Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops & bubbles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microgravity Combustion Science and Fluid Physics Experiments and Facilities for the ISS

At the NASA Glenn Research Center, the Microgravity Science Program supports both ground-based and flight experiment research in the disciplines of Combustion Science and Fluid Physics. Combustion Science research includes the areas of gas jet diffusion flames, laminar flames, burning of droplets and misting fuels, solids and materials flammability, fire and fire suppressants, turbulent combustion, reaction kinetics, materials synthesis, and other combustion systems. The Fluid Physics discipline includes the areas of complex fluids (colloids, gels, foams, magneto-rheological fluids, non-Newtonian fluids, suspensions, granular materials), dynamics and instabilities (bubble and drop dynamics, magneto/electrohydrodynamics, electrochemical transport, geophysical flows), interfacial phenomena (wetting, capillarity, contact line hydrodynamics), and multiphase flows and phase changes (boiling and condensation, heat transfer, flow instabilities). A specialized International Space Station (ISS) facility that provides sophisticated research capabilities for these disciplines is the Fluids and Combustion Facility (FCF). The FCF consists of the Combustion Integrated Rack (CIR), the Fluids Integrated Rack (FIR) and the Shared Accommodations Rack and is designed to accomplish a large number of science investigations over the life of the ISS. The modular, multiuser facility is designed to optimize the science return within the available resources of on-orbit power, uplink/downlink capacity, crew time, upmass/downmass, volume, etc. A suite of diagnostics capabilities, with emphasis on optical techniques, will be provided to complement the capabilities of the subsystem multiuser or principal investigator-specific experiment modules. The paper will discuss the systems concept, technical capabilities, functionality, and the initial science investigations in each discipline.

Lauver, Richard W.↗

Marangoni Effects on the Bubble Dynamics in a Pressure Driven Flow

The motion of air bubbles and water drops in a Hele-Shaw cell filled with a silicone oil has been studied experimentally and theoretically. By adding a predetermined amount of a surfactant to the water drops we attempted to investigate the surfactant influence systematically. While the motion of air bubbles was in reasonable agreement with the predictions of Taylor and Saffman, water drops behaved quite differently in that the translational velocities were smaller by an order of magnitude and their shapes were very unusual as observed previously by Kopf-Sill and Homsy. Assuming that the surrounding fluid wets the solid wall and the bubble (or the drop) surface is rigid due to the surfactant influence, we have estimated the translational velocity of an elliptic bubble. The calculated velocities were in good agreement with the observations indicating that the surfactant influence could retard the bubble motion significantly. The present study also indicates that the unusual bubble shapes are also due to the surfactant influence.

Park, Chang-Won↗

Dynamics of free drops on USML-1

Drop-dynamics experiments are described in terms of scope and methodology that are designed for the USML-1 flight. Included are experiments regarding: (1) the equilibrium shapes of acoustically rotated drops; (2) large-amplitude drop and bubble-shape oscillations; (3) the collision and coalescence of free drops; and (4) the deformation and instability of levitated drops. The space flight is concluded to provide an effective containerless microgravity environment for studying linear and nonlinear dynamics.

Wang, Taylor G.↗

The geophysical importance of bubbles in the sea

Present knowledge of the mechanisms for production and enrichment and film drops by bursting bubbles is summarized, with particular emphasis on the unsolved problems. Sea salt is by far the major constituent cycled through the Earth's atmosphere each year. Bursting bubbles in the oceans appear to be primarily responsible. These salt particles play a role in the formation of maritime clouds, which in turn affect the Earth's radiation budget. Along with the salt are carried various chemical pollutants and potentially pathogenic microorganisms, often in highly enriched form.

Cirpriano, R. J.↗

Surface characterization through shape oscillations of drops in microgravity and 1-g

The goal of these experiments is to determine the rheological properties of liquid drops of single or multiple components in the presence or absence of surface active materials by exciting drops into their quadrupole resonance and observing their free decay. The resulting data coupled with appropriate theory should give a better description of the physics of the underlying phenomena, providing a better foundation than earlier empirical results could. The space environment makes an idealized geometry available (spherical drops) so that theory and experiment can be properly compared, and allows a 'clean' environment, by which is meant an environment in which no solid surfaces come in contact with the drops during the test period. Moreover, by considering the oscillations of intentionally deformed drops in microgravity, a baseline is established for interpreting surface characterization experiments done on the ground by other groups and ours. Experiments performed on the United States Microgravity Laboratory Laboratory (USML-1) demonstrated that shape oscillation experiments could be performed over a wide parameter range, and with a variety of surfactant materials. Results, however, were compromised by an unexpected, slow drop tumbling, some problems with droplet injection, and the presence of bubbles in the drop samples. Nevertheless, initial data suggests that the space environment will be useful in providing baseline data that can serve to validate theory and permit quantitative materials characterization at 1-g.

Apfel, Robert E.↗

Method of forming frozen spheres in a force-free drop tower

Hollow glass spheres are shaped by the effects of surface tension acting on bubbles of glass in its molten state. A downwardly flowing stream of air accelerated at a one-G rate of acceleration is established through a drop bubbles on molten glass are introduced into the stream of air and frozen and as they are accelerated at a one-G rate of acceleration.

Kendall, J. M., Jr.↗

Measurement of the Shear Lift Force on a Bubble in a Channel Flow

Two-phase flow systems play vital roles in the design of some current and anticipated space applications of two-phase systems which include: thermal management systems, transfer line flow in cryogenic storage, space nuclear power facilities, design and operation of thermal bus, life support systems, propulsion systems, In Situ Resource Utilization (ISRU), and space processes for pharmaceutical applications. The design of two-phase flow systems for space applications requires a clear knowledge of the behaviors of the dispersed phase (bubble), its interaction with the continuous phase (liquid) and its effect on heat and mass transfer processes, The need to understand the bubble generation process arises from the fact that for all space applications, the size and distribution of bubbles are extremely crucial for heat and mass transfer control. One important force in two-phase flow systems is the lift force on a bubble or particle in a liquid shear flow. The shear lift is usually overwhelmed by buoyancy in normal gravity, but it becomes an important force in reduced gravity. Since the liquid flow is usually sheared because of the confining wall, the trajectories of bubbles and particles injected into the liquid flow are affected by the shear lift in reduced gravity. A series of experiments are performed to investigate the lift force on a bubble in a liquid shear flow and its effect on the detachment of a bubble from a wall under low gravity conditions. Experiments are executed in a Poiseuille flow in a channel. An air-water system is used in these experiments that are performed in the 2.2 second drop tower. A bubble is injected into the shear flow from a small injector and the shear lift is measured while the bubble is held stationary relative to the fluid. The trajectory of the bubble prior, during and after its detachment from the injector is investigated. The measured shear lift force is calculated from the trajectory of the bubble at the detachment point. These values for the shear lift are then compared with the theoretical predictions from various published works on shear lift in the open literature, which include asymptotic solutions at low bubble Reynolds number, potential flow predictions and numerical studies that deal with intermediate bubble Reynolds numbers.

Nahra, Henry K.↗

Liquid Oxygen Liquid Acquisition Device Bubble Point Tests with High Pressure LOX at Elevated Temperatures

When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122K) as part of NASA s continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

Jurns, John M.↗

Numerical Modeling of Liquid-Vapor Phase Change

We implemented a two- and three-dimensional finite difference/front tracking technique to solve liquid-vapor phase change problems. The mathematical and the numerical features of the method were explained in great detail in our previous reports, Briefly, we used a single formula representation which incorporated jump conditions into the governing equations. The interfacial terms were distributed as singular terms using delta functions so that the governing equations would be the same as conventional conservation equations away from the interface and in the vicinity of the interface they would provide correct jump conditions. We used a fixed staggered grid to discretize these equations and an unstructured grid to explicitly track the front. While in two dimensions the front was simply a connection of small line segments, in three dimensions it was represented by a connection of small triangular elements. The equations were written in conservative forms and during the course of computations we used regriding to control the size of the elements of the unstructured grid. Moreover, we implemented a coalescence in two dimensions which allowed the merging of different fronts or two segments of the same front when they were sufficiently close. We used our code to study thermocapillary migration of bubbles, burst of bubbles at a free surface, buoyancy-driven interactions of bubbles, evaporation of drops, rapid evaporation of an interface, planar solidification of an undercooled melt, dendritic solidification, and a host of other problems cited in the reference.

Esmaeeli, Asghar↗

The migration of a compound drop due to thermocapillarity

The quasistatic thermocapillary motion of a compound drop in an unbounded fluid possessing a uniform temperature gradient is analyzed. For completeness, gravitational effects are included in the treatment. The general model is formulated, and the equations for the concentric case are solved using spherical polar coordinates, while the eccentric case is handled using bispherical coordinates. Results are given for the velocity of the drop as well as that of the droplet with respect to the drop, along with useful approximations. Illustrative results are presented graphically for the thermocapillary migration of a compound drop in the special case when the droplet is a gas bubble. In addition to the velocities of the drop and the bubble, representative isotherms and streamlines also are presented which display interesting qualitative features.

Morton, David S.↗

Studies of Two-Phase Gas-Liquid Flow in Microgravity

Two-phase gas-liquid flows are expected to occur in many future space operations. Due to a lack of buoyancy in the microgravity environment, two-phase flows are known to behave differently than those in earth gravity. Despite these concerns, little research has been conducted on microgravity two-phase flow and the current understanding is poor. This dissertation describes an experimental and modeling study of the characteristics of two-phase flows in microgravity. An experiment was operated onboard NASA aircraft capable of producing short periods of microgravity. In addition to high speed photographs of the flows, electronic measurements of void fraction, liquid film thickness, bubble and wave velocity, pressure drop and wall shear stress were made for a wide range of liquid and gas flow rates. The effects of liquid viscosity, surface tension and tube diameter on the behavior of these flows were also assessed. From the data collected, maps showing the occurrence of various flow patterns as a function of gas and liquid flow rates were constructed. Earth gravity two-phase flow models were compared to the results of the microgravity experiments and in some cases modified. Models were developed to predict the transitions on the flow pattern maps. Three flow patterns, bubble, slug and annular flow, were observed in microgravity. These patterns were found to occur in distinct regions of the gas-liquid flow rate parameter space. The effect of liquid viscosity, surface tension and tube diameter on the location of the boundaries of these regions was small. Void fraction and Weber number transition criteria both produced reasonable transition models. Void fraction and bubble velocity for bubble and slug flows were found to be well described by the Drift-Flux model used to describe such flows in earth gravity. Pressure drop modeling by the homogeneous flow model was inconclusive for bubble and slug flows. Annular flows were found to be complex systems of ring-like waves and a substrate film. Pressure drop was best fitted with the Lockhart- Martinelli model. Force balances suggest that droplet entrainment may be a large component of the total pressure drop.

Bousman, William Scott↗

Water Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently scheduled for March, 2009, after which the pump will be delivered to NASA for further testing.

Schuller, Michael↗

Custom Unit Pump Design and Testing for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.

Schuller, Michael↗

Custom Unit Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, seal-less, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion, and restart capability under both ambient and vacuum conditions. The pump operated at 40 to 240 lbm/hr flow rate, 35 to 100 oF pump temperature, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test.

Schuller, Michael↗

Hydrodynamics of Two-Phase Flows through Porous Media in Microgravity: Packed Bed Reactor Experiment onboard of the International Space Station

The objective of the Packed Bed Reactor Experiment was to develop a fundamental understanding of the hydrodynamics of two-phase flow with no phase transition through porous media in microgravity. This work describes two experimental campaigns flown on the International Space Station (ISS) that were designed to achieve the objective. This work presents the results on flow patterns observed, two-phase flow pressure drop in porous media, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work is the first to present predictive correlations of the two-phase friction factor for the different regimes identified based on the superficial liquid and gas velocity in microgravity, the first to hypothesize the different regimes based on the change in slope of the pressure gradient versus flow rate plots, the first to address the effects of the capillarity on the pressure gradient and the first to measure column holdup and assess the effective porosity based on the packing and the trapped gas bubbles. Experimental data on pressure drop in gas (N2) – liquid (water) flow show the presence of four different flow regimes in microgravity. Dispersed bubble flow (DB) and pulse (P) flow regimes are detected at high liquid flow rates, whereas at low liquid flow rates “large bubble” or elongated bubble (LB) and “gas channeling” (GC) regimes are observed. For these different flow regimes, different two-phase flow friction factor and pressure gradient correlations are presented for the first time as a function of the gas and liquid modified Reynolds numbers and Suratman number. Within the viscous-capillary (V-C) regime, it is found that the capillary contribution is the dominant force that contributes to the pressure drop for the wetting case (glass). However, for the non-wetting packing (Teflon), the viscous contribution dominates. It was found that the gas hold-up and pressure drop are functions of bed history at low liquid and gas flow rates with the magnitude of the hysteresis decreasing with increasing flow rates. PBRE-2 results show that the capillary force is a strong function of the superficial liquid velocity but is a much weaker function of the superficial gas velocity and varies inversely with the particle diameter. Within the Viscous-Capillary (V-C) regime, over 90% of the pressure gradient is attributed to the capillary contribution in the gas continuous regime. However, in the large bubble regime, the viscous and capillary contributions were comparable. After the completion of PBRE-2 with glass spherical beads, another bed packed with alumina was installed. Pressure gradient data for the alumina packed bed (PBRE-Water Recovery) were transferred to the PI and were not analyzed by the authors of this work. The Packed Bed Reactor Experiment concluded its on-orbit operation after two successful campaigns of testing in 2017 and in 2021. The flight hardware was brought back from orbit and is being reconditioned for a series of future experiments referred to as PBRE-WRS in support of water recovery (WRS). The WRS series consists of testing different two-phase fluid system components and packed beds to assess their pressure gradient characteristics, which will be used for designing packed bed reactors for various applications relevant to life support. Although there is so much relevance of the experimental results obtained from the two PBRE campaign in microgravity to life support, these findings also apply to other applications that involve two phase flow in porous medium such as fuel cells, transport of nutrient to plants in space and other chemical and materials processing that involve two phase flows. These systems operate differently in microgravity because, due to the lack of buoyancy, the density difference between the phases becomes irrelevant and no longer leads to phase separation.

Packed Bed↗

Bubble and Slug Flow at Microgravity Conditions: State of Knowledge and Open Questions

Based on the experiments carried out over the past decade at microgravity conditions, an overview of our current knowledge of bubbly and slug flows is presented. The transition from bubble to slug flow, the void fraction and the pressure drop are discussed from the data collected in the literature. The transition from bubble to slug flow may be predicted by introducing a critical void fraction that depends on the fluid properties and the pipe diameter; however, the role of coalescence which controls this transition is not clearly understood. The void fraction may be accurately calculated using a drift-flux model. It is shown from local measurements that the drift of the gas with respect to the mixture is due to non-uniform radial distribution of void fraction. The pressure drop happens to be controlled by the liquid flow for bubbly flow whereas for slug flow the experimental results show that pressure drops is larger than expected. From this study, the guidelines for future research in microgravity are given.

Colin, C.↗

Ultrasonic simulation of MSBLS multipath fading for orbiter landing configuration

The on-shuttle antenna pattern of the MSBLS receiver, and the azimuth and elevation beamwidths were simulated by their corresponding ultrasonic transducer beams. The scanning rate for the azimuth and elevation beams was 1.75 degrees/second. The results were adjusted for full-scale maximum sinusoidal scan rates of 691 and 377 deg/sec for AZ and EL respectively. The rain drops were simulated by air bubbles, with a similar size distribution, in water. The rain volume was created along a part of the propagation path, and not on the runway, because it was found difficult to avoid an accumulation of bubbles on the runway surface and surroundings simulated by the model surface. Multipath fading from the ground, and its possible degrading effect on the orbiter received beam shape and the associated landing guidance parameters is discussed.

Hayre, H. S.↗