Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Graphite-Embedded High-Performance Insulated Metal Substrate for Wide-Bandgap Power Modules

Emerging wide-bandgap (WBG) semiconductor devices such as silicon carbide (SiC) metal–oxide semiconductor field-effect transistors (MOSFETs) and gallium nitride high-electron-mobility transistors can handle high power in reduced semiconductor areas better than conventional Si-based devices owing to superior material properties. With increased power loss density in a WBG-based converter and reduced die size in power modules, thermal management of power devices must be optimized for high performance. Here, we present a graphite-embedded insulated metal substrate (thermally-annealed-pyrolytic-graphite-embedded insulated metal substrate—IMSwTPG) designed for WBG power modules. Theoretical thermal performance analysis of graphite-embedded metal cores is presented, with design details for IMSwTPG with embedded graphite to replace a direct-bonded copper (DBC) substrate. The proposed IMSwTPG is compared with an aluminum nitride-based DBC substrate using finite-element thermal analysis for steady-state and transient thermal performance. The solutions’ thermal performances are compared under different coolant temperature and thermal loading conditions, and the proposed substrate's electrical performance is validated with static and dynamic characterization. Using graphite-embedded substrates, junction-to-case thermal resistance of SiC MOSFETs can be reduced up to 17%, and device current density can be increased by 10%, regardless of the thermal management strategy used to cool the substrate. Reduced transient thermal impedance of up to 40% of dies owing to increased heat capacity is validated in transient thermal simulations and experiments. The half-bridge power module's electrical performance is evaluated for on -state resistance, switching performance, and switching loss at three junction temperature conditions. The proposed substrate solution has minimal impact on conduction and switching performance of SiC MOSFETs.

42 ENGINEERING↗

Preliminary testing of a SNAP-19 TAGS RTG in support of the Pioneer F and G missions.

This paper presents the results of a preliminary performance evaluation of the SNAP-19 TAGS thermoelectric generator which was selected as the power source for the Pioneer Space Flight Mission. The performance of the SNAP-19 generator was evaluated at various input powers and fin-root temperatures. Results of this evaluation are analyzed and discussed. Tests were also performed to provide the Pioneer Flight Project Management with applicable data such as generator thermal dynamic behavior during launch and prior to deployment. These special tests measure generator performance as a function of fin-root temperature and the dynamic frequency response of the generator.

Stapfer, G.↗

Thermal Ablation Modeling for Silicate Materials

A general thermal ablation model for silicates is proposed. The model includes the mass losses through the balance between evaporation and condensation, and through the moving molten layer driven by surface shear force and pressure gradient. This model can be applied in the ablation simulation of the meteoroid and the glassy ablator for spacecraft Thermal Protection Systems. Time-dependent axisymmetric computations are performed by coupling the fluid dynamics code, Data-Parallel Line Relaxation program, with the material response code, Two-dimensional Implicit Thermal Ablation simulation program, to predict the mass lost rates and shape change. The predicted mass loss rates will be compared with available data for model validation, and parametric studies will also be performed for meteoroid earth entry conditions.

Ablation↗

Dynamic Atomistic Polar Structure Underpins Ultrahigh Linear Electro-Optic Coefficient in Transparent Ferroelectric Ceramics

Transparent ferroelectrics with high linear electro-optic (EO) coefficients are critical for advanced electro-optical devices. However, achieving optical transparency in ferroelectric ceramics remains challenging due to visible light scattering caused by defects such as domain walls, grain boundaries, and pores. Here, we report the successful fabrication of transparent ferroelectric ceramics through innovative chemical composition design and an advanced two-step sintering process in the La-doped Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 system. The optical transparency, which is near the theoretical upper limit, can be attributed to the wide band gap and the minimization of light scattering of defects. By minimizing porosity and engineering grain/domain sizes to differ significantly from the wavelengths of visible light, we suppress scattering, achieving optical transparency near the theoretical upper limit. Strikingly, these ceramics exhibit an ultrahigh linear EO coefficient of ∼1417 pm/V, over 65 times greater than that of LiNbO 3 single crystals, the current industry standard. We attribute this exceptional performance to dynamic atomistic polar structures within switchable, thermally stable domains, which enhance electronic polarization sensitivity. This mechanism is corroborated by dielectric spectroscopy, high-resolution transmission electron microscopy and simulation. Our findings offer insights into the design of cost-effective transparent materials with exceptional EO properties, paving the way for next-generation electro-optical devices.

36 MATERIALS SCIENCE↗

Modelling a Motor Cooling System with Stator Lamination Fins

This work investigates the potential for cooling a radial permanent magnet motor by means of stator lamination fins. To form the fins, certain stator laminations have a larger external diameter. The optimal number of fins, as well as fm thickness, was determined to reach the maximal heat transfer between the motor stator and the coolant. Finite element and computational fluid dynamics modelling were used to calculate the thermal performance of the motor.

ENGINEERING↗

Hydrogen-oxygen auxiliary propulsion for the space shuttle. Volume 1: High pressure thrusters

Technology for long life, high performing, gaseous hydrogen-gaseous oxygen rocket engines suitable for auxiliary propulsion was provided by a combined analytical and experimental program. Propellant injectors, fast response valves, igniters, and regeneratively and film-cooled thrust chambers were tested over a wide range of operating conditions. Data generated include performance, combustion efficiency, thermal characteristics film cooling effectiveness, dynamic response in pulsing, and cycle life limitations.

Source record↗

Thermoelectric Converter for Loop Heat Pipe Temperature Control: Experience and Lessons Learned

This paper describes the theoretical background and implementation methodology of using a thermoelectric converter (TEC) for operating temperature control of a loop heat pipe (LHP). In particular, experimental results from ambient and thermal vacuum tests of an LHP are presented for illustrations. The most commonly used state-of-the-art method to control the LHP operating temperature is to cold bias its compensation chamber (CC) and use an electrical heater to maintain the CC at the desired set point temperature. Although effective, this approach has its shortcomings in that the electrical heater can only provide heating to the CC, and the required power can be large under certain conditions. An alternative method is to use a TEC, which is capable of providing both heating and cooling to the CC. In this method, one side of the TEC is attached to the CC, and the other side is connected to the evaporator via a thermal strap. Using a bipolar power supply and a control algorithm, a TEC can function as a heater or a cooler, depending on the direction of the current flow. Extensive ground tests of several LHPs have demonstrated that a TEC can provide very tight temperature control for the CC. It also offers several additional advantages: (1) The LHP can operate at temperatures below its natural operating temperature at low heat loads; (2) The required heater power for a TEC is much less than that for an electrical heater; and (3) It enhances the LHP start-up success. Although the concept of using a TEC for LHP temperature control is simple, there are many factors to be considered in its implementation for space applications because the TEC is susceptible to the shear stress and yet has to sustain the dynamic load under the spacecraft launch environment. The added features that help the TEC to withstand the dynamic load will inevitably affect the TEC thermal performance. Some experiences and lessons learned are addressed in this paper.

Ku, Jentung↗

Wide-Field Infrared Survey Telescope (WFIRST) Integrated Modeling

Contents: introduction to WFIRST (Wide-Field Infrared Survey Telescope) and integrated modeling; WFIRST stability requirement summary; instability mitigation strategies; dynamic jitter results; STOP (structural-thermal-optical performance) (thermal distortion) results; STOP and jitter capability limitations; model validation philosophy.

Integrated Modelin↗

Effects of pointing errors on receiver performance for parabolic dish solar concentrators

The effects of dynamic (moving) pointing errors on the performance of solar thermal receivers is investigated. Only point focusing types of solar collectors are considered. The key element in the study is the analytical derivation of the intercept factor that relates pointing errors to captured energy at the receiver. A detailed example using typical parameter values is modeled on the digital computer and demonstrates the theory and the dynamic nature of the problem.

Hughes, R. O.↗

Integrated Computational Fluid Dynamics and Thermal Desktop Thermal Modeling for Assessment of the EMU in Support of ISS EVA 80

Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.

Blain Ryan Lancaster↗

Integrated Computational Fluid Dynamics and Thermal Desktop Thermal Modeling for Assessment of the EMU in Support of ISS EVA 80

Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.

EVA 80↗

Quantum simulation of nonequilibrium dynamics and thermalization in the Schwinger model

In this work, we present simulations of nonequilibrium dynamics of quantum field theories on digital quantum computers. As a representative example, we consider the Schwinger model, a (1+1)-dimensional U(1) gauge theory, coupled through a Yukawa-type interaction to a thermal environment described by a scalar field theory. We use the Hamiltonian formulation of the Schwinger model discretized on a spatial lattice. With the thermal scalar fields traced out, the Schwinger model can be treated as an open quantum system and its real-time dynamics are governed by a Lindblad equation in the Markovian limit. The interaction with the environment ultimately drives the system to thermal equilibrium. In the quantum Brownian motion limit, the Lindblad equation is related to a field theoretical Caldeira-Leggett equation. By using the Stinespring dilation theorem with ancillary qubits, we perform studies of both the nonequilibrium dynamics and the preparation of a thermal state in the Schwinger model using IBM's simulator and quantum devices. The real-time dynamics of field theories as open quantum systems and the thermal state preparation studied here are relevant for a variety of applications in nuclear and particle physics, quantum information and cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal shock resistance of multilayer silicon carbide receiver tubes for 800°C molten salt concentrating solar power application

CSP power tower receiver systems during rapid transient weather periods can be vulnerable to thermal shock conditions from rain that which can facilitate the onset of leaks and failures that can have catastrophic consequences. Silicon carbide (SiC) materials have attractive receiver application characteristics for being light weight, having high-strength and excellent thermal shock resistance performance which make them a particularly good fit for receiver absorber materials in CSP. In this investigation, the performance characteristics of Ceramic Tubular Products (CTP) SiC ceramic matrix composite (CMC), multilayered tubes were explored with respect to thermal shock performance for solar receiver applications in next generation CSP plants. Here, thermal shock testing was performed at the Sandia National Laboratories (SNL) Solar Furnace facility using a dynamic stage and thermal shock tube test setup. The tubes tested under incident solar heat flux of 100 W/cm2 were heated with inner tube temperatures reaching approximately 800 °C, with outer temperatures exceeding or just reaching 1000 El for the multilayer and monolithic SiC tubes respectively. The tubes were then quenched with simulated rain. The tubes were then cooled and subjected to hoop stress analysis using an Instron device to assess their subsequent mechanical strength. Furthermore, the on-sun study experimental results indicate an average of 24.2% and 97% higher hoop strength for the CMC tubes than those composed of monolithic SiC and aluminum oxide (A1203) respectively.

14 SOLAR ENERGY↗

Thin film strain gage development program

Sputtered thin-film dynamic strain gages of 2 millimeter (0.08 in) gage length and 10 micrometer (0.0004 in) thickness were fabricated on turbojet engine blades and tested in a simulated compressor environment. Four designs were developed, two for service to 600 K (600 F) and two for service to 900 K (1200 F). The program included a detailed study of guidelines for formulating strain-gage alloys to achieve superior dynamic and static gage performance. The tests included gage factor, fatigue, temperature cycling, spin to 100,000 G, and erosion. Since the installations are 30 times thinner than conventional wire strain gage installations, and any alteration of the aerodynamic, thermal, or structural performance of the blade is correspondingly reduced, dynamic strain measurement accuracy higher than that attained with conventional gages is expected. The low profile and good adherence of the thin film elements is expected to result in improved durability over conventional gage elements in engine tests.

Grant, H. P.↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Origin of Intrinsically Low Thermal Conductivity in a Garnet-Type Solid Electrolyte: Linking Lattice and Ionic Dynamics with Thermal Transport

Understanding thermal transport in solid electrolytes is essential for improving the performance, reliability, and safety of all-solid-state batteries. Garnet-type lithium-ion conductors are promising candidates for solid electrolytes, yet their thermal-transport mechanisms remain poorly understood. Here, we connect the lattice and ion dynamics of single-crystal garnet-type Li 6.5 La 3 Zr 1.5 Ta 0.5 O 12 to its intrinsically low thermal conductivity. Our study reveals that the single crystals grown by the floating-zone method exhibit remarkably low glasslike thermal conductivity. Using first-principles calculations and inelastic-neutron-scattering measurements, we identify both the acoustic and numerous optical phonon modes, which stem from the complex crystal structure of the material. Notably, a low-energy optical branch exhibits an avoided crossing with acoustic phonons near 7 meV. These optical modes can enhance the scattering of heat-carrying acoustic phonons and reduce thermal conductivity. Furthermore, the calculated Grüneisen parameters are large, especially for the vibrational modes around 6 meV, indicating strong anharmonicity, with a noticeable contribution from lithium-ion vibrations. A two-channel thermal-transport model is employed to describe the weak temperature dependence of the thermal conductivity, which can be attributed to the substantial contribution of diffuson transport facilitated by the abundance of optical phonons and intrinsic anharmonicity. These results offer valuable insights into the thermal transport in a broad class of ionic conductors of interest for energy conversion and storage applications.

Ab initio calculations↗

ECAR-8055 Rev 0 Verification and Validation of Star-CCM+ for Computational Fluid Dynamics Analyses for the MARVEL Microreactor

The objective of this Engineering Calculations and Analysis Report (ECAR) is to provide documentation and highlight relevant information regarding the verification and validation (V&V) of the commercial computational fluid dynamics (CFD) code STAR-CCM+ for the thermal and fluids analyses performed for the MARVEL microreactor.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗