.42 ± 2.84 ) x 10 -5 . Assuming an excited-state to ground-state ratio of 2.1:1, the measurement detailed in this work results in an approximate ground state only$\gamma$-to-neutron branching ratio of 2.72 x 10 -5 . So, this value is somewhat lower than accelerator-based measurements of the ground-state DT $\gamma$ only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance simulation of the soft gamma-ray concentrator

The soft gamma-ray concentrator is a telescope mission concept utilizing a suitable arrangement of bent multilayer structures of alternating low- and high-density materials. This lens is able to channel gamma-ray photons via total external reflection and concentrate the incident radiation to a point. The channeling technique offers the potential for concentrating gamma rays with focal lengths <10 m and energies >100 keV, beyond the reach of current grazing-incidence hard x-ray mirrors. For the performance estimation of such an instrument, we have developed a flexible set of computer modeling tools to compute the optical properties of multilayer structures, predict the channeling efficiency for a given multilayer configuration, and aid in the optimization of potential gamma-ray concentrator-based telescope designs. This modeling includes the multilayer optical properties calculated by the IMD software, the ray tracing using an IDL code, and the focal plane detector simulation by MEGAlib. We illustrate the potential of this approach by presenting simulated astronomical observations from a balloon-borne platform. The final result, including simulated effective area, instrument sensitivity, and polarization performance, shows that the gamma-ray concentrator will provide greatly increased sensitivity for next-generation soft gamma-ray missions with modest cost and complexity.

47 OTHER INSTRUMENTATION↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma-Ray Emission from Galaxies Hosting Molecular Outflows

Many star-forming galaxies and those hosting active galactic nuclei show evidence of massive outflows of material in a variety of phases including ionized, neutral atomic, and molecular. Molecular outflows in particular have been the focus of recent interest as they may be responsible for removing gas from the galaxy, thereby suppressing star formation. As material is ejected from the cores of galaxies, interactions of the outflowing material with the interstellar medium can accelerate cosmic rays and produce high-energy gamma rays. In this work, we search for gamma-ray emission from a sample of local galaxies known to host molecular outflows using data collected by the Fermi Large Area Telescope. We employ a stacking technique in order to search for and characterize the average gamma-ray emission properties of the sample. Gamma-ray emission is detected from the galaxies in our sample at the 4.4σ level with a power-law photon index of Γ ≈ 2 in the 1–800 GeV energy range. The emission is found to correlate with tracers of star formation activity, namely the 8–1000 μm infrared luminosity. We also find that the observed signal can be predominantly attributed to H II galaxies hosting energy-driven outflows. While we do not find evidence suggesting that the outflows are accelerating charged particles directly, galaxies with molecular outflows may produce more gamma rays than galaxies without outflows. In particular, the set consisting of gamma-ray-detected galaxies with molecular outflows are nearly perfect calorimeters and may be future targets for searches of high-energy neutrinos.

79 ASTRONOMY AND ASTROPHYSICS↗

Fermi-LAT Gamma-Ray Emission Discovered from the Composite Supernova Remnant B0453-685 in the Large Magellanic Cloud

Abstract We report the second extragalactic pulsar wind nebula (PWN) to be detected in the megaelectronvolt–gigaelectronvolt band by the Fermi-LAT, located within the Large Magellanic Cloud. The only other known PWN to emit in the Fermi band outside of the Milky Way is N157B, which lies to the west of the newly detected gamma-ray emission at an angular distance of 4°. Faint, pointlike gamma-ray emission is discovered at the location of the composite supernova remnant (SNR) B0453-685 with a ∼4 σ significance with energies ranging from 300 MeV–2 TeV. We present the Fermi-LAT data analysis of the new gamma-ray source, coupled with a detailed multiwavelength investigation to understand the nature of the observed emission. Combining the observed characteristics of the SNR and the physical implications from broadband modeling, we argue it is unlikely that the SNR is responsible for the gamma-ray emission. While the gamma-ray emission is too faint for a pulsation search, we try to distinguish between any pulsar and PWN component of SNR B0453-685 that could be responsible for the observed gamma-ray emission using semi-analytic models. We determine the most likely scenario is that the old PWN ( τ ∼ 14,000 yr) within B0453-685 has been impacted by the return of the SNR reverse shock with a possible substantial pulsar component below 5 GeV.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗

Evaluation of the Prompt Fission Gamma Properties for Neutron Induced Fission of 235,238 U and 239 Pu

Herein we present details of the prompt fission gamma property evaluations included in the released ENDF/B-VIII.0 files. The average prompt gamma multiplicity, the average prompt gamma spectrum, the average total prompt gamma energy released and the prompt gamma multiplicity distributions, included in the ENDF/B-VIII.0 files, are presented for 235 U(n,f), 238 U(n,f), and 239 Pu(n,f) reactions, as a function of incident neutron energy up to 30 MeV. The evaluation is based on available experimental data and model calculations. Notable data include recent measurements by experimental groups at Los Alamos and Lawrence Livermore National Laboratories, at Geel and Budapest, at CEA labs, as well as seminal historical gamma production measurements by Drake at Los Alamos.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗

Compatibility of ethylene vinyl acetate (EVA)/ethylene vinyl alcohol (EVOH)/EVA films with gamma, electron-beam, and X-ray irradiation

Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report to NCSP on 2008 DANCE measurements of 233 U($\eta$,$\gamma$)

Uranium-233 plays an important role in the Th-U fuel cycle, with substantial production in the cycle. This cycle has been proposed as an alternative to the U-Pu fuel cycle due to its reduced production of transuranic elements. An accurate measurement of the 233 U($\eta$,$\gamma$) cross section is required by the National Criticality Safety Program (NCSP) to complete the neutron-induced cross section data, where experimental capture cross section data are scarce and were measured decades ago. The most recent capture cross section data available in the literature were measured in 2007 at the n_TOF facility (CERN); in the 60s measurements were performed at Rensselaer Polytechnic Institute (RPI) and at LANL. Finally, as reported by ORNL, a new evaluation with a revised (renormalized) fission cross section is needed on 233 U. The challenge for this measurement lies in the difficulty of measuring the capture cross section data in the competing fission background, as the fission cross section is around one order of magnitude larger than the capture cross section for 233 U. The accuracy of a capture cross section measurement depends on discrimination between $\gamma$’s produced in capture and fission reactions, for which an experimental setup combining capture and fission detectors is needed. For the ($\eta$,$\gamma$) cross section measurement at LANSCE, this discrimination is achieved by combining the Detector for Advanced Neutron Capture Experiments (DANCE), to measure $\gamma$’s from capture reactions, with a Parallel Plate Avalanche Counter (PPAC) to tag the $\gamma$’s produced by fission. This method was successfully used to measure 235 U and 239 Pu capture cross sections. In these measurements, the neutron capture cross section was determined in a large fission background well above 100 keV. As part of the NCSP nuclear data effort, we have looked at past DANCE measurements on 233 U($\eta$,$\gamma$) and evaluated whether existing data is adequate to apply this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and Validation Tests of the Gamma Library of the ARC Software Package (Rev.1)

As part of the verification and validation (V&V) efforts of the Argonne Reactor Code (ARC) software system to support the Versatile Test Reactor (VTR) project of the U.S. Department of Energy (DOE), work has been performed to verify and validate the gamma (or photon) library of the multigroup cross section generation code MC 2 -3 of the ARC system, which is the essential part of the coupled neutron and gamma heating calculations to determine the heat generation rate or power distribution in the core. This V&V study was carried out in three steps: 1) review of the procedures and utility programs for generating the MC 2 -3 gamma library, 2) verification tests of cross sections and KERMA factors by comparing the total heat generation rate of coupled neutron and gamma calculation with that obtained with reaction Q values under the assumption of local gamma energy deposition and by comparing the prompt heat generation rate with that calculated with the MCNP6.2 code, and 3) validation tests of cross sections and KERMA factors by analyzing the ZPPR-15D gamma dose data measured with thermoluminescent dosimeters (TLD).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗