Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Calculation of secondary electron trajectories in multistage depressed collectors for microwave amplifiers

Computational procedures are reported for treating power losses due to secondary electrons in multistage depressed collectors (MDC) for traveling wave tubes (TWT) and other O-type electron tubes. The MDC is modeled with an advanced, multidimensional computer program. Representative beams of secondary electrons are then injected at the points of impact of the primary beams. Separate programs are used to calculate representative beams of high-energy primary electron beams and of low-energy true secondaries. The recomputation of the MDC model including the true secondary beam allows determination of the secondary emission losses, and, if necessary, redesign of the MDC to improve performance. Recomputation of the MDC model including the primary beams is used to check on possible backstreaming from the MDC to the RF interaction structure of the tube. A comparison with experimentally measured values of TWT and MDC efficiencies is made.

Force, Dale A.↗

Removal of a glowing spot from an image tube using laser radiation.

A troublesome problem with the Kron electronograph has been the presence of a white glowing spot on the glass wall of the tube adjacent to the focus electrode. The procedure followed to eliminate the spot was to operate in the dark and apply voltage only to the focused electrode. Ruby laser radiation was unfocused, and its position was shifted on the electrode between laser shots until an effect was observed. This technique for removing the glowing spot should be applicable to other electronic image tubes.

Gurski, T. R.↗

Proof-of-Principle Design of a High-Field Overpass/Underpass Nb 3 Sn Dipole

A block coil geometry is appealing in the body of particle accelerator dipole or quadrupole magnets, but less so in the ends of conventional designs, because conductors near the midplane of the beam tube must be bent in the hard direction to cross over to the other side of the tube. In order to avoid damage to brittle conductors such as Nb 3 Sn or HTS, the bend must be very gradual, resulting in undesirably long magnet ends. An alternative design -"overpass/underpass" or "cloverleaf" - can ramp the conductor within a short length with bending only in the easy direction. Described here is a proof-of-principle design and analysis of an "overpass/underpass" coil geometry for a block coil dipole of 11 Tor more.

47 OTHER INSTRUMENTATION↗

Recent Progress in Developing Nb 3 Sn Conductors With Increased Specific Heat

A possible approach to reducing Nb 3 Sn magnet training is to increase the energy margin of Nb 3 Sn conductors by enhancing their specific heat (C p ). For this study, we have been developing Nb 3 Sn conductors with increased C p by incorporating substances with high C p at 2-10 K based on a conductor design that is compatible with standard Nb 3 Sn strand production. In the past couple of years our efforts have been mainly focused on improving strand design (e.g., position of high- C p filaments, thickness of the Cu tube for the high-C p filaments, ratio of the Cu powder to the high-C p substance, filament spacing, etc.) in order to obtain good strand drawability and to reduce degradation after rolling, which is needed for production of Rutherford cables. We also tried a new high-C p substance, Gd 2 O 2 S, and verified that it has much higher C p over the whole magnetic field range than the Gd 2 O 3 we used before. With that development work we can now produce high-C p strands with good drawability and low levels of degradation after rolling. This paper reports our findings and the current status of the development of high-C p Nb 3 Sn conductors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction of a New MgB 2 Coating System for 1.3-GHz Superconducting RF Cavities at LANL

After many years of evaluating MgB 2 films prepared with various techniques for the application to superconducting radio-frequency (SRF) cavities, we have decided to build a system to coat full-size 1.3-GHz elliptical cavities. This paper describes the design and construction of the system. Additionally, we briefly describe experimental results with a small system and first tests with the new large system. In conclusion, we were able to obtain superconducting samples with a T c of up to 38 K with the small system, but we have not been able to get any superconducting samples with the new system yet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron-image intensifier

Electronic intensifier tube with a demagnification ratio of 9-1 enhances the usefulness of neutron-radiographic techniques. A television signal can be obtained by optical coupling of a small-output phosphor-light image to a television camera.

Berger, H.↗

Electronic magnification for astronomical camera tubes

Definitions, test schemes, and analyses used to provide variable magnification in the image section of the television sensor for large space telescopes are outlined. Experimental results show a definite form of magnetic field distribution is necessary to achieve magnification in the range 3X to 4X. Coil systems to establish the required field shapes were built, and both image intensifiers and camera tubes were operated at high magnification. The experiments confirm that such operation is practical and can provide satisfactory image quality. The main problem with such a system was identified as heating of the photocathode due to concentration of coil power dissipation in that vicinity. Suggestions for overcoming this disadvantage are included.

Vine, J.↗

High-Speed Laser Anemometer

New high-speed laser anemometer system rapidly and efficiently maps gas-flow velocities within rotating blade rows of turbomachinery. Small seed particles entrained in gas flow fluoresce when they pass through probe volume, which is the fringe pattern formed by intersecting laser beams. Transit time of particles is obtained by use of suitable optics, photomultiplier tube and electronic signal processor. Data are then sent to a minicomputer.

Powell, J. A.↗

The phototron: A light to RF energy conversion device

The phototron, a photoelectric device that converts light to radio frequency energy, is described. It is a vacuum tube, free electron, device that is mechanically similar to a reflex klystron with the hot filament cathode replaced by a large area photocathode. The device can operate either with an external voltage source used to accelerate the photoelectrons or with zero bias voltage; in which case the photokinetic energy of the electrons sustains the R.F. oscillations in the tuned R.F. circuit. One basic design of the phototron was tested. Frequencies as high as about 1 GHz and an overall efficiency of about 1% in the biased mode were obtained. In the unbiased mode, the frequencies of operation and efficiences are considerably lower. Success with test model suggests that considerable improvements are possible through design refinements. One such design refinement is the reduction of the length of the electron flight path.

Freeman, J. W.↗

Eddy-current inspection of shuttle heat exchanger tube welds

The goal of this project was to develop the system necessary to demonstrate in the laboratory that an eddy current system can inspect the tubes and welds described, screening for the existence of flaws equal in size to, or larger than, the target flaw. The laboratory system was to include the probe necessary to traverse the tubing, the electronics to drive (i.e., electrically excite) the probe and receive and process signals from it, a data display, data recording, and playback devices, and microprocessor software or firmware necessary to operate the system.

Dodd, Casius V.↗