Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equipment aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Advancing Transportation Efficiency and Electric Vehicles in Tonga: A Review of Relevant Trends, Best Practices, and Future Work

Tonga is facing a transportation sector characterized by private passenger vehicles, poorly maintained roads and walkways, and an inadequate public transit system. By understanding detailed global and regional trends for transport energy efficiency and electric vehicles (EVs) within this context, the Government of Tonga can proactively plan its future transportation systems. In addition to global and regional trends, this presentation also briefly examines Tonga's own transportation policies and actions. Jurisdictions leading in EV adoption have implemented policies such as reducing taxes on EVs compared to internal combustion engine (ICE) vehicles, providing subsidies and rebates for EV charger installation, instituting an age limit on imported ICE vehicles, and developing EV maintenance courses to expand the skill set of current automotive technicians. This presentation was developed for the Pacific Islands Workshop on Electric Mobility, held from November 28th to November 30th 2022 in Fiji. NREL presented virtually and the conference was sponsored by the Pacific Centre for Renewable Energy and Energy Efficiency (PCREEE).

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Thermal dissipation sensors enter a new age: Navigating frontiers in transpiration and hydrologic function

Thermal dissipation (TD) sensors have been used extensively for a wide array of sap flow applications, and yet recently several limitations of this approach have been identified, including a tendency to underestimate absolute flows, especially in small stems with very high flows. However, when used properly, the TD method remains the most cost effective and reliable approach for determining relative flows in comparison studies. Major advantages of this method include the ability to replicate maximally within trees, across trees of different sizes, and across multiple species to capture the full range of natural variation in the study system. From early studies, such variation has been deemed a major challenge for representing stand-level dynamics. In a series of recent comparison studies, we determined mean sap flux density dynamics within and among groups of trees. These studies were conducted within temperate coniferous forest (n=46), temperate oak savanna (n=36), temperate pine forest (n=49), temperate bottomland hardwood forest (n=23), tropical premontane rainforest (n=43), semiarid subtropical shrubland (n=25), and tropical dry forest (n=15), with a total of 237 sensors. Two study sites were also equipped with eddy covariance systems for determination of stand-level evapotranspiration. Sites subject to high background thermal gradients used the transient thermal dissipation method. Comparisons varied between studies but tended to focus on relative flow differences between species, between wetter and drier microsites, between understory and overstory components, or between wetter and drier periods of the growing season. Except for the shrubland sites, study trees tended to be at least 15-cm diameter and frequently exceeded 50-cm diameter. Results of this cross-site comparison highlight the inherent variation in natural stands and the importance of using large sample sizes. The TD approach remains a valuable and preferred method for the future determination of water use in trees. However, sensor replication can fundamentally impact a study's outcomes and should be more carefully considered in study design. Customized error mitigation strategies are best to address the sources of variation most problematic for a particular study. In conclusion, the development of “smart” calibration approaches that correct for fundamental effects of radial variation inherent in thermal dissipation studies is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Abnormal Level Control Oscillations in a BWR Feedwater System

In the long-term operation of nuclear power plants, the aging of systems, structures, and components can lead to maintenance issues that must be dealt with to maintain cost-effective plant operations. One common issue affecting the currently operated boiling water reactors is the onset of unexpected level oscillations in feedwater heaters. This phenomenon can cause excessive cycling of drain valves and lead to premature failures. In this work, we develop a dynamic model of a set of feedwater heaters to determine the root cause of oscillations observed in an operating plant. Simulation results of various transient scenarios were used to investigate the effects of the controller parameters, boundary conditions, and possible valve and instrument issues. The analysis led to the conclusion that the most likely causes of the observed self-sustained oscillations in the system are the nonlinear behaviors of the drain valve and the level transmitter induced by degraded equipment condition. In conclusion, a partial plug of the pressure line used for level sensing in the system can account for a significant deadtime in the level transmitter, a nonlinear effect shown to induce self-sustained oscillatory behaviors.

Boiling water reactors↗

Stakeholder Support for Wildlife Conservation Funding Policies

State wildlife management agencies in the United States have depended on a “user-pay” funding model for conservation efforts that relies on revenue from hunting license sales and a federal excise tax on firearms, ammunition, and archery equipment. Declines in hunting participation, however, jeopardize sustainability of the current funding model. Ensuring support among stakeholders for wildlife management and conservation may require expanding sources of funding and incorporating the perspectives and values of a diversifying constituency into decision making processes. We used a web-based survey of wildlife-associated recreationists in Michigan, USA to evaluate support for a range of conservation funding policies. Respondents self-identified primarily as hunters (n = 2,558) or wildlife watchers (n = 942). We used binary logistic regression to evaluate support for four conservation funding policy options: state sales tax, lottery proceeds, extractive industry revenue, and a user-based tax on outdoor gear (i.e., “backpack tax”). Determinants of support varied by type of policy and stakeholder characteristics. We found no statistically significant differences between hunters and wildlife watchers in their support for conservation funding policies when accounting for other variables such as wildlife value orientations, engagement in stewardship behaviors, age, and gender. The industry-based policy achieved the greatest level of approval, while the backpack tax had the lowest. Respondents were mixed in their support of the sales tax and lottery proceeds options. Cluster analysis revealed three homogenous groups related to conservation funding policies: “strong support,” “mixed/opposed,” and “anti-backpack tax.” Clusters differed in their support for conservation funding policies and on psychological and demographic variables. The “strong support” and “anti-backpack tax” groups differed in their levels of stewardship engagement, knowledge of conservation funding mechanisms, and support for the backpack tax option. The “mixed-opposed” group tended to be older, less educated, and less likely to be a member of a conservation organization. Results suggest support for conservation funding differs by policy type and social and psychological characteristics of stakeholders. Based on differences in policy support revealed in this study, we suggest a multi-tiered approach to funding conservation and building on support among wildlife stakeholders to mitigate the looming funding crisis for state wildlife agencies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Advancing Transportation Efficiency and Electric Vehicles in Tonga: A Review of Relevant Trends and Best Practices

Tonga is facing a transportation sector characterized by private passenger vehicles, poorly maintained roads and walkways, and an inadequate public transit system. By understanding detailed global and regional trends for transport energy efficiency and electric vehicles (EVs) within this context, the Government of Tonga can proactively plan its future transportation systems. In addition to global and regional trends, this report also covers a variety of international case studies and examines Tonga's own transportation policies and actions through this lens. Jurisdictions leading in EV adoption have implemented policies such as reducing taxes on EVs compared to internal combustion engine (ICE) vehicles, providing subsidies and rebates for EV charger installation, instituting an age limit on imported ICE vehicles, and developing EV maintenance courses to expand the skill set of current automotive technicians. Although there are key challenges and barriers to widespread EV adoption in Tonga, multiple studies have researched potential political, technical, financial, and educational interventions that can be adapted and applied in Tonga. Therefore, the purpose of this report is to synthesize the relevant trends and best practices in order to provide Tonga's Ministry of Meteorology, Energy, Information, Disaster Management, Environment, Climate Change and Communication (MEIDECC) with a wide range of information on electric vehicles (EVs) and transportation efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Community Guide to Regulatory Barriers Affecting Microgrids (Reports 1-3)

In response to growing risks of power outages from extreme weather and aging infrastructure, communities are increasingly exploring the potential of microgrids to provide reliable energy access. Microgrids offer promising solutions to meet this challenge but face a complex landscape of non-technical barriers, particularly regulations concerning the provision and distribution of energy. Most existing legal and regulatory frameworks were designed for a centralized, one-way power system, and are often poorly suited to handle systems that independently balance distributed energy resources with local load. This three-part report series provides a strategic analysis of existing regulatory and legal factors affecting microgrid deployments to help non-technical community leaders and decision-makers better understand the feasibility of a microgrid in their community. -Report No. 1: Foundational Issues Facing Microgrids details the universal policy barriers all microgrids face, including utility interconnection processes, rate structures, and local permitting. -Report No. 2: Single Property Microgrids outlines how direct asset ownership and operating behind-the-meter can bypass some regulatory oversight, using the Blue Lake Rancheria microgrid as a case study. -Report No. 3: Multi-Property Microgrids tackles the complex challenges of crossing public rights-of-way and navigating utility franchise rights, highlighting the Coventry microgrid project. The series equips decision-makers with phased frameworks to navigate financial and regulatory complexities, engage effectively with local utilities and Authorities Having Jurisdiction (AHJs), and structure successful microgrid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection

The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Therefore, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. In this paper, an overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness.

36 MATERIALS SCIENCE↗

NLR CSP Optical Facilities: Illuminating the Path Forward Through Innovation and Impact: Agreement 38490

This initiative is a multi-faceted project at the National Laboratory of the Rockies (NLR) aimed at strengthening its Concentrating Solar Power (CSP) Optical Facilities to advance the development of low-cost, high-performance materials for solar and other applications. The project's strategy is built on three pillars: strategic stakeholder engagement, diligent facility maintenance and utilization, and the development of new research capabilities. The overarching goal is to ensure the facilities remain state-of-the-art resources for industry and academia, thereby accelerating the conversion of concentrated sunlight into energy. A key driver of the project is an international Advisory Board, which provides critical guidance on research priorities and industry needs, leading to new collaborations and secured funding. This external engagement, combined with proactive outreach to industry partners, ensures the lab's work remains aligned with real-world challenges, including materials durability and performance certification. Significant efforts in facility maintenance have addressed challenges with aging infrastructure. Notable achievements include the complete refurbishment of the hail-damaged Ultra-Accelerated Weathering System (UAWS) and the successful replacement of a failing 15-year-old Lambda 1050 spectrophotometer with a new-generation model, substantially upgrading material characterization capabilities. These maintenance activities were complemented by achieving a prestigious ISO 9001:2015 certification for the Advanced Optical Materials Labs, formally recognizing the quality and reliability of NLR's measurement capabilities. Despite these successes, challenges remain, including high demand for the High Flux Solar Furnace (HFSF) and intermittent failures of other key instruments. The project has delivered major advancements in research techniques and capabilities. At the Flatirons campus, a new indoor laboratory, was established to house advanced deflectometry and photogrammetry systems for heliostat characterization. For on-sun testing, a novel, actively cooled turning mirror was developed for the HFSF, enabling more realistic testing of particle receivers and components. A collaboration with Virginia Tech successfully demonstrated the high-temperature durability of a new solar absorber coating through extensive cyclic testing. Concurrently, new modeling took place to better predict material degradation on rough, fractal surfaces. In summary, this project has systematically enhanced NLR's CSP Optical Facilities through strategic upgrades, rigorous maintenance, and stakeholder-guided research. By overcoming equipment failures, budgetary constraints, and logistical hurdles, the project has reinforced NLR's role as a central hub for CSP innovation and materials testing. Future work will focus on securing diverse funding, expanding collaborations, and continuing to provide the critical infrastructure needed to accelerate the development and deployment of next-generation technologies.

14 SOLAR ENERGY↗

Development of the Table of Initial Isolation and Protective Action Distances for the 2024 Emergency Response Guidebook

The transportation of hazardous materials creates numerous opportunities for the release of toxic substances into the environment, whether caused by traffic accidents, train derailments, equipment failures, or human error. Such releases can pose acute hazards to the general public and to emergency response personnel who are the first to arrive at the scene. To help first responders determine whether a shipment is potentially hazardous and decide what actions should be taken if a toxic spill does occur, the Emergency Response Guidebook (ERG) is published by the U.S. Department of Transportation (DOT), Transport Canada, and the Secretariat of Transport and Communications of Mexico; with contributions from Centro de Informaciòn Quìmica para Emergencias of Argentina. The most recent version is the 2024 edition of the ERG (ERG 2024), titled 2024 Emergency Response Guidebook (ERG2024). The ERG provides essential information about firefighting, spill response, and potential public health effects. For chemicals that are toxic by inhalation (TIH) and chemicals that produce TIH gases upon reaction with water (TIH by water reactivity or TIHWR), the ERG provides initial isolation distances (IIDs) and protective action distances (PADs). The IID defines the radius of the zone around the spill that should be accessed solely by people who are directly involved in emergency response. The PAD is the distance downwind of the source of the release within which persons should be either evacuated or sheltered in place, depending on the severity of the incident and the nature of the population (e.g., density, age, health).

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Phase stability, mechanical properties, and ion irradiation effects in face-centered cubic CrFeMnNi compositionally complex solid-solution alloys at high temperatures

We report two CrFeMnNi face-centered cubic complex concentrated solid-solution alloys (CSA) have been evaluated for phase stability, mechanical properties, and radiation damage effects from heavy ions. Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 were predicted by thermodynamic calculations to phase separate and maintain a single phase at 700 °C, respectively. Aging experiments at this temperature confirmed varying degrees of precipitation of a body-centered cubic phase in both Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 . The alloys showed promising strength in tensile deformation at room temperature, with yield strengths of 155 MPa and 151 MPa for Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe3 5 Mn 15 Ni 35 , respectively. At 500 °C, the yield strength of Cr 18 Fe 27 Mn 27 Ni 28 fell to 93 MPa, and to 100 MPa in Cr 15 Fe3 5 Mn 15 Ni 35 . Unlike Cr 18 Fe 27 Mn 27 Ni 28 , Cr 15 Fe 35 Mn 15 Ni 35 gained some ductility at 500 °C compared to room temperature. The two CSAs were irradiated to 75 dpa at 500 °C in the plateau region of the displacement curve using 3.7 MeV Ni 2+ ions, alongside model alloy 709 as a reference. Irradiation results produced similar densities and sizes of dislocations loops in the two CSAs compared to the reference. However, while large voids form in the plateau region of Cr 18 Fe 27 Mn 27 Ni 28 , small voids form just beyond the displacement peak of Cr 15 Fe 35 Mn 15 Ni 35 . Atom probe tomography and energy dispersive X-ray spectroscopy-equipped scanning transmission electron microscopes were used to characterize the alloys for changes in chemical distribution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Clean Condensing Gas Furnace

Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.

03 NATURAL GAS↗