Engineering PapersSearch

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Space telescope optical telescope assembly/scientific instruments. Phase B: Preliminary design and program definition study. Volume 2A. focal plane camera

Trade studies were conducted to ensure the overall feasibility of the focal plane camera in a radial module. The primary variable in the trade studies was the location of the pickoff mirror, on axis versus off-axis. Two alternatives were: (1) the standard (electromagnetic focus) SECO submodule, and (2) the MOD 15 permanent magnet focus SECO submodule. The technical areas of concern were the packaging affected parameters of thermal dissipation, focal plane obscuration, and image quality.

Source record

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.

Low background focal plane array testing in the far infrared

A new long-wavelength infrared test facility is being developed to conduct proof-of-performance tests of focal plane arrays for the Infrared Astronomical Satellite (IRAS) telescope. This facility is believed to be unique in that it will calibrate full-sized arrays designed for the 5-120-micron region of the IR spectrum under simulated spaceflight conditions and at background levels as low as 8 million photons/sq cm-sec. Most of the tests will be performed in a main test chamber which contains a liquid helium shroud, blackbody sources, an arrangement to simulate zodiacal background, and spot scanning optics. A noncontaminating high-vacuum pumping system will be used to evacuate the chamber prior to cool-down to prevent molecular deposition. All housekeeping and focal plane signal outputs are multiplexed, digitized, and transmitted on high-speed data lines to a PDP-11/70 computer. The computer provides real-time displays on a color CRT terminal and stores data for subsequent reduction and hard copy output. An overview of the conceptual design and performance specifications of the test facility are given.

Iufer, E. J.

Interpolation and extrapolation of creep rupture data by the Minimum Commitment Method. I - Focal-point convergence. II - Oblique translation. III - Analysis of multiheats

The framework in which minimum-commitment analyses of creep-rupture data can be implemented is outlined. The approach is termed the focal point convergence method (FPCM) because the basic parameter A, also known as stability factor, is geometrically the (imaginary) focal point of convergence of all isothermals when extended to the very long or very short times necessary for such convergence to occur. The method can be implemented either by manual-graphical analysis or by computer code. The method is illustrated in detail for the nickel-base alloy Astroloy, as well as for steels, other nickel-base alloys, and aluminum alloys. The minimum-commitment concept is extended to the analysis of creep-rupture data where each isothermal is generated by an oblique translation of the 'master curve' when plotted on log rupture time and log stress axes. The oblique translation method uses the same types of functions in the FPCM. Approaches for treating multiheats on the basis of the FPCM are discussed in detail.

Manson, S. S.

Geometries and focal properties of two electron-lens systems useful in low-energy electron or ion scattering

Geometries and focal properties are given for two types of electron-lens system commonly needed in electron scattering. One is an electron gun that focuses electrons from a thermionic emitter onto a fixed point (target) over a wide range of final energies. The other is an electron analyzer system that focuses scattered electrons of variable energy onto a fixed position (e.g., the entrance plane of an analyzer) at fixed energy with a zero final beam angle. Analyzer-system focusing properties are given for superelastically, elastically, and inelastically scattered electrons. Computer calculations incorporating recent accurate tube-lens focal properties are used to compute lens voltages, locations and diameters of all pupils and windows, filling factors, and asymptotic rays throughout each lens system. Focus voltages as a function of electron energy and energy change are given, and limits of operation of each system discussed. Both lens systems have been in routine use for several years, and good agreement has been consistently found between calculated and operating lens voltages.

Chutjian, A.

Infrared focal plane arrays for planetary missions

Requirements for infrared detector array focal planes suitable for a set of prospective planetary missions are developed. Using the Galileo mission to Jupiter as a starting point, objectives and constraints applicable to outer planet missions are developed. The concept for an advanced mapping spectrometer utilizing 128 x 128 element infrared detector arrays is described. Specific implementations for the Saturn Orbiter Dual Probe mission, a Mars Orbiter mission, and a Titan Orbiter mission are defined. The analysis indicates that within the 1 to 5 micron range, broad scientific objectives for these missions can be met using focal plane arrays with detectivities on the order of 10 to the 14th cm sq root of Hz per W. The realization of such high detectivities in a low background application will necessitate careful development of the method by which the detector signals are multiplexed and read out.

Wellman, J. B.

Submillisecond measurements of system optical modulation functions in mosaic focal plane arrays

Measurements of system optical modulation functions (MTF, SWR) may be distorted by time-dependent environmental effects (thermal, vibration, flexure) and by electronics drift. Fast data collection may therefore be advantageous by minimizing drift time. The problem of fast data collection is accentuated when modulation data must be taken on a large number of detectors in a focal plane array. A method has been developed for the generation and storage of knife edge data from focal plane arrays, where data collection time per detector is in the submillisecond range. Once knife edge collects are completed, MTF response is found using conventional convolution techniques. SWR is obtained directly from knife edge response using a computerized simulation algorithm which bypasses use of MTF harmonics. Requirements for detector electronics speed, damping, and dynamic range are considered.

Thurlow, P. E.

Alignment techniques required by precise measurement of effective focal length

The characteristics of false color imagery produced by instrumentation on earth resource mapping satellites are examined. The spatial fidelity of the imagery is dependent upon the geometric accuracy (GA) and the band-to-band registration (BBR) with which the telescope instrument is assembled. BBR and GA require knowledge of telescope effective focal length (EFL) to one part in 10,000 in order that the next generation of earth mappers be able to carry out their missions. The basis for this level of precision is briefly considered, and a description is given of the means by which such precise EFL measurements have been carried out. Attention is given to accuracy requirements, the technique used to measure effective focal length, possible sources of error in the EFL measurement, approaches for eliminating errors, and the results of the efforts to control measurement errors in EFL determinations.

Wise, T. D.

Finding the Focal Axes of Offset Antennas

Focal axis of offset paraboloidal reflector antennas determined by direct measurement instead of trial and error. Two feed horns transmit sum or difference pattern to antenna under test, which reflects energy to far-field detector. When axis of feed horns coincides with focal axis of antenna reflector, far-field detector records minimum in amplitude difference and maximum in absolute-magnitude phase difference between sum and difference signals.

Schmidt, R. F.

Focal plane array optical proximity sensor

An optical proximity sensor for optically detecting an object within a predetermined detection volume is described. More specifically, an optical proximity sensor is disclosed having an illuminator assembly including lens and a plurality of light-emitting diodes located at first predetermined positions along the focal plane of the illuminator lens. A detector assembly including a detector lens and a plurality of photodiodes located at second predetermined positions along the focal plane of the detector lens is also provided. The two lenses are spaced apart a predetermined distance in order to define a predetermined detection volume. Additionally, a combination of optical proximity sensors, according to the invention, is disclosed wherein the sensors can be used in conjunction with a vehicle to provide a safety system for warning an operator when an object is within a volume defined by the proximity sensor combination.

Johnston, A. R.

Design of a variable-focal-length optical system

Requirements to place an entire optical system with a variable focal length ranging from 20 to 200 cm within a overall length somewhat less than 100 cm placed severe restrictions on the design of a zoom lens suitable for use on a comet explorer. The requirements of a wavelength range of 0.4 to 1.0 microns produced even greater limitations on the possibilities for a design that included a catadioptric (using mirrors and glass) front and followed by a zooming refractive portion. Capabilities available commercial zoom lenses as well as patents of optical systems are reviewed. Preliminary designs of the refractive optics zoom lens and the catadioptric system are presented and evaluated. Of the two, the latter probably has the best chance of success, so long as the shortest focal lengths are not really needed.

Ricks, D.

Focal shifts in parabolic reflectors

The case of a parabolic reflector and a point feed is considered, taking into account the question regarding the location in which the feed should be placed for an achievement of maximum directivity. Based on the tracing of geometrical rays, the obvious answer is obtained that the feed should be placed at the focal point. In the present paper, it is shown that this answer is not always correct. There are situations in which the maximum directivity is achieved when the feed is axially displaced toward the reflector or away from it. This 'focal shift' phenomenon is a result of three competing factors which affect the directivity of a reflector. The factors are related to phase synchronism over the reflector aperture, aperture illumination efficiency, and spillover loss. For achieving the maximum directivity, it is necessary to find the best compromise among the three factors.

Ling, H.

Results of testing short wavelength HgCdTe hybrid focal plane arrays for earth remote sensing applications

The NASA Imaging Spectrometer program has the objective to develop the next generation of earth remote sensing systems. One part of the program is concerned with the production of advanced short-wavelength mercury cadmium telluride (HgCdTe) hybrid focal plane arrays (FPAs). These arrays are needed for several instruments, including the Shuttle Imaging Spectrometer (SIS), which requires a mosaic of six 64 x 64-element arrays with a cutoff wavelength of 2.5 microns. A device description is provided and the test results are considered. The Airborne Imaging Spectrometer (AIS) is discussed, taking into account an instrument description, focal plane requirements, and AIS results.

Blessinger, M. A.

Focal region fields of distorted reflectors

The problem of the focal region fields scattered by an arbitrary surface reflector under uniform plane wave illumination is solved. The physical optics (PO) approximation is used to calculate the current induced on the reflector. The surface of the reflector is described by a number of triangular domain-wise 5th degree bivariate polynomials. A 2-dimensional Gaussian quadrature is employed to numerically evaluate the integral expressions of the scattered fields. No Freshnel or Fraunhofer zone approximations are made. The relation of the focal fields problem to surface compensation techniques and other applications are mentioned. Several examples of distorted parabolic reflectors are presented. The computer code developed is included, together with instructions on its usage.

Buris, N. E.

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark

Short wavelength 128 by 128 focal plane arrays for remote sensing applications

Short-wavelength (1-2.5-micron) 128x128 focal plane arrays have been fabricated and demonstrated with high pixel yields and dark-current-limited performance. The detector material is HgCdTe grown by LPE on a sapphire substrate which yields high-performance uniform detectors. The detector arrays were characterized at temperatures of 80-150 K; the peak quantum efficiency at 2.4 microns is 80 percent. The multiplexer is a Reticon FET switch with output amplifiers. It is noted that the long-term goal of this project is to develop a 150x1000 mosaicked focal plane for use in the HIRIS instrument on the Earth Observing System.

Bothwell, Mary

Design of the focal plane array assembly for the Mars Observer/Visual and Infrared Mapping Spectrometer (MO/VIMS)

A unique focal plane array (FPA) assembly combining both electronic and optical components in a single hermetically sealed hybrid package has been designed to meet the performance requirements imposed on the focal plane assembly in the Visual and Infrared Mapping Spectrometer (VIMS) for the Mars Observer (MO) mission. Inside the FPA package is a configuration of three multiplexed linear arrays containing 320 detector elements, a combination of Si and InSb, allowing continuous spectral coverage from 0.35 to 5.14 microns. An optical subassembly consisting of two spectral order-sorting filters with intrinsic field-of-view apertures requiring critical optical alignment is also internal to the hybrid. Several engineering issues arose during the MO/VIMS FPA development phase which had challenging design ramifications. FPA performance requirements, design approach, and critical issues are discussed.

Niblack, Curtiss A.

256 x 256 PACE-1 PV HgCdTe focal plane arrays for medium and short wavelength infrared applications

The development of two 256 by 256 hybrid HgCdTe focal plane array (FPA) families is described, and their performance is discussed. The hybrid FPAs employ a PV HgCdTe detector array and custom Si CMOS readouts. The PACE-1 process was used to fabricate the detectors, whereby the liquid phase epitaxial growth of HgCdTe occurs on sapphire substrates buffered by a layer of CdTe. The performance characteristics of the detector arrays are given. A tactical 256 by 256 CMOS readout is tested, in which a high functional yield was achieved. Updated test results are given for a 256 by 256 readout circuit developed for use in an orbital replacement instrument for the Hubble Space Telescope. The characterizations of several MWIR and SWIR FPAs were thorough and shown to be reliable. The pixel yield, maximum FPA responsivity nonuniformity, and SWIR FPA read noise for the tests are given. The high contrast and insignificant fixed pattern noise of the imagery from the MWIR 256 by 256 FPA are emphasized. These qualities were obtained when the device was operating at 80 k and utilizing f/2 optics with an 8-in. focal length and a 4.4 micron high pass filter.

Kozlowski, L. J.