Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dye sensitization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Nanorod-Based Fast-Response Pressure-Sensitive Paints

A proposed program of research and development would be devoted to exploitation of nanomaterials in pressuresensitive paints (PSPs), which are used on wind-tunnel models for mapping surface pressures associated with flow fields. Heretofore, some success has been achieved in measuring steady-state pressures by use of PSPs, but success in measuring temporally varying pressures has been elusive because of the inherent slowness of the optical responses of these materials. A PSP contains a dye that luminesces in a suitable wavelength range in response to photoexcitation in a shorter wavelength range. The luminescence is quenched by oxygen at a rate proportional to the partial pressure of oxygen and thus proportional to the pressure of air. As a result, the intensity of luminescence varies inversely with the pressure of air. The major problem in developing a PSP that could be easily applied to a wind-tunnel model and could be useful for measuring rapidly varying pressure is to provide very high gas diffusivity for rapid, easy transport of oxygen to and from active dye molecules. Most PSPs include polymer-base binders, which limit the penetration of oxygen to dye molecules, thereby reducing responses to pressure fluctuations. The proposed incorporation of nanomaterials (somewhat more specifically, nanorods) would result in paints having nanostructured surfaces that, relative to conventional PSP surfaces, would afford easier and more nearly complete access of oxygen molecules to dye molecules. One measure of greater access is effective surface area: For a typical PSP as proposed applied to a given solid surface, the nanometer-scale structural features would result in an exposed surface area more than 100 times that of a conventional PSP, and the mass of proposed PSP needed to cover the surface would be less than tenth of the mass of the conventional PSP. One aspect of the proposed development would be to synthesize nanorods of Si/SiO2, in both tangle-mat and regular- array forms, by use of chemical vapor deposition (CVD) and wet chemical processes, respectively. The rods would be coated with a PSP dye, and the resulting PSP signals would be compared with those obtained from PSP dye coats on conventional support materials. Another aspect of the proposed development would be to seek to exploit the quantum properties of nanorods of a suitable semiconductor (possibly GaN), which would be synthesized by CVD. These quantum properties of semiconductor nanorods include narrow-wavelength-band optical absorption and emission characteristics that vary with temperature. The temperature sensitivity might enable simultaneous measurement of fluctuating temperature and pressure and to provide a temperature correction for the PSP response.

Bencic, Timothy↗

Tunable lasers and their application in analytical chemistry

The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.

Steinfeld, J. I.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

Exposed Phosphatidylserine as a Biomarker for Clear Identification of Breast Cancer Brain Metastases in Mouse Models

Brain metastasis is the most common intracranial malignancy in adults. The prognosis is extremely poor, partly because most patients have more than one brain lesion, and the currently available therapies are nonspecific or inaccessible to those occult metastases due to an impermeable blood–tumor barrier (BTB). Phosphatidylserine (PS) is externalized on the surface of viable endothelial cells (ECs) in tumor blood vessels. In this study, we have applied a PS-targeting antibody to assess brain metastases in mouse models. Fluorescence microscopic imaging revealed that extensive PS exposure was found exclusively on vascular ECs of brain metastases. The highly sensitive and specific binding of the PS antibody enables individual metastases, even micrometastases containing an intact BTB, to be clearly delineated. Furthermore, the conjugation of the PS antibody with a fluorescence dye, IRDye 800CW, or a radioisotope, 125I, allowed the clear visualization of individual brain metastases by optical imaging and autoradiography, respectively. In conclusion, we demonstrated a novel strategy for targeting brain metastases based on our finding that abundant PS exposure occurs on blood vessels of brain metastases but not on normal brain, which may be useful for the development of imaging and targeted therapeutics for brain metastases.

Oncology↗

Absorption technique for OH measurements and calibration

An absorption technique is described which utilizes a stabilized frequency-doubled tunable dye laser and a long-path White cell with high mirror reflectivities both in the red and UV. In laboratory conditions it has been possible to routinely obtain a detection sensitivity of 3 parts in 1,000,000 over absorption paths less than 1 m in length and a detection sensitivity of approximately 6 parts in 100,000 over an absorption path of the order of 1 km. The latter number corresponds to 3,000,000 OH molecules/cu cm, and therefore the technique should be particularly useful for calibration the fluorescence instrument for OH measurements. However, the presence of atmospheric fluctuations coupled with intensity variation accompanying frequency scanning appears to degrade the detection sensitivity in outdoor ambient conditions, thus making it unlikely that this technique can be employed for direct OH monitoring.

Bakalyar, D. M.↗

A new water-based scintillator for efficient Cherenkov and scintillation separation

Neutrinos offer a unique window into the world around us, allowing us to probe otherwise unreachable regions like the interior of stars and the depths of the earth, as well as potentially offering a mechanism for monitoring nuclear activity. Both pure-water and organic liquid scintillators have been used as the detection medium of large-scale neutrino detectors. Organic liquid scintillators offer higher sensitivity at lower energies, which is desirable for many applications, but detection of the Cherenkov radiation required for directional sensitivity is very difficult. A possible solution is to use water-based liquid scintillators (WbLSs), where some fraction of the water is replaced with a micellar solution of the liquid scintillator. This can enhance the detection sensitivity beyond that of pure water, without significantly affecting the ability to leverage the topological Cherenkov signature. Very specific scintillation properties are required to achieve this goal: the scintillation decay time should be significantly slower than that of the Cherenkov emission, so timing-based discrimination of Cherenkov light from scintillation can be applied. At the same time, the light yield should be high enough to enhance the overall sensitivity of the detector, but without losing too much of the Cherenkov light. In this study, we report a new water-based liquid scintillation cocktail based on a 9-methylcarbazole fluorescent dye and a linear alkylbenzene solvent. Here, the proposed composition offers 13.8 ns scintillation decay time and 368 nm emission that matches the desired properties.

Wolszczak, Weronika W. [Lawrence Berkeley National↗

Intracavity Dye-Laser Absorption Spectroscopy (IDLAS) for application to planetary molecules

Time-resolved, quasi-continuous wave, intracavity dye-laser absorption spectroscopy is applied to the investigation of absolute absorption coefficients for vibrational-rotational overtone bands of water at visible wavelengths. Emphasis is placed on critical factors affecting detection sensitivity and data analysis. Typical generation-time dependent absorption spectra are given.

Lang, Todd M.↗

Nonintrusive, multipoint velocity measurements in high-pressure combustion flows

A combined experimental and analytical effort was conducted to demonstrate the applicability of OH Doppler-shifted fluorescence imaging of velocity distributions in supersonic combustion gases. The experiments were conducted in the underexpanded exhaust flow from a 6.8 atm, 2400 K, H2-O2-N2 burner exhausting into the atmosphere. In order to quantify the effects of in-plane variations of the gas thermodynamic properties on the measurement accuracy, a set of detailed measurements of the OH (1,0) band collisional broadening and shifting in H2-air gases was produced. The effect of pulse-to-pulse variations in the dye laser bandshape was also examined in detail and a modification was developed which increased in the single pulse bandwidth, thereby increasing the intraimage velocity dynamic range as well as reducing the sensitivity of the velocity measurement to the gas property variations. Single point and imaging measurements of the velocity field in the exhaust flowfield were compared with 2D, finite-rate kinetics simulations of the flowfield. Relative velocity accuracies of +/- 50 m/s out of 1600 m/s were achieved in time-averaged imaging measurements of the flow over an order of magnitude variation in pressure and a factor of two variation in temperature.

Allen, M.↗

Third-generation FAGE instrument for tropospheric hydroxyl radical measurement

A single-stage, frequency-doubled, copper vapor laser-pumped dye laser has been constructed to be used in the measurement of atmospheric hydroxyl radical concentrations. A new photon counting instrument is used for HO fluorescence detection. Theoretical and experimental studies of instrument performance show better sensitivities and reduced photolytic interferences than have been possible with previous systems based upon Nd:YAG pumping.

Chan, C. Y.↗

Production and Evaluation of Fluorophore-Doped Polymer Substrates to Screen for Plastic-Degrading Enzymes

Fast and sensitive analytical methods are the key to efficient screening of plastic-degrading enzymes. Here, we present a streamlined and affordable approach to assess the enzymatic deconstruction of insoluble synthetic polymers by blending them with a fluorescent dye, rhodamine 6G, and we evaluate this screening method using poly(ethylene terephthalate) (PET) as a model material. Our results indicate that enzymatic depolymerization of the rhodamine-doped PET can be observed in a high-throughput fashion by following release of the fluorophore. The fluorescence data obtained during the hydrolysis of rhodamine-doped PET by 14 PET hydrolases, produced with a robotic platform, correlated with the quantitative chromatographic analysis of PET degradation products. Remarkably, the use of the rhodamine-loaded PET substrate resulted in negligibly low background signals even when detecting PETase activity in crude cell lysates, suggesting suitability for screening of a wide variety of samples. Encouraged by these results, we next produced a selection of polyethylene- and nylon-based materials loaded with rhodamine 6G. While rapid leaching of fluorophore observed with nylon substrates limits the utility of the method for detecting nylonase activity, the rhodamine-loaded polyethylene showed promising performance in passive diffusion tests, indicating that this latter substrate may be used to screen for polyolefin-degrading enzymes.

09 BIOMASS FUELS↗

New algae mapping technique by the use of an airborne laser fluorosensor.

An airborne laser fluorosensor for the detection of algae in the sea has been developed. The system transmits dye laser radiation at 590 nm and monitors the fluorescent emission at 685 nm from chlorophyll-a bearing microorganisms. The system was successfully flown over the test areas of Lake Ontario and Chesapeake Bay. The device is sensitive to a fraction of mg/cu-M chlorophyll-a density in the water from an altitude of 30 m.

Kim, H. H.↗

Atomic Force Microscope Mediated Chromatography

The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a sliding plate system, consisting of two flat surfaces, one of which has a recessed channel. A fluid flow is produced by axially sliding one plate past another, where the fluid has mechanical shear forces imposed at each point along the channel length. The shear-induced flow rates are very reproducible, and do not have pressure or voltage gradient limitations. SDC opens up a new range of enhanced separation kinetics by permitting the sample confinement with submicron dimensions. Small, highly confined liquid is advantageous for chromatographic separation because the separation rate is known to scale according to the square of the confined sample diameter. In addition, because shear-driven flows are not limited by fluid velocity, shear-driven liquid chromatography may provide up to 100,000 plate efficiency.

Anderson, Mark S.↗

Ordered organic thin films self-assembled from the vapor phase

Organic films self-assembled from a liquid phase, as in Langmuir-Blodgett or adsorption from solution, have received much attention in the past decade as techniques to achieve highly oriented-ordered polymeric thin films. Many organic compounds including some of the same fatty acids have been vapor deposited as well. However, organic pigments and dyes comprise a major class of important materials which have very low solubilities yet excellent thermal stabilities, making them ideally suited for film deposition from the vapor phase. Surprisingly, such molecular systems exhibit a significant propensity to self order, a high sensitivity to deposition parameters, and a range of microstructural forms that cannot be duplicated by the less energetic mechanisms associated with solution adsorption processes. Molecular solids such as heterocyclic polynuclear aromatics are excellent candidates for film formation by vacuum deposition means. Over the past decade, our work and that of others investigating a wide variety of perylene and phthalocyanine derivatives identified five deposition parameters that can significantly affect film morphology, physical microstructure, and type and extent of ordering developed in vacuum and vapor transport grown films. These parameters are substrate temperature, deposition rate, substrate chemistry and epitaxy, ambient gas convective flows, and post deposition annealing. Examples of how each of these conditions manifest themselves in the film structure and ordering, most frequently revealed by scanning electron microscopy, reflection absorption infrared spectroscopy (RAIR), and grazing incidence x-ray diffraction (GIX), are presented.

Debe, M. K.↗

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Surface and Flow Field Measurements on the FAITH Hill Model

A series of experimental tests, using both qualitative and quantitative techniques, were conducted to characterize both surface and off-surface flow characteristics of an axisymmetric, modified-cosine-shaped, wall-mounted hill named "FAITH" (Fundamental Aero Investigates The Hill). Two separate models were employed: a 6" high, 18" base diameter machined aluminum model that was used for wind tunnel tests and a smaller scale (2" high, 6" base diameter) sintered nylon version that was used in the water channel facility. Wind tunnel and water channel tests were conducted at mean test section speeds of 165 fps (Reynolds Number based on height = 500,000) and 0.1 fps (Reynolds Number of 1000), respectively. The ratio of model height to boundary later height was approximately 3 for both tests. Qualitative techniques that were employed to characterize the complex flow included surface oil flow visualization for the wind tunnel tests, and dye injection for the water channel tests. Quantitative techniques that were employed to characterize the flow included Cobra Probe to determine point-wise steady and unsteady 3D velocities, Particle Image Velocimetry (PIV) to determine 3D velocities and turbulence statistics along specified planes, Pressure Sensitive Paint (PSP) to determine mean surface pressures, and Fringe Imaging Skin Friction (FISF) to determine surface skin friction (magnitude and direction). This initial report summarizes the experimental set-up, techniques used, data acquired and describes some details of the dataset that is being constructed for use by other researchers, especially the CFD community. Subsequent reports will discuss the data and their interpretation in more detail

Bell, James H.↗

Experimental Resonance Enhanced Multiphoton Ionization (REMPI) studies of small molecules

Resonance enhanced multiphoton ionization (REMPI) utilizes tunable dye lasers to ionize an atom or molecule by first preparing an excited state by multiphoton absorption and then ionizing that state before it can decay. This process is highly selective with respect to both the initial and resonant intermediate states of the target, and it can be extremely sensitive. In addition, the products of the REMPI process can be detected as needed by analyzing the resulting electrons, ions, fluorescence, or by additional REMPI. This points to a number of exciting opportunities for both basic and applied science. On the applied side, REMPI has great potential as an ultrasensitive, highly selective detector for trace, reactive, or transient species. On the basic side, REMPI affords an unprecedented means of exploring excited state physics and chemistry at the quantum-state-specific level. An overview of current studies of excited molecular states is given to illustrate the principles and prospects of REMPI.

Dehmer, J. L.↗

Remote water quality measurements with a lidar polarimeter

A lidar polarimeter system utilizing a 5 mw He-Ne laser has been constructed and used for laboratory and day light backscatter measurements from suspensions of teflon particles and absorbing dye in water. The results of this study have shown that a lidar polarimeter system can measure 'volume reflectance' without interference of peripheral effects such as sky reflections. The polarization ratio appears to be less affected by surface waves than does the total intensity or individual polarizations. The cross polarized return is the most sensitive to changes in the single scatter albedo and absolute concentrations of absorbing and scattering materials. A criterion is indicated which states that finite beam effects must be considered when the total extinction length is greater than the incident beam width.

Wilhelmi, G. J.↗

Absolute determination of local tropospheric OH concentrations

Long path absorption (LPA) according to Lambert Beer's law is a method to determine absolute concentrations of trace gases such as tropospheric OH. We have developed a LPA instrument which is based on a rapid tuning of the light source which is a frequency doubled dye laser. The laser is tuned across two or three OH absorption features around 308 nm with a scanning speed of 0.07 cm(exp -1)/microsecond and a repetition rate of 1.3 kHz. This high scanning speed greatly reduces the fluctuation of the light intensity caused by the atmosphere. To obtain the required high sensitivity the laser output power is additionally made constant and stabilized by an electro-optical modulator. The present sensitivity is of the order of a few times 10(exp 5) OH per cm(exp 3) for an acquisition time of a minute and an absorption path length of only 1200 meters so that a folding of the optical path in a multireflection cell was possible leading to a lateral dimension of the cell of a few meters. This allows local measurements to be made. Tropospheric measurements have been carried out in 1991 resulting in the determination of OH diurnal variation at specific days in late summer. Comparison with model calculations have been made. Interferences are mainly due to SO2 absorption. The problem of OH self generation in the multireflection cell is of minor extent. This could be shown by using different experimental methods. The minimum-maximum signal to noise ratio is about 8 x 10(exp -4) for a single scan. Due to the small size of the absorption cell the realization of an open air laboratory is possible in which by use of an additional UV light source or by additional fluxes of trace gases the chemistry can be changed under controlled conditions allowing kinetic studies of tropospheric photochemistry to be made in open air.

Armerding, Wolfgang↗