Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “earth system interface processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

77 records · Page 5

A network of soil moisture, soil temperature, air temperature, net radiation, ground heat flux and ground water for Chicago, Illinois

This dataset contains environmental monitoring data collected using solar-powered Multi-Function Research (MFR) Long Range Wide Area (LoRaWAN)-enabled nodes at 11 sites in Chicago, Illinois, as part of the DOE Urban Integrated Field Lab CROCUS project. The MFR node system consists of an Input/Output Digital Input Module (IB8) interface box (ICT International) providing wired connections for environmental sensors and an MFR-Node-L data logger that manages power, data processing, and LoRaWAN communication. The wireless data are ingested via Sage network (https://sagecontinuum.org/) nodes that contain LoRaWAN antennae. Measurements were collected from 11 MFR nodes deployed across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), West Woodlawn "Blacks in Green" (BIG), and Indian Boundary Prairies (IBP). Each MFR node supports a consistent suite of sensors measuring atmospheric, soil, and hydrological variables. Atmospheric measurements include 2m air temperature (°C), 2m vapor pressure deficit (kPa), and 2m shortwave/longwave radiation (incoming and outgoing, W/m²) measured using ATH-VPD and Apogee SN500 sensors. Soil measurements include volumetric water content (VWC, %) and temperature (°C) at four depths (15, 30, 45, and 60 cm below surface) using Meter Teros54 sensors, and heat flux (W/m²) at 10 cm depth using Huske HFP01-05 sensors. At selected locations, Meter Hydros21 sensors measure groundwater depth (mm), specific conductivity (dS/m), and temperature (°C). The dataset includes timestamps, site identifiers with location names, device IDs, Global Positioning System (GPS) coordinates, variable names with units, measurement depths, values, sensor names, and Sage node identifiers. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 6-bit binary system indicating physical range violations, step spikes, 24-hour flat-line conditions, 6-hour jitter, 7-day ultra-low variance, and persistent high offset. Data is provided in CSV and CF-compliant NetCDF formats. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Sap Flow Meter (SFM1x) sensors.

Chicago↗

COMPASS-FME Synoptic Site Characterization

This dataset contains soil biogeochemical and physicochemical characterization data for the COMPASS-FME synoptic sites.This dataset also contains data for the paper Patel et al. 2025 "Transition zones at the changing coastal terrestrial-aquatic interface", https://doi.org/10.1029/2025JG008978.Coastal soils are a significant but highly uncertain component of global biogeochemical cycles. These systems experience unique spatial and temporal variability in biogeochemical processes, driven by wetland-to-upland gradients and hydrological fluctuations. We studied drivers of coastal soil variability (a) at regional scales and (b) across transects from upland forest to wetland, in two contrasting regions — Lake Erie, a freshwater lacustrine system, and Chesapeake Bay, a saltwater estuarine system. Salinity-related analytes were a key driver of soil variability, not just in the saltwater system, but surprisingly, also in the freshwater system. We had hypothesized linear trends in biogeochemical parameters along the TAI – however, contrary to expectations, transition soils were not consistently intermediate between upland and wetland endmembers; the non-monotonic trends of carbon, phosphorus, iron along our transects suggest that these are key analytes to study in our regions. Rapidly changing soil factors across coastal gradients provide insights into which soil processes may act as precursors to ecosystem shifts. Our comprehensive soil characterization across the coastal transects provides essential data for mechanistic modeling of ecosystem dynamics.The data are provided as processed, csv files. Raw data and processing scripts can be accessed on GitHub (https://github.com/COMPASS-DOE/cmps-soil_characterization).A note on the nomenclature: the experimental design represents three points along the coastal gradient -- upland, transition, and wetland. "wetland" is referred to as "marsh" in the corresponding paper. The two terms can be used interchangeably for the sites in this study.

54 ENVIRONMENTAL SCIENCES↗

Data for: A Synoptic System for Capturing Ecosystem Control Points Across Terrestrial-Aquatic Interfaces

The investigation of how climate change and water level fluctuations impact variable and interconnected ecosystems, like the interfaces between terrestrial and aquatic environments, requires the collection and integration of many data types. We describe an integrative and autonomous environmental monitoring approach that uses environmental sensors and data loggers to monitor surface water, groundwater, soil, and vegetation changes and generate essential data for predictive models. We established the network at seven sites along the Chesapeake Bay and Lake Erie coastlines, including a large-scale flood manipulation experiment, collectively generating over three million observations per month. Such sensor networks hold great promise for tracking and comprehending environmental changes where land and water intersect. The sensor system and overall approach to sensor management that we have designed is intended to be widely accessible for research teams spanning in size from an individual investigator to large multi-institution projects. This dataset shows example data generated by the sensor network described above. Data output for data loggers connected to groundwater water quality sondes measuring dissolved oxygen, pH, oxidative redox potential (ORP), groundwater elevation, groundwater salinity and temperature, and groundwater elevation; replicate soil moisture and conductivity probes installed at 10 and 30 cm below the ground surface; rainfall and solar radiation; and mean sap flow from 8 replicate probes. Sensors are installed at upland forest (UP), wetlands (W), and transitional locations between these ecosystems (TR). Example datasets are from Goodwin Islands in the Chesapeake Bay and Portage River along the Lake Erie coastline.

54 ENVIRONMENTAL SCIENCES↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗