Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Altus Cumulus Electrification Study (ACES): A UAV-Based Science Demonstration

The Altus Cumulus Electrification Study (ACES) is an unmanned aerial vehicle (UAV)- based project that investigated thunderstorms in the vicinity of the Florida Everglades in August 2002. ACES was conducted to investigate storm electrical activity and its relationship to storm morphology, and to validate satellite-based lightning measurements. In addition, as part of the NASA sponsored UAV-based science demonstration program, this project provided a scientifically useful demonstration of the utility and promise of UAV platforms for Earth science and applications observations. ACES employed the Altus II aircraft, built by General Atomics - Aeronautical Systems, Inc. Key science objectives simultaneously addressed by ACES are to: (1) investigate lightning-storm relationships, (2) study storm electrical budgets, and provide Lightning Imaging Sensor validation. The ACES payload included electrical, magnetic, and optical sensors to remotely characterize the lightning activity and the electrical environment within and around thunderstorms. ACES contributed important electrical and optical measurements not available from other sources. Also, the high altitude vantage point of the UAV observing platform (up to 55,000 feet) provided cloud-top perspective. By taking advantage of its slow flight speed (70 to 100 knots), long endurance, and high altitude flight, the Altus was flown near, and when possible, over (but never into) thunderstorms for long periods of time that allowed investigations to be conducted over entire storm life cycles. An innovative real time weather system was used to identify and vector the aircraft to selected thunderstorms and safely fly around these storms, while, at the same time monitor the weather near our base of operations. In addition, concurrent ground-based observations that included radar (Miami and Key West WSRBD, NASA NPOL), satellite imagery, and lightning (NALDN and Los Alamos EDOT) enable the UAV measurements to be more completely interpreted and evaluated in the context of the thunderstorm structure, evolution, and environment.

Blakeslee, R. J.↗

Preliminary Optical And Electric Field Pulse Statistics From Storm Overflights During The Altus Cumulus Electrification Study

The Altus Cumulus Electrification Study (ACES) was conducted during the month of August, 2002 in an area near Key West, Florida. One of the goals of this uninhabited aerial vehicle (UAV) study was to collect high resolution optical pulse and electric field data from thunderstorms. During the month long campaign, we acquired 5294 lightning generated optical pulses with associated electric field changes. Most of these observations were made while close to the top of the storms. We found filtered mean and median 10-10% optical pulse widths of 875 and 830 microns respectively while the 50-50% mean and median optical pulse widths are 422 and 365 microns respectively. These values are similar to previous results as are the 10-90% mean and median rise times of 327 and 265 microns. The peak electrical to optical pulse delay mean and median were 209 and 145 microns which is longer than one would expect from theoretical results. The results of the pulse analysis will contribute to further validation of the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS) satellites. Pre-launch estimates of the flash detection efficiency were based on a small sample of optical pulse measurements associated with less than 350 lightning discharges collected by NASA U-2 aircraft in the early 1980s. Preliminary analyses of the ACES measurements show that we have greatly increased the number of optical pulses available for validation of the LIS and other orbital lightning optical sensors. Since the Altus was often close to the cloud tops, many of the optical pulses are from low-energy pulses. From these low-energy pulses, we can determine the fraction of optical lightning pulses below the thresholds of LIS, OTD, and any future satellite-based optical sensors such as the geostationary Lightning Mapping Sensor.

Mach, D. A.↗

Lightning Optical Pulse Statistics from Storm Overflights During the Altus Cumulus Electrification Study

The Altus Cumulus Electrification Study (ACES) was conducted during the month of August, 2002 in an area near Key West, Florida. One of the goals of this uninhabited aerial vehicle (UAV) study was to collect time resolved optical pulse data from thunderstorms. During the month long campaign, we acquired 5294 lightning generated optical pulses. Most of these observations were made while close to the top of the storms. We divided our data into two amplitude groups based on prior NASA U2 aircraft optical data and our pulse characteristics. The group of large pulses with radiance greater than 2.1 mW /sq m sr had mean and median 10 - 10% optical pulse widths of 765 and 735 microns respectively, the 50-50% pulse widths of 396 and 355 microns respectively, and 10-90% rise times of 290 and 260 microns. These values are very similar to the previous U2 based optical results The other group of pulses consisting of slightly more than a quarter of the total pulses observed had radiances less than the minimum values detected in the U2 study. The small pulses were narrower than the large pulses with 5040% mean and median values of 198 and 160 ps respectively. Only 12 % of the flashes contained only small pulses, minimizing the impact of this data on the estimates of detection efficiencies of the orbital instruments, the Lightning Imaging Sensor and Optical Transient Detector.

Mach, D. M.↗

Winter Lightning to the Lee of Lake Ontario: The Lake-Effect Electrification (LEE) Field Campaign

The National Science Foundation-sponsored Lake-Effect Electrification (LEE) field campaign intensive observation periods occurred between November and early February 2022-23 across the eastern Lake Ontario region. Project LEE documented, for the first time, the total lightning and electrical charge structures of lake-effect storms and the associated storm environment using a lightning mapping array (LMA), a mobile dual-polarization X-band radar, and balloon-based soundings that measured vertical profiles of temperature, humidity, wind, electric field, and hydrometeor types. LEE also observed abundant wind turbine-initiated lightning, which is climatologically more likely during the winter. The frequent occurrence of intense lake-effect storms and the proximity of a wind farm with nearly 300 turbines each more than 100 m tall to the lee of Lake Ontario provided an ideal laboratory for this study.

Scott M Steiger↗

Creep Performance of Novel Composite Heating Elements for Reheat Furnace Electrification

The iron and steel industry is critical for the modern world but is also very energy intensive and is a low margin industry. Hot rolling requires reheating steel slabs to ~1250 °C for hot rolling and involves yield loss due to scale formation. Electrification of this process using resistive heating could improve yield but is currently not possible due to the poor creep resistance of MoSi2 heating elements, which need to be operated well below their maximum temperatures when mounted horizontally. To solve this problem, novel MoSi2 composite heating elements with SiBCN ceramic reinforcements are being developed using high energy ball milling and spark plasma sintering. The creep performance of different heating elements and their corresponding microstructures and electrical properties will be presented.

36 - MATERIALS SCIENCE↗

Washington Housing Electrification Analysis [Slides]

This technical assistance is part of the Communities Local Energy Action Program (CLEAP) for the community of Beacon Hill, Seattle, WA. This analysis focuses on opportunities to reduce energy burden, energy consumption, and energy bills for both single family homes and large multifamily buildings. It uses state-level data from the ResStock modelling tool that was filtered to be relevant to Beacon Hill. Hence, this content includes single family detached homes and large multifamily buildings in the income group of 0-80% AMI, and climate zone 4c (mixed temperatures, relatively cooler summers) within Washington State.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy impact of heating electrification in mid-rise multifamily buildings in mixed-humid climates

Decarbonizing the electric grid in conjunction with electrifying residential heating is a critical step to combat climate change. Heating in multifamily buildings with the existing natural gas-fired central boiler is a complex process that not only leads to overheating in some apartment units but also results in energy waste and high gas bills. In this study, we consider a multifamily building in New York City, USA, to evaluate the performance of five different heating systems, which represent a step-by-step transition from the conventional to a fully electrified heating system, and determine their impact on the site energy consumption and source CO 2 emissions. Results indicate that overheating in a multifamily building can raise the indoor temperature by as much as 8°C above comfortable limits. Transitioning from conventional steam radiators to cold climate heat pumps can reduce annual site heating energy by up to 70% and source CO 2 emissions by up to 21%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Impacts of Light-Duty and Heavy-Duty Transportation Electrification on a Coordinated Transmission and Distribution System

In this study, we propose a strategy to model the required spatiotemporal charging demand from light-duty (LD) and medium- and heavy-duty (MHD) electric vehicles (EVs) using actual transportation data by mapping the demand for the required EV charging to a realistic and coordinated distribution and transmission electric grid at the predicted times of the day to study their impact on the power system in a variety of load, weather, and EV penetration scenarios. This work is the first study that includes the actual weather data and transportation data with realistic and coordinated distribution and transmission grid data in a large industry-scale level study. The main goal of this study is to identify possible issues and required upgrades in the electric grid, caused by an increase in EV integration. The transmission case study is a large grid with 6717 buses over a Texas footprint, and the distribution grid is over Houston, a city in Texas, covering over three million customers. The resulting overloads and voltage violations experienced in the system are discussed, and required planning upgrades to avoid these issues are suggested.

AC optimal power flow (AC-OPF)↗

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of NLR Automated Mobility District Implementation Research - Phases I, II, and III. The Convergence of Automation, Electrification, and On-Demand Services: Enabling Resilient Automated Mobility Districts

A research program by the National Renewable Energy Laboratory has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings, referred to as Automated Mobility Districts (AMDs). An AMD emphasizes the deployment of automated vehicles (AV) passenger transport services within a dense urban setting and other major activity centers with intense passenger origin-destination demand patterns, such as those found in large business districts, airports, and university and medical campuses. Phase I and II surveyed 10 early deployment sites and subsequently collected and evaluated the lessons learned from these early deployment sites, with particular attention to fleet operations, impacts of service reliability, and vehicle technology evolution as the field of companies was being progressively winnowed by the challenges of full automation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heavy-Duty Nonroad Material Handler Electrification Part 1: Real-World Drive Cycle Development

Knowing a detailed operating cycle is critical for developing and testing equipment. Operating cycles can be separated by two clear distinctions: (1) regulatory or non-regulatory and (2) application at the engine-only or full machine level. The Environmental Protection Agency’s (EPA) Nonroad Transient Cycle (NRTC) may be a good representation of engine use in many types of equipment, but there is a gap in standardized and validated drive cycles specifically for nonroad material handlers. Lacking a standardized drive cycle makes it difficult to accurately benchmark machine performance and validate new powertrain technologies. The objective of this investigation is to illustrate the development of a custom drive cycle augmented with real-world customer use data that serves multiple purposes: (1) understand the range of operation and utilization that formulated inputs for electrified architecture analysis and (2) develop a repetitive and consistent maneuver to establish baseline energy consumption enabling equivalent comparison to future electrified prototype builds. This article presents a solution specifically for a 23-ton nonroad material handler in which material handling, machine transport, and extended idle were homologated to form representative short cycles defined by machine velocity and hydraulic cylinder position. The most intensive material handling short cycles had a load factor of 40% and an average fuel rate of 16 L/h. Combined with a visual aid, the short cycles exhibited low variability, having less than 5% root mean square (RMS) error in lift and reach position with respect to the average. The machine’s performance on these short cycles at the Advanced Power Systems Research Center (APSRC) was compared to results from two real-world customer locations operating the instrumented test machine in a cyclical manner, and for similar ground conditions were found to be comparable in fuel consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗