Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field demonstration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

In-Situ Pipeline Coatings for Methane Emissions Mitigation and Quantification from Natural Gas Pipelines

Addressing the current health of the nation’s existing 3 million miles of pipeline infrastructure is key to preventing further climate change. In 2020, natural gas production exceeded 34 trillion cubic feet (Tcf). Roughly 75% of natural gas consists of methane (CH 4 ), which is up to 25 times more powerful than carbon dioxide (CO 2 ) at trapping heat within the atmosphere over a 100-year period, and studies from the Environmental Defense Fund (EDF) estimate approximately 2% of all the natural gas produced will be lost during normal operations due to unaddressed leaks. This does not even consider the risks of major disaster due to pipeline failure, or the losses and extra fuel costs incurred due to corrosion and scale deposits in under-maintained pipelines. The objective of the proposed research is to demonstrate the protection capabilities and economic benefits of Oceanit’s internal pipe surface treatment, known as DragX™. DragX™ is a chemically resistant, water-and-oil repellent nanocomposite system that can be readily applied in-situ on natural gas transmission and distribution pipelines with a minimum of surface preparation. This makes it an ideal candidate for in-place retrofitting and refurbishment of existing pipelines without the need for expensive extraction and replacement. DragX™ is also able to significantly reduce the surface roughness, and subsequently, the frictional drag forces within a pipeline, improving throughput, decreasing energy costs of pressurization and pumping, and allowing for longer pipeline operation without interruption, reducing the methane emitted during pipe isolation and venting. As part of this project, Oceanit has utilized the Department of Energy’s support to fully develop, de-risk and prove the DragX™ core technology is both economically viable and commercially desirable to pipeline operators and energy companies alike. DragX™ material properties were optimized in this effort both for ease of applicability, to provide value in certain key parameters, and was demonstrated on pilot applications exceeding 2 miles in length. Beyond the already field demonstrated applications, this innovative nanocomposite surface treatment has the potential to be the backbone for CO 2 and Hydrogen transporting pipeline infrastructure. The learnings from this project could accelerate the deployment of surface treatment technologies related to the energy transition infrastructure, thus benefitting the clean energy initiatives in the United States and all around the world.

03 NATURAL GAS↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the density field around a supersonic conical projectile using quantitative schlieren

Quantitative schlieren imaging is a flow measurement technique that is capable of measuring density fields throughout refractive flowfields. The technique was applied here to measure the density field surrounding supersonic conical projectiles in free flight. Shock waves attached to a supersonic conical projectile offer a simple geometry with the well-established Taylor–Maccoll analytical flow solution to which these experimental measurements were compared. The schlieren images recorded a projection of the index of refraction field surrounding the 10° half-angle cones which was converted to density first through an Abel inversion and then the Gladstone–Dale law. Three Abel inversion methods—two-point, three-point, and arbitrary ray axisymmetric projection (ARAP)—were applied to deconvolute the three-dimensional flow within the constrained axisymmetric flow field. The resulting reconstructed density profiles were compared to the Taylor–Maccoll solution, parameterized by cone geometry and Mach number. The experimental density fields demonstrated strong agreement with the theoretical profiles. Experimental consistency was confirmed across various projectile speeds, demonstrating quantitative schlieren’s capability to accurately reconstruct the density of the flow field, even within the resolution constraints imposed by high-speed imaging. In conclusion, an assessment of experimental uncertainties in the density reconstruction was performed.

Abel Inversion↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Black start demonstrations of small hydropower plants with energy storage

The U.S. has at least 500 municipal, electric co-operative, and publicly owned utilities with hydropower plants. These are mostly grid-connected to support the national grid. However, due to small size (at most 10 MW) and low ramping capacity, many of these hydropower plants lack the capability to form local grids to provide backup power to critical loads (during grid outage) and rural areas. Energy storage, such as Li-Ion batteries or ultracapacitors, can be used to enable these capabilities. Because this technology is relatively new, proof-of-concept demonstrations are needed to de-risk the approach before it can be deployed at scale. Two field demonstrations have been performed to validate this approach, namely, a 375 kVA / 1.24 kWh ultracapacitor with Idaho Falls Power’s 3.6 MW Old Lower (OL), 8.9 MW Lower Bulb (LB), and 8.9 MW City Bulb (CB) hydropower plants; and a 250 kVA / 320 kWh Li-Ion battery with Fall River Electric Cooperative’s 5.5 MW Felt hydropower plant. The Idaho Falls Power demonstration showed the resilience benefits of hybridization, and the Fall River Electric demonstration showed what the minimal requirements are to retrofit a hydropower plant for black start. These demonstrations are funded by the U.S. Department of Energy Water Power Technologies Office HydroWIRES Initiative.

13 HYDRO ENERGY↗

Evaluation of Thin Triple-Pane Windows in the PNNL Lab Homes

In recent years, improvements in glass manufacturing have allowed the production of thin triple-pane windows, which are manufactured with a thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy is sponsoring laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. To examine the performance of thin triple-pane windows, the Pacific Northwest National Laboratory (PNNL) evaluated the windows at the PNNL Lab Homes, a matched pair of homes located on PNNL’s campus in Richland, Washington. In this study, one Lab Home contained a complete set of nine thin triple-pane windows, while the other Lab Home contained baseline double-pane windows. The Lab Homes experiments demonstrated significant that replacing clear glass double-pane windows with thin triple-pane windows provided year-round energy savings and reduced peak demand both in the heating and cooling seasons. The Lab Homes experiments also validated other performance benefits of the thin triple-pane windows including reduced condensation potential, more even temperatures throughout the home and near the windows, and reduced sound attenuation through the windows, leaving the home quieter and more comfortable for the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Quantum Mechanical Treatment of Electron Broadening in Strong Magnetic Fields. II. Large Enhancements due to Exchange Interactions

We present a quantum treatment of atom–electron collisions in magnetic fields, demonstrating the significant importance of including the effect of exchange that arises from two interacting electrons. We find strange behaviors that are not encountered in collisions without a magnetic field. In high magnetic fields, exchange can lead to orders of magnitude enhancements of collision cross sections. Additionally, the elastic collision cross sections that involve the ground state become comparable to those involving excited states, and states with large orbits have the largest contribution to the collisions. We anticipate significant changes to spectral line broadening in neutron star surfaces and atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Risk-informed Hierarchical Control of Behind-the-Meter DERs with AMI Data Integration (Final Technical Report)

This project addresses several key barriers to implement the next generation demand response applications and provides a clear understanding of implementing hierarchical and standalone control using AMI data. Through this program, Eaton has developed and tested a meter-as-a-controller prototype with the help of other partners--- National Renewable Energy Laboratory (NREL), Electric Power Research Institute (EPRI), Pecan St Inc. (PSI), and Delaware Electric Cooperative (DEC). The controller can utilize residential controllable loads such as heating, ventilation, and air conditioner (HVAC), electric water heater and distributed energy resources like solar PV and battery energy storage systems for off-setting the demand that is required from the grid, thus providing reliable grid-services for demand reduction or peak shaving. The controller is also capable of coordinating the resources of the premises for better management and energy efficiency while meeting the comfort bound of the premises owner as quality-of-service. The development has been demonstrated in a three virtual-home setup at system performance lab of NREL with real appliances (HVAC, electric water heater, solar PV, and battery). The technology has also been proved through laboratory and field demonstration with successful interconnectivity (e.g., end-to-end communication and data exchange) between the residential appliances and utility through the RF network at Delaware Electric Co-op (DEC) in Delaware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Abstract for CRADA between NETL and Hope Gas, Inc.

The National Energy Technology Laboratory (NETL) and Hope Gas (PARTICIPANT) will collaborate in field demonstrations of NETL-developed methane quantification and mitigation technologies, including pipeline sensors and pipeline protection materials to mitigate methane emissions. Hope Gas will also provide access to gathering pipelines and other facilities for an NETL team to perform methane emission field survey.

03 NATURAL GAS↗

Toward Drilling the Perfect Geothermal Well: An International Research Coordination Network for Geothermal Drilling Optimization Supported by Deep Machine Learning and Cloud Based Data Aggregation

The EDGE project, supported by the U.S. Department of Energy Geothermal Technologies Office under award DE-EE0008793, established a data-driven framework for improving the efficiency, cost-effectiveness, and reliability of geothermal well drilling. The project focused on developing scalable data infrastructure, advanced machine learning and probabilistic models, and integrated analytics tools to support continuous drilling optimization. A central objective was to reduce geothermal drilling costs by up to seventy percent while minimizing the risk of well failure through predictive diagnostics and adaptive planning. Over the project period, a comprehensive data repository was designed and deployed, incorporating records from over one hundred geothermal wells across varied geological settings. This repository supported both structured and unstructured data and adhered to FAIR data principles, enabling provenance tracking, quality control, and standardized metadata. The project introduced automated ingestion pipelines and a cloud-hosted platform that facilitated access to raw, processed, and derived datasets. This infrastructure served as the foundation for model development and analysis. Machine learning workflows were developed to predict key drilling metrics including rate of penetration, non-productive time, and total drilling costs. Self-organizing maps and dimensionality reduction methods were used to uncover operational patterns and outliers, while supervised learning algorithms such as random forests and deep neural networks were applied to forecast performance outcomes. The models were validated on heterogeneous datasets from both U.S. and Icelandic fields, demonstrating variable but significant predictive accuracy. The results indicated that finer temporal resolution, inclusion of lithological data, and consistency in operational annotations could substantially improve model performance. The project also implemented process mining techniques to reconstruct state-transition models from drilling event logs. These models enabled the identification of deviations from optimal workflows and provided insights into recurring failure modes. Analysis of non-productive time highlighted the impact of equipment failures, geological challenges, and human factors, offering opportunities for targeted mitigation strategies. The EDGE Dashboard was developed as a web-based expert system integrating data visualization, model outputs, and user-driven queries. It provided an accessible interface for operators to explore historical data, evaluate predicted outcomes, and compare drilling scenarios. Initial feedback from project partners suggested that the dashboard could serve as a foundation for more advanced advisory and optimization tools. Overall, the EDGE project demonstrated the feasibility and value of applying modern data science techniques to geothermal drilling. It delivered a set of interoperable tools and models that can support more efficient, lower-risk well development. The findings point toward a viable path for transitioning from advisory analytics to semi-autonomous drilling systems, contingent on continued collaboration, expanded datasets, and field validation. The project results have immediate relevance for drilling operations, data management practices, and future geothermal R&D efforts aimed at achieving reliable, cost-competitive geothermal energy at scale.

15 GEOTHERMAL ENERGY↗

A carbon molecular sieve membrane-based reactive separation process for pre-combustion CO 2 capture

In this study, we discuss a hybrid system combining a membrane reactor (MR) and an adsorptive reactor (AR), with the MR's reject stream serving as the AR's feed. We apply this system for the water gas shift (WGS) reaction for H 2 generation and simultaneous CO 2 capture in the context of the Integrated Gas Combined Cycle (IGCC) process for power generation from coal and biomass. This MR-AR system attains a high conversion exceeding equilibrium, produces a pure H 2 product for power generation, and delivers a high-pressure CO 2 stream ready for sequestration. Specifically, in our study we use carbon molecular sieve membranes (CMSMs) and a commercial sour-shift WGS catalyst. Lab experiments were carried-out to determine the membrane characteristics, and the MR performance under IGCC-relevant conditions, i.e., for temperatures up to 250 °C and pressures up to 25 bar, employing a model coal gasifier syngas. The CMSM and the catalyst have displayed robust and stable performance during a long-term run (~750 h of syngas exposure). We evaluated the MR-AR system in multi-cycle runs and it has demonstrated superior performance to that of a conventional packed-bed reactor, producing a high-purity H 2 product directly useable in a turbine for power generation. We conclude from the study, that the CMSM-based MR-AR system is a good candidate technology for environmentally-benign power generation. We are currently constructing a pilot-scale system for field demonstration of the technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical Performance of Forced Oscillation Detectors in the Presence of Missing Measurements

In bulk power systems, measurement-based monitoring for large oscillations can help maintain system reliability. One of the challenges encountered in a recent field demonstration was the unavailability of measurements due to underlying measurement quality or communication problems. During the demonstration, the oscillation detector ignored a measurement location if even 10 seconds of data was missing. To extend the detector's ability to operate in these conditions, this paper evaluates the impact of three methods for addressing missing data. The strengths and weaknesses of each approach are evaluated using theoretical expressions for the probability of detection along with results from simulated data and publicly available field measurements. Based on these results, a suitable approach is identified that can extend the oscillation detector's performance when large segments of data are missing.

Follum, James D.↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot-spot model for inertial confinement fusion implosions with an applied magnetic field

Imposing a magnetic field on inertial confinement fusion implosions magnetizes the electrons in the compressed fuel; this suppresses thermal losses, which increases temperature and fusion yield. Indirect-drive experiments at the National Ignition Facility with 12 and 26 T applied magnetic fields demonstrate up to 40% increase in temperature, 3× increase in fusion yield, and indicate that magnetization alters the radial temperature profile [Moody et al., Phys. Rev. Lett. 129, 195002 (2022); Lahmann et al., APS DPP (2022)]. In this work, we develop a semi-analytic hot-spot model, which accounts for the two-dimensional (2D) Braginskii anisotropic heat flow due to an applied axial magnetic field. First, we show that hot-spot magnetization alters the radial temperature profile, increasing the central peakedness, which is most pronounced for moderately magnetized implosions (with 8–14 T applied field), compared to both unmagnetized (with no applied field) and highly magnetized (with 26 T or higher applied field) implosions. This model explains the trend in the experimental data, which finds a similarly altered temperature profile in the 12 T experiment. Next, we derive the hot-spot model for gas-filled (Symcap) implosions, accounting for the effects of magnetization on the thermal conduction and in changing the radial temperature (and density) profiles. Using this model, we compute predicted central temperature amplification and yield enhancement scaling with the applied magnetic field. The central temperature fits the experimental data accurately, and the discrepancy in the yield suggests a systematic (independent of applied field) degradation, such as mix, and additional degradation in the reference unmagnetized shot, such as reduced laser drive, increased implosion asymmetry, or the magnetic field suppressing ablator mixing into the hot-spot.

Alpha particles↗

Hysteretic Responses of Skyrmion Lattices to Electric Fields in Magnetoelectric Cu 2 OSeO 3

Electric field control of topologically nontrivial magnetic textures, such as skyrmions, provides a paradigm shift for future spintronics beyond current silicon-based technology. While significant progress has been made by X-ray and neutron scattering studies, direct observation of such nanoscale spin structures and their dynamics driven by external electric fields remains a challenge to understand underlying mechanisms and harness functionalities. Here, using Lorentz transmission electron microscopy combined with in situ electric and magnetic fields at liquid helium temperatures, we report the crystallographic-orientation dependent skyrmion responses to electric fields in thin slabs of magnetoelectric Cu 2 OSeO 3 . We show electric fields not only stabilize the hexagonally packed skyrmion lattices in the entire sample in a hysteretic manner but also induce the rotation of their reciprocal vector discretely by 30°. Furthermore, the nonvolatile and energy-efficient skyrmion-lattice control by electric fields demonstrated in this work provides an important foundation for designing skyrmion-based qubits and memory devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Pilot-Scale Evaluation of Natural Gas-Based Foam at Elevated Pressure and Temperature Conditions

Abstract Nitrogen (N2) and Carbon Dioxide (CO2) foams have been used as hydraulic fracturing fluids for several decades to reduce water usage and minimize damage in water-sensitive reservoirs. These foam treatments require gases to be liquefied and transported to site. An alternative approach would be to use natural gas (NG) that is readily available from nearby wells, pipelines, and processing facilities as the internal, gaseous phase to create a NG-based foam. Hydraulic fracturing with NG foam is a relatively inexpensive option, makes use of an abundant and often wasted resource, and may even provide production benefits in certain reservoirs. As part of an ongoing development project sponsored by the Department of Energy (DOE), the surface process to create NG foam is being developed and the properties of NG foam are being explored. This paper presents recent results from a rigorous pilot-scale demonstration of NG foam over a range of operating scenarios relevant to surface and bottomhole conditions with a variety of base-fluid mixtures. The Pilot-scale Foam Test Facility (PFTF) used in these investigations is first described. The PFTF is capable of generating foamed fluids at pressures up to 7,500 psig and at temperatures in excess of 300°F. Then, results from several investigations aimed at proving NG foam at conditions relevant to the field are presented. NG foam was characterized using rheology measurements and flow visualization techniques. Experiments were performed to investigate the texture and stability of NG foam generated by two different mixing methods: one using a custom designed tee to match mixing velocities in the field where the gas phase is jetted into the aqueous stream, and another to ensure comprehensive mixing for laboratory analysis. Parametric studies were conducted to explore the effects of flow rate, foam quality, and temperature on the stability of NG foam. Moreover, different fluid preparations were used to investigate the effect of base fluid and additive concentrations on the stability of NG foams. Additional laboratory studies that investigated foam stability with produced water and multicomponent NG mixtures are also reported. The NG foams explored in these investigations exhibited typical, shear-thinning behavior observed in rheological studies of N2- and CO2-based foams. The measured viscosity and observed stability indicate that NG foams are well suited for fracturing applications. Like other foams, NG foam exhibits sensitivity to operating temperature characterized by a decrease in apparent viscosity as temperature increases. Rapid foam breakdown was observed at significantly elevated temperatures exceeding 290°F. In addition to fluid characterization, these investigations also yielded several key lessons that should be applied to future field demonstrations of NG foam.

Beck, Griffin↗