Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Unveiling and Driving Hidden Resonances with High-Fluence, High-Intensity X-Ray Pulses

We show that high fluence, high-intensity x-ray pulses from the world's first hard x-ray free-electron laser produce nonlinear phenomena that differ dramatically from the linear x-ray-matter interaction processes that are encountered at synchrotron x-ray sources. We use intense x-ray pulses of sub-10-fs duration to first reveal and subsequently drive the 1s{r_reversible}2p resonance in singly ionized neon. This photon-driven cycling of an inner-shell electron modifies the Auger decay process, as evidenced by line shape modification. Our work demonstrates the propensity of high-fluence, femtosecond x-ray pulses to alter the target within a single pulse, i.e., to unveil hidden resonances, by cracking open inner shells energetically inaccessible via single-photon absorption, and to consequently trigger damaging electron cascades at unexpectedly low photon energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low energy electron beam induced damage on InGaN/GaN quantum well structure

In this paper, low energy electron beam (5-20 keV, 0-500 {mu}As/cm{sup 2}) induced damage on a GaN/InGaN/GaN near-surface quantum well structure is studied. Exposure to low energy electron beam is shown to significantly reduce the optical quality of the structure. It is also observed that reducing the electron beam energy causes larger PL intensity reduction. This can be explained by considering the beam penetration depth, which is shown to be smaller with lower e-beam energies. The damage is believed to be attributed to enhanced dislocation mobility upon low energy electron beam irradiation. However, further studies are needed to confirm the mechanism. These results should be taken into consideration in low energy electron beam related sample characterization and preparation.

36 MATERIALS SCIENCE↗

Spark Channel Dynamics of Electrostatic Discharges

When two differently-charged objects are brought in close proximity to each other, the resulting high electric fields can cause electron avalanche breakdown of the air gap separating the objects, a process known as electrostatic discharge (ESD). If enough initial charge is stored on the objects, the electrical breakdown can proceed to ionize the air to such a degree that a highly conductive filament of plasma forms in the gap, known as a spark channel. The spark electrically bridges the air gap, resulting in a rapid pulse of current that neutralizes the charge difference. The current pulse produces significant heating of the gas in the spark, resulting in dissociation, ionization, thermal radiation, and hydrodynamic expansion. ESD presents a hazard to electrically-sensitive devices, with consequences such as economic losses (e.g. damaged electronics) or unsafe response (e.g. unintended ignition of flammable gas mixtures, initiation of detonators, etc.). For this thesis, the ESD spark is taken to occur between two conducting electrodes, with the spark channel being axisymmetric in a cylindrical coordinate system centered on the channel. An RLC-type circuit is used for the discharge model of the ESD event. The spark is treated as a time-dependent resistance that is in series with a capacitance, an inductance, and (optionally) a load resistance representing a “victim” component under threat from the ESD event. The primary motivation of this work is to use a numerical hydrodynamic model to understand the energy dissipation and transport processes in the spark. The model consists of the compressible Euler equations of mass, momentum, and energy conservation together with an Eddington/P1 approximation for thermal radiation transport. To close the hydrodynamic system, an equation of state (EOS) was fitted from tabular data for air that accounts for the dissociation and ionization of air species. The hydrodynamic equations are solved using a conservative Lagrangian finite volume method. These partial differential equations are coupled to the circuit equations by calculation of the spark resistance via numerical integration of the electrical conductivity of the channel. Computational results are compared against experimental measurements of discharge current and radial density of the spark channel.

42 ENGINEERING↗

Correlation between energy deposition and molecular damage from Auger electrons: A case study of ultra-low energy (5–18 eV) electron interactions with DNA

Purpose: The present study introduces a new method to establish a direct correlation between biologically related physical parameters (i.e., stopping and damaging cross sections, respectively) for an Auger-electron emitting radionuclide decaying within a target molecule (e.g., DNA), so as to evaluate the efficacy of the radionuclide at the molecular level. These parameters can be applied to the dosimetry of Auger electrons and the quantification of their biological effects, which are the main criteria to assess the therapeutic efficacy of Auger-electron emitting radionuclides. Methods: Absorbed dose and stopping cross section for the Auger electrons of 5–18 eV emitted by{sup 125}I within DNA were determined by developing a nanodosimetric model. The molecular damages induced by these Auger electrons were investigated by measuring damaging cross section, including that for the formation of DNA single- and double-strand breaks. Nanoscale films of pure plasmid DNA were prepared via the freeze-drying technique and subsequently irradiated with low-energy electrons at various fluences. The damaging cross sections were determined by employing a molecular survival model to the measured exposure–response curves for induction of DNA strand breaks. Results: For a single decay of{sup 125}I within DNA, the Auger electrons of 5–18 eV deposit the energies of 12.1 and 9.1 eV within a 4.2-nm{sup 3} volume of a hydrated or dry DNA, which results in the absorbed doses of 270 and 210 kGy, respectively. DNA bases have a major contribution to the deposited energies. Ten-electronvolt and high linear energy transfer 100-eV electrons have a similar cross section for the formation of DNA double-strand break, while 100-eV electrons are twice as efficient as 10 eV in the induction of single-strand break. Conclusions: Ultra-low-energy electrons (<18 eV) substantially contribute to the absorbed dose and to the molecular damage from Auger-electron emitting radionuclides; hence, they should be considered in the dosimetry calculation of such radionuclides. Moreover, absorbed dose is not an appropriate physical parameter for nanodosimetry. Instead, stopping cross section, which describes the probability of energy deposition in a target molecule can be an appropriate nanodosimetric parameter. The stopping cross section is correlated with a damaging cross section (e.g., cross section for the double-strand break formation) to quantify the number of each specific lesion in a target molecule for each nuclear decay of a single Auger-electron emitting radionuclide.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam-machine Interaction at the CERN LHC

The radiation field generated by a high energy and intensity accelerator is of concern in terms of element functionality threat, component damage, electronics reliability, and material activation, but also provides signatures that allow actual operating conditions to be monitored. The shower initiated by an energetic hadron involves many different physical processes, down to slow neutron interactions and fragment de-excitation, which need to be accurately described for design purposes and to interpret operation events. The experience with the transport and interaction Monte Carlo code FLUKA at the Large Hadron Collider (LHC), operating at CERN with 4 TeV proton beams (and equivalent magnetic rigidity Pb beams) and approaching nominal luminosity and energy, is presented. Design, operation and upgrade challenges are reviewed in the context of beam-machine interaction account and relevant benchmarking examples based on radiation monitor measurements are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elimination of Radio-Frequency Noise by Identifying and Diverting Large RF Ground Currents

The problem of electromagnetic interference in scientific instruments is compounded for high-power plasma experiments by the large currents and voltages as well as by the broad bandwidths of the instruments. Ground loops are known to allow stray magnetic fields to drive large ground currents that can induce spurious signals and damage electronics. Furthermore, even when a ground loop is broken, capacitive coupling can still permit the flow of radio-frequency current, resulting in high-frequency spurious signals that can overwhelm the desired signal. We present the effects of RF ground loops on the output of vacuum photodiodes used in the Caltech Solar Loop Experiment and demonstrate the elimination of the spurious signals by diverting the ground currents away from the most vulnerable point of the signal line. Techniques for identifying the RF ground loops are also discussed. These techniques should be valuable in many high-power systems where interference from spurious coupling is an issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Secure Data Transfer Guidance for Industrial Control and SCADA Systems

This document was developed to provide guidance for the implementation of secure data transfer in a complex computational infrastructure representative of the electric power and oil and natural gas enterprises and the control systems they implement. For the past 20 years the cyber security community has focused on preventative measures intended to keep systems secure by providing a hard outer shell that is difficult to penetrate. Over time, the hard exterior, soft interior focus changed to focus on defense-in-depth adding multiple layers of protection, introducing intrusion detection systems, more effective incident response and cleanup, and many other security measures. Despite much larger expenditures and more layers of defense, successful attacks have only increased in number and severity. Consequently, it is time to re-focus the conventional approach to cyber security. While it is still important to implement measures to keep intruders out, a new protection paradigm is warranted that is aimed at discovering attempted or real compromises as early as possible. Put simply, organizations should take as fact that they have been, are now, or will be compromised. These compromises may be intended to steal information for financial gain as in the theft of intellectual property or credentials that lead to the theft of financial resources, or to lie silent until instructed to cause physical or electronic damage and/or denial of services. This change in outlook has been recently confirmed by the National Security Agency [19]. The discovery of attempted and actual compromises requires an increased focus on monitoring events by manual and/or automated log monitoring, detecting unauthorized changes to a system's hardware and/or software, detecting intrusions, and/or discovering the exfiltration of sensitive information and/or attempts to send inappropriate commands to ICS/SCADA (Industrial Control System/Supervisory Control And Data Acquisition) systems.

03 NATURAL GAS↗

Effects of electron irradiation and temperature on 1 ohm-cm and 10 ohm-cm silicon solar cells

One OHM-cm and 10 OHM-cm silicon solar cells were exposed to 1.0 MeV electrons at a fixed flux of 10 to the 11th power e/sq cm/sec and fluences of 10 to the 13th power, 10 to the 14th power and 10 to the 15th power e/sq.cm. 1-V curves of the cells were made at room temperature, - 63 C and + or - 143 C after each irradiation. A value of 139.5 mw/sq cm was used as AMO incident energy rate per unit area. The 10 OHM-cm cells appear more efficient than 1 OHM-cm cells after exposure to a fluence greater than 10 to the 14th power e/sq cm. The 1.0 MeV electron damage coefficients for both 1 OHM-cm and 10 OHM-cm cells are somewhat less than those for previously irradiated cells at room temperature. The values of the damage coefficients increase as the cell temperatures decrease. Efficiencies pertaining to maximum power output are about the same as those of n on p silicon cells evaluated previously.

Nicoletta, C. A.↗

Assessment of risk due to the use of carbon fiber composites in commercial and general aviation

The development of a national risk profile for the total annual aircraft losses due to carbon fiber composite (CFC) usage through 1993 is discussed. The profile was developed using separate simulation methods for commercial and general aviation aircraft. A Monte Carlo method which was used to assess the risk in commercial aircraft is described. The method projects the potential usage of CFC through 1993, investigates the incidence of commercial aircraft fires, models the potential release and dispersion of carbon fibers from a fire, and estimates potential economic losses due to CFC damaging electronic equipment. The simulation model for the general aviation aircraft is described. The model emphasizes variations in facility locations and release conditions, estimates distribution of CFC released in general aviation aircraft accidents, and tabulates the failure probabilities and aggregate economic losses in the accidents.

Fiksel, J.↗

Discovery of vapor deposits in the lunar regolith

Lunar soils contain micrometer-sized mineral grains surrounded by thin amorphous rims. Similar features have been produced by exposure of pristine grains to a simulated solar wind, leading to the widespread belief that the amorphous rims result from radiation damage. Electron microscopy studies show, however, that the amorphous rims are compositionally distinct from their hosts and consist largely of vapor-deposited material generated by micrometeorite impacts into the lunar regolith. Vapor deposits slow the lunar erosion rate by solar wind sputtering, influence the optical properties of the lunar regolith, and may account for the presence of sodium and potassium in the lunar atmosphere.

Keller, Lindsay P.↗

Triboelectric Charging in Simulated Mars Environment

Triboelectric charging of nonconducting materials followed by sudden electrostatic discharge (ESD) can damage electronic equipment and become ignition hazard to combustible materials. Mars atmosphere has near zero humidity and therefore natural charge bleeding to surroundings is anticipated to be limited. Potential mitigation of ESD problems has been conjectured based upon strong extraterrestrial radiation on Mars compared to earth. A hypothesis was formulated that ESD problem is less significant in simulated Mars condition since strong radiation and presence of argon will generate an ionized environment; this will be conducive to rapid bleeding of static charge into the surroundings.

Lee, R.↗

Charge-Dissipative Electrical Cables

Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

Kolasinski, John R.↗

The damage equivalence of electrons, protons, alphas and gamma rays in rad-hard MOS devices

This paper reports on a study of damage equivalence in rad-hard MOS devices with 100,000 rads (SiO2) capability. Damage sensitivities for electrons of 1, 2, 3, 5, and 7 MeV, protons of 1, 3, 7, 22, and 40 MeV, 3.4-MeV alphas, and Co-60 gammas were measured and compared. Results indicated that qualitatively the same charge recombination effects occurred in hard oxide devices for doses of 100,000 rads (SiO2) as in soft oxide parts for doses of 1 to 4 krads (SiO2). Consequently, damage equivalency or non-equivalency depended on radiation type and energy. However, recovery effects, both during and after irradiation, controlled relative damage sensitivity and its dependency on total dose, dose rate, supply bias, gate bias, radiation type, and energy. Correction factors can be derived from these data or from similar tests of other hard oxide type, so as to properly evaluate the combined effects of the total space environment.

Stassinopoulos, E. G.↗

Radiation damage effects by electrons, protons, and neutrons in Si/Li/ detectors.

The degradation in performance of lithium-compensated silicon nuclear particle detectors induced by irradiation at room temperature with 0.6-MeV and 1.5-MeV electrons, 1.9-MeV protons, and fast neutrons from a plutonium-beryllium source has been investigated. With increasing fluence, the irradiations produced an increase of detector leakage current, noise, capacitance, and a degradation in the performance of the detector as a charged-particle energy spectrometer. Following the irradiations, annealing effects were observed when the detectors were reverse-biased at their recommended operating voltages. Upon removal of bias, a continuous degradation of detector performance characteristics occurred. Detectors which had been damaged by electrons and protons exhibited a stabilization in their characteristics within two weeks after irradiation, whereas detectors damaged by neutrons had a continuous degradation of performance over a period of several months.

Liu, Y. M.↗