Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical test and measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Early Burn-In Parasitic Conduction in 500 °C Durable SiC JFET ICs

All prior reports of long-term 500 °C operation of SiC JFET-R ICs have noted the existence of an initial “burn-in” period of changes in measured electrical characteristics for the first few hundred hours oven-testing. This work reports measurements of “burn-in parasitic MOSFET conduction” that can substantially impact the performance of some circuits during initial heat-up of JFET ICs, but then subsequently disappears after a few hours of operation at 500 °C.

silicon carbide↗

Measurement of volt/meter vertical electric fields in the middle atmosphere

A test flight for a series of middle atmosphere electrodynamics rockets was launched from Wallops Island, Virginia, at 7:18 EST on July 31, 1980. The mother-daughter configuration contained a three axis symmetric double probe electric field instrument and a blunt probe on the daughter payload, and a Gerdien condenser and a single axis (vertical) asymmetric double probe electric field instrument on the mother payload. The payloads reached an apogee of 111 km, and data were gathered from all instruments on the downleg. A downward vertical electric field with a maximum amplitude of about 4 V/m was observed in a layer between about 57 and 67 km. The integrated potential across this layer was approximately 20 kV. Conductivity measurements indicated that free electrons were absent from the region of large electric fields; however, the decrease in conductivity was insufficient to maintain vertical current continuity through the layer. These results establish the existence of large mesospheric electric fields, supporting previous results from single axis measurements.

Maynard, N. C.↗

Hall Thruster Plume Measurements On-Board the Russian Express Satellites

The operation of North-South and East-West station-keeping Hall thruster propulsion systems on-board two Russian Express-A geosynchronous communication satellites were investigated through a collaborative effort with the manufacturer of the spacecraft. Over 435 firings of 16 different thrusters with a cumulative run time of over 550 hr were reported with no thruster failures. Momentum transfer due to plume impingement was evaluated based on reductions in the effective thrust of the SPT-100 thrusters and induced disturbance torques determined based on attitude control system data and range data. Hall thruster plasma plume effects on the transmission of C-band and Ku-band communication signals were shown to be negligible. On-orbit ion current density measurements were made and subsequently compared to predictions and ground test data. Ion energy, total pressure, and electric field strength measurements were also measured on-orbit. The effect of Hall thruster operation on solar array performance over several months was investigated. A subset of these data is presented.

Manzella, David↗

Acoustic Measurements for the Moog S-250 Vehicle in Hover

Acoustic measurements for hover conditions and electric motor noise tests were conducted for the Moog S-250 research aircraft, an RPM-controlled quadcopter-type Urban Air Mobility (UAM) vehicle with four sets of contra-rotating rotors. The objectives of the study included determining the minimum far-field distance, the noise characteristics, and the potential for electric motor noise to contribute to the overall acoustic radiation for the full-scale UAM vehicle. Acoustic data for full-scale aircraft are critical for determining the impact of these vehicles on the surrounding communities. The results showed the far-field was reached by 8.1 single rotor diameters or 2.7 vehicle diameters as defined by the longest tip-to-tip rotor dimension for the vehicle. In hover, the peak acoustic radiation occurred at a declination angle of roughly 29° below the midplane between the upper and lower rotors. The lowest acoustic levels occurred below the aircraft. The electric motor noise studies, conducted with the rotors removed, showed motor noise radiated at shaft orders 17 – 20, whereas rotor noise covered the range of 2 – 24 shaft orders. There was some evidence that electric motor noise was present in previous ground run-up measurements.

Urban Air Mobility Noise↗

A Study of the Electrotransport in Thin Films: An Advanced Method for the Study of Electrotransport in Thin Films Using Electrical Resistance Measurements

To date, very little is understood about electrotransport in thin films. One reason for this is the lack of methods in which electromigration can be adequately monitored dynamically. In this thesis, a new nondestructive method for the study of the electrotransport phenomenon in thin aluminum films is presented. This method makes use of electrical resistance measurements of various regions along the test sample to monitor changes in resistance resulting from electromigration. The advantage of this method is that resistance changes can be observed long before void formation can be seen using standard microscopy methods. In order to achieve the best efficiency using this method, special consideration must be given to the design of the sample. Design problems and their respective solutions are given. The results of the electrical resistance measurements are interpreted by means of photographs taken with an scanning electron microscope. The increase in resistance of the aluminum samples is interpreted to be due to void formation. The expected decrease in resistance near the anode was never observed. It is shown that mass accumulation takes on the form of hillocks and whiskers on the surface of the aluminum film, which does not contribute appreciably to conductivity.

Hummel, R. E.↗

Thermoelectric properties of cerium monopnictides

Several cerium pnictides have been synthesized from the pure elements and hot pressed into test samples. Measurements of Seebeck coefficients and electrical resistivities were performed on these samples from room temperature to 1000 C. Cerium arsenide and cerium antimonide are n-type; cerium nitride changes from p-type to n-type conduction at 800 C. The materials are semimetals with resistivities below 1 mohm/cm. Cerium arsenide is the most favorable of the pnictides studied for high-temperature thermoelectric energy conversion, with an average power factor of 15 microW/cm K sq from 500 to 1000 C.

Danielson, L. R.↗

Reliability Assessment of Advanced Flip-clip Interconnect Electronic Package Assemblies under Extreme Cold Temperatures (-190 and -120 C)

Flip-chip interconnect electronic package boards have been assembled, underfilled, non-destructively evaluated and subsequently subjected to extreme temperature thermal cycling to assess the reliability of this advanced packaging interconnect technology for future deep space, long-term, extreme temperature missions. In this very preliminary study, the employed temperature range covers military specifications (-55 C to 100 C), extreme cold Martian (-120 C to 115 C) and asteroid Nereus (-180 C to 25 C) environments. The resistance of daisy-chained, flip-chip interconnects were measured at room temperature and at various intervals as a function of extreme temperature thermal cycling. Electrical resistance measurements are reported and the tests to date have not shown significant change in resistance as a function of extreme temperature thermal cycling. However, the change in interconnect resistance becomes more noticeable with increasing number of thermal cycles. Further research work has been carried out to understand the reliability of flip-chip interconnect packages under extreme temperature applications (-190 C to 85 C) via continuously monitoring the daisy chain resistance. Adaptation of suitable diagnostic techniques to identify the failure mechanisms is in progress. This presentation will describe the experimental test results of flip-chip testing under extreme temperatures.

thermal cycling↗

The Large Area Pulsed Solar Simulator (LAPSS)

The Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, CA, occupies an area measuring about 3 m wide x 12 m long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than plus or minus 2 percent uniformity of irradiance at the test plane and better than plus or minus 0.3 percent measurement repeatability after warm-up. Glass absorption filters reduce the ultraviolet light emitted from the xenon flash lamps. This results in a close match to three different standard airmass zero and airmass 1.5 spectral irradiances. The 2-ms light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices. Since the original printing of this publication, in 1993, the LAPSS has been operational and new capabilities have been added. This revision includes a new section relating to the installation of a method to measure the I-V curve of a solar cell or array exhibiting a large effective capacitance. Another new section has been added relating to new capabilities for plotting single and multiple I-V curves, and for archiving the I-V data and test parameters. Finally, a section has been added regarding the data acquisition electronics calibration.

Mueller, R. L.↗

4.5m GTEM RS105 Test Capability Commissioning

This work details the reconfiguration of the 4.5 m Gigahertz Transverse Electromagnetic test facility at Sandia National Laboratories to operate in accordance with the RS105 (radiated susceptibility) test from MIL-STD-461 representing a high-altitude electromagnetic pulse. This reconfiguration involved removal of the existing continuous wave source and connecting both a high voltage feed and a coaxial feed housing the Marx bank pulser. Marx control settings were calibrated for several voltage levels across two pulsers, and position-dependent measurements of the peak electric field were taken throughout the test volume for each pulser. The results showed field uniformity and purity across the test volume comparable to continuous wave operations, and field peaks were measured from 1.63 kV/m to 54.8 kV/m, with maximum capabilities expected to exceed 100 kV/m. Some challenges in consistent pulser operations at lower Marx bank voltages and high frequency reflections in the system were identified for future capability improvements.

42 ENGINEERING↗

MMS Observatory Thermal Vacuum Results Contamination Summary

The MMS mission is a constellation of 4 observatories designed to investigate the fundamental plasma physics of reconnection in the Earths magnetosphere. Each spacecraft has undergone extensive environmental testing to prepare it for its minimum 2 year mission. The various instrument suites measure electric and magnetic fields, energetic particles, and plasma composition. Thermal vacuum testing was conducted at the Naval Research Laboratory (NRL) in their Big Blue vacuum chamber. The individual spacecraft were tested and enclosed in a cryopanel enclosure called a Hamster cage. Specific contamination control validations were actively monitored by several QCMs, a facility RGA, and at times, with 16 Ion Gauges. Each spacecraft underwent a bakeout phase, followed by 4 thermal cycles. Unique aspects of the TV environment included slow pump downs with represses, thruster firings, Helium identification, and monitoring pressure spikes with Ion gauges. Various data from these TV tests will be shown along with lessons learned.

TV↗

A three-axis flight simulator

A simulator is described, which was designed for testing and evaluating inertial measuring units, and flight platforms. Mechanical and electrical specifications for the outer, middle, and inner axis are presented. Test results are included.

Mason, M. G.↗

Spectral studies of the sources of ionospheric electric fields

Spectral analyses (applying the Fourier analysis methods) were performed on three incoherent scatter radar data sets (obtained at Jicamarca, Peru; Chatanika, Alaska; and Arecibo, Puerto Rico) with the aim of investigating the origin of ionospheric electric fields in the frequency range of 0.01-2 cycles/h. In quiet times, atmospheric gravity waves appeared to be the most likely source of the ionospheric electric field. This hypothesis was tested by a direct simultaneous comparison of measurements of gravity waves in the mesosphere and of electric fields in the thermosphere during very quiet conditions. The results indicated that a gravity wave source is a plausible candidate for the electric field fluctuations.

Earle, G. D.↗

Facility Effects on the Ion Characteristics of A 12.5-Kw Hall Thruster

During a laser-induced fluorescence test of a 12.5-kW magnetically-shielded Hall thruster, ion characteristics in the discharge channel and near the poles were measured as the background pressure and electrical configuration were varied. The acceleration zone of the thruster moved upstream by 2% and 10% of the channel length when the background pressure was raised to 1.8 times and 7 times the lowest achievable pressure, respectively. Examination of the characteristics of the ions near the pole covers suggested that as the background pressure decreased the pole covers may be experiencing more erosion. When operating at a discharge voltage of 300 V, the acceleration zone was observed to be at the same location for all electrical configurations. When operating at a discharge voltage of 600V, the acceleration zone was observed to move 3% of the channel length upstream when the thruster body was floated instead of tied to the cathode or grounded to the facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations. This observation combined with thruster body voltage measurements suggested that varying the electrical configuration only affected the thruster body sheath voltage and did not affect the plasma potential beyond the sheath.

Electric propulsion↗

Packaging Technology Designed, Fabricated, and Assembled for High-Temperature SiC Microsystems

A series of ceramic substrates and thick-film metalization-based prototype microsystem packages designed for silicon carbide (SiC) high-temperature microsystems have been developed for operation in 500 C harsh environments. These prototype packages were designed, fabricated, and assembled at the NASA Glenn Research Center. Both the electrical interconnection system and the die-attach scheme for this packaging system have been tested extensively at high temperatures. Printed circuit boards used to interconnect these chip-level packages and passive components also are being fabricated and tested. NASA space and aeronautical missions need harsh-environment, especially high-temperature, operable microsystems for probing the inner solar planets and for in situ monitoring and control of next-generation aeronautical engines. Various SiC high-temperature-operable microelectromechanical system (MEMS) sensors, actuators, and electronics have been demonstrated at temperatures as high as 600 C, but most of these devices were demonstrated only in the laboratory environment partially because systematic packaging technology for supporting these devices at temperatures of 500 C and beyond was not available. Thus, the development of a systematic high-temperature packaging technology is essential for both in situ testing and the commercialization of high-temperature SiC MEMS. Researchers at Glenn developed new prototype packages for high-temperature microsystems using ceramic substrates (aluminum nitride and 96- and 90-wt% aluminum oxides) and gold (Au) thick-film metalization. Packaging components, which include a thick-film metalization-based wirebond interconnection system and a low-electrical-resistance SiC die-attachment scheme, have been tested at temperatures up to 500 C. The interconnection system composed of Au thick-film printed wire and 1-mil Au wire bond was tested in 500 C oxidizing air with and without 50-mA direct current for over 5000 hr. The Au thick-film metalization-based wirebond electrical interconnection system was also tested in an extremely dynamic thermal environment to assess thermal reliability. The I-V curve1 of a SiC high-temperature diode was measured in oxidizing air at 500 C for 1000 hr to electrically test the Au thick-film material-based die-attach assembly.

Chen, Liang-Yu↗

The Large Area Pulsed Solar Simulator (LAPSS)

A Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, California, occupies an area measuring about 3 meters wide by 12 meters long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than +/- 2 percent uniformity of irradiance at the test plane and better than +/- 0.3 percent measurement repeatability after warm-up. Glass absorption filters are used to reduce the level of ultraviolet light emitted from the xenon flash lamps. This provides a close match to standard airmass zero and airmass 1.5 spectral irradiance distributions. The 2 millisecond light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices.

Mueller, R. L.↗

Preliminary low temperature electron irradiation of triple junction solar cells

JPL has routinely performed radiation testing on commercial solar cells and has also performed LILT testing to characterize cell performance under far sun operating conditions. This research activity was intended to combine the features of both capabilities to investigate the possibility of any room temperature annealing that might influence the measured radiation damage. Although it was not possible to maintain the test cells at a constant low temperature between irradiation and electrical measurements, it was possible to obtain measurements with the cell temperature kept well below room temperature.

annealing↗

Preliminary Low Temperature Electron Irradiation of Triple Junction Solar Cells

For many years extending solar power missions far from the sun has been a challenge not only due to the rapid falloff in solar intensity (intensity varies as inverse square of solar distance) but also because some of the solar cells in an array may exhibit a LILT (low intensity low temperature) degradation that reduces array performance. Recent LILT tests performed on commercial triple junction solar cells have shown that high performance can be obtained at solar distances as great as approx. 5 AU1. As a result, their use for missions going far from the sun has become very attractive. One additional question that remains is whether the radiation damage experienced by solar cells under low temperature conditions will be more severe than when measured during room temperature radiation tests where thermal annealing may take place. This is especially pertinent to missions such as the New Frontiers mission Juno, which will experience cell irradiation from the trapped electron environment at Jupiter. Recent testing2 has shown that low temperature proton irradiation (10 MeV) produces cell degradation results similar to room temperature irradiations and that thermal annealing does not play a factor. Although it is suggestive to propose the same would be observed for low temperature electron irradiations, this has not been verified. JPL has routinely performed radiation testing on commercial solar cells and has also performed LILT testing to characterize cell performance under far sun operating conditions. This research activity was intended to combine the features of both capabilities to investigate the possibility of any room temperature annealing that might influence the measured radiation damage. Although it was not possible to maintain the test cells at a constant low temperature between irradiation and electrical measurements, it was possible to obtain measurements with the cell temperature kept well below room temperature. A fluence of 1E15 1MeV electrons was selected as representative of a moderately high dose that might be expected for a solar powered mission. Fluences much greater than this would require large increases in array area and mass, compromising the ability of PV to compete with non-solar alternatives.

Stella, Paul M.↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗