Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron guns”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Studies of beam plasma interactions in a space simulation chamber using prototype Space Shuttle instruments

In March, 1981, electron beam experiments were conducted in a large space simulation chamber using equipment destined to be flown aboard NASA's Office of Space Science-1 pallet (OSS-1). Two major flight experiments were involved. They include the Vehicle Charging and Potential (VCAP) experiment and the Plasma Diagnostics Package (PDP). Apparatus connected with VCAP included a Fast Pulse Electron Gun (FPEG), and a Charge and Current Probe (CCP). A preliminary view is provided of the results obtained when the electron emissions were held steady over relatively long periods of time such that steady state conditions could be obtained with respect to the electron beam interaction with the neutral gases and plasma of the vacuum chamber. Of particular interest was the plasma instability feature known as the Beam Plasma Discharge. For the present experiments the FPEG was used in a dc mode with a range of currents of 2 to 80 mA at a beam energy of 970 eV. Attention is given to the emissions of VLF and HF noise associated with the dc beam.

Banks, P. M.↗

Traveling wave tube and method of manufacture

A traveling wave tube includes a glass or other insulating envelope having a plurality of substantially parallel glass rods supported therewithin which in turn support an electron gun, a collector and an intermediate slow wave structure. The slow wave structure itself provides electrostatic focussing of a central electron beam thereby eliminating the need for focussing magnetics and materially decreasing the cost of construction as well as enabling miniaturization. The slow wave structure advantageously includes cavities along the electron beam through which the r.f. energy is propagated, or a double, interleaved ring loop structure supported by dielectric fins within a ground plane cylinder disposed coaxially within the glass envelope.

Vancil, Bernard K.↗

Long life electrodes for large-area x-ray generators

This invention is directed to rugged, reliable, and long-life electrodes for use in large-area, high-current-density electron gun and x-ray generators which are employed as contamination-free preionizers for high-energy pulsed gas lasers. The electron source at the cathode is a corona plasma formed at the interface between a conductor, or semiconductor, and a high-permittivity dielectric. Detailed descriptions are provided of a reliable cold plasma cathode, as well as an efficient liquid-cooled electron beam target (anode) and x-ray generator which concentrates the x-ray flux in the direction of an x-ray window.

Rothe, Dietmar E.↗

Effect of electron beam pulse width on time-of-flight spectra

A simple but useful formula describing the effect of electron gun pulse width on the time of flight (TOF) spectra measured in translational spectroscopy experiments is developed. An approximately monoenergetic pulsed electrostatically focused electron beam traverses a scattering cell filled with a Maxwellian gas. Inelastic electron collisions with the gas produce metastable particles, ions, scattered electrons, and photons which then pass through a collimating slit system at right angles to the electron beam. TOF techniques are used to separate the photon signal from the metastable particle signal and to measure the TOF distribution of the metastable species.

Misakian, M.↗

Programmable Multiple-Ramped-Voltage Power Supply

Ramp waveforms range up to 2,000 V. Laboratory high-voltage power-supply system puts out variety of stable voltages programmed to remain fixed with respect to ground or float with respect to ramp waveform. Measures voltages it produces with high resolution; automatically calibrates, zeroes, and configures itself; and produces variety of input/output signals for use with other instruments. Developed for use with ultraviolet spectrometer. Also applicable to control of electron guns in general and to operation of such diverse equipment used in measuring scattering cross sections of subatomic particles and in industrial electron-beam welders.

Ajello, Joseph M.↗

Active Experiments in Space Plasmas; Symposium D4.1 of Commission D, COSPAR Scientific Assembly, 30th, Hamburg, Germany, July 11-21, 1994

Papers from the conference are presented and cover the following topics: ion and electron beams; ionospheric modification; spacecraft interactions; chemical releases; and plasma waves. Auroras and plasma emissions are reported from electron beam injection experiments on the EXCEDE 3 rocket and APEX satellite respectively. The important parameters affecting the charging of spacecraft during the operation of electron guns is covered. The Active Magnetospheric Particle Acceleration Satellite (AMPAS) mission utilizing dual-payload tethered satellites and both up and downward directed electron beams is proposed to study the magnetosphere. Recent results and associated theories from the Sura, Arecibo and Troms ionospheric heating facitlites are presented. The effects of neutral gases on spacecraft charging are examined in a series of rocket flights. Many results from the Combined Release and Radiation Effects Satellite chemical release experiments are presented.

Rietveld, M. T.↗

Induced charging of shuttle orbiter by high electron-beam currents

Emission of high-current electron beams that was proposed for some Spacelab payloads required substantial return currents to the orbiter skin in order to neutralize the beam charge. Since the outer skin of the vehicle was covered with approximately 1200 sq m of thermal insulation which has the dielectric quality of air and an electrical conductivity that was estimated by NASA at 10 to the -9 power to 10 to the -10 power mhos/m, considerable transient charging and local potential differences were anticipated across the insulation. The theory for induced charging of spacecraft due to operation of electron guns was only developed for spherical metal vehicles and constant emission currents, which were not directly applicable to the orbiter situation. Field-aligned collection of electron return current from the ambient ionosphere at orbiter altitudes provides up to approximately 150 mA on the conducting surfaces and approximately 2.4 A on the dielectric thermal insulation. Local ionization of the neutral atmosphere by energetic electron bombardment or electrical breakdown may provide somewhat more return current.

Liemohn, H. B.↗

Photoelectron spectrometer with means for stabilizing sample surface potential

An improved X-ray photoelectron spectrometer is disclosed, which includes circuit means to determine the surface potential of a sample, e.g., an insulator. The circuit means comprise an electron gun, whose potential is modulated at a preselected frequency above and below a selected potential with respect to the spectrometer common potential, e.g., ground. The beam of electrons is directed to the sample surface. The sample's surface potential is offset by an offset power supply with respect to the spectrometer common potential until the ac current which flows through the sample reaches a peak amplitude. A lock-in amplifier is included to measure the ac current in phase with the modulating frequency.

Grunthaner, F. J.↗

Electron beam irradiation of thinned backside illuminated CCDs

The physical properties of backside illuminated surface channel CCD arrays and a pixel buried channel CCD array when bombarded with electrons were studied. The devices were mounted in a high vacuum system and irradiated with electrons generated by an electron gun. Basic measurements of EBS gain, dead voltage, transfer efficiency and dark current were performed to verify proper device operation. The surface channel devices were then irradiated with electrons of up to 8 keV energy for up to 98 hours while the buried channel device was irradiated with electrons.

Borsuk, G. M.↗

VLF wave stimulation by pulsed electron beams injected from the Space Shuttle

Among the investigations conducted on the Space Shuttle flight STS-3 of March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the Shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the wave exhibited various spectral harmonics as well as the unexpected occurrence of 'satellite lines' around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.

Reeves, G. D.↗

Dissociative excitation of vacuum ultraviolet emission features by electron impact on molecular gases. 3: CO2

Vacuum ultraviolet multiplets of C I, C II, and O I were produced by electron impact on CO2. Absolute emission cross sections for these multiplets were measured from threshold to 350 eV. The electrostatically focused electron gun used is described in detail. The atomic multiplets which were produced by dissociative excitation of CO2 and the cross sections at 100 eV are presented. The dependence of the excitation functions on electron energy shows that these multiplets are produced by electric-dipole-allowed transitions in CO2.

Mumma, M. J.↗

Dissociative excitation of vacuum ultraviolet emission features by electron impact on molecular gases. 3: CO2

Vacuum ultraviolet multiplets of C I, C II, and O I were produced by electron impact of CO2. Absolute emission cross sections for these multiplets were measured from threshold to 350 eV. The electrostatically focussed electron gun used in this series of experiments is described in detail. The atomic multiplets which were produced by dissociative excitation of CO2 and the cross sections at 100 eV are given. The dependence of the excitation functions on electron energy shows that these multiplets are produced by electric-dipole-allowed transitions in CO2.

Mumma, M. J.↗

Measurements on wave propagation characteristics of spiraling electron beams

Dispersion characteristics of cyclotron-harmonic waves propagating on a neutralized spiraling electron beam immersed in a uniform axial magnetic field are studied experimentally. The experimental setup consisted of a vacuum system, an electron-gun corkscrew assembly which produces a 110-eV beam with the desired delta-function velocity distribution, a measurement region where a microwave signal is injected onto the beam to measure wavelengths, and a velocity analyzer for measuring the axial electron velocity. Results of wavelength measurements made at beam currents of 0.15, 1.0, and 2.0 mA are compared with calculated values, and undesirable effects produced by increasing the beam current are discussed. It is concluded that a suitable electron beam for studies of cyclotron-harmonic waves can be generated by the corkscrew device.

Singh, A.↗

A Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) for the Surface of Mars: An Instrument for the Planetary Science Community

The Miniaturized Variable Pressure Scanning Electron Microscope(MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Science (ROSES), will build upon previous miniaturized SEM designs for lunar and International Space Station (ISS) applications and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. By the end of the PICASSO work, a prototype of the primary proof-of-concept components (i.e., the electron gun, focusing optics and scanning system)will be assembled and preliminary testing in a Mars analog chamber at the Jet Propulsion Laboratory will be completed to partially fulfill Technology Readiness Level to 5 requirements for those components. The team plans to have Secondary Electron Imaging(SEI), Backscattered Electron (BSE) detection, and Energy Dispersive Spectroscopy (EDS) capabilities through the MVP-SEM.

Mars↗

Isotopic Enrichment of Boron in the Sputtering of Boron Nitride with Xenon Ions

An experimental study is described to measure the isotopic enrichment of boron. Xenon ions from 100 eV to 1.5 keV were used to sputter a boron nitride target. An ion gun was used to generate the ion beam. The ion current density at the target surface was approximately 30 microA/sq cm. Xenon ions impinged on the target surface at 50 deg angle to the surface normal. Since boron nitride is an insulator, a flood electron gun was used in our experiments to neutralize the positive charge buildup on the target surface. The sputtered secondary ions of boron were detected by a quadrupole mass spectrometer. The spectrometer entrance aperture was located perpendicular to the ion beam direction and 10 mm away from the target surface. The secondary ion flux was observed to be enriched in the heavy isotopes at lower ion energies. The proportion of heavy isotopes in the sputtered secondary ion flux was found to decrease with increasing primary ion energy from 100 to 350 eV. Beyond 350 eV, light isotopes were sputtered preferentially. The light isotope enrichment factor was observed to reach an asymptotic value of 1.27 at 1.5 keV. This trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.

Ray, P. K.↗

Charging and discharging characteristics of dielectric materials exposed to low- and mid-energy electrons

Charging and discharging characteristics of dielectric samples exposed to 1-25 keV and 25-100 keV electrons in a laboratory environment are reported. The materials examined comprised OSR, Mylar, Kapton, perforated Kapton, and Alphaquartz, serving as models for materials employed on spacecraft in geosynchronous orbit. The tests were performed in a vacuum chamber with electron guns whose beams were rastered over the entire surface of the planar samples. The specimens were examined in low-impedance-grounded, high-impedance-grounded, and isolated configurations. The worst-case and average peak discharge currents were observed to be independent of the incident electron energy, the time-dependent changes in the worst case discharge peak current were independent of the energy, and predischarge surface potentials are negligibly dependent on incident monoenergetic electrons.

Coakley, P.↗

Vehicle charging and potential on the STS-3 mission

An electron gun with fast pulse capability was used in the vehicle charging and potential experiment carried on the OSS-1 pallet to study dielectric charging, return current mechanisms, and the techniques required to manage the electrical charging of the orbiter. Return currents and charging of the dielectrics were measured during electron beam emission and plasma characteristics in the payload bay were determined in the absence of electron beam emission. The fast pulse electron generator, charge current probes, spherical retarding potential analyzer, and the digital control interface unit which comprise the experiment are described. Results show that the thrusters produce disturbances which are variable in character and magnitude. Strong ram/wake effects were seen in the ion densities in the bay. Vehicle potentials are variable with respect to the plasma and depend upon location on the vehicle relative to the main engine nozzles, the vehicle attitude, and the direction of the geomagnetic field.

Williamson, R.↗

Ion resonances and ELF wave production by an electron beam injected into the ionosphere - ECHO 6

Two effects observed with electron antennas ejected from a sounding rocket launched into the ionosphere in March 1983 carrying electron beam guns are discussed. The sensor packages were ejected and travelled parallel to the vehicle trajectory. Electric potentials were measured between the single probes and a plasma diagnostic package while the gun injected electrons into the ionosphere in perpendicular and parallel 1 kHz directions. Signal pulses over the dc-1250 kHz range were detected. A kHz gun frequency caused a signal that decreased by two orders of magnitude between 45-90 m from the beam field line. However, the signal was detectable at 1 mV/m at 120 m, supporting earlier data that indicated that pulsed electron beams can cause ELF waves in space. Beam injection parallel to the magnetic field produced an 840 Hz resonance that could be quenched by activation of a transverse beam.

Winckler, J. R.↗