Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Analysis of rocket beacon transmissions for computerized reconstruction of ionospheric densities

Three methods are described to obtain ionospheric electron densities from transionospheric, rocket-beacon TEC data. First, when the line-of-sight from a ground receiver to the rocket beacon is tangent to the flight trajectory, the electron concentration can be obtained by differentiating the TEC with respect to the distance to the rocket. A similar method may be used to obtain the electron-density profile if the layer is horizontally stratified. Second, TEC data obtained during chemical release experiments may be interpreted with the aid of physical models of the disturbed ionosphere to yield spatial maps of the modified regions. Third, computerized tomography (CT) can be used to analyze TEC data obtained along a chain of ground-based receivers aligned along the plane of the rocket trajectory. CT analysis of TEC data is used to reconstruct a 2D image of a simulated equatorial plume. TEC data is computed for a linear chain of nine receivers with adjacent spacings of either 100 or 200 km. The simulation data are analyzed to provide an F region reconstruction on a grid with 15 x 15 km pixels. Ionospheric rocket tomography may also be applied to rocket-assisted measurements of amplitude and phase scintillations and airglow intensities.

Bernhardt, P. A.↗

Three-dimensional reconstruction of coronal mass ejections

Computer assisted tomography (CAT) techniques are used to reconstruct the three dimensional shape of coronal mass ejections in the interplanetary medium. Both the Helios 2 spacecraft zodiacal-light photometers and the Solwind coronograph measure changes in Thomson scattering of sunlight from electrons. The technique from near-perpendicular Solwind and Helios views are applied to determine the density of a mass ejection which left the solar surface on 24 May 1979. The coronograph and the Helios perspective views are not simultaneous; the Solwind observations extend outward to sky plane distances of only 10 of the solar radius, whereas the Helios 16 photometer observes to as close as 17 of the solar radius from the sun. The solution is obtained by assuming outward radial expansion and that the coronal mass ejections (CME's) have the same speed everywhere at the same height. The analyses show that CME's are extensive three dimensional structures (the CME of 24 May appears approximately shell) like in three dimensions.

Jackson, Bernard V.↗

Magnetospheric Constellation and Tomography Mission Concept

We describe the basic principles, instrumentation, and feasibility of a multi-satellite mission that combines in situ observations of plasma and electromagnetic fields with radio tomography imaging. We show that a 16-satellite radio tomography experiment can produce two-dimensional images of plasma density in the earth's magnetosphere at sufficient spatial (1/2 R(sub E)) and temporal (approximately 10s) resolution to address key problems of magnetospheric physics. The same mission can incorporate electron and ion analyzers, magnetometers, and electric field instruments on the same spacecraft. We suggest that the large-scale images are more valuable when combined with in situ observations, supporting an unambiguous interpretation of the in situ data and an investigation of the interdependence of small- and large-scale plasma processes.

Ergun, R. E.↗

Microgravity Electrical Capacitance Tomography Data Set

Propellants mass gauging technologies designed to work in an accelerated environment, where the propellant remains settled at one end of the propellant tank, do not work well in a microgravity environment because the propellant is not necessarily settled. While some microgravity mass gauging technologies exist at various TRLs, most of them have major disadvantages. Improvements in microgravity propellant mass gauging will result in improvements to many areas of propellant management, which influences performance and mission assurance. Electrical Capacitance Tomography (ECT) is a sensing technology that has been used in the oil/gas industry for decades to measure multi-phase flow rate in pipes. ECT, when installed in a tank, is able to reconstruct the liquid distribution inside of the tank, which can then be integrated to obtain mass. ECT mass gauging recently achieved high accuracy in laboratory testing on the ground, and while ECT mass gauging will theoretically work during all phases of flight, it had not yet been tested in microgravity. The NASA KSC Launch Services Program, with support from the Flight Opportunities Program, successfully flew an ECT tank liquid mass gauging system experiment on a Zero-G parabolic flight aircraft. The experiment hardware was rented from a company; NASA LSP did no technology development work for this project. This STRIVES entry is for the entire raw data set, which consists of approximately 25GB of csv files of capacitance and motion data from the ground and flight tests of the experiment. The data set will be available on the NASA LSP Electronic Slosh Data Catalog (ESDC), and the public may request the data set from the authors (POC: Jed Storey, jedediah.m.nasa.gov).

mass gauging↗

Atmosphere-Ionosphere Response to the M9 Tohoku Earthquake Revealed by Multi-Instrument Space-Borne and Ground Observations. Preliminary Results

We retrospectively analyzed the temporal and spatial variations of four different physical parameters characterizing the state of the atmosphere and ionosphere several days before the M9 Tohoku Japan earthquake of March 11, 2011. Data include outgoing long wave radiation (OLR), GPS/TEC, Low-Earth orbit ionospheric tomography and critical frequency foF2. Our first results show that on March 8th a rapid increase of emitted infrared radiation was observed from the satellite data and an anomaly developed near the epicenter. The GPS/TEC data indicate an increase and variation in electron density reaching a maximum value on March 8. Starting on this day in the lower ionospheric there was also confirmed an abnormal TEC variation over the epicenter. From March 3-11 a large increase in electron concentration was recorded at all four Japanese ground based ionosondes, which returned to normal after the main earthquake The joined preliminary analysis of atmospheric and ionospheric parameters during the M9 Tohoku Japan earthquake has revealed the presence of related variations of these parameters implying their connection with the earthquake process. This study may lead to a better understanding of the response of the atmosphere/ionosphere to the Great Tohoku earthquake.

Ouzounov, Dimitar↗

The Visible Human Project of the National Library of Medicine: Remote access and distribution of a multi-gigabyte data set

As part of the 1986 Long-Range Plan for the National Library of Medicine (NLM), the Planning Panel on Medical Education wrote that NLM should '...thoroughly and systematically investigate the technical requirements for and feasibility of instituting a biomedical images library.' The panel noted the increasing use of images in clinical practice and biomedical research. An image library would complement NLM's existing bibliographic and factual database services and would ideally be available through the same computer networks as are these current NLM services. Early in 1989, NLM's Board of Regents convened an ad hoc planning panel to explore possible roles for the NLM in the area of electronic image libraries. In its report to the Board of Regents, the NLM Planning Panel on Electronic Image Libraries recommended that 'NLM should undertake a first project building a digital image library of volumetric data representing a complete, normal adult male and female. This Visible Human Project will include digitized photographic images for cryosectioning, digital images derived from computerized tomography, and digital magnetic resonance images of cadavers.' The technologies needed to support digital high resolution image libraries, including rapid development; and that NLM encourage investigator-initiated research into methods for representing and linking spatial and textual information, structural informatics. The first part of the Visible Human Project is the acquisition of cross-sectional CT and MRI digital images and cross-sectional cryosectional photographic images of a representative male and female cadaver at an average of one millimeter intervals. The corresponding cross-sections in each of the three modalities are to be registerable with one another.

Ackerman, Michael J.↗

Dose- and Ion-Dependent Effects in the Oxidative Stress Response to Space-Like Radiation Exposure in the Skeletal System

Exposure to space radiation may pose a risk to skeletal health during subsequent aging. Irradiation acutely stimulates bone remodeling in mice, although the long-term influence of space radiation on bone-forming potential (osteoblastogenesis) and possible adaptive mechanisms are not well understood. We hypothesized exposure to ionizing radiation impairs osteoblastogenesis in an ion-type specific manner, with low doses capable of modulating expression of redox-related genes. 16-week old, male, C57BL6/J mice were exposed to low linear-energy-transfer (LET) protons (150 mega electron volts per nucleon) or high-LET (sup 56) Fe ions (600 mega electron volts per nucleon) using either low (5 or 10 centigrays) or high (50 or 200 centigrays) doses at NASAs Space Radiation Lab at Brookhaven National Lab (NSRL/BNL). Tissues were harvested 5 weeks or 1 year after irradiation and bones were analyzed by microcomputed tomography for cancellous microarchitecture and cortical geometry. Marrow-derived, adherent cells were grown under osteoblastogenic culture conditions. Cell lysates were analyzed for select groups by RT-PCR (Reverse Transcription-Polymerase Chain Reaction) during the proliferative phase or the mineralizing phase, and differentiation was analyzed by imaging mineralized nodules (percentage surface area). Representative genes were selected for expression analyses, including cell proliferation (PCNA, Cdk2, p21, p53), differentiation (Runx2, Alpl, Bglap), oxidative metabolism (Catalase, GPX, MnSOD, CuZnSOD, iNos, Foxo1), DNA-damage repair (Gadd45), or apoptosis (Caspase 3). As expected, a high dose (200 centigrays), but not low doses, of either (sup 56) Fe or protons caused a loss of cancellous bone volume per total volume. Marrow cells produced mineralized nodules ex vivo regardless of radiation type or dose; (sup 56) Fe (200 centigrays) inhibited median nodule area by more than 90 percent at 5 weeks and 1 year post-irradiation, compared to controls. At 5 weeks post exposure, irradiation with protons or (sup 56) Fe caused few changes in gene expression levels during osteoblastogenesis, although a high dose of (sup 56) Fe (200 centigrays) increased levels of Catalase and Gadd45. In addition, supplementing cell culture media with SOD protected marrow-derived osteoprogenitors from the damaging effects of exposure to low-LET ((sup 137) Cs gamma) if irradiated in vitro, but had limited protective effects on high-LET (sup 56) Fe-exposed cells. In sum, exposure of mice to either protons or (sup 56) Fe at a relatively high dose (200 cGy) caused persistent bone loss, whereas only high-LET (sup 56) Fe increased expression of redox-related genes and inhibited osteoblastogenesis, albeit to a limited extent. We conclude that high-LET irradiation impaired osteoblastogenesis and regulated steady-state gene expression of select redox-related genes during osteoblastogenesis, which may contribute to persistent bone loss.

ionizing radiation↗

Experimental and Theoretical Needs for the JWST Early Release Science Program on Radiative Feedback from Massive Stars (PDRs4ALL): III. A Quantum Chemistry Perspective

Massive stars disrupt their natal molecular cloud material by dissociating molecules, ionizing atoms and molecules, and heating the gas and dust. These processes drive the evolution of interstellar matter in our Galaxy and throughout the Universe from the era of vigorous star formation at z=1-3 to the present day. Much of this interaction occurs in Photo- Dissociation Regions (PDRs) where far-ultraviolet photons of these stars create a largely neutral, but warm region of gas and dust. PDR emission dominates the IR spectra of starforming galaxies and provides a unique tool to study the physical and chemical processes that are relevant for inter- and circumstellar media including diffuse clouds, molecular cloud and protoplanetary disk surfaces, and starburst galaxies. The ERS program ID1288 is dedicated to provide template data as well as data processing and analysis tools for PDRs. To this end, it will observe the Orion Bar, the proto-typical PDR situated in the nearby Orion Nebula, using NIRSpec IFU, MIRI IFU, and NIRCAM and MIRI imaging. These observations will, for the first time, spatially resolve and perform a tomography of the PDR, revealing the individual IR spectral signatures from the key zones and sub-regions within the ionized gas, the PDR, and the molecular cloud. Quantum chemistry can be used to determine molecular data such as ionization potentials, chemical reaction rates, electronic spectra, dissociation energies, channels, and branching ratios, etc. These are often used in synergy with experiment to take advantage of the strengths of each approach. An area of active research is modeling the infrared (IR) emission spectra produced by PAH molecules, including the effects of anharmonicity. This will be important in the interpretation of JWST data which will yield higher-resolution spectral data compared to Spitzer or ISO. Quantum chemistry methods can compute accurate anharmonic IR absorption spectra of PAH molecules up to about 25 C atoms, and the results have been benchmarked against high-resolution experimental spectra. These feed into a quantum Monte Carlo (QMC) approach to generate temperature-dependent anharmonic IR emission spectra and then used to generate fully anharmonic cascade emission IR spectra of PAH molecules -- the very type of spectra that JWST will observe. Work continues to extend these methods to larger PAH molecules. We will discuss the current state of this work, as well as

Timothy Lee↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Materials Characterization of Electron Beam Melted Ti-6Al-4V

An in-depth material characterization of Electron Beam Melted (EBM) Ti-6Al-4V material has been completed. Hot Isostatic Pressing (HIP) was utilized to close porosity from fabrication and also served as a material heat treatment to obtain the desired microstructure. The changes in the microstructure and chemistry from the powder to pre-HIP and post-HIP material have been analyzed. Computed tomography (CT) scans indicated porosity closure during HIP and high-density inclusions scattered throughout the specimens. The results of tensile and high cycle fatigue (HCF) testing are compared to conventional Ti-6Al-4V. The EBM Ti-6Al-4V had similar or superior mechanical properties compared to conventionally manufactured Ti-6Al-4V.

Titanium↗

Atmosphere-Ionosphere Response to the M9 Tohoku Earthquake Revealed by Joined Satellite and Ground Observations. Preliminary Results

The recent M9 Tohoku Japan earthquake of March 11, 2011 was the largest recorded earthquake ever to hit this nation. We retrospectively analyzed the temporal and spatial variations of four different physical parameters - outgoing long wave radiation (OLR), GPS/TEC, Low-Earth orbit tomography and critical frequency foF2. These changes characterize the state of the atmosphere and ionosphere several days before the onset of this earthquake. Our first results show that on March 8th a rapid increase of emitted infrared radiation was observed from the satellite data and an anomaly developed near the epicenter. The GPS/TEC data indicate an increase and variation in electron density reaching a maximum value on March 8. Starting on this day in the lower ionospheric there was also confirmed an abnormal TEC variation over the epicenter. From March 3-11 a large increase in electron concentration was recorded at all four Japanese ground based ionosondes, which return to normal after the main earthquake. We found a positive correlation between the atmospheric and ionospheric anomalies and the Tohoku earthquake. This study may lead to a better understanding of the response of the atmosphere/ionosphere to the Great Tohoku earthquake.

Ouzounov, Dimitar↗

Three-Dimensional Optical Coherence Tomography

Three-dimensional (3D) optical coherence tomography (OCT) is an advanced method of noninvasive infrared imaging of tissues in depth. Heretofore, commercial OCT systems for 3D imaging have been designed principally for external ophthalmological examination. As explained below, such systems have been based on a one-dimensional OCT principle, and in the operation of such a system, 3D imaging is accomplished partly by means of a combination of electronic scanning along the optical (Z) axis and mechanical scanning along the two axes (X and Y) orthogonal to the optical axis. In 3D OCT, 3D imaging involves a form of electronic scanning (without mechanical scanning) along all three axes. Consequently, the need for mechanical adjustment is minimal and the mechanism used to position the OCT probe can be correspondingly more compact. A 3D OCT system also includes a probe of improved design and utilizes advanced signal- processing techniques. Improvements in performance over prior OCT systems include finer resolution, greater speed, and greater depth of field.

Gutin, Mikhail↗

A Novel Additive Manufacturing Process Metric for Predicting Spatter-related Porosity in Laser Powder Bed Fusion

Components fabricated using the powder bed fusion laser beam metallic (PBF) additive manufacturing (AM) process comprise a multitude of sequential weld passes. Porosity defects resulting from weld pass inconsistencies are a concern for PBF materials and have a strong adverse effect on the mechanical properties. In an effort to understand and avoid spatter induced porosity, this work aims to provide a novel computational technique that can be used to quantify and predict the sequence-sensitive impact of spatter upon the PBF process stability and consequential porosity in as-printed material. A novel spatter impact AM model-based process metric (AM-PM) is introduced to model and quantify the impact that spatter has on the PBF process. The occurrence of spatter induced porosity is studied using thermal rise, lack of fusion, and spatter impact AM-PMs synchronized with porosity measured by high-resolution X-ray computed tomography. Six cylindrical specimens were designed to compare the AM-PM correlations with porosity across two different laser powers and three hatch scanning strategies. A point field based computational approach is shown to be effective for testing the influence of the different AM-PMs and interrogating the physical process conditions underlying the porosity formation. Further, characterization using optical metallography and scanning electron microscopy indicated that both keyhole and lack of fusion porosity correlated with the spatter impact AM-PM, which can be exploited to predict and control spatter related porosity by the hatch strategy. Efforts to predict porosity composition within PBF material should incorporate the PBF process disturbances that can result from spatter. The spatter impact AM-PM can be readily incorporated into the development of defect prediction models at the part scale.

Additive Manufacturing↗

3d Crystallographic Orientation of Olivine in Bjurböle Chondrules

The crystallographic orientations of chondrule minerals can provide important insights into their formation and deformational history. For example, the orientations of the olivine bars and surrounding rim in barred olivine chondrules provide information and on the conditions of crystallization and the orientations and shapes of olivines within porphritic chondrules can record the reactions with the surrounding nebular gas during chondrule formation. Later deformation on the parent body can cause crystal-plastic deformation of chondrule minerals that is evident through their intracrystalline lattice misorientations. Typically these crystal orientations and lattice misorientations are determined using electron backscatter diffraction (EBSD) on thin sections but this gives only a 2D picture for what is actually a 3D texture. While it is possible to combine EBSD with serial sectioning to build a 3D dataset of texture, this is a destructive, time-intensive process. A recent technological development that enables non-destructive, 3D crystallographic orientation measurement is X-ray diffraction contrast tomography (DCT), which uses the X-ray diffraction of the crystal lattice to determine orientation. Originally only possible using monochromatic X-ray beams at 3rd generation synchrotron light sources, DCT has been recently adapted to polychromatic sources of laboratory X-ray microscopes (referred to as Lab-DCT). Up to this point LabDCT has only been applied to large, well-formed crystals of high symmetry (i.e., metals), but we recently acquired DCT datasets for a pair Bjurböle chondrules to determine the applicability of the technique to natural, mutlimineralic samples composed predominately of olivine (i.e., chondrules).

Hanna, R. D.↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Comparative Validation of Realtime Solar Wind Forecasting Using the UCSD Heliospheric Tomography Model

The University of California, San Diego 3D Heliospheric Tomography Model reconstructs the evolution of heliospheric structures, and can make forecasts of solar wind density and velocity up to 72 hours in the future. The latest model version, installed and running in realtime at the Community Coordinated Modeling Center(CCMC), analyzes scintillations of meter wavelength radio point sources recorded by the Solar-Terrestrial Environment Laboratory(STELab) together with realtime measurements of solar wind speed and density recorded by the Advanced Composition Explorer(ACE) Solar Wind Electron Proton Alpha Monitor(SWEPAM).The solution is reconstructed using tomographic techniques and a simple kinematic wind model. Since installation, the CCMC has been recording the model forecasts and comparing them with ACE measurements, and with forecasts made using other heliospheric models hosted by the CCMC. We report the preliminary results of this validation work and comparison with alternative models.

MacNeice, Peter↗

Phosphate Textural Diversity in CI Chondrites and C-Type Asteroids

Introduction: Apatite, Ca 5 (PO 4 ) 3 (CL/F/OH-), is a ubiquitous phosphate found throughout the solar system, including the most primitive solids, CI-chondrites [1,2] and related samples of carbonaceous asteroids Ryugu [3] and Bennu [4], returned by JAXA’s Hayabusa2 and NASA’s OSIRIS-REx missions, respectively. Apatite in these primitive solids is found as individual grains or mineral clusters and has been inferred to form from the hydrothermal sequence during cooling of their respective parent body or bodies. To better understand the formation history and reworking of these early phosphates we have undertaken a highly coordinated study of phosphate microstructures, geochemistry and U/Pb geochronology from a suite of CI meteorites and carbonaceous asteroid samples. These data have identified novel phosphate microstructures and complex relationships across a suite of apatite grains from the early solar system, indicating multiple episodes of growth and modification on the CI parent body(ies). Methods: Samples of CI chondrites, Alais, Ivuna, Orgueil, Oued Chebeika 002, Yamato (Y) 82162, Y980115, Y980134, and two chips of Hayabusa2 Ryugu particles (A0262 and C0263) have been acquired for analysis. The bulk texture of the samples were first scanned by X-ray Computed Tomography (XCT) using the Nikon XT H 320 within the XFACT facility at NASA JSC or the Xradia 620 Versa at the UTCT facility. Based on the identification of petrofabrics or features of interest from the XCT data, samples were chipped, oriented, potted in epoxy and thick sections were prepared. After anhydrously polishing the samples with silicon carbide and dry diamond powder down to 1 µm, the samples were ion polished using a Hitachi ArBlade. Energy dispersive Xray spectrometry (EDS) maps were collected to ID phosphates of interest using a JEOL 7900F SEM. The internal microstructures of identified phosphates were then mapped by electron backscatter diffraction (EBSD) using the JEOL 7900F. Based on the EDS and EBSD data, domains of interest were targeted for quantitative chemical analyses using a JEOL 8530 EPMA. Subsequently, in situ U-Pb and 207 Pb/ 206 Pb ages will be collected using a Cameca ims1290 secondary ion mass spectrometer at UCLA across a range of microstructures. Results: Apatite grains are ubiquitous throughout the CI chondrites and carbonaceous asteroid materials, found as individual grains, disseminated clusters or grain aggregates. Apatite grains are associated with serpentine, magnet-ite, and/or carbonate. Of particular interest, we have identified individual and aggregate polycrystalline grains ex-hibiting an internal ‘honeycomb’ texture (Fig. 1). Some of these grains appear overprinted by subsequent alteration while others remain unaltered. Apatite halogen sites are dominated by the missing component, assumed to be OH, and F, comparable to published values from Bennu, Ryugu and CM-chondrites [3-5]. However, the Yamato CI-like meteorites show a broader range of Cl values, and one grain from Alais is dominated by CL. Summary: Apatite growth features indicate a protracted and complex growth history, consistent with precipitation from an evolving fluid system. The ‘honeycomb’ texture identified in some CI meteorites is, to the best of our knowledge, the first report of such a microstructure in meteoritic phosphate. The microtextures and zoning will guide subsequent age analyses, to better constrain the formation and reworking of phosphate in CI(-like) materials. Acknowledgments: We thank the National Institute of Polar Research, Japan for samples of Y82162, 980115 and 980134 meteorites, ASU’s Buseck Center for Meteorite Studies for samples of Ivuna and Alais meteorites, and JAXA curation for chips of Ryugu material. This work was funded by NASA ROSES LARS grant 24-LARS24-0014. References: [1] Morlok et al., 2016, GCA 70:5371-5394. [2] Alfin g et al., 2019, Geochemistry 79:125532. [3] Nakamura et al. (2022) Science 379:1-15. [4] Seifert et al. (2026) MAPS 61:504-521. [5] Piralla et al. (2021) MAPS 56:809-828.

CI chondrites↗