Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flowmeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

82 records · Page 5

An on-line acoustic fluorocarbon coolant mixture analyzer for the ATLAS silicon tracker

The ATLAS silicon tracker community foresees an upgrade from the present octafluoro-propane (C{sub 3}F{sub 8}) evaporative cooling fluid - to a composite fluid with a probable 10-20% admixture of hexafluoro-ethane (C{sub 2}F{sub 6}). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C{sub 3}F{sub 8}/C{sub 2}F{sub 6} mixture ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound 'chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C{sub 3}F{sub 8}/C{sub 2}F{sub 6} flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semiconductor manufacture and anesthetic gas mixtures. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an electronic seepage chamber for extended use in a river.

Seepage chambers have been used to characterize the flux of water across the water-sediment interface in a variety of settings. In this work, an electronic seepage chamber was developed specifically for long-term use is a large river where hydraulic gradient reversals occur frequently with river stage variations. A bi-directional electronic flow meter coupled with a custom built seepage chamber was used to measure temporal changes in the magnitude and direction of water flux across the water-sediment interface. The seepage chamber is capable of measuring average specific discharge as low as 1 x 10-6 cm/s over a 15-minute period. The specific discharge measured from the seepage chamber compared favorably with measurements of vertical hydraulic gradient and vertical hydraulic conductivity measured adjacent to the seepage chamber, demonstrating the effectiveness of the electronic seepage chamber to quantify water flux in two directions over a multi-month period.

47 OTHER INSTRUMENTATION↗

Tracer Methods for Characterizing Fracture Creation in Engineered Geothermal Systems

The aim of this proposal is to develop, through novel high-temperature-tracing approaches, three technologies for characterizing fracture creation within Engineered Geothermal Systems (EGS). The objective of a first task is to identify, develop and demonstrate adsorbing tracers for characterizing interwell reservoir-rock surface areas and fracture spacing. The objective of a second task is to develop and demonstrate a methodology for measuring fracture surface areas adjacent to single wells. The objective of a third task is to design, fabricate and test an instrument that makes use of tracers for measuring fluid flow between newly created fractures and wellbores. In one method of deployment, it will be used to identify qualitatively which fractures were activated during a hydraulic stimulation experiment. In a second method of deployment, it will serve to measure quantitatively the rate of fluid flowing from one or more activated fracture during a production test following a hydraulic stimulation.

15 GEOTHERMAL ENERGY↗

Measuring the Increment in the Free Volume of Composite Components

Various methods of measuring the increment in the free volume of composite components are considered, so as to assess which is most suitable for automation of such measurements as a function of the pressure within the component. A method permitting such measurements with high precision is found, and the corresponding instrument is described.

42 ENGINEERING↗

Use of a Heat Flow Meter to Determine Active PCM Content in an Insulation

Residential and commercial roofs and walls are currently designed and tested using steady-state criteria. The resulting R-values, based on the apparent thermal conductivity, are used by building standards as an important measure of energy performance. Building envelope components, however, are subject to dynamic environmental conditions. This mismatch between the steady-state principles used in design and code requirements and their dynamic operation results in relatively low thermal efficiencies. Although several research centers have developed experimental methods for transient analysis of building envelopes, there are no standardized testing procedures available for screening materials and systems for which performance depends on dynamic response. For example, a full-scale dynamic evaluation of phase change materials (PCMs) is needed to assess their energy saving benefits. A nationally accepted small-scale (one to two foot size specimens) testing procedure is not available for the analysis of dynamic thermal characteristics of conventional thermal mass systems or PCM-enhanced materials. At the same time, data on these characteristics are necessary for whole-building simulations, energy analysis, and energy code work. The transient characteristics of PCM-enhanced products depend on the PCM content and quality. The only readily available method of thermal evaluation uses the differential scanning calorimeter. Unfortunately, this method requires small, relatively uniform test specimens. This requirement is unrealistic in the case of PCM-enhanced building envelope products such as PCM-cellulose, PCM-glass fiber, or PCM-gypsum blends. Small specimens are not representative of PCM-based blends, since these materials are not homogeneous. Jan Kosny and David Yarbrough, Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN 37831-6070. Elizabeth Kossecka, Polish Academy of Sciences, Institute of Fundamental Technological Research, Pawinskiego 5 B, 02-106, Warsaw, Poland. A procedure for making dynamic heat-flow measurements using existing instrumentation has been developed to analyze the benefits of thermal storage. This small-scale testing method is useful for thermal analysis and as a potential quality control method for producers of PCM-enhanced building materials. The research may provide the basis for consensus standard development. This paper uses as an example a dynamic testing process for PCM-enhanced cellulose insulation.

25 ENERGY STORAGE↗

Experimental and code simulation of a station blackout scenario for APR1400 with test facility ATLAS and MARS code

A SBO (station blackout) experiment named SBO-01 was performed at full-pressure IET (Integral Effect Test) facility ATLAS (Advanced Test Loop for Accident Simulation) which is scaled down from the APR1400 (Advanced Power Reactor 1400 MWe). In this study, the transient of SBO-01 is discussed and is subdivided into three phases: the SG fluid loss phase, the RCS fluid loss phase, and the core coolant depletion and core heatup phase. In addition, the typical phenomena in SBO-01 test - SG dryout, natural circulation, core coolant boiling, the PRZ full, core heat-up - are identified. Furthermore, the SBO-01 test is reproduced by the MARS code calculation with the ATLAS model which represents the ATLAS test facility. The experimental and calculated transients are then compared and discussed. The comparison reveals there was malfunction of equipments: the SG leakage through SG MSSV and the measurement error of loop flow meter. As the ATLAS model is validated against the experimental results, it can be further employed to investigate the other possible SBO scenarios and to study the scaling distortions in the ATLAS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Activities with the IELLLO Lithium-Lead Facility

Fusion power offers the prospect of an almost inexhaustible source of energy for future generations. Although this may be true, it also presents so far serious scientific and engineering challenges. Breeding Blanket is one of key components of future fusion reactors, since it directly involves tritium breeding and energy extraction, both of them critical to development of fusion power. To deal with the development of Breeding Blankets, ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development) designed and built a lead lithium loop (IELLLO: Integrated European Lead Lithium Loop): the experiment aims to support R and D activities for the conceptual and preliminary design of the European test blanket systems. IELLLO was completed, installed and operated at ENEA Brasimone Research Centre. The purpose of this work is to describe the experimental activities that have been carried out concerning the qualification of the facility, and relative instrumentations, for lead lithium applications. A series of thermo-hydraulic investigations on IELLLO facility has been elaborated: lead lithium pressure transducers, heat exchanger, permanent magnet pumping system, mass flow meters and air cooler have been tested. The absolute pressure meter in contact with Pb-16Li was qualified in pressure range up to 10 bar and temperature up to 400 deg. C. The installation of new kinds of Pb-16Li differential pressure transducers will allow to check the pump characteristic curve and accurately calculate valves pressure drops. These factors could give a better information for the thermo-hydraulic qualification of the facility. Vortex Mass Flow Meter has shown good results in terms of accuracy. The performance has been validated by thermal balance with a dedicated heating system. Nevertheless, the installations of different types of mass flow meters will enable to test IELLLO at ITER relevant conditions, and at lower mass flow rates than those tested up to now. The new pumping system with a PM Pump, was qualified for the first time in Pb-16Li, and the procedure for the operation and maintenance of the pump was developed. The pump is able to supply a mass flow rate in the range from 1.2 to 2.4 kg/s with a temperature of Pb-16Li up to 550 deg. C in the test section. Significant results have been obtained also for the heat exchanger, which has shown high efficiencies, even more than expected. Likewise, the Air Cooler has been verified to be able to cool Pb-16Li in a relatively short time, even at the worst temperature and mass flow conditions. (authors)

42 ENGINEERING↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fluid control structures in microfluidic devices

Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

42 ENGINEERING↗