Engineering PapersSearch

SEARCH · Engineering Papers

Results for “double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Tomographic Location of Potential Melt-Bearing Phenocrysts in Lunar Glass Spherules

In 1971, Apollo 17 astronauts collected a 10 cm soil sample (74220) comprised almost entirely of orange glass spherules. Below this, a double drive-tube core sampled a 68 cm thick horizon comprised of orange glass and black beads (crystallized equivalents of orange glass). Primitive lunar glass spherules (e.g.-A17 orange glasses) are thought to represent ejecta from lunar mare fire fountains [1, 2]. The fire-fountains were apparently driven by a combination of C-O gas ex-solution from orange glass melt and the oxidation of graphite [3, 4]. Upon eruption, magmas lost their volatiles (e.g., S, CO, CO2) to space. Evidence for volatile escape remains as volatile-rich coatings on the exteriors of many spherules [e.g., 5,6]. Moreover, [7] showed that Type I and II Fe-Ni-rich metal particles found within orange glass olivine phenocrysts, or free-floating in the glass itself, are powerful evidence for the volatile driving force for lunar fire fountains.

Ebel, D. S.

Separation and Sealing of a Sample Container Using Brazing

A special double-wall container and a process for utilizing the container are being developed to enable (1) acquisition of a sample of material in a dirty environment that may include a biological and/or chemical hazard; (2) sealing a lid onto the inner part of the container to hermetically enclose the sample; (3) separating the resulting hermetic container from the dirty environment; and (4) bringing that hermetic container, without any biological or chemical contamination of its outer surface, into a clean environment. The process is denoted S(exp 3)B (separation, seaming, and sealing using brazing) because sealing of the sample into the hermetic container, separating the container from the dirty environment, and bringing the container with a clean outer surface into the clean environment are all accomplished simultaneously with a brazing operation.

Bar-Cohen, Yoseph

Double window viewing chamber assembly

A viewing chamber which permits observation of a sample retained therein includes a pair of double window assemblies mounted in opposed openings in the walls thereof so that a light beam can directly enter and exit from the chamber. A flexible mounting arrangement for the outer windows of the window assemblies enables the windows to be brought into proper alignment. An electrical heating arrangement prevents fogging of the outer windows whereas desiccated air in the volume between the outer and inner windows prevents fogging of the latter.

Keller, V. W.

Micro and macro approaches to tough polymers for composites

The progress to date on the development of techniques to toughen continuous thermoplastic composites is summarized. The work, using the approach of toughening the polycarbonate composite matrix with rubber particles, has focused on determining the differences between Double Cantilever Beam (DCB) samples molded inhouse and those molded by NASA. Specifically, an effort was made to account for the differences in fracture toughness observed between the various specimens. In addition, preliminary results of tensile dilatometry tests are described; these tests suggest that processes leading to increased volume and enhanced shear banding are occurring within the rubber toughened system. The results of the effort using another approach, the preparation of random block copolycarbonates, are presented. The synthetic route to these species was modified so that higher molecular weights of these materials can be obtained. In addition, an attempt is being made to determine the exact block length or the number of functional groups in the oligomers since this procedure also should lead to high molecular weight materials. Dynamic mechanical analysis of the copolymer prepared so far indicates that the scale of cooperative molecular motion of the PBA polycarbonate at sub-Tg temperatures is larger than five monomer units. Efforts to find a suitable rubber-toughener for a thermoset system (bismaleimides) is also discussed. Included is a description of the various tougheners intended for use or currently being used.

Yee, Albert F.

Electronic Still Camera

A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.

Holland, S. Douglas

Pharmacodynamics of Promethazine in Human Subjects

Promethazine (PMZ) is the drug of choice for the treatment of symptoms associated with space motion sickness in astronauts. Side effects of PMZ include sedation, dizziness and cognitive performance impairment. In this study, we examined pharmacodynamics (PD) in human subjects and validated methods for evaluating cognitive performance effects of medications in space. METHODS: PMZ (12.5,25, and 50 mg) or placebo was administered by IM injection to human subjects in a randomized double-blind treatment design. Samples and data were collected for 72 h post dose. PD evaluation was performed using a battery of performance tests administered using WinSCAT (Windows based Space Cognitive Assessment Test) on a laptop computer, and ARES (ANAM Readiness Evaluation System) on a PDA, plasma concentrations of PMZ were measured using a LC-MS method. RESULTS: Results indicate a linear correlation between PMZ concentration and cognitive performance parameters (p<0.01). Test accuracy decreased and test completion time and response time increased significantly with increasing plasma PMZ concentration. CONCLUSIONS: These results suggest a concentration dependent decrement in cognitive performance associated with PMZ. WinSCAT and ARES are sensitive tools for the assessment PMZ PD and may be applicable for such evaluations with other neurocognitive drugs.

Gatlin, K. T.

Characterizing the GD-1 Stream with DESI DR2 Data: Thin Stream and Hot Cocoon

GD-1 is among the longest, coldest stellar streams in the Milky Way, making it an ideal target for probing dark matter substructure through dynamical heating. We present a catalog of 608 spectroscopically confirmed GD-1 members from the first three years of Dark Energy Spectroscopic Instrument (DESI) observations. This constitutes the largest homogeneous spectroscopic sample of GD-1, doubling the number of members previously available only through heterogeneous compilations combining multiple surveys with different systematics. Using these data, we derive updated stream tracks in sky position, proper motion, and radial velocity that extend over $100^\circ$ of the stream. We apply a Gaussian mixture model to decompose the stream into a dynamically cold thin component ($σ_V = 2.49\pm 0.28$ km s$^{-1}$, width $= 0.23\pm0.01^\circ$) and a kinematically hot cocoon ($σ_V = 6.13\pm0.75$ km s$^{-1}$, width $= 2.18\pm0.17^\circ$). The cocoon contains $\sim30\%$ of members and its velocity dispersion is consistent with $\sim11$ Gyr of heating by cold dark matter subhalos. We also detect a large proper motion dispersion ($41.36\pm4.98$ km s$^{-1}$) along the stream direction in the cocoon component. This feature indicates a significant line-of-sight distance spread in the cocoon, and its origin will be further explored in a forthcoming paper. These measurements demonstrate the power of DESI spectroscopy for characterizing the multi-component phase-space structure of stellar streams and constraining small-scale dark matter substructure.

Jarvis, Emma [Toronto U.] (ORCID:0009000656127336)

Synchronous Separation, Seaming, Sealing and Sterilization (S4) using Brazing for Sample Containerization and Planetary Protection

The potential return of samples back to Earth from other planetary bodies would be based on planetary protection requirements that vary depending on the type of body [1]. Potential Mars Sample Return would require the protection of our planet from backward contamination. To fulfill this requirement, it would be necessary to implement “break the chain of contact (BTC)” process, where any material reaching Earth would have to be inside a container that is sealed with an extremely high level of confidence. In order to accomplish this, it would be necessary to contain the acquired samples and destroy any potential biological materials that may have contaminated the external surface of the container, while protecting the samples for further analysis. Using brazing, a novel synchronous separation, seaming, sealing and sterilization (S4) process for sample containerization and planetary protection has been conceived and demonstrated. A prototype double-wall container with inner and outer shells and Earth clean interstitial space was used for this demonstration. For potential Mars sample return, the double wall container would be consist of two halves and prepared on Earth. The on-orbit execution would consist of inserting the sample into one of the halves and then mating to the other half and melt the braze material to perform the S4 process. The use of brazing material that melts at temperatures higher than 500OC would assure sterilization of the exposed areas due to pyrolysis since carbon bonds are broken at this temperature. The process consists of two-steps, Step-1: the double wall container halves are fabricated and brazed on Earth; and Step-2: Assembly and brazing the samples on orbit. To prevent potential jamming during the process of mating the two halves of the double-wall container and the extraction of the brazed inner container, a double cone-within-cone approach has been conceived. The results of this study are described and discussed in this manuscript.

Bar-Cohen, Yoseph

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.

Stratigraphy of the Apollo 17 Landslide Core 73002 From FMR Maturity and VNIR and Mössbauer Spectroscopy

A suite of samples from the Apollo missions to the Moon (1969-1973) were set aside and stored under controlled conditions to have unexamined lunar samples available decades later for analyses that take advantage of evolved sample handling techniques, maturation of then existing instrumentation, and development of new analytical techniques and instrumentation [e.g., 1]. One preserved sample is the Apollo 17 double drive tube core (73001/2) that was driven into the lunar surface on the landslide deposit at Station 3 on the South Massif in the Taurus-Littrow valley [2]. The deeper section (73001) was stored frozen in a Core Sample Vacuum Container (CSVC) to maximize preservation of lunar volatiles. We report here, as a part of the Apollo Next Generation Sample Analysis (ANGSA) Initiative [1,3], stratigraphy for the upper core section (73002) with respect to maturity (ferromagnetic resonance (FMR) maturity index Is/FeO [4-6]), visible-near-IR (VNIR) spectroscopy, and, for representative samples, grain-size analysis and Mössbauer spectroscopy. Stratigraphy provides data to model the dynamics of lunar landslide deposits and their post-emplacement evolution in comparison to impact-driven mixing on an airless body and stratigraphic context for volatile and (if any) organic behavior. Reported by [7] are preliminary results for multispectral imaging and hyperspectral scanning of the first dissection pass of 73002.

R. V. Morris

Mechanistic Insights Into Fatigue Life Enhancement of High‐Strength Steel via Ultrasonic Impact Treatment

In this work we explore the impact of Ultrasonic Impact Treatment (UIT) on the fatigue performance of high‐strength microalloyed steel commonly used in crankshaft applications. Building on prior observations of fatigue life improvement with UIT, this work focuses on unraveling the process–structure–performance relationships underpinning these enhancements. Microstructural analysis revealed significant grain refinement in the near‐surface layers, with deformation depth increasing at higher impact energies. This led to increased surface hardness and the development of deeper compressive residual stresses, particularly in samples treated with higher impact energy. Rotating bending fatigue testing showed a substantial improvement in fatigue life for UIT‐treated samples, with the endurance limit nearly doubling compared with untreated specimens. Fractographic analysis revealed a transition in crack initiation from surface defects in untreated samples to interior regions in UIT‐treated samples, characterized by the formation of noninclusion‐induced granular bright facets (GBFs). The observed fatigue enhancement is attributed to the synergistic effects of strain hardening and compressive residual stresses, which increase the surface crack threshold and promote interior crack initiation. This study provides new mechanistic insight into UIT‐induced fatigue resistance and interior failure behavior in high‐strength steels.

36 MATERIALS SCIENCE

Ulysses observations of double ion beams associated with coronal mass ejections

Coronal mass ejections (CME's) are thought to result from the loss of stability within a magnetically confined coronal structure leading to its radial expansion into interplanetary space. As the CME expands into the corona current sheets will form between the expanding CME and surrounding field lines in the ambient wind. This configuration may lead to reconnection between the CME and adjacemt field lines. Such reconnection may produce double ion beams as has been observed in the terrrestrial magnetosphere. We examine all 24 distinct signatures of CME's observed by Ulysses during the in-ecliptic portion of the mission. In 5 of these 24 cases the ion spectra were not clear and thus the presence of double ion beams could not be determined. In 13 of the remaining 19 CME's double ion beams were found on the leading and/or trailing edge of the CME but not in the interior of the CME. In 3 of the CME's double ion beams were found throughout the CME while in the remaining 3 CME's double ion beams were not present near or just inside of the CME. In contrast in a control sample of 19 randomly chosen intervals, double ion beams were present at the leading and/or trailing edges of the random intervals in only 3 of the 19 cases. There appears to be no correlation between probability of occurrence of double ion beams and a magnetic cloud or non-cloud configuration of the CME and no correlation between the presence of the double ion beams at the edges of the CME and the CME being a fast or slow CME.

Hammond, C. M.

Luminosity Function of Quasars at 1.0 < z < 3.5 from SDSS and DESI

We present a study of the evolution of type 1 quasars at 1.0 < z < 3.5, covering the peak epoch of quasar activity. The quasar evolution has been extensively explored by a variety of previous works and the derived quasar luminosity functions (QLFs) are not very consistent with each other, presumably due to the complexities introduced by different quasar selection techniques and associated completeness corrections. We use a new strategy to construct QLFs based on a library of all known quasars. We focus on a wide region of ∼1700 deg 2 and a deep field of ∼265 deg 2 that have rich spectroscopic data primarily from the Sloan Digital Sky Survey and DESI. We then apply traditional color cuts in the rest-frame UV–optical to select quasar candidates and use the quasar library to identify them. Our final sample consists of 62,426 quasars at 1.0 < z < 3.5, with a high completeness (∼96%) and a high purity (∼93%) in the color selection. Simple color cuts can potentially minimize selection biases for the study of quasar evolution. We derive binned QLFs and characterize them using a double power-law model. Sample incompleteness and contamination are considered as part of the uncertainties in the calculation. Compared to previous results, our QLFs are slightly higher at the faint end, and also higher at the bright end at 2.5 < z < 3.5. The QLFs suggest that the quasar evolution at 1.0 < z < 2.5 can be well described by the pure luminosity evolution model, while at 2.5 < z < 3.5, it can be described by either the pure luminosity evolution or the pure density evolution model.

Luminosity function

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)

Explosion Welding for Hermetic Containerization

A container designed for storing samples of hazardous material features a double wall, part of which is sacrificed during an explosion-welding process in which the container is sealed and transferred to a clean environment. The major advantage of this container sealing process is that once the samples have been sealed inside, the outer wall of what remains of the container is a clean surface that has not come into contact with the environment from which the samples were taken. Thus, there is no need to devise a decontamination process capable of mitigating all hazards that might be posed by unanticipated radioactive, chemical, and/or biological contamination of the outside of the container. The container sealing method was originally intended to be used to return samples from Mars to Earth, but it could also be used to store samples of hazardous materials, without the need to decontaminate its outer surface. The process stages are shown. In its initial double-wall form, the volume between the walls is isolated from the environment; in other words, the outer wall (which is later sacrificed) initially serves to protect the inner container from contamination. The sample is placed inside the container through an opening at one end, then the container is placed into a transfer dock/lid. The surfaces that will be welded together under the explosive have been coated with a soft metallic sacrificial layer. During the explosion, the sacrificial layer is ejected, and the container walls are welded together, creating a strong metallic seal. The inner container is released during the same event and enters the clean environment.

Dolgin, Benjamin

Analysis of Volatile Organic Compounds in the Apollo Next Generation Sample Analysis (ANGSA) 73002 Core Sample

Understanding the organic content of lunar regolith was an early priority upon the return of Apollo samples, with amino acids being of special interest because of their importance to life on Earth and their astrobiological relevance. Many initial studies focused on the detection of amino acids in these samples and attempts to determine the origin of those compounds. Although no consensus on the origin of the amino acids was reached in those early studies, more recent work determined that the detected amino acids originated from both terrestrial contamination and meteoritic or cometary in fall to the lunar surface. A majority of the amino acids in the Apollo samples studied originated from precursor molecules, either indigenous to the lunar samples or contaminants, that reacted during the water extraction and acid hydrolysis process for analysis in the laboratory, but the identities of the amino acid precursors still remain poorly understood. Such precursors could include hydrogen cyanide (HCN) and other volatile organic compounds such as amines, carboxylic acids, or aldehydes and ketones. The identities of these compounds, as well as the effects of years of curation on their abundances in lunar regolith samples stored at ambient temperature under nitrogen gas purge, are not clear. The specially curated samples available through the Apollo Next Generation Sample Analysis (ANGSA) program provide a unique opportunity to use state-of- the-art analytical techniques to examine previously unstudied lunar materials. The ANGSA samples include three types of samples: 1) samples stored frozen since <1 month after Earth arrival; 2) samples stored under helium; and 3) a double drive tube collected by Apollo 17 astronauts, with the bottom portion of the drive tube sealed under vacuum on the Moon and never opened. In contrast to the typically curated Apollo samples that have been kept for decades at room temperature under flowing nitrogen purge that may have significantly reduced the abundance of volatiles, the vacuum-sealed and frozen samples may have enhanced preservation of these volatiles. Our initial investigation examines amino acids and their potential volatile precursors, including hydrogen cyanide (HCN), aldehydes, ketones, amines, and mono-carboxylic acids, in a sample from the top portion of the Apollo 17 double drive tube. These results will aid in understanding the lunar abundances of these molecules and will also be compared to future analyses of other drive tube and frozen ANGSA samples.

Elsila, J. E.

DESI2024: Dark Energy Spectroscopic Instrument (DESI) survey, presentation of Year 1 results

The series of papers included in this special issue represent the first cosmological measurements from the Dark Energy Spectroscopic Instrument (DESI). These papers present the validation of the DESI clustering catalogs, the methodology for the cosmology measurements, and the full cosmology implications. These measurements were derived from a catalog of approximately 6.4 million extragalactic sources in a redshift range of 0.1 < z < 4.2. Owing to advances in fiber positioner technology and to a larger telescope, this sample was acquired in only one year of observation, yet is more than double the size of the galaxy and quasar samples from the first four phases of the Sloan Digital Sky Survey (SDSS) that spanned 20 years. With these new galaxy and quasar catalogs, the DESI collaboration completed percent-level constraints on the cosmic expansion history and the growth of structure. In turn, these new measurements provided a new platform from which to test the equation of state of dark energy, the summed mass of the three neutrino mass eigenstates, global curvature, and General Relativity. By surpassing the precision of the previous generation spectroscopic survey, the results in this special issue mark the transition in the field of cosmology to Stage-IV dark energy science.

baryon acoustic oscillations

Carotenoid diagenesis in a marine sediment

The major carotenoids at three levels (3, 40, and 175 m below the sediment-water interface) in a core from a marine sediment (Cariaco Trench, off Venezuela) have been examined. Mass and electronic spectral data have provided evidence for the onset of a progressive reduction of carotenoids in the geological column. The time scale of the process appears to depend on the particular carotenoid. Reduction of up to two double bonds is observed for the diol, zeaxanthin, in the oldest sediment (about 340,000 years old) but no reduction is observed in the younger samples (about 5000 and 56,000 years old). The diketone, canthaxanthin, shows evidence of reduction of up to two double bonds in the 56,000-yr sample and up to five double bonds in the oldest sample. No reduction of beta-carotene was observed in any of the samples.

Watts, C. D.