Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 先生 (SENSEI†) Experiment: sub-GeV dark matter searches with skipper-CCD

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating LArPix for TinyTPC

LArTPCs provide sensitivity to GeV signals, such as accelerator neutrinos and part of the supernova neutrino spectrum. TinyTPC is a LArTPC test stand for R&D of LAr doping to expand the reach of LArTPCs down to the 1-10 MeV range, which would substantially enhance the flagship analyses of experiments like DUNE, while enabling low energy analyses. We aim to dope LAr with Xe and pho- tosensitive dopants to expand the LArTPC range by converting hard-to-detect scintillation light to efficiently detected ionization charge. A critical element of the data analysis in TinyTPC is calibrating the readout. This poster will cover the calibration of TinyTPC, a pixelated liquid argon detector, where we find the distance a muon travels through each pixel. We then calculate the energy loss of muons traveling through the detector from cosmic data. We can reconstruct the path of the particles through the TPC using a density-based clustering algorithm designed to sort straight cosmic muon tracks from low energy radioactive decay curled paths and electronic noise

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

The SENSEI Experiment: sub-GeV dark matter searches with skipper-CCDs

Skipper-CCDs are pixeled Silicon-based detectors that can perform multiple non-disruptive measurements of the same charge package. Their sub-electron resolution allows the detection of eV energy transfers, such as that expected from ultra-light dark matter interacting with electrons in a Silicon target. SENSEI (Sub-Electron Noise Skipper Experimental Instrument) is the first experiment to use Skipper-CCD for this purpose and to publish world-leading results using this technology. In this talk, we present an overview of the SENSEI experiment and the current status after the successful commissioning of the second batch of science-grade sensors at SNOLAB. We will also discuss the prospects in rare-events searches with skipper-CCDs: from SENSEI’s 100 g detector to OSCURA’s 10 kg array, and more.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting Radio Frequency Resonators for Quantum Computing: A Short Review

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high-quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. Here, we present a short review of current microwave technology used in quantum computers and progress towards the 3D resonators to enhance thecoherence time.

Dhakal, Pashupati↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a rotating gravity gradiometer for earth orbit applications (AAFE)

Some preliminary mission studies are described along with the design, fabrication, and test of a breadboard model of an earth orbital, rotating gravity gradiometer with a design goal of 10 to the minus 11th power/sec sq (0.01 EU) in a 35-sec integration time. The proposed mission uses a Scout vehicle to launch one (or two orthogonally oriented) spin-stabilized satellites into a 330-km circular polar orbit some 20 days before an equinox. During the short orbital lifetime, the experiment would obtain two complete maps of the gravity gradient field with a resolution approaching 270 km (degree 75). The breadboard model of the gradiometer demonstrated a combined thermal and electronic noise threshold of 0.015 EU per data channel. The design changes needed to reduce the noise to less than 0.01 EU were identified. Variations of the sensor output signal with temperature were experimentally determined and a suitable method of temperature compensation was developed and tested. Other possible error sources, such as sensor interaction with satellite dynamics and magnetic fields, were studied analytically and shown to be small.

Forward, R. L.↗

A fine pointing system for the large space telescope

The large space telescope (LST) developed by NASA requires ultrahigh pointing stability within 0.0005 arc sec rms. A fine guidance system is proposed to body-point the entire spacecraft within this limit. The spacecraft is modeled as a rigid body having reaction wheel actuators and subject to gravitational and magnetic disturbance torques. The fine guidance sensor is cluttered with electronic noise. The disturbance accommodation standard deviation optimal controller (DASOC) is designed to be optimal with respect to the transient and the steady state response to noise, whereas the steady state response to deterministic external torques is exactly zero. Compared with conventional controllers, the fine guidance system with the DASOC offers as much as a factor of 30 improvement in pointing stability, resulting in an optimal performance of nearly 0.0001 arc sec rms. Thus, the required pointing stability can easily be obtained, and a large margin remains for the compensation of possibile deteriorations.

Schiehlen, W. O.↗

Collisionless shock waves in space - A very high beta structure

Measurements from six OGO-5 particle and field experiments are used to examine the structure of the earth's bow shock during a period of extremely high beta (the ratio of plasma thermal to magnetic energy density), as determined from simultaneous measurements of the upstream plasma on board the HEOS satellite. Even though the interplanetary field is nearly perpendicular to the shock normal, the shock is extremely turbulent. Large field increases are observed up to a factor of 20 above the upstream values. Ahead of these large enhancements, smaller magnetic effects accompanied by electrostatic noise, electron heating, and ion deflection are observed for several minutes. These observations suggest that a steady-state shock may not be able to form at very high beta. Further, they show that while the magnetic energy density may be relatively unimportant in the upstream flow, it can become very significant within the shock structure, and hence the magnetic field should not be ignored in theoretical treatments of very high beta shocks.

Formisano, V.↗

NASA NR hydrogen maser

The Johns Hopkins University, Applied Physics Laboratory, under contract to NASA/Goddard Space Flight Center, is engineering a new generation of field operable hydrogen masers (NR) based on prior NASA NP and NX designs. These units incorporate improvements in magnetic shielding, lower noise electronics, better thermal control and have a microprocessor for operation, monitoring and diagnostic functions. They are ruggedly built for transportability and ease of service anywhere in the world.

Rueger, L. J.↗

The performance of NASA research hydrogen masers

Field operable hydrogen masers based on prior maser designs are presented. These units incorporate improvements in magnetic shielding, lower noise electronics, better thermal control, and have a microprocessor for operation, monitoring, and diagnostic functions. They are ruggedly built for transportability and ease of service anywhere in the world.

Reinhardt, V. S.↗

Aliasing and blurring in 2-D sampled imagery

The quality of image reconstructions from discrete data suffers not only from the blurring of spatial detail caused by limitations in the spatial frequency response of electrooptical systems, but also from the aliasing generated if spatial detail has been undersampled. Previous studies have observed that reasonable spot intensity profiles and photosensor aperture shapes of equivalent size result in about equal blurring but that some profiles and shapes suppress aliasing better than others. This paper presents quantitative results of the magnitude of aliasing and blurring as a function of random radiance fields typical for natural scenes and of spatial responses and sampling intervals typical for TV cameras and optical-mechanical scanners. These results indicate that aliasing may often be a larger source of degradation than either blurring or electronic noise.

Huck, F. O.↗

Room-temperature mercuric iodide spectrometry for low-energy X-rays

A discussion of the limits of energy resolution in different energy ranges is given. The energy resolution of a spectrometer is analyzed in terms of the parameters characterizing the crystal, the detector, and the amplification electronics. A high-resolution room-temperature HgI2 spectrometry system was used to measure low-energy X-ray fluorescence spectra. For the MgK-alpha X-ray line the measured resolution was 245 eV (fwhm); the electronic noise linewidth of the system was 225 eV. Alpha-particles were used to excite X-ray fluorescence from low-Z elements separately or in combination. The shape of the photopeaks in the spectra is discussed.

Kusmiss, J. H.↗

Designs for surge immunity in critical electronic facilities

In recent years, Federal Aviation Administration (FAA) embarked on a program replacing older tube type electronic equipment with newer solid state equipment. This replacement program dramatically increased the susceptibility of the FAA's facilities to lightning related damages. The proposal is presented of techniques which may be employed to lessen the susceptibility of new FAA electronic facility designs to failures resulting from lightning related surges and transients as well as direct strikes. The general concept espoused is one of a consistent system approach employing both perimeter and internal protection. It compares the technique presently employed to reduce electronic noise with other techniques which reduce noise while lowering susceptibility to lightning related damage. It is anticipated that these techniques will be employed in the design of an Air Traffic Control Tower in a high isokeraunic area. This facility would be subjected to rigorous monitoring over a multi-year period to provide quantitative data hopefully supporting the advantage of this design.

Roberts, Edward F., Jr.↗

Neural network architecture for crossbar switch control

A Hopfield neural network architecture for the real-time control of a crossbar switch for switching packets at maximum throughput is proposed. The network performance and processing time are derived from a numerical simulation of the transitions of the neural network. A method is proposed to optimize electronic component parameters and synaptic connections, and it is fully illustrated by the computer simulation of a VLSI implementation of 4 x 4 neural net controller. The extension to larger size crossbars is demonstrated through the simulation of an 8 x 8 crossbar switch controller, where the performance of the neural computation is discussed in relation to electronic noise and inhomogeneities of network components.

Troudet, Terry P.↗

Report of the sensor readout electronics panel

The findings of the Sensor Readout Electronics Panel are summarized in regard to technology assessment and recommended development plans. In addition to two specific readout issues, cryogenic readouts and sub-electron noise, the panel considered three advanced technology areas that impact the ability to achieve large format sensor arrays. These are mega-pixel focal plane packaging issues, focal plane to data processing module interfaces, and event driven readout architectures. Development in each of these five areas was judged to have significant impact in enabling the sensor performance desired for the Astrotech 21 mission set. Other readout issues, such as focal plane signal processing or other high volume data acquisition applications important for Eos-type mapping, were determined not to be relevant for astrophysics science goals.

Fossum, Eric R.↗