Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron streaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Circular Scan Streak Tube Development

A streak tube having circular scan was designed, built and tested. Continuous circular scan, easily derived from out of phase sine waves applied to the conventional deflection plates, permits the timing of pulses traveling long baselines. At the tube's output a circular array of 720 elements is scanned to provide 30 to 40 picosecond resolution. Initial difficulties with electron bombarded silicon arrays were circumvented by using microchannel plates within the streak tube to provide the needed electronic amplification and digital sensitivity and coupling the 720 element arrays to the electron beam by means of a phosphor on a fiber optics. Two ceramic body tubes with S-20 photocathodes were tested and delivered.

Nevin, S.↗

Electron diffraction study of the sillenites Bi{sub 12}SiO{sub 20}, Bi{sub 25}FeO{sub 39} and Bi{sub 25}InO{sub 39}: Evidence of short-range ordering of oxygen-vacancies in the trivalent sillenites

We present an electron diffraction study of three sillenites, Bi{sub 12}SiO{sub 20}, Bi{sub 25}FeO{sub 39}, and Bi{sub 25}InO{sub 39} synthesized using the solid-state method. We explore a hypothesis, inspired by optical studies in the literature, that suggests that trivalent sillenites have additional disorder not present in the tetravalent compounds. Electron diffraction patterns of Bi{sub 25}FeO{sub 39} and Bi{sub 25}InO{sub 39} show streaks that confirm deviations from the ideal sillenite structure. Multi-slice simulations of electron-diffraction patterns are presented for different perturbations to the sillenite structure - partial substitution of the M site by Bi{sup 3+}, random and ordered oxygen-vacancies, and a frozen-phonon model. Although comparison of experimental data to simulations cannot be conclusive, we consider the streaks as evidence of short-range ordered oxygen-vacancies.

36 MATERIALS SCIENCE↗

Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double-shot MeV electron diffraction and microscopy

Here in this paper, we study by numerical simulations a time-resolved MeV electron scattering mode where two consecutive electron pulses are used to capture the evolution of a material sample on 10 ps time scales. The two electron pulses are generated by illuminating a photocathode in a radiofrequency photogun by two short laser pulses with adjustable delay. A streak camera/deflecting cavity is used after the sample to project the two electron bunches on two well separated regions of the detector screen. By using sufficiently short pulses, the 2D spatial information from each snapshot can be preserved. This “double-shot” technique enables the efficient capture of irreversible dynamics in both diffraction and imaging modes. Finally, in this work, we demonstrate both modes in start-to-end simulations of the UCLA Pegasus MeV microscope column.

36 MATERIALS SCIENCE↗

Time-resolved and multiple-angle Thomson scattering on gas-puff Z-Pinch plasmas at pinch time

A 526.5 nm Thomson scattering diagnostic laser enables probing of the plasma conditions of neon gas-puff z-pinch implosions with temporal resolution. Splitting the laser into two 2.5 J pulses, both 2.3 ns in duration and separated by 4 ns, allows observation of sub-nanosecond time-resolved spectra for a total time of 7 ns. Collection optics were set at 90° and 30° to the laser, observing the same on-axis scattering volume with a radial extent of 0.4 mm. The spectra from both angles were collected by using the same streak camera, using a coupling system that allowed us to obtain temporal, spectral, and angular resolution in the same image. By comparing the ion-acoustic spectra from the two angles, we determined electron temperature and a range of possible electron densities. Measurements made in the 1-3 ns period before pinch time show best fit (determined by a least-squares method) electron densities of around 2 × 10 19 cm -3 , increasing to 1.5 × 10 20 cm -3 in the 3 ns following the start of the x-ray burst (t = 0 ns) from the pinch. The electron temperature increases from 300 eV to 500 eV at t = 0 ns before decreasing to below 300 eV after pinch time. With the present parameters (probe beam, collection angles, and electron temperature and density), this diagnostic method is too insensitive to electron density to provide more than a constraint on that parameter. Plasma regimes in which this technique could determine electron density with some precision are calculated.

47 OTHER INSTRUMENTATION↗

Time-Resolved Thomson Scattering on Gas-Puff Z-Pinch Plasmas at Pinch Time

The conditions and dynamics of neon gas puff Z-pinch plasmas at pinch time are studied on a pulsed power generator with a current rise time of approximately 200-ns and 0.9-mA peak current. Radial tailoring of the gas puff massdensity profile using a triple-nozzle coaxial valve (two annular gas liners and a central jet) allows production of both more stable and less stable (with regard to the magneto-Rayleigh– Taylor instability) Z-pinch implosions. A 526.5-nm, 10-J Thomson scattering diagnostic laser enables probing of the flow dynamics and plasma conditions of these implosions with both spatial and temporal resolutions. The 2.2-ns laser pulse scatters from the plasma electrons and is carried by one optical fiber to a visible light streak camera, and by a bundle of optical fibers to a time-gated camera, both after spectral dispersion by 750-mm spectrometers. The streak camera, with a 10-ns full streak time, provides subnanosecond resolution of the evolution of the pinch plasma parameters through stagnation. The timegated camera provides spatially resolved spectra (across a field of view of 6.1 mm) at the same time as the streak. Scattering spectra suggest that temperatures are high at stagnation, with the ion temperature as much as three times higher than the electron temperature. Furthermore, we consider the possibility of nonthermal explanations for the broad scattering spectra and high effective ion temperature, including collisionality, implosion velocity distributions (velocity gradients), and small-scale hydrodynamic motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosing laser-preheated magnetized plasmas relevant to magnetized liner inertial fusion

In this paper, we present a platform on the OMEGA EP Laser Facility that creates and diagnoses the conditions present during the preheat stage of the MAGnetized Liner Inertial Fusion (MagLIF) concept. Experiments were conducted using 9 kJ of 3ω (355 nm) light to heat an underdense deuterium gas (electron density: 2.5 × 10 20 cm -3 = 0.025 of critical density) magnetized with a 10 T axial field. Results show that the deuterium plasma reached a peak electron temperature of 670 ± 140 eV, diagnosed using streaked spectroscopy of an argon dopant. The results demonstrate that plasmas relevant to the preheat stage of MagLIF can be produced at multiple laser facilities, thereby enabling more rapid progress in understanding magnetized preheat. Results are compared with magneto-radiation-hydrodynamics simulations, and plans for future experiments are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-retrieval algorithm for the characterization of broadband single attosecond pulses

Recent progress in high-order harmonic generation with few-cycle mid-infrared wavelength lasers has pushed light pulses into the water-window region and beyond. These pulses have the bandwidth to support single attosecond pulses down to a few tens of attoseconds. However, the present available techniques for attosecond pulse measurement are not applicable to such pulses. Here we report a phase-retrieval method using the standard photoelectron streaking technique where an attosecond pulse is converted into its electron replica through photoionization of atoms in the presence of a time-delayed infrared laser. The iterative algorithm allows accurate reconstruction of the spectral phase of light pulses, from the extreme-ultraviolet (XUV) to soft x-rays, with pulse durations from hundreds down to a few tens of attoseconds. At the same time, the streaking laser fields, including short pulses that span a few octaves, can also be accurately retrieved. Furthermore, such well-characterized single attosecond pulses in the XUV to the soft-x-ray region are required for time-resolved probing of inner-shell electronic dynamics of matter at their own timescale of a few tens of attoseconds.

74 ATOMIC AND MOLECULAR PHYSICS↗

Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator

A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps ({approx}0.24 mm) and 1.5 ps ({approx}0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera. The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.

43 PARTICLE ACCELERATORS↗

SEM, Chemical Etching and THz Wave Generation of 4-Dimethylamino-N-methyl-4-stilbazolium Tosylate (DAST) Single Crystals

The 4-dimethylamino-N-methyl-4-stilbazolium tosylate (DAST) crystal which was candidate for generating and detecting terahertz (THz) wave was grown by slope nucleation method (SNM). The functional groups of DAST were identified by Fourier Transform Infrared (FTIR) studies. Macroscopic steps and streaks on the (001) face were found by scanning electron microscope (SEM). Different patterns of etch pits under different chemical etchants were studied by optical microscope. Widely tunable THz waves ranging from 0.38 to 18.10 THz were generated from 0.5 mm-thick DAST crystal. The maximum output energy was 345.4 nJ/pulse at 3.39 THz and the conversion efficiency was 8.44 × 10{sup –5}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recording the synchrotron radiation by a picosecond streak camera for bunch diagnostics in cyclic accelerators

A PS-1/S1 picosecond streak camera with a linear sweep is used to measure temporal characteristics of synchrotron radiation pulses on a damping ring (DR) at the Budker Institute of Nuclear Physics (BINP) of the Siberian Branch of the Russian Academy of Sciences (Novosibirsk). The data obtained allow a conclusion as to the formation processes of electron bunches and their 'quality' in the DR after injection from the linear accelerator. The expediency of employing the streak camera as a part of an optical diagnostic accelerator complex for adjusting the injection from a linear accelerator is shown. Discussed is the issue of designing a new-generation dissector with a time resolution up to a few picoseconds, which would allow implementation of a continuous bunch monitoring in the DR during mutual work with the electron-positron colliders at the BINP. (acoustooptics)

43 PARTICLE ACCELERATORS↗

Longitudinal bunch shaping of picosecond high-charge MeV electron beams

With ever increasing demands for intensities in modern accelerators, the understanding of space-charge effects becomes crucial. Herein are presented measurements of optically shaped picosecond-long electron beams in a superconducting L-band linac over a wide range of charges, from 0.2 nC to 3.4 nC. At low charges, the shape of the electron beam is preserved, while at higher charge densities, modulations on the beam convert to energy modulations. Here, energy profile measurements using a spectrometer and time profile measurements using a streak camera reveal the dynamics of longitudinal space-charge on MeV-scale electron beams.

43 PARTICLE ACCELERATORS↗

Solid state streak camera prototype performance testing and future upgrades

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolving diagnostics for studying events that occur on the nanosecond to microsecond time scales. The Nevada National Security Site (NNSS) and Sandia National Laboratories (SNL) have built a 42-channel solid state streak camera (SSSC) prototype as a proof of concept for use as a streak camera replacement. This work is part of an ongoing project to develop the technology to a level competitive with analog streak cameras. This manuscript discusses the device concept, results from electronic and laser testing, and recent improvements to increase the device’s dynamic range.

Plasma diagnostics - interferometry, spectroscopy ↗

Solid state imagers and their applications; Proceedings of the Meeting, Cannes, France, November 26, 27, 1985

Topics treated include the use of semiconductor imagers in high energy particle physics, an X-ray image sensor based on an optical TDI-CCD imager, and an electron-sensitive CCD readout array for a circular-scan streak tube. Papers are presented on the pan-imager, high resolution linear arrays, the reduction of reflection losses in solid-state image sensors, a high resolution CCD imager module with swing operation, large area CCD image sensors for scientific applications, and new readout techniques for frame transfer CCDs. Consideration is given to advanced optoelectronical sensors for autonomous rendezvous/docking and proximity operations in space, the testing and characterization of CCDs for the Rosat star sensors, an advanced radial camera for the Hubble Space Telescope, and scanning or staring infrared imagers.

Declerck, Gilbert J.↗

Narrow bandgap semiconducting silicides: Intrinsic infrared detectors on a silicon chip

Work done during the final report period is presented. The main technical objective was to achieve epitaxial growth on silicon of two semiconducting silicides, ReSi2 and CrSi2. ReSi2 thin films were grown on (001) silicon wafers by vacuum evaporation of rhenium onto hot substrates in ultrahigh vacuum. The preferred epitaxial relationship was found to be ReSi2(100)/Si(001) with ReSi2(010) parallel to Si(110). The lattice matching consists of a common unit mesh of 120 A(sup 2) area, and a mismatch of 1.8 percent. Transmission electron microscopy revealed the existence of rotation twins corresponding to two distinct but equivalent azimuthal orientations of the common unit mesh. MeV He(+) backscattering spectrometry revealed a minimum channeling yield of 2 percent for an approximately 1,500 A thick film grown at 650 C. Although the lateral dimension of the twins is on the order of 100 A, there is a very high degree of alignment between the ReSi2(100) and the Si(001) planes. Highly oriented films of CrSi2 were grown on (111) silicon substrates, with the matching crystallographic faces being CrSi2(001)/Si(111). The reflection high-energy electron diffraction (RHEED) patterns of the films consist of sharp streaks, symmetrically arranged. The predominant azimuthal orientation of the films was determined to be CrSi2(210) parallel to Si(110). This highly desirable heteroepitaxial relationship has been obtained previously by others; it may be described with a common unit mesh of 51 A(sup 2) and mismatch of 0.3 percent. RHEED also revealed the presence of limited film regions of a competing azimuthal orientation, CrSi2(110) parallel to Si(110). A channeling effect for MeV He(+) ions was not found for this material. Potential commercial applications of this research may be found in silicon-integrated infrared detector arrays. Optical characterizations showed that semiconducting ReSi2 is a strong absorber of infrared radiation, with the adsorption constant increasing above 2 x 10(exp 4) cm(sup -1) for photon energies above 0.2 eV. CrSi2 is of potential utility for detection at photon energies above approximately 0.3 eV.

Mahan, John E.↗

Proposed Longitudinal Profile Diagnostics for Optical Stochastic Cooling of Stored Electrons in the IOTA Ring

One of the predicted signatures of successful optical stochastic cooling (OSC) in the Fermilab Integrable Optics Test Accelerator (IOTA) ring is reduction of the bunch length. The IOTA OSC experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps*. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam. A similar measurement was previously performed at the Advanced Photon Source with a Hamamatsu C5680 synchroscan streak camera operating at 117.3 MHz**. In this case, synchronous summing of OSR resulted in a bunch length measurement of 276 ± 30 ps using only 57 electrons circulating at 425 MeV. At IOTA, an existing streak camera has been modified to operate at the 11th harmonic of the ring’s revolution frequency of 7.50 MHz and has been installed on an OSR port in support of the OSC experiments. The integrated system will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.

Lumpkin, Alex H.↗