Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship

Purpose: The conversion of the computed tomography (CT) number to electron density is one of the main processes that determine the accuracy of patient dose calculations in radiotherapy treatment planning. However, the CT number and electron density of tissues cannot be generally interrelated via a simple one-to-one correspondence because the CT number depends on the effective atomic number as well as the electron density. The purpose of this study is to present a simple conversion from the energy-subtracted CT number ({Delta}HU) by means of dual-energy CT (DECT) to the relative electron density ({rho}{sub e}) via a single linear relationship. Methods: The {Delta}HU-{rho}{sub e} conversion method was demonstrated by performing analytical DECT image simulations that were intended to imitate a second-generation dual-source CT (DSCT) scanner with an additional tin filtration for the high-kV tube. The {Delta}HU-{rho}{sub e} calibration line was obtained from the image simulation with a 33 cm-diameter electron density calibration phantom equipped with 16 inserts including polytetrafluoroethylene, polyvinyl chloride, and aluminum; the elemental compositions of these three inserts were quite different to those of body tissues. The {Delta}HU-{rho}{sub e} conversion method was also applied to previously published experimental CT data, which were measured using two different CT scanners, to validate the clinical feasibility of the present approach. In addition, the effect of object size on {rho}{sub e}-calibrated images was investigated by image simulations using a 25 cm-diameter virtual phantom for two different filtrations: with and without the tin filter for the high-kV tube. Results: The simulated {Delta}HU-{rho}{sub e} plot exhibited a predictable linear relationship over a wide range of {rho}{sub e} from 0.00 (air) to 2.35 (aluminum). Resultant values of the coefficient of determination, slope, and intercept of the linear function fitted to the data were close to those of the ideal case. The maximum difference between the ideal and simulated {rho}{sub e} values was -0.7%. The satisfactory linearity of {Delta}HU-{rho}{sub e} was also confirmed from analyses of the experimental CT data. In the experimental cases, the maximum difference between the nominal and simulated {rho}{sub e} values was found to be 2.5% after two outliers were excluded. When compared with the case without the tin filter, the {Delta}HU-{rho}{sub e} conversion performed with the tin filter yielded a lower dose and more reliable {rho}{sub e} values that were less affected by the object-size variation. Conclusions: The {Delta}HU-{rho}{sub e} calibration line with a simple one-to-one correspondence would facilitate the construction of a well-calibrated {rho}{sub e} image from acquired dual-kV images, and currently, second generation DSCT may be a feasible modality for the clinical use of the {Delta}HU-{rho}{sub e} conversion method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Curling probe measurement of electron density in pulse-modulated plasma

The electron density n{sub e} of stationary plasma can be easily obtained on the basis of the resonance frequency f of a curling probe (CP) measured by a network analyzer (NWA). However, in pulsed plasma with discharge period T, the n{sub e} and f values periodically change with time. This study extends the conventional CP technique to a time-resolved measurement of the pulse-modulated electron density. The condition necessary for the measurement is revealed to be synchronization of NWA with the pulse modulation, which is expressed as (n − 1)T/T{sub SWP} = integer (1, 2, …) for a number n of data point and sweep time T{sub SWP}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron density measurement of inductively coupled plasmas by terahertz time-domain spectroscopy (THz-TDS)

The electron densities of argon inductively coupled plasmas were measured by terahertz time-domain spectroscopy (THz-TDS). At a low pressure, the electron densities were also measured with a Langmuir-type double probe and the validity of THz-TDS electron-density measurement in a plasma has been corroborated. As the input radio-frequency (RF) power increases, the plasma density and gas temperature increase, which makes the probe measurement less reliable or even impossible, due to the large heat load to the probe surface. On the contrary, the THz-TDS measurement is unaffected by the gas temperature and becomes more reliable due to the higher electron density at higher input power for plasma generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional mapping of electron densities and temperatures using laser-collision induced fluorescence.

We discuss the application of the laser-collision induced fluorescence technique to produce two-dimensional maps of both electron densities and electron temperatures in a helium plasma. A collisional-radiative model is used to describe the evolution of electronic states after laser excitation. We discuss generalizations to the time dependant results that are used to simplify data acquisition and analysis. Calibration of the predictions made by the model is achieved using an cw rf discharge that is periodically perturbed via a high voltage pulse. We then demonstrate the capability of the technique by producing images of electron density and temperature of the sheath region formed around a biased electrode.

99 GENERAL AND MISCELLANEOUS↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

Interpretation of very low resolution X-ray electron-density maps using core objects

The interpretation of a 20 Å resolution electron-density map using segmentation and pattern-recognition-based identification of domain shapes is described. A novel approach to obtaining structural information from macromolecular X-ray data extending to resolutions as low as 20 Å is presented. Following a simple map-segmentation procedure, the approximate shapes of the domains forming the structure are identified. A pattern-recognition comparative analysis of these shapes and those derived from the structures of domains from the PDB results in candidate structural models that can be used for a fit into the density map. It is shown that the placed candidate models can be employed for subsequent phase extension to higher resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale mapping of the electron density at Al grain boundaries and correlation with grain-boundary energy

Grain-boundary (GB) structures and energies are often calculated and have revealed correlations between the GB energy and change in electron density at the GB. In this work, the plasmon peak in valence electron energy-loss spectroscopy (VEELS) was used to determine the variation in electron density across four well-characterized GBs in Al, spanning a range of known GB energies. The results show that the plasmon energy is lower at the GB than in the adjacent grains due to a decrease in electron density, and the GB energy increases proportional to the density decrease. The decrease in electron density also extends further into adjacent grains with increasing GB energy, extending beyond the geometric changes, or physical width, revealed by electron microscopy. Plasmon damping also increases with increasing GB energy, indicative of increasing disruption of the electron density with increasing GB energy. These results demonstrate that VEELS can be a valuable tool for detecting small electron density changes at GBs, and this change clearly influences, and is correlated to, the GB energy.

36 MATERIALS SCIENCE↗

Compact and high-particle-flux thermal-lithium-beam probe system for measurement of two-dimensional electron density profile

A compact and high-particle-flux thermal-lithium-beam source for two-dimensional measurement of electron density profiles has been developed. The thermal-lithium-beam oven is heated by a carbon heater. In this system, the maximum particle flux of the thermal lithium beam was ∼4 × 10{sup 19} m{sup −2} s{sup −1} when the temperature of the thermal-lithium-beam oven was 900 K. The electron density profile was evaluated in the small tokamak device HYBTOK-II. The electron density profile was reconstructed using the thermal-lithium-beam probe data and this profile was consistent with the electron density profile measured with a Langmuir electrostatic probe. We confirm that the developed thermal-lithium-beam probe can be used to measure the two-dimensional electron density profile with high time and spatial resolutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of Electron Density near Plasma Grid of Large-scaled Negative Ion Source by Means of Millimeter-Wave Interferometer

A millimeter-wave interferometer with the frequency of 39 GHz ({lambda} 7.7 mm) was newly installed to a large-scaled negative ion source. The measurable line-integrated electron density (n{sub e}l) is from 2x10{sup 16} to 7x10{sup 18} m{sup -2}, where n{sub e} and l represent an electron density and the plasma length along the millimeter-wave path, respectively. Our interest in this study is behavior of negative ions and reduction of electron density in the beam extraction region near the plasma grid. The first results show the possibility of the electron density measurement by the millimeter-wave interferometer in this region. The line-averaged electron density increases proportional to the arc power under the condition without cesium seeding. The significant decrease of the electron density and significant increase of the negative ion density were observed just after the cesium seeding. The electron density measured with the interferometer agrees well with that observed with a Langmuir probe. The very high negative ion ratio of n{sub H-}/(n{sub e}+n{sub H-}) = 0.85 was achieved within 400 min. after the cesium seeding.

43 PARTICLE ACCELERATORS↗

The effects of radio-frequency bias on electron density in an inductively coupled plasma reactor

The effect of radio-frequency bias on electron density in an inductively coupled plasma reactor was measured using a wave cutoff probe, over a wide range of conditions in pure Ar, pure CF{sub 4}, and 50%-50% mixtures of Ar/CF{sub 4}, at pressures of 0.7-4.0 Pa (5-30 mTorr), bias frequencies of 10-30 MHz, bias voltages up to 750 V, and inductive source powers of 50-300 W. Also, at selected experimental conditions, comparisons with Langmuir probe measurements were made. Two types of bias-induced changes in electron density were detected. First, at high source powers, we observed a bias-induced decrease in electron density, which had a slow time response (several minutes), a linear dependence on bias voltage, and little or no dependence on bias frequency or pressure. This decrease is a gas composition effect caused by etch or sputter products liberated from the wafer surface. Second, at low source powers, we observed a faster, bias-induced increase in electron density, which was proportional to the bias frequency and the square root of the bias voltage. This second effect was caused by absorption of bias power by electrons via stochastic heating. Simple models of each effect were derived and were shown to yield quantitative predictions in agreement with the observations. To obtain correct predictions, the effect of bias-induced electron heating cannot be considered by itself; rather, its effect on the efficiency of the inductive source must also be considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density and temperature of gas-temperature-dependent cryoplasma jet

A microsize cryoplasma jet was developed and analyzed at plasma gas temperatures ranging from room temperature down to 5 K. Experimental results obtained from optical emission spectroscopy and current-voltage measurements indicate that the average electron density and electron temperature of the cryoplasma jet depend on the gas temperature. In particular, the electron temperature in the cryoplasma starts to decrease rapidly near 60 K from about 13 eV at 60 K to 2 eV at 5 K, while the electron density increases from about 10{sup 9} to approximately 10{sup 12} cm{sup -3} from room temperature to 5 K. This phenomenon induces an increase in the Coulomb interaction between electrons, which can be explained by the virial equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical quality indicators for electron-density maps

A likelihood-based metric for scoring the local agreement of a structure model with the observed electron density is described. The commonly used validation metrics for the local agreement of a structure model with the observed electron density, namely the real-space R (RSR) and the real-space correlation coefficient (RSCC), are reviewed. It is argued that the primary goal of all validation techniques is to verify the accuracy of the model, since precision is an inherent property of the crystal and the data. It is demonstrated that the principal weakness of both of the above metrics is their inability to distinguish the accuracy of the model from its precision. Furthermore, neither of these metrics in their usual implementation indicate the statistical significance of the result. The statistical properties of electron-density maps are reviewed and an improved alternative likelihood-based metric is suggested. This leads naturally to a χ{sup 2} significance test of the difference density using the real-space difference density Z score (RSZD). This is a metric purely of the local model accuracy, as required for effective model validation and structure optimization by practising crystallographers prior to submission of a structure model to the PDB. A new real-space observed density Z score (RSZO) is also proposed; this is a metric purely of the model precision, as a substitute for other precision metrics such as the B factor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging

Many scientific research areas rely on accurate electron density characterization of various materials. For instance in X-ray optics and radiation therapy, there is a need for a fast and reliable technique to quantitatively characterize samples for electron density. We present how a precise measurement of electron density can be performed using an X-ray phase-contrast grating interferometer in a radiographic mode of a homogenous sample in a controlled geometry. A batch of various plastic materials was characterized quantitatively and compared with calculated results. We found that the measured electron densities closely match theoretical values. The technique yields comparable results between a monochromatic and a polychromatic X-ray source. Measured electron densities can be further used to design dedicated X-ray phase contrast phantoms and the additional information on small angle scattering should be taken into account in order to exclude unsuitable materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of electrical signals for plasma etching end point detection: Comparison of end point signals and electron density

Electrical signals are used for end point detection in plasma etching, but the origin of the electrical changes observed at end point is not well understood. As an etch breaks through one layer and exposes an underlayer, the fluxes and densities of etch products and reactants in the gas phase will change. The resulting perturbation in gas composition may alter the plasma electron density, which in turn may affect the electrical signals. Alternatively, changes in substrate electrical properties or surface properties, such as work function or emitted electron yield, may be involved. To investigate these effects, experiments were performed in a radio-frequency (rf)-biased, inductively coupled reactor, during CF{sub 4}/Ar plasma etching of silicon dioxide films on silicon substrates. A complete set of electrical parameters, for the bias as well as the inductive source, was measured and compared. The most useful end point signal was found to be the fundamental rf bias impedance, which decreases when the oxide is removed. A simultaneous increase in plasma electron density was measured by a wave cutoff probe. Analytical sheath models indicate that the measured change in electron density accounts for nearly all of the impedance decrease. The change in electron density can in turn be explained by the effects of etch products or reactants on gas composition. In contrast, electrons emitted from the wafer surface play at most a minor role in the changes in electron density and impedance observed at end point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feedback control of plasma electron density and ion energy in an inductively coupled plasma etcher

Here the authors report the development of a fuzzy logic based feedback control of the plasma electron density and ion energy for high density plasma etch process. The plasma electron density was measured using their recently developed transmission line microstrip microwave interferometer mounted on the chamber wall, and the rf voltage was measured by a commercial impedance meter connected to the wafer stage. The actuators were two 13.56 MHz rf power generators which provided the inductively coupled plasma power and bias power, respectively. The control system adopted the fuzzy logic control algorithm to reduce frequent actuator action resulting from measurement noise. The experimental results show that the first wafer effect can be eliminated using closed-loop control for both poly-Si and HfO{sub 2} etching. In particular, for the HfO2 etch, the controlled variables in this work were much more effective than the previous one where ion current was controlled, instead of the electron density. However, the pressure disturbance effect cannot be reduced using plasma electron density feedback.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of frequency and pulse width on electron density, hydrogen peroxide generation, and perfluorooctanoic acid mineralization in a nanosecond pulsed discharge gas-liquid plasma reactor

Plasma electron density and temperature were characterized in a continuous flowing gas-liquid film reactor with argon carrier gas by time-resolved optical emission spectroscopy. The plasma parameters were studied as a function of time for varying pulse widths and frequencies. Pulse frequency was varied between 1 and 10 kHz at 16 kV (input voltage) and 40 ns (pulse width) using an Eagle Harbor Technologies, Inc. (EHT) power supply and 5–100 kHz using an Airity Technologies, LLC (AT) power supply. The pulse width was varied between 40 and 200 ns at 16 kV, 2 kHz with the EHT power supply. Optimal frequencies of 5 and 20 kHz were observed for peak electron density with EHT and AT power supplies, respectively. The peak electron density increased with increasing pulse width between 40 and 200 ns using the EHT power supply. Hydrogen peroxide exiting the reactor in the liquid phase increased with discharge power irrespective of the power supply or pulse parameters. Mineralization of 12.5, 50, and 200 ppm perfluorooctanoic acid (PFOA) dissolved in DI water to fluoride (F - ) correlated to the peak electron density. Glycerol, a liquid-phase hydroxyl radical scavenger, depleted hydrogen peroxide but did not affect PFOA mineralization. CO, a gas-phase hydroxyl radical scavenger, led to a reduction in the formation of F - production, suggesting hydroxyl radicals in the gas-liquid film play a necessary, but not singular, role in mineralization of PFOA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Universal Solvation Model Based on Solute Electron Density and on a Continuum Model of the Solvent Defined by the Bulk Dielectric Constant and Atomic Surface Tensions

We present a new continuum solvation model based on the quantum mechanical charge density of a solute molecule interacting with a continuum description of the solvent. The model is called SMD, where the “D” stands for “density” to denote that the full solute electron density is used without defining partial atomic charges. “Continuum” denotes that the solvent is not represented explicitly but rather as a dielectric medium with surface tension at the solute-solvent boundary. SMD is a universal solvation model, where “universal” denotes its applicability to any charged or uncharged solute in any solvent or liquid medium for which a few key descriptors are known (in particular, dielectric constant, refractive index, bulk surface tension, and acidity and basicity parameters). The model separates the observable solvation free energy into two main components. The first component is the bulk electrostatic contribution arising from a self-consistent reaction field treatment that involves the solution of the nonhomogeneous Poisson equation for electrostatics in terms of the integral-equation-formalism polarizable continuum model (IEF-PCM). The cavities for the bulk electrostatic calculation are defined by superpositions of nuclear-centered spheres. The second component is called the cavity-dispersion-solvent-structure term and is the contribution arising from short-range interactions between the solute and solvent molecules in the first solvation shell. This contribution is a sum of terms that are proportional (with geometry-dependent proportionality constants called atomic surface tensions) to the solvent-accessible surface areas of the individual atoms of the solute. The SMD model has been parametrized with a training set of 2821 solvation data including 112 aqueous ionic solvation free energies, 220 solvation free energies for 166 ions in acetonitrile, methanol, and dimethyl sulfoxide, 2346 solvation free energies for 318 neutral solutes in 91 solvents (90 nonaqueous organic solvents and water), and 143 transfer free energies for 93 neutral solutes between water and 15 organic solvents. The elements present in the solutes are H, C, N, O, F, Si, P, S, Cl, and Br. The SMD model employs a single set of parameters (intrinsic atomic Coulomb radii and atomic surface tension coefficients) optimized over six electronic structure methods: M05-2X/MIDI!6D, M05-2X/6-31G*, M05-2X/6-31+G**, M05-2X/cc-pVTZ, B3LYP/6-31G*, and HF/6-31G*. Although the SMD model has been parametrized using the IEF-PCM protocol for bulk electrostatics, it may also be employed with other algorithms for solving the nonhomogeneous Poisson equation for continuum solvation calculations in which the solute is represented by its electron density in real space. This includes, for example, the conductor-like screening algorithm. With the 6-31G* basis set, the SMD model achieves mean unsigned errors of 0.6-1.0 kcal/mol in the solvation free energies of tested neutrals and mean unsigned errors of 4 kcal/mol on average for ions with either Gaussian03 or GAMESS.

36 MATERIALS SCIENCE↗

Investigation of the Electron Density Variation During the 21 August 2017 Solar Eclipse

Abstract This paper presents a comparison of modeled and measured electron densities for the 21 August 2017 solar eclipse across the USA. The location of the instrument was (43.81°N, 247.32°E) where the maximum obscuration of 99.6% occurred at 17.53 hr UT on 21 August. The solar apparent time was 9.96 hr, and the duration of the eclipse was 2.7 hr. It was found that if it is assumed that there are no chromosphere emissions at totality, ~30% coronal emission remaining at totality gave the best fit to the electron density variation at 150 km. The 30% coronal emission estimate has uncertainties associated with respect to uncertainties in the solar spectrum, the measured electron density, and the amount of chromosphere emissions remaining at totality. The agreement between the modeled and measured electron densities is excellent at 150 km with the assumed 30% coronal emission at totality. At other altitudes, the agreement is very good, but the altitude profile would be improved if the model peak electron density ( N m F 2 ) decayed more slowly to better match the data. The minimum N m F 2 in the model occurs ~10 min after totality when it decreases to 0.55 from its noneclipse value. The minimum of the N m F 2 data occurs between 6 and 10 min after totality but is ~15% larger. The total electron content decreases to 0.65 of its preeclipse value. These relative changes agree well with those predicted by others prior to the eclipse.

Reinisch, B. W.↗