Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-G-207-03: High Spatial Resolution and High Sensitivity X-Ray Fluorescence Imaging

Last few years has witnessed the development of novel of X-ray imaging modalities, such as spectral CT, phase contrast CT, and X-ray acoustic/fluorescence/luminescence imaging. This symposium will present the recent advances of these emerging X-ray imaging modalities and update the attendees with knowledge in various related topics, including X-ray photon-counting detectors, X-ray physics underlying the emerging applications beyond the traditional X-ray imaging, image reconstruction for the novel modalities, characterization and evaluation of the systems, and their practical implications. In addition, the concept and practical aspects of X-ray activatable targeted nanoparticles for molecular X-ray imaging will be discussed in the context of X-ray fluorescence and luminescence CT. Learning Objectives: Present background knowledge of various emerging X-ray imaging techniques, such as spectral CT, phase contrast CT and X-ray fluorescence/luminescence CT. Discuss the practical need, technical aspects and current status of the emerging X-ray imaging modalities. Describe utility and future impact of the new generation of X-ray imaging applications.

60 APPLIED LIFE SCIENCES↗

Synchrotron fluorescence imaging of individual mouse beta-cells reveals changes in zinc, calcium, and iron in a model of low-grade inflammation

Pancreatic beta-cells synthesize and secrete insulin maintaining an organism's energy homeostasis. In humans, beta-cell dysfunction and death contribute to the pathogenesis of type 2 diabetes (T2D). Although the causes of beta-cell dysfunction are complex, obesity-induced low-grade systemic inflammation plays a role. For example, obese individuals exhibiting increased levels of proinflammatory cytokines IL-6 and IL-1beta have a higher risk of beta-cell dysfunction and T2D. Interestingly, obesity-induced inflammation changes the expression of several cellular metal regulating genes, prompting this study to examine changes in the beta-cell metallome after exposure to proinflammatory-cytokines. Here, primary mouse beta-cells were exposed to a combination of IL-6 and IL-1beta for 48 hours, were chemically fixed and imaged by synchrotron X-ray fluorescent microscopy. Quantitative analysis showed a surprising 2.4-fold decrease in the mean total cellular content of zinc from 158 ± 57.7 femtograms (fg) to 65.7 ± 29.7 fg; calcium decreased from 216 ± 67.4 to 154.3 ± 68.7 fg (control vs. cytokines, respectively). The mean total cellular iron content slightly increased from 30.4 ± 12.2 to 47.2 ± 36.4 fg after cytokine treatment; a sub-population of cells (38%) exhibited larger increases of iron density. Changes in the subcellular distributions of zinc and calcium were observed after cytokine exposure. Beta-cells contained numerous iron puncta that accumulated still more iron after exposure to cytokines. These findings provide evidence that exposure to low levels of cytokines is sufficient to cause changes in the total cellular content and/or subcellular distribution of several metals known to be critical for normal beta-cell function.

59 BASIC BIOLOGICAL SCIENCES↗

Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues--Preliminary Results

Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative planar laser-induced fluorescence imaging of multi-component fuel/air mixing in a firing gasoline-direct-injection engine: Effects of residual exhaust gas on quantitative PLIF

A study of in-cylinder fuel-air mixing distributions in a firing gasoline-direct-injection engine is reported using planar laser-induced fluorescence (PLIF) imaging. A multi-component fuel synthesised from three pairs of components chosen to simulate light, medium and heavy fractions was seeded with one of three tracers, each chosen to co-evaporate with and thus follow one of the fractions, in order to account for differential volatility of such components in typical gasoline fuels. In order to make quantitative measurements of fuel-air ratio from PLIF images, initial calibration was by recording PLIF images of homogeneous fuel-air mixtures under similar conditions of in-cylinder temperature and pressure using a re-circulation loop and a motored engine. This calibration method was found to be affected by two significant factors. Firstly, calibration was affected by variation of signal collection efficiency arising from build-up of absorbing deposits on the windows during firing cycles, which are not present under motored conditions. Secondly, the effects of residual exhaust gas present in the firing engine were not accounted for using a calibration loop with a motored engine. In order to account for these factors a novel method of PLIF calibration is presented whereby 'bookend' calibration measurements for each tracer separately are performed under firing conditions, utilising injection into a large upstream heated plenum to promote the formation of homogeneous in-cylinder mixtures. These calibration datasets contain sufficient information to not only characterise the quantum efficiency of each tracer during a typical engine cycle, but also monitor imaging efficiency, and, importantly, account for the impact of exhaust gas residuals (EGR). By use of this method EGR is identified as a significant factor in quantitative PLIF for fuel mixing diagnostics in firing engines. The effects of cyclic variation in fuel concentration on burn rate are analysed for different fuel injection strategies. Finally, mixture distributions for late injection obtained using quantitative PLIF are compared to predictions of computational fluid dynamics calculations. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cubex: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the miniaturized X-ray telescope payload, CubeX, in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. This instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing-based navigation (XNAV). It combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 Amp-microsecond) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts, in a small form factor (volume approximately 1 by 1 by 6 Units, and mass, < 6 kg). In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance.

X-ray Fluorescence↗

CubeX: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the miniaturized X-ray telescope payload, CubeX, in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. This instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing-based navigation (XNAV). It combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 μsec) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts, in a small form factor (~1×1×6U, <6 kg). In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance.

Lunar Science↗

The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CubeX: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the benefits of a miniaturized X-ray telescope payload in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. The CubeX instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing based navigation (XNAV). Using our recent technological advances in X-ray optics and sensors, CubeX combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 usec) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts. The high angular resolution of the MiXO opens a wide range of orbital configurations for observation. Given that performance, the instrument has unprecedented small volume (~1×1×6U), mass (<6 kg), and power (<9W) requirements and opens a wide range of applications for a variety of targets and missions including NEOs and Martian moons. In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. X-ray observations, therefore, give a unique, powerful diagnostic tool for remotely determining elemental abundances including major rock forming elements such as Mg, Al, Na, Si, Fe, and Ca. Through high-resolution XRF imaging spectroscopy, CubeX searches for small patches of elusive lower crust and mantle material excavated within and around impact craters. CubeX identifies regional compositional variations and allows straightforward comparison of elemental distributions with the surface topography from LRO and the gravity data from GRAIL. The elemental compositions of the lower crust and the mantle are sensitive to the conditions of the giant impact which led to the Moon's formation and the subsequent lunar magma ocean (LMO), and thus they are key missing pieces in understanding the formation and early evolution of the Moon. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance. Deep space navigation is a critical issue for small planetary missions. XNAV can enable low-cost autonomous deep-space navigation, and has the potential to greatly assist, or even outperform, NASA's Deep Space Network (DSN) or ESA's European Space Tracking (ESTRACK). CubeX is designed to perform sequential observations of 3-4 millisecond pulsars (MSPs) to solve the spacecraft trajectory for absolute navigation, and explore the remote sensing capability of XNAV. In the presented mission concept, the Moon's relative proximity enables a straightforward evaluation of the XNAV performance through DSN.

x-ray spectroscopy↗

Enzyme-Directed Assembly of Nanoparticles in Tumors Monitored by In Vivo Whole Animal and Ex Vivo Super-Resolution Fluorescence Imaging

Matrix metalloproteinase enzymes, overexpressed in HT-1080 human fibrocarcinoma tumors, were used to guide the accumulation and retention of an enzyme-responsive nanoparticle in a xenograft mouse model. The nanoparticles were prepared as micelles from amphiphilic block copolymers bearing a simple hydrophobic block, and a hydrophilic peptide brush. The polymers were end-labeled with Alexa Fluor 647 dyes leading to the formation of labeled micelles upon dialysis of the polymers from DMSO to aqueous buffer. This dye-labeling strategy allowed the presence of the retained material to be visualized via whole animal imaging in vivo, and in ex vivo organ analysis following intratumoral injection into HT-1080 xenograft tumors. We propose that the material is retained by virtue of an enzyme-induced accumulation process whereby particles change morphology from 20 nm spherical micelles to micron-scale aggregates, kinetically trapping them within the tumor. This hypothesis is tested here via an unprecedented super resolution fluorescence analysis of ex vivo tissue slices confirming a particle size increase occurs concomitantly with extended retention of responsive particles compared to unresponsive controls.

Environmental Molecular Sciences Laboratory↗

Trace Metal Imaging of Sulfate-Reducing Bacteria and Methanogenic Archaea at Single-Cell Resolution by Synchrotron X-Ray Fluorescence Imaging

Metal cofactors are required for many enzymes in anaerobic microbial respiration. This paper examined iron, cobalt, nickel, copper, and zinc in cellular and abiotic phases at the single-cell scale for a sulfate-reducing bacterium (Desulfococcus multivorans) and a methanogenic archaeon (Methanosarcina acetivorans) using synchrotron X-ray fluorescence microscopy. Relative abundances of cellular metals were also measured by inductively coupled plasma mass spectrometry. Finally, for both species, zinc and iron were consistently the most abundant cellular metals. M. acetivorans contained higher nickel and cobalt content than D. multivorans, likely due to elevated metal requirements for methylotrophic methanogenesis. Cocultures contained spheroid zinc sulfides and cobalt/copper sulfides.

59 BASIC BIOLOGICAL SCIENCES↗

Directed evolution of a monomeric, bright and photostable version of Clavularia cyan fluorescent protein: structural characterization and applications in fluorescence imaging

The arsenal of engineered variants of the GFP [green FP (fluorescent protein)] from Aequorea jellyfish provides researchers with a powerful set of tools for use in biochemical and cell biology research. The recent discovery of diverse FPs in Anthozoa coral species has provided protein engineers with an abundance of alternative progenitor FPs from which improved variants that complement or supersede existing Aequorea GFP variants could be derived. Here, we report the engineering of the first monomeric version of the tetrameric CFP (cyan FP) cFP484 from Clavularia coral. Starting from a designed synthetic gene library with mammalian codon preferences, we identified dimeric cFP484 variants with fluorescent brightness significantly greater than the wild-type protein. Following incorporation of dimer-breaking mutations and extensive directed evolution with selection for blue-shifted emission, high fluorescent brightness and photostability, we arrived at an optimized variant that we have named mTFP1 [monomeric TFP1 (teal FP 1)]. The new mTFP1 is one of the brightest and most photostable FPs reported to date. In addition, the fluorescence is insensitive to physiologically relevant pH changes and the fluorescence lifetime decay is best fitted as a single exponential. The 1.19 {angstrom} crystal structure (1 {angstrom}=0.1 nm) of mTFP1 confirms the monomeric structure and reveals an unusually distorted chromophore conformation. As we experimentally demonstrate, the high quantum yield of mTFP1 (0.85) makes it particularly suitable as a replacement for ECFP (enhanced CFP) or Cerulean as a FRET (fluorescence resonance energy transfer) donor to either a yellow or orange FP acceptor.

36 MATERIALS SCIENCE↗

Fluorescence Imaging Study of Transition in Underexpanded Free Jets

Planar laser-induced fluorescence (PLIF) is demonstrated to be a valuable tool for studying the onset of transition to turbulence. For this study, we have used PLIF of nitric oxide (NO) to image underexpanded axisymmetric free jets issuing into a low-pressure chamber through a smooth converging nozzle with a sonic orifice. Flows were studied over a range of Reynolds numbers and nozzle-exit-to-ambient pressure ratios with the aim of empirically determining criteria governing the onset of turbulence. We have developed an image processing technique, involving calculation of the standard deviation of the intensity in PLIF images, in order to aid in the identification of turbulence. We have used the resulting images to identify laminar, transitional and turbulent flow regimes. Jet scaling parameters were used to define a rescaled Reynolds number that incorporates the influence of a varying pressure ratio. An empirical correlation was found between transition length and this rescaled Reynolds number for highly underexpanded jets.

Wilkes, Jennifer A.↗

MAPX: A FULL-FIELD X-RAY FLUORESCENCE IMAGER FOR IN-SITU HABITABILITY AND BIOSIGNATURE INVESTIGATIONS

The Mapping X-ray Spectrometer (MapX)is an arm-deployed, in-situ contact instrument. MapX produces 2.5 X 2.5 cm2 elemental images and compositional Regions of Interest(ROI) with ~100 μm lateral spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or bio-logical features can be imaged and interpreted. The instrument has no moving parts and a depth of field of ±5 mm with minimal loss of resolution(so that regolith surfaces can be imaged without sample preparation). MapX can utilize 244Cm radioisotope fluorescence sources in place of X-ray tubes, reducing instrument complexity, mass and risk.

R C Walroth↗

Retrieving Tarnished Daguerreotype Content Using X-ray Fluorescence Imaging—Recent Observations on the Effect of Chemical and Electrochemical Cleaning Methods

We report a study on the effect of chemical and electrochemical cleaning of tarnished daguerreotypes observed using X-ray fluorescence (XRF) microscopy with a micro-focussed X-ray beam from a synchrotron source. It has been found that, while both techniques result in some success depending on the condition of the plate and the experimental parameters (chemical concentration, voltage, current, etc.) the effect varies, and cleaning is often incomplete. The XRF images using Hg Lα,β at an excitation energy just above the L3 edge threshold produce fine images, regardless of the treatment. This finding confirms previous observations that if the bulk of the image particles remains intact, the surface tarnish has little effect on the quality of the original daguerreotype image retrievable from XRF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗