Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “four-dimensional scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

86 records · Page 5

Operando studies reveal active Cu nanograins for CO 2 electroreduction

Carbon dioxide electroreduction facilitates the sustainable synthesis of fuels and chemicals. Although Cu enables CO 2 -to-multicarbon product (C 2+ ) conversion, the nature of the active sites under operating conditions remains elusive. Importantly, identifying active sites of high-performance Cu nanocatalysts necessitates nanoscale, time-resolved operando techniques. Here, we present a comprehensive investigation of the structural dynamics during the life cycle of Cu nanocatalysts. A 7 nm Cu nanoparticle ensemble evolves into metallic Cu nanograins during electrolysis before complete oxidation to single-crystal Cu 2 O nanocubes following post-electrolysis air exposure. Operando analytical and four-dimensional electrochemical liquid-cell scanning transmission electron microscopy shows the presence of metallic Cu nanograins under CO 2 reduction conditions. Correlated high-energy-resolution time-resolved X-ray spectroscopy suggests that metallic Cu, rich in nanograin boundaries, supports undercoordinated active sites for C–C coupling. Quantitative structure–activity correlation shows that a higher fraction of metallic Cu nanograins leads to higher C 2+ selectivity. A 7 nm Cu nanoparticle ensemble, with a unity fraction of active Cu nanograins, exhibits sixfold higher C 2+ selectivity than the 18 nm counterpart with one-third of active Cu nanograins. Importantly, the correlation of multimodal operando techniques serves as a powerful platform to advance our fundamental understanding of the complex structural evolution of nanocatalysts under electrochemical conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tiny Bubbles: Combined HR(S)TEM and 4D-STEM Analysis of Sub-Nanometer He Bubbles in Au

Irradiation produces a distribution of defect sizes in materials, with the smallest defects often below one nanometer in size and approaching the scale of a single unit cell in metals. While high-resolution scanning transmission electron microscopy (STEM)-based imaging can directly image structures at this level, techniques such as four-dimensional STEM (4D-STEM) enable characterization of materials across large fields of view, capturing a more representative volume that can be valuable for quantifying defects, their distributions, and the associated strain fields. Here we present a combined HRSTEM and 4D-STEM approach to study the model system of He bubble implantation in an Au thin film. The present work is of general interest for the study of materials in extreme environments, as it demonstrates an effective way to characterize even the tiniest sub-nanometer sized He bubbles in addition to larger irradiation defects.

atomic-resolution STEM↗

Four-dimensional phase-space reconstruction of flat and magnetized beams using neural networks and differentiable simulations

Beams with cross-plane coupling or extreme asymmetries between the two transverse phase spaces are often encountered in particle accelerators. Flat beams with large transverse-emittance ratios are critical for future linear colliders. Similarly, magnetized beams with significant cross-plane coupling are expected to enhance the performance of electron cooling in hadron beams. Preparing these beams requires precise control and characterization of the four-dimensional transverse phase space. In this study, we employ generative phase-space reconstruction techniques to rapidly characterize magnetized and flat-beam phase-space distributions using a conventional quadrupole-scan method. The reconstruction technique is experimentally demonstrated on an electron beam produced at the Argonne Wakefield Accelerator and successfully benchmarked against conventional diagnostics techniques. Specifically, we show that predicted beam parameters from the reconstructed phase-space distributions (e.g., as magnetization and flat-beam emittances) are in excellent agreement with those measured from the conventional diagnostic methods. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

STEM Imaging of Materials: Final Report for DE-FG02-08ER46547

This project supported research advancing the state of the art in scanning transmission electron microscopy (STEM) imaging and characterization of materials, especially electronic materials. The project began with studies of point defects in materials using high-resolution Z-contrast STEM, then evolved to including methods in four-dimensional (4D) STEM and machine learning. Highlights include: (1) the discovery of stable, p-type ZnO via Sb doping, (2) demonstration that the high performance of InGaN LEDs is not due to In composition fluctuations as previously proposed, (3) the demonstration of the first sub-pm precision high-resolution STEM images using non-rigid registration of a series of STEM images, (4) the extension of high-precision STEM to low dose imaging and spectrum imaging, (5) discovery of a synthesis method for twisted spiral growth of transition-metal dichalcogenide materials via chemical vapor deposition, and (6) development of machine-learning methods for analysis and denoising of enormous 4D STEM data sets.

36 MATERIALS SCIENCE↗

Recent Developments in Femtosecond Laser-Enabled TriBeam Systems

Streams of multimodal three-dimensional (3D) and four-dimensional (4D) data are revolutionizing our ability to design and predict the behavior of a broad array of advanced materials systems. Over the last 10 years, a new 3D imaging platform consisting of a femtosecond (fs) pulsed laser coupled with a focused ion beam scanning electron microscope (FIB SEM) has been developed by UC Santa Barbara in collaboration with Thermo Fisher Scientific (formerly FEI). The femtosecond-laser-enabled FIB SEM, called the TriBeam, has become one of the only 3D serial sectioning methods available that can gather millimeter-scaled multimodal datasets at sub-μm voxel resolutions; these length scales are critical for many materials problems. Multimodal chemical, crystallographic, and morphological information can be gathered rapidly on a layer-by-layer basis and reconstructed in 3D. Large (gigabyte to terabyte scale) 3D datasets have been generated for a broad array of materials systems, including metallic alloys, ceramics, biomaterials, polymer- and ceramic-matrix composites, and semiconductors. The research tasks conducted have resulted in a completely new design, operating with a dual-wavelength femtosecond-pulsed laser on a plasma focused ion beam (PFIB) platform.

36 MATERIALS SCIENCE↗

Operando probing dynamic migration of copper carbonyl during electrocatalytic CO2 reduction

Single crystals and shape-controlled nanocrystals are well known to exhibit facet-dependent catalytic properties. However, few studies have investigated how those nanocrystals evolve and (de)activate during reactions, calling for the development of nanoscale time-resolved operando methods. In this context, we have designed Cu nanocubes as a model system to elucidate the underlying driving force of dynamic nanocatalyst reconstruction during the CO2 reduction reaction (CO2RR). Operando electrochemical liquid-cell scanning transmission electron microscopy (EC-STEM) and synchrotron-based X-ray spectroscopy reveal the size- and potential-dependent complete transformation from (100)-oriented Cu@Cu2O nanocubes to polycrystalline metallic Cu nanograins under CO2RR conditions. In addition, machine learning-assisted operando four-dimensional STEM reveals that large Cu nanograins derived from nanocubes form mainly crystalline domains, while their smaller counterparts are more amorphous due to faster evolution kinetics. In situ Raman spectroscopy and density functional theory calculations suggest that CO drives the ejection of single Cu atoms, resulting in few-nanometre Cu clusters and the surface migration of highly mobile copper carbonyl (Cu–CO) species. Combined, these multimodal operando methods and theoretical approaches pave the way for understanding the complex structural evolution of energy-related nanocatalysts under electrochemical conditions.

Yang, Yao↗

Operando Electrochemical Liquid-Cell Scanning Transmission Electron Microscopy (EC-STEM) Studies of Evolving Cu Nanocatalysts for CO 2 Electroreduction

The design and synthesis of nanocatalysts with well-defined sizes, compositions, and structures have revolutionized our accessibility to tunable catalyst activity and selectivity for a variety of energy-related electrochemical reactions. Nonetheless, establishing structure-(re)activity correlations requires the understanding of the dynamic evolution of pristine nanocatalysts and the identification of their active states under operating conditions. We previously communicated the operando observation of Cu nanocatalysts evolving into active metallic Cu nanograins for CO 2 electroreduction (Yang et al. Nature 2023, 614, 262–269). Here, we expand our discussion to the technical capabilities and further research applications of operando electrochemical liquid-cell scanning transmission electron microscopy (EC-STEM), which enables quantitative electrochemistry while tracking dynamic structural evolution of sub-10 nm Cu nanocatalysts. The coexistent H 2 bubbles, often disruptive to operando spectroscopy, are an effective approach to create a thin-liquid layer that significantly improves spatial resolution while remaining electrochemically accessible to Cu nanocatalysts. Operando four-dimensional (4D) STEM in liquids provides insights into the complex structure of active polycrystalline metallic Cu nanograins. With continuous technical developments, we anticipate that operando EC-STEM will evolve into a powerful electroanalytical method to advance our understanding of a variety of nanoscale electrocatalysts at solid/liquid interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Formation of Irradiation-Induced Defects through 4D-STEM, Electron Tomography, and WBDF-STEM

A major challenge in advancing nuclear materials for next-generation fission and proposed fusion reactors is to comprehensively understand the formation of irradiation-induced defects. Here it is essential to correlate the evolution of irradiation-induced defects and the degradation of mechanical properties, as they collectively dictate the material's lifespan and ensure nuclear safety. Scanning transmission electron microscopy (STEM) based techniques have emerged as indispensable tools for irradiation-induced defect characterization, offering high spatial resolution imaging and chemical analysis, such as electron energy loss spectroscopy (EELS) and energy dispersive X-ray spectroscopy (EDXS). These techniques have been effectively used to obtain an atomic-scale view of the defect structure. Recent advances in electron microscopy, particularly in 4D-STEM, offer detailed insight into microstructural evolution by capturing full 2D diffraction patterns at every pixel position. Using high-speed direct electron detectors, this technology generates a four-dimensional dataset, overcoming the limitations of traditional STEM imaging.

36 MATERIALS SCIENCE↗

Dynamic Evolution of Copper Nanowires during CO 2 Reduction Probed by Operando Electrochemical 4D-STEM and X-ray Spectroscopy

Nanowires have emerged as an important family of one-dimensional (1D) nanomaterials owing to their exceptional optical, electrical, and chemical properties. In particular, Cu nanowires (NWs) show promising applications in catalyzing the challenging electrochemical CO 2 reduction reaction (CO 2 RR) to valuable chemical fuels. Despite early reports showing morphological changes of Cu NWs after CO 2 RR processes, their structural evolution and the resulting exact nature of active Cu sites remain largely elusive, which calls for the development of multimodal operando time-resolved nm-scale methods. Here, in this study, we report that well-defined 1D copper nanowires, with a diameter of around 30 nm, have a metallic 5-fold twinned Cu core and around 4 nm Cu 2 O shell. Operando electrochemical liquid-cell scanning transmission electron microscopy (EC-STEM) showed that as-synthesized Cu@Cu 2 O NWs experienced electroreduction of surface Cu 2 O to disordered (spongy) metallic Cu shell (Cu@Cu S NWs) under CO 2 RR relevant conditions. Cu@Cu S NWs further underwent a CO-driven Cu migration leading to a complete evolution to polycrystalline metallic Cu nanograins. Operando electrochemical four-dimensional (4D) STEM in liquid, assisted by machine learning, interrogates the complex structures of Cu nanograin boundaries. Correlative operando synchrotron-based high-energy-resolution X-ray absorption spectroscopy unambiguously probes the electroreduction of Cu@Cu 2 O to fully metallic Cu nanograins followed by partial reoxidation of surface Cu during postelectrolysis air exposure. This study shows that Cu nanowires evolve into completely different metallic Cu nanograin structures supporting the operando (operating) active sites for the CO 2 RR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport-based initial conditions for heavy-ion collisions at finite densities

Here, we employ the SMASH transport model to provide event-by-event initial conditions for the energy-momentum tensor and conserved charge currents in hydrodynamic simulations of relativistic heavy-ion collisions. We study the fluctuations and dynamical evolution of three conserved charge currents (net baryon, net electric charges, and net strangeness) with a four-dimensional lattice-QCD-based equation of state, NEOS-4D, in the hydrodynamic phase. Out-of-equilibrium corrections at the particlization are generalized to finite densities to ensure the conservation of energy, momentum, and the three types of charges. These theoretical developments are integrated within the X-SCAPE code as a unified framework for studying the nuclear matter properties in the Beam Energy Scan program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗