Implementation of an Unsteady PSP System in the NASA Transonic Dynamics Tunnel

An unsteady pressure-sensitive paint (uPSP) system has been developed to provide time-resolved pressure measurements in the NASA Langley Transonic Dynamics Tunnel (TDT). Obtaining these measurements necessitated the development of environmental enclosures to protect the high-speed camera and ultraviolet lights required for uPSP from the harsh environment present during tunnel operation. Since the facility main drive was non-functioning during the testing window, performance of the uPSP system was demonstrated using an impinging jet with a passive oscillator attachment to provide unsteady flow with a known frequency independent of amplitude. Measurements were obtained for tunnel pressures ranging from 565 to 2116 psf, and model angles of attack between -4 degrees and 4 degrees. Results indicate that the system is capable of measuring surface pressure differentials on the order of 0.01 psi at full scale with a camera frame rate of at least 10 kHz. Spectral analysis shows that the fundamental frequency of the oscillating jet is captured by the uPSP system, as are the second and third harmonics. Dynamic mode decomposition highlights the dominant coherent spatial structures of the surface pressure, along with the associated frequency and growth rate of each mode, allowing for a de-noised reconstruction of the uPSP measurements. The experimental campaign outlined within this report also confirmed compatibility of the uPSP system with the TDT facility data acquisition system, and verified the successful integration with existing processing capabilities within the NASA advanced supercomputing environment.

unsteady pressure-sensitive paint↗

Implementation of an Unsteady PSP System in the NASA Transonic Dynamics Tunnel

An unsteady pressure-sensitive paint (uPSP) system has been developed to provide time-resolved pressure measurements in the NASA Langley Transonic Dynamics Tunnel (TDT). Obtaining these measurements necessitated the development of environmental enclosures to protect the high-speed camera and ultraviolet lights required for uPSP from the harsh environment present during tunnel operation. Since the facility main drive was non-functioning during the testing window, performance of the uPSP system was demonstrated using an impinging jet with a passive oscillator attachment to provide unsteady flow with a known frequency independent of amplitude. Measurements were obtained for tunnel pressures ranging from 565 to 2116 psf, and model angles of attack between -4 degrees and 4 degrees. Results indicate that the system is capable of measuring surface pressure differentials on the order of 0.01 psi at full scale with a camera frame rate of at least 10 kHz. Spectral analysis shows that the fundamental frequency of the oscillating jet is captured by the uPSP system, as are the second and third harmonics. Dynamic mode decomposition highlights the dominant coherent spatial structures of the surface pressure, along with the associated frequency and growth rate of each mode, allowing for a de-noised reconstruction of the uPSP measurements. The experimental campaign outlined within this report also confirmed compatibility of the uPSP system with the TDT facility data acquisition system, and verified the successful integration with existing processing capabilities within the NASA advanced supercomputing environment.

unsteady pressure-sensitive paint↗

Implementation of an Unsteady PSP System in the NASA TDT

An unsteady pressure-sensitive paint (uPSP) system has been developed to provide time-resolved pressure measurements in the NASA Langley Transonic Dynamics Tunnel (TDT). Obtaining these measurements necessitated the development of environmental enclosures to protect the high-speed camera and ultraviolet lights required for uPSP from the harsh environment present during tunnel operation. Since the facility main drive was non-functioning during the testing window, performance of the uPSP system was demonstrated using an impinging jet with a passive oscillator attachment to provide unsteady flow with a known frequency independent of amplitude. Measurements were obtained for tunnel pressures ranging from 565 to 2116 psf, and model angles of attack between -4 degrees and 4 degrees. Results indicate that the system is capable of measuring surface pressure differentials on the order of 0.01 psi at full scale with a camera frame rate of at least 10 kHz. Spectral analysis shows that the fundamental frequency of the oscillating jet is captured by the uPSP system, as are the second and third harmonics. Dynamic mode decomposition highlights the dominant coherent spatial structures of the surface pressure, along with the associated frequency and growth rate of each mode, allowing for a de-noised reconstruction of the uPSP measurements. The experimental campaign outlined within this report also confirmed compatibility of the uPSP system with the TDT facility data acquisition system, and verified the successful integration with existing processing capabilities within the NASA advanced supercomputing environment. Note: this presentation is an MP4 video with sound, color with a run time of 10 minutes 37 seconds.

unsteady pressure-sensitive paint↗

The Payload and Operations of the Hera Mission

On 26 September 2022, NASA’s DART mission successfully impacted on Dimorphos, the secondary of the binary asteroid Didymos. DART released the Light Italian Cubesat for Imaging of Asteroids (LICIACube) two weeks before the impact, and LICIACube flew by the asteroids three minutes after the impact. On approach, DART took images of both asteroids, which, supported by additional imagery from LICIACube, characterized the pre-impact state of the Didymos system. DART changed the orbit of Dimorphos around Didymos, reducing its orbital period by 33 minutes. DART will be followed by a detailed investigation of the Didymos system and the outcome of the impact by ESA’s Hera mission. Hera will be launched in October 2024 and arrive at Didymos in early 2027. The presentation will focus on the payload of the Hera mission and the operations at the asteroid system. The main objectives of the Hera mission are to: - Measure the mass of Dimorphos to accurately measure the momentum transfer efficiency of the DART impact. - Characterise the change of the surface of Dimorphos by DART, including the properties (and existence!) of the DART crater, to improve our understanding of impact physics and to observe unweathered material, recently exposed at the surface. - Determine the physical properties of Dimorphos, including its internal structure, to allow scaling of the impact to different types of asteroids. - Measure the dynamical and physical state of the Didymos and Dimorphos system to constrain binary formation scenarios. Hera is equipped with the following payload: Two Asteroid Framing Cameras (AFCs) for both science and navigation. There resolution is ~10-4 rad/pixel, or 40 cm/pixel for close observations from 4 km. They will provide the target global properties as well as local geomorphology and will investigate the crater and impact site. They will also measure the mass of Dimorphos through the “wobble” motion of Didymos. The Planetary ALTimeter (PALT) will measure the distance to the target and shape and topography information complementary to that from AFC images. The Thermal InfraRed Imager (TIRI) will provide information about the thermal properties of the Didymos system and spectral information in the mid-infrared (6 bands from 7 – 14 µm). The Hyperscout-H hyperspectral imager will provide mineralogical information from 25 spectral bands between 665 and 975 nm. Milani, a 6 unit cubesat, will carry a visible to near-IR imaging spectrometer (ASPECT, 500 – 2500 nm) to derive mineralogical information on the composition of the asteroids, and a thermogravimeter (VISTA) to measure the abundance and constrain the composition of ambient dust particles. Juventas, a 6 unit cubesat, will carry a monostatic low-frequency radar (JuRa), and a gravimeter (GRASS) to derive interior and surface properties of the asteroids. The Radio Science experiment will measure the gravity field of the Didymos system. Measurements of the acceleration of the Hera spacecraft by the asteroid pair through the radio link between Earth and Hera will be used as well as the inter-satellite link between Hera and the two cubesats. We will describe how the goals of Hera will be achieved with the different payload elements.

Michael Küppers↗

Screen of cylindrical lenses produces stereoscopic television pictures

Stereoscopic television pictures are produced by placing a colorless, transparent screen of adjacent parallel cylindrical lenses before a raster from two synchronized TV cameras. Alternate frames from alternate cameras are displayed. The viewers sensory perception fuses the two images into one three-dimensional picture.

Nork, C. L.↗

Algorithms for High-Speed Noninvasive Eye-Tracking System

Two image-data-processing algorithms are essential to the successful operation of a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. The system was described in High-Speed Noninvasive Eye-Tracking System (NPO-30700) NASA Tech Briefs, Vol. 31, No. 8 (August 2007), page 51. To recapitulate from the cited article: Like prior commercial noninvasive eyetracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Most of the prior commercial noninvasive eyetracking systems rely on standard video cameras, which operate at frame rates of about 30 Hz. Such systems are limited to slow, full-frame operation. The video camera in the present system includes a charge-coupled-device (CCD) image detector plus electronic circuitry capable of implementing an advanced control scheme that effects readout from a small region of interest (ROI), or subwindow, of the full image. Inasmuch as the image features of interest (the cornea and pupil) typically occupy a small part of the camera frame, this ROI capability can be exploited to determine the direction of gaze at a high frame rate by reading out from the ROI that contains the cornea and pupil (but not from the rest of the image) repeatedly. One of the present algorithms exploits the ROI capability. The algorithm takes horizontal row slices and takes advantage of the symmetry of the pupil and cornea circles and of the gray-scale contrasts of the pupil and cornea with respect to other parts of the eye. The algorithm determines which horizontal image slices contain the pupil and cornea, and, on each valid slice, the end coordinates of the pupil and cornea. Information from multiple slices is then combined to robustly locate the centroids of the pupil and cornea images. The other of the two present algorithms is a modified version of an older algorithm for estimating the direction of gaze from the centroids of the pupil and cornea. The modification lies in the use of the coordinates of the centroids, rather than differences between the coordinates of the centroids, in a gaze-mapping equation. The equation locates a gaze point, defined as the intersection of the gaze axis with a surface of interest, which is typically a computer display screen (see figure). The expected advantage of the modification is to make the gaze computation less dependent on some simplifying assumptions that are sometimes not accurate

Talukder, Ashit↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

System selects framing rate for spectrograph camera

Circuit using zero-order light is reflected to a photomultiplier in the incoming radiation of a spectrograph monitor to provide an error signal which controls the advancing and driving rate of the film through the camera.

Source record↗

Observational Investigation of Solar Interior and Atmosphere

The Imaging Vector Magnetograph (IVM) has been modified to make it easier to observe at more than one spectral line. The cell holding the blocking filter has been replaced by a four-position filter wheel, so that changing to a different line is a matter of a few minutes rather than the several hours it used to take to disassemble the cell and install a new filter. Three new filters have been obtained, for Na 1589.6 nm, Fe 1630.25 nm, and H 1656.3 nm. The new filters have better bandpass profiles than the ones they replaced: somewhat wider, with flatter tops and steeper wings. This results in a reduction of parasitic light coming from adjacent Fabry-Perot orders, from seven percent to about two percent, and flattens the apparent continuum. The Mees CCD Imaging Spectrograph (MCCD) was upgraded under this grant, with a new control computer and data system. The camera was replaced with a faster, larger-format frame-transfer camera. Final integration of the upgrades is not yet complete, but tests indicate that the system cadence will be improved by a factor of five to ten, while increasing the spatial coverage by a factor of two (depending on observation options). Synoptic observations with the IVM and MCCD continue to be conducted daily, to the extent permitted by the fact that we have a single observer responsible for the observations. The older Haleakala Stokes Polarimeter is also used to make a daily vector magnetogram, normally of the region selected by the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) duty scientists. This instrument, however, is showing its age to the extent that its maintenance is becoming something of a challenge. We also run a white light full-disk imager and a video H alpha prominence camera, continuously during times of observations. Of particular interest, we obtained rapid-cadence observations of the 2003 July 15 white light flare with both the IVM and MCCD. The vector magnetograms show no obvious difference between the preflare and postflare configurations. The photospheric magnetogram sequence and H alpha spectra we obtained can be combined with spacecraft observations to construct a rather detailed picture of the events of this flare. Several papers are in preparation.

Kuhn, Jeffrey R.↗

Flammability Limits of Gases Under Low Gravity Conditions

The purpose of this combustion science investigation is to determine the effect of zero, fractional, and super gravity on the flammability limits of a premixed methane air flame in a standard 51 mm diameter flammability tube and to determine, if possible, the fluid flow associated with flame passage under zero-g conditions and the density (and hence, temperature) profiles associated with the flame under conditions of incipient extinction. This is accomplished by constructing an appropriate apparatus for placement in NASA's Lewis Research Center Lear Jet facility and flying the prescribed g-trajectories while the experiment is being performed. Data is recorded photographically using the visible light of the flame. The data acquired is: (1) the shape and propagation velocity of the flame under various g-conditions for methane compositions that are inside the flammable limits, and (2) the effect of gravity on the limits. Real time accelerometer readings for the three orthogonal directions are displayed in full view of the cameras and the framing rate of the cameras is used to measure velocities.

Strehlow, R. A.↗

Optical variability of extragalactic objects used to tie the HIPPARCOS reference frame to an extragalactic system using Hubble space telescope observations

Observations of a set of 89 extragalactic objects (EGOs) will be made with the Hubble Space Telescope Fine Guidance Sensors and Planetary Camera in order to link the HIPPARCOS Instrumental System to an extragalactic coordinate system. Most of the sources chosen for observation contain compact radio sources and stellarlike nuclei; 65 percent are optical variables beyond a 0.2 mag limit. To ensure proper exposure times, accurate mean magnitudes are necessary. In many cases, the average magnitudes listed in the literature were not adequate. The literature was searched for all relevant photometric information for the EGOs, and photometric parameters were derived, including mean magnitude, maximum range, and timescale of variability. This paper presents the results of that search and the parameters derived. The results will allow exposure times to be estimated such that an observed magnitude different from the tabular magnitude by 0.5 mag in either direction will not degrade the astrometric centering ability on a Planetary Camera CCD frame.

Bozyan, Elizabeth P.↗

Area Coverage Planning with 3-axis Steerable, 2D Framing Sensors

Existing algorithms for Agile Earth Observing Satellites((Lemaitre et al. 2002)) were largely created for 1D line sensors that acquire images in linear swaths. However, imaging satellites increasingly use 2D framing sensors (cameras) that capture discrete rectangular images. We describe tiling step-stare approaches that are more suited to rectangular image footprints than are 1D swath-based algorithms. Optimal area planning for these 2D framing instruments is an NPcomplete problem and intractable for large areas, so we present four approximation algorithms. Strategies are compared against a prior 2D framing instrument algorithm (Knight 2014) in three computational experiments. The impact of observer agility on schedule makespan is examined. Makespans vary more as observer agility decreases toward a critical point, then vary less after the critical point, suggesting a possible problem phase transition.

Chien, Steve↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro- polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with a gain of 2.0 +/- 0.5, less than or equal to 25 e- readout noise, less than or equal to 10 e-/second/pixel dark current, and less than 0.1percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; system gain, dark current, read noise, and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30%) quantum efficiency at the Lyman-$\alpha$ line. The CLASP cameras were designed to operate with ≤10 e- /pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 and ≤0.1% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, P.↗

A high-speed spectrograph shutter

Device can operate in close-open-close mode. Beam splitter placed behind static-slit assembly allows use of more than one camera. Each frame in particular series may be conveniently varied in exposure time and spacing. This can be done independent of other frames in the series. In ''open'' position, shutter transmits light over wide wavelength range.