Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Beam Stability Overview [Slides]

Radiographic spot size is affected by many factors, including beam motion due to instabilities. Instabilities and effects that can influence the radiation-source spot size are being evaluated for the Scorpius flash-radiography accelerator. The Scorpius LIA design has a direct influence on beam stability. Many features of the design were specifically incorporated to mitigate instability. The major beam dynamics concerns for high-current LIAs are being evaluated for the long, 102-cell Scorpius design. For these results, all tools available were used including experimental data, analytic theory, and physics simulation codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark Field Proton Radiography (Los Alamos LDRD Report)

Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗

Experimental Observations of Laser-Driven Tin Ejecta Microjet Interactions

The study of high-velocity particle-laden flow interactions is of importance for the understanding of a wide range of natural phenomena, ranging from planetary formation to cloud interactions. Experimental observations of particle dynamics are sparse given the difficulty of generating high-velocity flows of many particles. Ejecta microjets are micron-scale jets formed by strong shocks interacting with imprinted surfaces to generate particle plumes traveling at several kilometers per second. As such, the interaction of two ejecta microjets provides a novel experimental methodology to study interacting particle streams. In this Letter, we report the first time sequences of x-ray radiography images of two interacting tin ejecta microjets taken on a platform designed for the OMEGA Extended Performance (OMEGA EP) laser. We observe that the microjets pass through each other unattenuated for the case of 11.7±3.2 GPa shock pressures and jet velocities of 2.2±0.5 km/s but show strong interaction dynamics for 116.0±6.1 GPa shock pressures and jet velocities of 6.5±0.5 km/s. Furthermore, we find that radiation-hydrodynamic simulations of the experiments are able to capture many aspects of the collisional behavior, such as the attenuation of jet velocity in the direction of propagation, but are unable to match the full spread of the strongly interacting cloud.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic fracture of glass fiber-reinforced ductile polymer matrix composites and loading rate effect

Here, the dynamic fracture of S-2 glass fiber-reinforced polymer matrix composites (FRPMCs) was investigated in this study. The matrix ductility was improved by a recently developed network topology modification technique via mixing partially reacted substructures (mPRS). The composite material was manufactured and characterized by micro-CT scanning and scanning electron microscopy (SEM). Dynamic single-edge notched bending (d-SENB) experiments were performed on the composites by using a modified split-Hopkinson pressure bar. Each specimen’s fracture process was visualized by ultrafast X-ray imaging. Such in-situ radiography enabled identifying the damage initiation below 50-micron scale and inspecting its propagation through the internal structures of opaque composites, thereby accurately quantifying the composites’ mechanical properties. Furthermore, the identical d-SENB experiments were designed and the digital image correlation (DIC) was employed to monitor the stress wave propagation on the composite specimens. The force and deflection measurements were modified and correlated to the physical damage processes. Besides, quasi-static SENB experiments were conducted to identify the loading rate effects on the composites’ fracture behaviors. The force and deflection history, bending stiffness, energy dissipation, and fracture toughness at different loading rates were quantified and compared. Finally, post-fracture analysis by micro-CT scanning and SEM provided physical observations on the variation of the fracture morphology by different loading rates.

42 ENGINEERING↗

K-Modules

K-Modules are capacitive energy modules designed to be stacked together to form a capacitor bank (aka a Marx bank). Discharging the stack produces a single, high voltage, high current pulse that when coupled to an X-ray (or electron) tube, produces energetic X-rays (or an intense electron beam, E-beam). The energetic X-rays are used in Flash X-ray Radiography (FXR), a technique to image objects moving at extremely high speed to measure their speed, shape and internal density profiles. The images help validate computer models for materials behavior under extreme pressure and temperature. FXR is a technology critical to dynamic experiments for the national security mission, and most users are DOE and DOD labs. Febetrons, the X-ray generating devices, are used at these sites and rely on capacitive energy modules for their operation. A stack of the newly developed K-modules will significantly extend the capabilities of these Febetrons

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct imaging of shock wave splitting in diamond at Mbar pressure

Understanding the behavior of matter at extreme pressures of the order of a megabar (Mbar) is essential to gain insight into various physical phenomena at macroscales—the formation of planets, young stars, and the cores of super-Earths, and at microscales—damage to ceramic materials and high-pressure plastic transformation and phase transitions in solids. Under dynamic compression of solids up to Mbar pressures, even a solid with high strength exhibits plastic properties, causing the induced shock wave to split in two: an elastic precursor and a plastic shock wave. This phenomenon is described by theoretical models based on indirect measurements of material response. The advent of x-ray free-electron lasers (XFELs) has made it possible to use their ultrashort pulses for direct observations of the propagation of shock waves in solid materials by the method of phase-contrast radiography. However, there is still a lack of comprehensive data for verification of theoretical models of different solids. Here, we present the results of an experiment in which the evolution of the coupled elastic–plastic wave structure in diamond was directly observed and studied with submicrometer spatial resolution, using the unique capabilities of the x-ray free-electron laser (XFEL). The direct measurements allowed, for the first time, the fitting and validation of the 2D failure model for diamond in the range of several Mbar. Our experimental approach opens new possibilities for the direct verification and construction of equations of state of matter in the ultra-high-stress range, which are relevant to solving a variety of problems in high-energy-density physics.

36 MATERIALS SCIENCE↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

The MURAVES Experiment: A Study of the Vesuvius Great Cone with Muon Radiography

The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help the modeling of possible eruptive dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low-energy muons. The apparatus is currently acquiring data. Preliminary results from the analysis of the first data sample are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗

Neutron generation dynamics inside a MA-class dense plasma focus Z-pinch

Dense plasma focii (DPFs) are appealing as energy efficient sources of short pulses of ions, neutrons, and x rays. The output of these sources is expected to scale with input current (I4), but has been shown to drop at the MA level [S. K. H. Auluck, “On the failure of neutron yield scaling in the dense plasma focus,” Phys. Plasmas 30, 080701 (2023)]. New results on the MegaJOuLe Neutron Imaging Radiography DPF showed neutron yield production in agreement with the input current scaling beyond the previously observed drop. This work provides insight into the pinch formation on a DPF and reports on the two different mechanisms leading to neutron generation inside a DPF using a combination of kinetic simulations and experimental data. A combination of particle-in-cell (PIC) and 1D shock theory results are used to describe the pinch formation and disassembly and the corresponding thermonuclear and beam-target mechanisms. The temporal evolution of the pinch column predicted by the PIC simulations shows qualitative agreement with the experimental data from plasma photon emission as well as temporal neutron pulse shapes. In MJ-class DPFs, both thermonuclear and beam-target mechanisms can occur over the course of the implosion and contribute to the total neutron production. Hence the neutron source size of a DPF will change throughout the implosion. Experimental neutron radiographs show the increase in source size as the pinch breaks apart, in agreement with simulation's prediction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Explosion dynamics of thin flat foils at high current density

This paper presents characteristic features of the explosion of thin flat foils for currents and pulse risetimes ranging from 8 kA at 350 ns to 1000 kA at ~100 ns. Foils made of aluminum, copper, nickel, and titanium with thicknesses of 1–100 µm are tested. Various diagnostics in the optical, UV, and x-ray spectral ranges are used to image the exploding foils from initial breakdown to complete destruction or pinching. It is shown that foil explosion is a complex process that depends on many factors, but features common to all foils are found that do not depend on the parameters of the generators or, accordingly, on the energy deposited in the foil: for example, the breakdown of flat foils under different conditions occurs at the edges of the foil. For the first time, the formation of a precursor over the central part of the foil is shown, which significantly changes the dynamics of the foil explosion.

36 MATERIALS SCIENCE↗

On the study of hydrodynamic instabilities in the presence of background magnetic fields in high-energy-density plasmas

Blast-wave-driven hydrodynamic instabilities are studied in the presence of a background B-field through experiments and simulations in the high-energy-density (HED) physics regime. In experiments conducted at the Laboratoire pour l’utilisation des lasers intenses (LULI), a laser-driven shock-tube platform was used to generate a hydrodynamically unstable interface with a prescribed sinusoidal surface perturbation, and short-pulse x-ray radiography was used to characterize the instability growth with and without a 10-T B-field. The LULI experiments were modeled in FLASH using resistive and ideal magnetohydrodynamics (MHD), and comparing the experiments and simulations suggests that the Spitzer model implemented in FLASH is necessary and sufficient for modeling these planar systems. These results suggest insufficient amplification of the seed B-field, due to resistive diffusion, to alter the hydrodynamic behavior. Although the ideal-MHD simulations did not represent the experiments accurately, they suggest that similar HED systems with dynamic plasma-β (=2μ0ρv2/B2) values of less than ∼100 can reduce the growth of blast-wave-driven Rayleigh–Taylor instabilities. These findings validate the resistive-MHD FLASH modeling that is being used to design future experiments for studying B-field effects in HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗