A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Energy Code Field Study: Data Collection Methodology and Protocol

In support of the U.S. Department of Energy’s Commercial Buildings Energy Code Field Study, this data collection methodology and protocol provides guidance on all aspects of undertaking a compliance study, from development of a sampling plan to recruitment to code requirements and compliance checks for each energy code measure specified to be collected. The protocol also includes a data collection form that captures all key information needed for analysis of commercial energy code compliance. This methodology was developed by the Institute for Market Transformation in coordination with Pacific Northwest National Laboratory (PNNL) and the U.S. Department of Energy Building Energy Codes Program with the objective of assisting states, jurisdictions, utilities and others as they seek to measure and demonstrate compliance rates with energy codes in commercial buildings, as well as to target areas for improvement through increased energy code compliance and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set representing baseline construction practices across the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Energy Code Field Study: Data Collection Methodology and Protocol

In support of the U.S. Department of Energy’s Commercial Buildings Energy Code Field Study, this data collection methodology and protocol provides guidance on all aspects of undertaking a compliance study, from development of a sampling plan to recruitment to code requirements and compliance checks for each energy code measure specified to be collected. The protocol also includes a data collection form that captures all key information needed for analysis of commercial energy code compliance. This methodology was developed by the Institute for Market Transformation in coordination with Pacific Northwest National Laboratory (PNNL) and the U.S. Department of Energy Building Energy Codes Program with the objective of assisting states, jurisdictions, utilities and others as they seek to measure and demonstrate compliance rates with energy codes in commercial buildings, as well as to target areas for improvement through increased energy code compliance and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set representing baseline construction practices across the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing the conservative character of particle simulations: I. Canonical and noncanonical guiding center model in Boozer coordinates

The guiding center (GC) Lagrangian in Boozer coordinates for toroidally confined plasmas can be cast into canonical form by eliminating terms containing the covariant component B Ψ P of the magnetic field vector with respect to the poloidal flux function Ψ P . In an unperturbed plasma, B Ψ P can be eliminated via exact coordinate transformations, but, in general, one relies on approximations, assuming that the effect of B Ψ P is small. In this work, we are interested in the question whether Hamiltonian conservation laws are still satisfied when B Ψ P is retained in the presence of fluctuations. Considering fast ions in the presence of a shear Alfvén wave field with fixed amplitude, fixed frequency, and a single toroidal mode number n, we show that simulations using the code ORBIT with and without B Ψ P yield practically the same resonant and nonresonant GC orbits. The numerical results are consistent with theoretical analyses (presented in the appendix), which show that the unabridged GC Lagrangian with B Ψ P retained yields equations of motion that possess two key properties of Hamiltonian flows: (i) phase space conservation and (ii) energy conservation. As counter-examples, we also show cases where energy conservation (ii) or both conservation laws (i) and (ii) are broken by omitting certain small terms. When testing the conservative character of the simulation code, it is found to be beneficial to apply perturbations that do not resemble normal (eigen) modes of the plasma. The deviations are enhanced and, thus, more easily spotted when one inspects wave-particle interactions using nonnormal modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Market Driven Residential Energy Codes: Comparing Performance in a Changing Technological Environment

The research project is undertaken to better understand the changing relationship between the two basic methods of building energy code compliance – prescriptive and performance – and how those methods relate to each other with respect to advancements in building energy computer simulation standards and capabilities. The International Energy Efficiency Code (IECC) is a model code adopted by many jurisdictions across the United States. Historically, the prescriptive compliance methodology has been preferred in most jurisdictions. The prescriptive methodology requires meeting or exceeding specific efficiency minimums for each envelope component. This tends to be a simple method to teach and verify. A more involved prescriptive alternative called the Total UA alternative is sometimes used. This method requires some multiplication, summing, and comparison to compute, so it is done with a fairly simple computer program. However, advances in computer and building energy simulation technology have resulted in increased use of more detailed performance compliance methods. The performance compliance method establishes the annual energy cost threshold via hourly simulation models. The compliance threshold is determined with a comparison building model simulation with geometry similar to the proposed home and with energy feature parameters and efficiencies as specified in the IECC. This project examines relationships between the two methods of building energy code compliance, including: • Overall annual energy use based on utility bill analysis by compliance method • Code official work processes with respect to compliance methods • Gaps and issues associated with building code compliance methods • Simulated energy use difference between compliance methods • Code compliance cost as a function of compliance method • Code compliance labeling effectiveness for high performance residences • Getting to net zero energy use and net zero greenhouse gas emissions through high performance code alternatives • Electronic code permitting and compliance alternatives

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Vip1 is a kinase and pyrophosphatase switch that regulates inositol diphosphate signaling

Inositol diphosphates (PP-IPs), also known as inositol pyrophosphates, are high-energy cellular signaling codes involved in nutrient and regulatory responses. We report that the evolutionarily conserved gene product, Vip1, possesses autonomous kinase and pyrophosphatase domains capable of synthesis and destruction of D-1 PP-IPs. Our studies provide atomic-resolution structures of the PP-IP products and unequivocally define that the Vip1 gene product is a highly selective 1-kinase and 1-pyrophosphatase enzyme whose activities arise through distinct active sites. Kinetic analyses of kinase and pyrophosphatase parameters are consistent with Vip1 evolving to modulate levels of 1-IP 7 and 1,5-IP 8 . Individual perturbations in kinase and pyrophosphatase activities in cells result in differential effects on vacuolar morphology and osmotic responses. Analogous to the dual-functional key energy metabolism regulator, phosphofructokinase 2, Vip1 is a kinase and pyrophosphatase switch whose 1-PP-IP products play an important role in a cellular adaptation.

59 BASIC BIOLOGICAL SCIENCES↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2022

The purpose of this analysis is to examine the cost-effectiveness of the 2022 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1 and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2022, compared to the previous 90.1-2019 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated energy codes. This information also informs the development of future editions of Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1–2019

The purpose of this analysis is to examine the cost-effectiveness of the 2019 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1, and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2019, compared to the previous 90.1-2016 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated of energy codes. This information also informs the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Creating the Distributed Energy Resources Education Center (DEREC)

The built environment in the United States consumes 40% of the energy generated and emits roughly the same percentage of total carbon footprint. Distributed energy resources (DER), small or modular energy generation and storage technologies, present the nation with an opportunity to substantially improve those metrics while securing the nation’s energy independence. As opportunities increase for implementing such technologies, they also continue to evolve and often outpace the nation’s traditional building practices. In an effort to effectively and proactively incorporate distributed energy resources into the nation’s energy supply, Southface Energy Institute convened with national and regional partners to create the Distributed Energy Resources Education Center (DEREC). Using national model codes and their regionally amended versions as a collective starting point, the DEREC team collaborated with industry experts and identified impediments to effective implementation of DERs, developing discipline-specific curriculum to eliminate those impediments. The center, developed in collaboration with Interstate Renewable Energy Committee (IREC) and National Buildings Institute (NBI), leverages existing DER education content as well as new and dynamic training materials and online courses that collectively engage the many roles necessary for DER implementations, including designers, code officials, builders and skilled trades, and building owners who specify, inspect, build, operate, and maintain buildings with DERs.

14 SOLAR ENERGY↗

Electric Readiness in Residential Energy Code: Technical Brief

This technical brief provides requirements for electric readiness that could be incorporated into model residential energy codes. It provides background on the basis and benefits of the provisions, and model code language that can be plugged into the IECC or adapted into other energy codes. This brief has been updated to reflect changes in the 2024 IECC.

2021 IECC↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Openpronghorn

OpenPronghorn is a simulation tool specifically tailored for modeling thermal-hydraulic phenomena in advanced nuclear reactors. It is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE), an open-source platform that facilitates the development of high-performance scientific computing applications. OpenPronghorn solves the Navier-Stokes equations, which describe the conservation of mass, momentum, and energy in fluid flows, using the finite volume numerical method. The code supports a wide range of fluid flow conditions that are applicable to nuclear reactors, including incompressible and weakly compressible flows, as well as single-phase and multiphase flows. It is capable of modeling diverse flow regimes, including laminar and turbulent flows, using various turbulence models such as the standard k-epsilon models, the v2f model, and the mixing length model. For multiphase flows, OpenPronghorn employs a mixture a Eulerian modeling approach with mixture, drift-flux, and full Eulerian models, and includes open-sourced interfacial transfer correlations for drag, exchange, and heat transfer coming from the scientific literature. OpenPronghorn's modular design allows it to handle multiscale simulations, ranging from detailed Reynolds-Averaged Navier Stokes (RANS) simulations to coarse-mesh and lumped parameter models. This flexibility enables users to perform high-fidelity simulations of specific reactor components as well as system-level analyses of entire reactor circuits. The code can be coupled with other MOOSE-based tools using the MultiApp system, allowing for the transfer of coupling quantities such as mass flow rates, heat fluxes, and boundary conditions between different simulation scales. One of the main features of OpenPronghorn is the it includes built-in validation cases from the open-source scientific literature and supports the implementation of user-defined models and correlations through MOOSE's FunctorMaterial system. OpenPronghorn is designed to be computationally efficient, leveraging the SIMPLE projection method for large-scale problems, and can be run on high-performance computing systems to handle the extensive computational demands of detailed reactor simulations. Overall, OpenPronghorn is a versatile and robust tool that provides critical insights into the thermal-hydraulic behavior of advanced nuclear reactors, supporting the design, safety, and optimization of next-generation nuclear energy systems.

Retamales, Mauricio Eduardo Tano [Idaho National L↗

Scaling Up to Zero Energy Ready - and Down to 530 ft2

There is a demonstrated need for affordable housing and smaller homes. Reduced square footage new construction projects present a solution for this growing need. Completion of these types of projects is not without challenges however, as high efficiency building measures present problems with proper equipment sizing and indoor environmental quality. This case study describes the support provided by FSEC to the Manatee County Habitat for Humanity to create a small footprint home design that qualifies for Zero Energy Ready Home (ZERH) certification in Florida. Specific measures to address equipment sizing challenges, and interior air quality targets are identified among other construction elements that contribute to qualifying for ZERH certification. Discussion of the approach to meeting these challenges is informative to other efforts to build to above code standards in hot humid climates, and other regions.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Verifying Ray Tracing Amplitude Methods for Global Magnetospheric Modeling

Abstract Ray tracing is a commonly used method for modeling the propagation of electromagnetic waves in Earth's magnetosphere. To apply ray tracing results to global models of wave‐particle interaction such as energetic electron scattering, it is useful to map the discrete rays to a volume filling mesh. However, some methods have inherent losses of energy from the wave source, or do not account for the full range of wave properties within a sample volume. We have developed and tested a 3D magnetospheric ray tracing code “MESHRAY” which resolves these issues. MESHRAY uses the conservation of Poynting flux through ray triplets with finite volume to determine the local field amplitudes. Electromagnetic wave energy density from all ray data points is mapped to a mesh and verified against the wave source power for energy conservation varying time step length, number of rays, and total time steps. We find that the method is self‐consistent and numerically robust. We further investigate whether the neglect of phase information and superposition has a significant impact on the accuracy of mapping wave intensity to a mesh. We find excellent agreement between the analytic solution for waves emitted by a line source in a plane‐stratified medium and an equivalent ray tracing solution. When phase information is excluded, ray tracing reproduces an average amplitude spread over regions of coherent constructive and destructive interference. This may be an important consideration for interpolating ray tracing results of longer wavelength waves such as magnetosonic, electromagnetic ion cyclotron, or ULF waves.

79 ASTRONOMY AND ASTROPHYSICS↗

2003 Interstate 595 Vehicle Trip-Length Study

# 2003 Interstate 595 Vehicle Trip-Length Study The 2003 Vehicle Trip-Length Study focused on Interstate 595 between Davie Road and University Drive in Florida. Survey participants answered questions about their trip's origin and destination—including the type of location such as work, home, store, etc.—the on- and off-ramps used, how many people were in the car, and the type of vehicle. The survey also collected household demographic data such as annual household income, available vehicles, the number of people living in their household, and the number of workers in their household above the age of 16. It also asked if they would use proposed bus-only lanes or train service along the corridor, if available. ## Data Collection Agency The survey was conducted by and for the Florida Department of Transportation. ## Survey Methodology The survey was conducted via mail and online in March 2003. ## Survey Records, Data, and Documentation Survey records include 7,917 participants. Origin and destination locations include street addresses, nearest intersections or landmarks, city, state, zip code, and latitude/longitude.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2003 Interstate 595 Vehicle Trip-Length Study

# 2003 Interstate 595 Vehicle Trip-Length Study The 2003 Vehicle Trip-Length Study focused on Interstate 595 between Davie Road and University Drive in Florida. Survey participants answered questions about their trip's origin and destination—including the type of location such as work, home, store, etc.—the on- and off-ramps used, how many people were in the car, and the type of vehicle. The survey also collected household demographic data such as annual household income, available vehicles, the number of people living in their household, and the number of workers in their household above the age of 16. It also asked if they would use proposed bus-only lanes or train service along the corridor, if available. ## Data Collection Agency The survey was conducted by and for the Florida Department of Transportation. ## Survey Methodology The survey was conducted via mail and online in March 2003. ## Survey Records, Data, and Documentation Survey records include 7,917 participants. Origin and destination locations include street addresses, nearest intersections or landmarks, city, state, zip code, and latitude/longitude.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2003 Interstate 595 Vehicle Trip-Length Study

# 2003 Interstate 595 Vehicle Trip-Length Study The 2003 Vehicle Trip-Length Study focused on Interstate 595 between Davie Road and University Drive in Florida. Survey participants answered questions about their trip's origin and destination—including the type of location such as work, home, store, etc.—the on- and off-ramps used, how many people were in the car, and the type of vehicle. The survey also collected household demographic data such as annual household income, available vehicles, the number of people living in their household, and the number of workers in their household above the age of 16. It also asked if they would use proposed bus-only lanes or train service along the corridor, if available. ## Data Collection Agency The survey was conducted by and for the Florida Department of Transportation. ## Survey Methodology The survey was conducted via mail and online in March 2003. ## Survey Records, Data, and Documentation Survey records include 7,917 participants. Origin and destination locations include street addresses, nearest intersections or landmarks, city, state, zip code, and latitude/longitude.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2003 Interstate 595 Vehicle Trip-Length Study

# 2003 Interstate 595 Vehicle Trip-Length Study The 2003 Vehicle Trip-Length Study focused on Interstate 595 between Davie Road and University Drive in Florida. Survey participants answered questions about their trip's origin and destination—including the type of location such as work, home, store, etc.—the on- and off-ramps used, how many people were in the car, and the type of vehicle. The survey also collected household demographic data such as annual household income, available vehicles, the number of people living in their household, and the number of workers in their household above the age of 16. It also asked if they would use proposed bus-only lanes or train service along the corridor, if available. ## Data Collection Agency The survey was conducted by and for the Florida Department of Transportation. ## Survey Methodology The survey was conducted via mail and online in March 2003. ## Survey Records, Data, and Documentation Survey records include 7,917 participants. Origin and destination locations include street addresses, nearest intersections or landmarks, city, state, zip code, and latitude/longitude.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗