Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electronic energy gap of molecular hydrogen from electrical conductivity measurements at high shock pressures

Electrical conductivities were measured for liquid D2 and H2 shock compressed to pressures of 10-20 GPa (100-200 kbar), molar volumes near 8 cu cm/mol, and calculated temperatures of 2900-4600 K. The semiconducting energy gap derived from the conductivities is 12 eV, in good agreement with recent quasi-particle calculations and with oscillator frequencies measured in diamond-anvil cells.

Nellis, W. J.↗

Aircraft measurement of electric field - Self-calibration

Aircraft measurement of electric fields is difficult as the electrically conducting surface of the aircraft distorts the electric field. Calibration requires determining the relations between the undistorted electric field in the absence of the vehicle and the signals from electric field meters that sense the local distorted fields in their immediate vicinity. This paper describes a generalization of a calibration method which uses pitch and roll maneuvers. The technique determines both the calibration coefficients and the direction of the electric vector. The calibration of individual electric field meters and the elimination of the aircraft's self-charge are described. Linear combinations of field mill signals are examined and absolute calibration and error analysis are discussed. The calibration method was applied to data obtained during a flight near thunderstorms.

Winn, W. P.↗

High temperature electrical property measurements of ceramics

Emerging applications in energy and aerospace systems require high quality data on the high temperature electrical properties of ceramics, particularly oxides, to guide material selection, design, and modeling. This presentation demonstrates the functionality of a specially designed sample fixture that enables electrical measurements to be conducted up to temperatures as high as 1600°C. Utilizing the mismatch in the coefficient of thermal expansion between two materials, a purely mechanical method for establishing electrical contact in the van der Pauw geometry is used to measure the bulk resistivity of ceramic materials. Measurements conducted on a number of common high temperature materials will be presented, including 20 mol % Gd-doped cerium oxide. Measurements are performed using multiple techniques and compared to literature values finding excellent agreement. The approach described in this work enables the van der Pauw method to be applied to many ceramic materials over a wide range of temperatures and environments.

Cann, David P.↗

High Performance Circuit Pastes for Solid Oxide Fuel Cell Applications: Final Technical Report

Using a combination of in-plane electrical conductivity measurements, electrical contact resistance measurements, tensile fracture tests, double shear lap fracture tests, rapid thermal cycling adhesion tests, in situ wetting angle measurements, 3D X-ray tomography, reduction-oxidation (RedOx) cycling, scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDAX), Density Functional Theory (DFT) modeling, Molecular Dynamics (MD) modeling, and Phase Field modeling, this project determined that a new brazing technique developed by the PIs (specifically the use of nickel particles to direct the wetting and spreading of molten silver) could be used to produce well-adhered, >97% dense, electrically-conductive circuits, current collectors, and/or electrical contacts on a variety of ceramic and ceramic-coated substrates (specifically lanthanum strontium manganite, yttria stabilized zirconia, sapphire, Cr2O3-passivated stainless steel, and Al2O3-passivated stainless steel). Compared to other silver-based alternatives, Ag:Ni led to less manufacturing defects and was more tolerant of the extreme environments (isothermal high-temperature aging) and occasional abuse (rapid thermal cycling and RedOx cycling) encountered during Solid Oxide Fuel Cell and/or Solid Oxide Electrolysis Cell operation. Further, in some situations (such as when to produce Ag:Ni electrical contacts to Al2O3-protected stainless steel) the Ni particles also improved operation by acting as chemical getters that removed electrically-insulating, surface-segregating substrate impurities (i.e. by lowering the contact resistance with the underlying substrate).

36 MATERIALS SCIENCE↗

Electrical conductivity measurements on silicate melts using the loop technique

A new method is described for measurement of the electrical conductivity of silicate melts under controlled oxygen partial pressure at temperatures to 1550 C. The melt samples are suspended as droplets on platinum-rhodium loops, minimizing iron loss from the melt due to alloying with platinum, and providing maximum surface exposure of the melt to the oxygen-buffering gas atmosphere. The latter provides extremely rapid equilibration of the melt with the imposed oxygen partial pressure. The loop technique involves a minimum of setup time and cost, provides reproducible results to within + or - 5% and is well suited to electrical conductivity studies on silicate melts containing redox cations.

Waff, H. S.↗

Interpretation of the electric fields measured in an ionospheric critical ionization velocity experiment

The quasi-dc electric fields measured in the CRIT I ionospheric release experiment are studied. In the experiment, two identical barium shaped charges were fired toward a main payload, and three-dimensional measurements of the electric field inside the streams were made. The relevance of proposed mechanisms for electron heating in the critical ionization velocity (CIV) mechanism is addressed. It is concluded that both the 'homogeneous' and the 'ionizing front' models probably are valid, but in different parts of the streams. It is also possible that electrons are directly accelerated by a magnetic field-aligned component of the electric field. The coupling between the ambient ionosphere and the ionized barium stream is more complicated that is usually assumed in CIV theories, with strong magnetic-field-aligned electric fields and probably current limitation as important processes.

Brenning, N.↗

Electric field measurements at subcritical, oblique bow shock crossings

ISEE-1 electric field measurements at three oblique, subcritical dispersive bow shock crossings are presented. The potential drops across the shock due to the large spatial scale normal component of the electric field were found to vary between 340 and 520 V. The measurements provide the first observations in a space plasma of the oscillations in the normal component of the electric field connected with the whistler precursor phase standing at a collisionless shock. Intense, rapidly varying electric fields with peak amplitudes ranging up to 100 mV/m were observed at the magnetic ramp of the shock in the high time resolution data.

Wygant, J. R.↗

Application of the van der Pauw method for electrical conductivity measurements at high temperatures using an insulating compressing ring

High quality data on the high temperature electrical properties of ceramics, particularly oxides, is of great value for material selection, design, and modeling for a broad range of emerging applications. Utilizing the mismatch in the coefficient of thermal expansion between two materials, a purely mechanical method for establishing electrical contact in the van der Pauw geometry to measure the bulk resistivity of ceramic disks at high temperatures is presented. Measurements of a reference material, 20 mol. % Gd-doped cerium oxide, are presented up to 1000 °C. The viability of electrical measurements up to a maximum temperature of 1600 °C is also considered. Measurements are performed using multiple techniques and compared to literature values finding excellent agreement. Finally, the approach described in this work enables the van der Pauw method to be applied to many ceramic materials over a wide range of temperatures and environments.

47 OTHER INSTRUMENTATION↗

Space charge enhanced plasma gradient effects on satellite electric field measurements

It has been recognized that plasma gradients can cause error in magnetospheric electric field measurements made by double probes. Space charge enhanced Plasma Gradient Induced Error (PGIE) is discussed in general terms, presenting the results of a laboratory experiment designed to demonstrate this error, and deriving a simple expression that quantifies this error. Experimental conditions were not identical to magnetospheric conditions, although efforts were made to insure the relevant physics applied to both cases. The experimental data demonstrate some of the possible errors in electric field measurements made by strongly emitting probes due to space charge effects in the presence of plasma gradients. Probe errors in space and laboratory conditions are discussed, as well as experimental error. In the final section, theoretical aspects are examined and an expression is derived for the maximum steady state space charge enhanced PGIE taken by two identical current biased probes.

Diebold, Dan↗

Electric field measurements of DC-driven positive streamer coronas using the E-FISH method

This paper reports on electric field measurements, using the electric field-induced second harmonic (E-FISH) method, sampling the spatial structure and temporal development of DC-driven positive streamer coronas in atmospheric-pressure air at relevant timescales to examine the self-pulsating behavior of the discharge. The discharge is triggered from a point-to-plate geometry and consists of transient coronas, which bridge the inter-electrode gap and pulsate at about 3 kHz, superimposed with a persisting glow corona. The measurements presented challenge the phenomenological explanation for the pulsations based on field recovery at the anode driven by the evacuation of positive ions by electric drift effects and hint at a propagating wave-like feature from the plate-cathode to the tip-anode.

42 ENGINEERING↗

Global Electric Circuit Implications of Combined Aircraft Storm Electric Current Measurements and Satellite-Based Diurnal Lightning Statistics

Using rotating vane electric field mills and Gerdien capacitors, we measured the electric field profile and conductivity during 850 overflights of thunderstorms and electrified shower clouds (ESCs) spanning regions including the Southeastern United States, the Western Atlantic Ocean, the Gulf of Mexico, Central America and adjacent oceans, Central Brazil, and the South Pacific. The overflights include storms over land and ocean, and with positive and negative fields above the storms. Over three-quarters (78%) of the land storms had detectable lightning, while less than half (43%) of the oceanic storms had lightning. Integrating our electric field and conductivity data, we determined total conduction currents and flash rates for each overpass. With knowledge of the storm location (land or ocean) and type (with or without lightning), we determine the mean currents by location and type. The mean current for ocean thunderstorms is 1.7 A while the mean current for land thunderstorms is 1.0 A. The mean current for ocean ESCs 0.41 A and the mean current for land ESCs is 0.13 A. We did not find any significant regional or latitudinal based patterns in our total conduction currents. By combining the aircraft derived storm currents and flash rates with diurnal flash rate statistics derived from the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) low Earth orbiting satellites, we reproduce the diurnal variation in the global electric circuit (i.e., the Carnegie curve) to within 4% for all but two short periods of time. The agreement with the Carnegie curve was obtained without any tuning or adjustment of the satellite or aircraft data. Given our data and assumptions, mean contributions to the global electric circuit are 1.1 kA (land) and 0.7 kA (ocean) from thunderstorms, and 0.22 kA (ocean) and 0.04 (land) from ESCs, resulting in a mean total conduction current estimate for the global electric circuit of 2.0 kA. Mean storm counts are 1100 for land thunderstorms, 530 for ocean ESCs, 390 for ocean thunderstorms, and 330 for land ESCs.

Mach, Douglas M.↗

Auroral E-fields from DE-1 and -2 at magnetically conjugate points

The results of studies of the electric field measurements from the two Dynamics Explorer satellites are reviewed. There are times at which DE-2 measured electric fields at the auroral ionosphere while DE-1 obtained nearly simultaneous measurement at a higher altitude on the same magnetic field lines. When these electric fields are mapped to a common altitude it is found that the large-scale electric fields are similar, but the small-scale electric fields have a larger amplitude at the higher altitude. Through the use of Fourier analysis it is shown that these results are evidence for a magnetic field-aligned potential drop between the two satellites. While these results were made possible by the satellites' altitude separation, it is also possible to take advantage of the fact that the satellites may pass through the same geomagnetic location with a time separation. This was useful for confirming that sinusoidal electric field oscillations which were detected near one conjunction were due to spatial rather than temporal variations, since similar oscillations were found at the same location at different times. The observed spatial oscillations can be explained by a simple model of magnetosphere-ionosphere coupling.

Weimer, D. R.↗

Simultaneous electric-field measurements on nearby balloons.

Electric-field payloads were flown simultaneously on two balloons from Great Whale River, Canada, on September 21, 1971, to provide data at two points in the upper atmosphere that differed in altitude by more than one atmospheric density scale height and in horizontal position by 30-140 km. The altitude dependences in the two sets of data prove conclusively that the vertical electric field at balloon altitudes stems from fair-weather atmospheric electricity sources and that the horizontal fields are mapped down ionospheric fields, since the weather-associated horizontal fields were smaller than 2 mV/m.

Mozer, F. S.↗

Direct comparison between satellite electric field measurements and the visual aurora

Electric field data from two passes of the Injun 5 satellite, one corresponding to magnetically quiet conditions and one corresponding to substorm conditions, are compared with simultaneous all-sky camera data from College, Alaska. In each case, a significant deviation of the electric field from the expected V x B field (where V is the satellite velocity) was evident, and a distinct electric field reversal could be identified. In the region of substantial electric field equatorward of the electric field reversal, a diffuse auroral arc was observed during the magnetically quiet pass, and auroral patches were observed during the substorm pass. In the substorm case, the electric field reversal occurred very near a discrete auroral arc at the poleward side of the diffuse arcs and patches. Comparison of the quiet time and substorm cases suggests that the convection electric field penetrates deeper into the magnetosphere during a substorm.

Swift, D. W.↗

Impulse Measurements of Electric Solid Propellant in an Electrothermal Ablation-Fed Pulsed Plasma Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled and extinguished) through the application and removal of an electric current. These propellants are also being considered for use in the ablative pulsed plasma thruster. In this paper, the performance of an electric solid propellant operating in an electrothermal ablation-fed pulsed plasma thruster was investigated using an inverted pendulum micro-Newton thrust stand. The impulse bit and specific impulse of the device using the electric solid propellant were measured for short-duration test runs of 100 pulses and longer-duration runs to end-of-life, at energy levels of 5, 10, 15 and 20 J. Also, the device was operated using the current state-of-the-art ablation-fed pulsed plasma thruster propellant, polytetrafluoroethylene or PTFE. Impulse bit measurements for PTFE indicate 100±20 μN-s at an initial energy level of 5 J, which increases linearly by ~30 μN-s/J with increased initial energy. Measurements of the impulse bit for the electric solid propellant are on average lower than PTFE by 10% or less. Specific impulse for when operating on PTFE is calculated to be about 450 s compared to 225 s for the electric solid propellant. The 50% reduction in specific impulse is due to increased mass ablated during operation with the electric solid propellant relative to PTFE.

Glascock, Matthew S.↗