Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-Frequency Measurements of Methane Ebullition Over a Growing Season at a Temperate Peatland Site

Bubbles can contribute a significant fraction of methane emissions fr om wetlands; however the range of reported fractions is very large an d accurate characterization of this pathway has proven difficult. Her e we show that continuous automated flux chambers combined with an in tegrated cavity output spectroscopy (ICOS) instrument allow us to qua ntify both CH4 ebullition rate and magnitude. For a temperate poor f en in 2009, ebullition rate varied on hourly to seasonal time scales. A diel pattern in ebullition was identified with peak release occurr ing between 20:00 and 06:00 local time, though steady fluxes (i.e., t hose with a linear increase in chamber headspace CH4 concentration) d id not exhibit diel variability. Seasonal mean ebullition rates peake d at 843.5 +/- 384.2 events m(exp -2)/d during the summer, with a me an magnitude of 0.19 mg CH4 released in each event.

Goodrich, Jordan P.↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Morrison, John L.↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Suppressing interfering scattered signals in swept-frequency radar measurements by using frequency domain Wiener filtering

A novel approach to the reduction of scattered, interfering signals that corrupt measurements of the signal backscattered from radar targets of interest is being developed. It is being explored with sphere measurements in an indoor microwave radar range. This method is based on the concept of Wiener filtering (which minimizes the difference between the signal plus noise and the desired signal in the time domain). In contrast to the traditional Wiener filter, in which the time domain error between two sequences are minimized, the approach reported uses the frequency domain phasor amplitudes of a swept frequency signal. It minimizes the difference (least-mean-square-magnitude) between the signal-plus-noise and the signal complex phasors, across the entire spectrum.

Weissman, David E.↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermophysical property measurements in electromagnetic levitators

Proper measurements of thermophysical properties of hot levitated liquid drops require the following: accurate temperature measurement (brightness measurement, emissivity measurement); precise drop shape measurements with submillisecond time resolution (density determination, rotational and vibrational shape information); precise control of drop shape (high symmetry variable gap levitators); accurate energy transfer measurements (direct measurements of energy transfer rates for defined gas flows over samples with quantitative measurements of energy transfer rates for defined flows over samples with known shapes); and precise measurements of repetitive sample motions (rapid repetitive shape measurements, frequency measurements with reflected laser light, measurements in the levitator and as a freely falling drop). Recent advances in coil design and control of sample rotation in an electromagnetic levitator are discussed with respect to the above requirements.

Hauge, Robert H.↗

Retrieval of precipitation profiles from airborne radar and passive radiometer measurements - Comparison with dual-frequency radar measurements

Precipitation-rate profiles derived from a single-frequency radar and a radiometer are compared with profiles derived from a dual-frequency radar, using data obtained during the 1985-1986 Communication Research Laboratory/NASA rain measuring experiment over the Atlantic Ocean from a dual-frequency X- and Ka-band radars and an X-band passive radiometer. Profiles were retrieved using a modification of the Hitschfeld-Bordan (1954) algorithm constrained by a measurement of the path integrated extinction derived from passive radiometry. It was found that the two techniques under comparison yielded average rainfall rates that agreed within about 25 percent. It is suggested that, while a single-frequency radar operating in conjunction with multifrequency passive radiometers might provide cost-effective spaceborne measurements of tropical rainfall distributions, a dual-frequency radar might be able to remove some ambiguities that were encountered in this study.

Weinman, J. A.↗

Frequency domain measurement systems

Stable frequency sources and signal processing blocks were characterized by their noise spectra, both discrete and random, in the frequency domain. Conventional measures are outlined, and systems for performing the measurements are described. Broad coverage of system configurations which were found useful is given. Their functioning and areas of application are discussed briefly. Particular attention is given to some of the potential error sources in the measurement procedures, system configurations, double-balanced-mixer-phase-detectors, and application of measuring instruments.

Eischer, M. C.↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Buccino, Dustin R↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Oudrhiri, Kamal↗