Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “double pulse test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 30 GHz solid state amplifier for low cost low data rate ground terminals

This report details the development of a 20-W solid state amplifier operating near 30 GHz. The IMPATT amplifier not only met or exceeded all the program objectives, but also possesses the ability to operate in the pulse mode, which was not called for in the original contract requirements. The ability to operate in the pulse mode is essential for TDMA (Time Domain Multiple Access) operation. An output power of 20 W was achieved with a 1-dB instantaneous bandwidth of 260 MHz. The amplifier has also been tested in pulse mode with 50% duty for pulse lengths ranging from 200 ns to 2 micro s with 10 ns rise and fall times and no degradation in output power. This pulse mode operation was made possible by the development of a stable 12-diode power combiner/amplifier and a single-diode pulsed driver whose RF output power was switched on and off by having its bias current modulated via a fast-switching current pulse modulator. Essential to the overall amplifier development was the successful development of state-of-the-art silicon double-drift IMPATT diodes capable of reproducible 2.5 W CW output power with 12% dc-to-RF conversion efficiency. Output powers of as high as 2.75 W has been observed. Both the device and circuit design are amenable to low cost production.

Ngan, Y. C.↗

Chromosome Model reveals Dynamic Redistribution of DNA Damage into Nuclear Sub-domains

Several proteins involved in the response to DNA double strand breaks (DSB) form microscopically visible nuclear domains, or foci, after exposure to ionizing radiation. Radiation-induced foci (RIF) are believed to be located where DNA damage is induced. To test this assumption, we analyzed the spatial distribution of 53BP1, phosphorylated ATM and gammaH2AX RIF in cells irradiated with high linear energy transfer (LET) radiation. Since energy is randomly deposited along high-LET particle paths, RIF along these paths should also be randomly distributed. The probability to induce DSB can be derived from DNA fragment data measured experimentally by pulsed-field gel electrophoresis. We used this probability in Monte Carlo simulations to predict DSB locations in synthetic nuclei geometrically described by a complete set of human chromosomes, taking into account microscope optics from real experiments. As expected, simulations produced DNA-weighted random (Poisson) distributions. In contrast, the distributions of RIF obtained as early as 5 min after exposure to high LET (1 GeV/amu Fe) were non-random. This deviation from the expected DNA-weighted random pattern can be further characterized by relative DNA image measurements. This novel imaging approach shows that RIF were located preferentially at the interface between high and low DNA density regions, and were more frequent in regions with lower density DNA than predicted. This deviation from random behavior was more pronounced within the first 5 min following irradiation for phosphorylated ATM RIF, while gammaH2AX and 53BP1 RIF showed very pronounced deviation up to 30 min after exposure. These data suggest the existence of repair centers in mammalian epithelial cells. These centers would be nuclear sub-domains where DNA lesions would be collected for more efficient repair.

Costes, Sylvain V.↗

Wind Tunnel Testing of Active Flow Control on High-Lift Common Research Model

A 10%-scale high-lift version of the Common Research Model (CRM-HL) and an Active Flow Control (AFC) version of the model equipped with a simple-hinged flap (CRM-SHLAFC) were successfully tested. The tests were performed in the 14- by 22-Foot Subsonic Tunnel (14x22) at the NASA Langley Research Center (LaRC). The CRM-HL has a set of 37° inboard and outboard single-element Fowler flaps. The CRM-SHL-AFC has a set of 50° inboard and 55° outboard simple-hinged flaps equipped with integrated modular AFC cartridges on the flap shoulder. Both high-lift configurations share the same 30° slats and engine nacelle. Three new types of AFC devices were examined: the Double-Row Sweeping Jets (DRSWJ), the Alternating Pulsed Jets (APJ), and the High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used a combination of unsteady and steady jets, to overcome strong adverse pressure gradients while minimizing the mass flow usage. Nozzle pressure ratio, mass flow consumption and the power coefficient, which takes account of both supply air pressure and mass flow usage for the actuators, were used for judging the performance efficiency of the AFC devices. A prestall lift performance degradation for the CRM-HL configuration was resolved with a properly placed nacelle chine. The configuration with nacelle chine was chosen as the representative reference conventional high-lift case for comparison with the CRMSHL- AFC. The AFC-induced lift coefficient increment (DCL) was maintained for the entire lift curve over the CRM-SHL-AFC case with no AFC for almost all flow-control cases examined. The lift curve of the reference CRM-HL have a slightly steeper slope compared to those of the CRM-SHL-AFC configurations. The HELP actuation concept was extremely effective in controlling flow separation in the “linear region” of the curves comparing lift coefficient to mass flow rate. The HELP actuation achieved a targeted DCL of 0.50 using a moderate amount of mass flow and supply air pressure. The CRM-SHL-AFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional high-lift configuration (i.e., CRM-HL equipped with a nacelle chine), thus meeting the NASA Advanced Air Transport Technology (AATT) project goal.

Lin, John C.↗

Optimization of Picosecond Laser Parameters for Surface Treatment of Composites Using a Design of Experiments (DOE) Approach

Based on guidelines from the Federal Aviation Administration, research supported by the NASA Advanced Composites Project is investigating methods to improve process control for surface preparation and pre-bond surface characterization on aerospace composite structures. The overall goal is to identify high fidelity, rapid, and reproducible surface treatments and surface characterization methods to reduce the uncertainty associated with the bonding process. The desired outcome is a more reliable bonded airframe structure, and to reduce time to achieve certification. In this work, a design of experiments (DoE) approach was conducted to determine optimum laser ablation conditions using a pulsed laser source with a nominal pulse width of 10 picoseconds. The laser power, frequency, scan speed, and number of passes (1 or 2) were varied within the laser system operating boundaries. Aerospace structural carbon fiber reinforced composites (Torayca® 3900-2/T800H) were laser treated, then characterized for contamination, and finally bonded for mechanical testing. Pre-bond characterization included water contact angle (WCA) using a handheld device, ablation depth measurement using scanning electron microscopy (SEM), and silicone contamination measurement using laser induced breakdown spectroscopy (LIBS). In order to accommodate the large number of specimens in the DoE, a rapid-screening, double cantilever beam (DCB) test specimen configuration was devised based on modifications to ASTM D5528. Specimens were tested to assess the failure modes observed under the various laser surface treatment parameters. The models obtained from this DoE indicated that results were most sensitive to variation in the average laser power. Excellent bond performance was observed with nearly 100% cohesive failure for a wide range of laser parameters. Below about 200 mW, adhesive failure was observed because contamination was left on the surface. For laser powers greater than about 600 mW, large amounts of fiber were exposed, and the failure mode was predominately fiber tear.

Palmieri, Frank L.↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with various cathodes and anodes in a high power, quasi-steady magnetoplasmadynamic (MPD) are discussed. The magnitude of the current at the onset of voltage fluctuations is shown to be an increasing function of cathode area and a weaker decreasing function of anode area. Tests with a fluted cathode indicated that the fluctuations originate in the plasma adjacent to the cathode rather than at the cathode surface. Measurements of radiative output from an optical cavity aligned to examine the current-carrying portion of a two-dimensional, 56 kA magnetoplasmadynamic discharge reveal no lasing in that region, consistent with calculations of electron excitation and resonance radiation trapping. A voltage-swept double probe technique allows single-shot determination of electron temperature and electron number density in the recombining MPD exhaust flow. Current distributions within the cavity of MPD hollow cathodes for various static prefills with no injected mass flow are examined.

Jahn, R. G.↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Oxygen Spectroscopy Laser Sounding Instrument for Remote Sensing of Atmospheric Pressure

We report on the progress of an Oxygen spectroscopy laser sounding instrument designed as a calibration channel for a carbon dioxide (CO2) laser sounding instrument. We have developed a pulsed, frequency-doubled, fiber laser transmitter for use in an oxygen instrument. The instrument concept uses the pressure broadening of spectroscopic lines of the diatomic oxygen A-band to deduce atmospheric pressure. There are many uses for this measurement but we are developing it primarily to make a measurement of the dry mixing ratio of CO2. The CO2 measurement can be affected by changes in atmospheric properties such as humidity, temperature and pressure. To remove these variances requires measuring a stable, well-mixed gas like Oxygen. We will report on the basic theory behind the instrument, measurements made at a test site at Goddard, review the current state of the instrument technologies and the necessary steps to bring them to space readiness, and review the current state of the instrument development.

Stephen Mark A.↗

NIAC Phase-2 Final Report for Astrophysics and Technical Lab Studies of a Solar Neutrino Spacecraft Detector

The Sun provides all the energy that our planet needs for life and has been doing so for five billion years. Understanding our Sun and its interior is one of the major goals of the NASA Science program. Still this is a very difficult task because very little makes it directly out of the Sun’s interior. The energy we see today, that warms the Earth, was made 50,000 to 80,000 years ago and is only now coming to the surface to make light. However, neutrinos penetrate matter almost without interaction and make it to Earth in only eight minutes from creation. Since neutrinos interact only weakly they are hard to detect; never-the-less within the last ten years neutrino detectors on Earth have started to reliably detect neutrinos from the fusion reactions in the interior of the Sun and scientists have started to use this information to investigate the Sun’s nuclear furnace. Changes in solar neutrino flux make it advantageous to take a neutrino detector into space since the solar neutrino intensity changes dramatically as the inverse square of the distance from the Sun, by five orders of magnitude when going from the Earth to the Sun. Launch of a neutrino detector into space toward the Sun will: a) aim to significantly increase the neutrino flux 10,000x allowing for a smaller detector which improves detector energy resolution and performance, b) attempt to completely eliminate background terrestrial neutrino sources for improved measurement accuracy, and c) conduct unique science experiments near the Sun not achievable with much larger detectors on the Earth. NASA's interest in deep space exploration has been a key factor in its unmanned spacecraft development and launch of exploration science satellites and spacecraft. NASA has done exceptional experiments in space where science benefits from the unique platform of spacecraft that provides unprecedented views. For example, the Hubble Space Telescope is really a small and very common instrument, but when it is put into an orbit high above the Earth, it becomes one of the most powerful optical observatories man has ever made. Moving neutrino observations to space is the next obvious step. The concept of putting a neutrino detector in close orbit of the sun is completely unexplored and innovative. Its scientific return is to vastly enhance the understanding of the solar interior which is a NASA major goal as stated in the decadal survey. Preliminary calculations show that such a spacecraft if properly shielded, can operate in this environment both taking data of neutrino interactions which can be distinguished from random background rates of solar Electromagnetic emissions, Galactic charged cosmic-ray, and gamma-rays by using a double pulsed signature. The NIAC Phase-1 simulations have shown this idea to be very successful in eliminating background and identifying the neutrino interaction signal, hence this spacecraft detector concept once demonstrated to be Technical Readiness Level 7 and flight mission-ready would enable a whole new type of mission to explore and study our Sun, in details that could neither be done with the largest neutrino detectors on Earth nor other types of space-craft measurements that are not using neutrino detection. Our goal in this NIAC Phase-2 was to take the detector simulation ideas and construct a prototype for testing in the lab with tagged sources to evaluate and demonstrate that the performance in the simulations are borne out by a prototype.

Neutrino↗

Multiphoton ionization of N2 by the third harmonic of a Nd:YAG laser - A new avenue for air diagnostics

Laser-induced N2 ionization is accomplished using a commercially available Nd:YAG laser, and confirmed by means of ion-collection and spectral measurements. Neutral N2 is excited by six photons of the third harmonic frequency, or 355 nm, and is transformed to an ionized state. The radiation at 355 nm is separated from the fundamental and frequency-doubled Nd:YAG radiation to guarantee monochromatic incident radiation. Intense lines near 391.4 nm are found in the initial laser polarization and for a 90-degree rotation of polarization. The radiation at 391.4 nm is associated with an incoherent laser-induced flourescence process related to an ionized-state transition, and increases quadratically with laser power. A 45-mJ laser pulse focused to a diameter of 17 microns can produce an ion concentration of 3.25 x 10 to the 13th ions/cu cm. The large ion concentration and robust fluorescence signal make this technique an efficient method for time-of-flight velocimetry and in-flight testing.

Laufer, Gabriel↗

The 15 cm diameter ion thruster research

The startup reliability of a 15 cm diameter mercury bombardment ion thruster which employs a pulsed high voltage tickler electrode on the main and neutralizer cathodes is examined. Startup of the thruster is achieved 100% of the time on the main cathode and 98.7% of the time on the neutralizer cathode over a 3640 cycle test. The thruster was started from a 20 C initial condition and operated for an hour at a 600 mA beam current. An energy efficiency of 75% and a propellant utilization efficiency of 77% was achieved over the complete cycle. The effect of a single cusp magnetic field thruster length on its performance is discussed. Guidelines are formulated for the shaping of magnetic field lines in thrusters. A model describing double ion production in mercury discharges is presented. The production route is shown to occur through the single ionic ground state. Photographs of the interior of an operating-hollow cathode are presented. A cathode spot is shown to be present if the cathode is free of low work-function surfaces. The spot is observed if a low work-function oxide coating is applied to the cathode insert. Results show that low work-function oxide coatings tend to migrate during thruster operation.

Wilbur, P. J.↗

Performance Improvements to the Lidar Atmospheric Sensing Experiment (LASE)

Lidar Atmospheric Sensing Experiment (LASE) is the first fully-engineered, modular, tunable, autonomous Differential Absorption Lidar (DIAL) system for the remote measurement of water vapor, aerosols and clouds across the troposphere. It was designed, built and environmentally tested at LARC. LASE was designed to fly aboard a NASA/Ames ER-2 aircraft (NASA's high altitude aircraft) and operate at altitudes from 58,000 to 70,000 feet. Since its first flight on May 11, 1994, it has flown 28 total missions on board the ER-2. LASE has been validated with results showing an accuracy better than the initial requirement for vertical profiles of water vapor in the troposphere. LASE can also deploy on several other aircraft including the NASA P-3 and will fly aboard the NASA DC-8 during the Convection And Moisture EXperiment (CAMEX) in July-September 1998. The tunable laser system of LASE was designed to operate in a double-pulse mode at 5Hz, with energy outputs of up to 15OmJ per pulse in the 813 to 819nm wavelength region and with 99% of the output energy within a spectral interval of 1.06 pm. Sixteen wavelengths were selected to cover the various water vapor absorption cross sections needed for the DIAL measurement. The Ti:Sapphire laser was constructed using a frequency-doubled Nd:YAG laser as the pump source and a single mode diode laser as a injection seeder for the Ti:Al2O3 laser. We have improved the LASE instrument in several important ways. Improvements to the seed source have demonstrated that DFB laser diodes can be used as reliable seed sources on airborne DIAL instruments. The DFB diode has enabled LASE to gather more data and significantly reduced the maintenance required to insure that the system performance requirements are met. The multiwavelength sequential seeding technique is the current method of data collection for LASE. It has the advantages of providing an entire atmospheric coverage of H2O(v) from the ground to the aircraft altitude along a single ground track. The development of a flight deployable system to measure spectral purity will insure that the LASE instrument or any future flight based DIAL system can meet the performance specifications to insure data accuracy.

Edwards, W. C.↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Evaluation of a High Sensitivity DIAL System for Profiling Atmospheric CO2

A ground-based 2-micron Differential Absorption Lidar (DIAL) CO2 profiling system for atmospheric boundary layer studies and validation of space-based CO2 sensors is being developed and tested at NASA Langley Research Center as part of the NASA Instrument Incubator Program. To capture the variability of CO2 in the lower troposphere a precision of 1-2 ppm of CO2 (less than 0.5%) with 0.5 to 1 km vertical resolution from near surface to free troposphere (4-5 km) is one of the goals of this program. In addition, a 1% (3 ppm) absolute accuracy with a 1 km resolution over 0.5 km to free troposphere (4-5 km) is also a goal of the program. This DIAL system leverages 2-micron laser technology developed under NASA's Laser Risk Reduction Program (LRRP) and other NASA programs to develop new solid-state laser technology that provides high pulse energy, tunable, wavelength-stabilized, and double-pulsed lasers that are operable over pre-selected temperature insensitive strong CO2 absorption lines suitable for profiling of lower tropospheric CO2. It also incorporates new high quantum efficiency, high gain, and relatively low noise phototransistors, and a new receiver/signal processor system to achieve high precision DIAL measurements. This presentation describes the capabilities of this system for atmospheric CO2 and aerosol profiling. Examples of atmospheric measurements in the lidar and DIAL mode will be presented.

Ismail, Syed↗

A Joint NICER and XMM-Newton View of the "Magnificent" Thermally Emitting X-ray Isolated Neutron Star RX J1605.3+3249

Thermally emitting X-ray isolated neutron stars (NSs) represent excellent targets for testing cooling surface emission and atmosphere models, which are used to infer the physical parameters of the NS. Among the seven known members of this class, RXJ1605.3+3249 is the only one that still lacks confirmation of its spin period. Here we analyze NICER and XMM-Newton observations of RXJ1605.3+3249, in order to address its timing and spectral behavior. Contrary to a previous tentative detection, but in agreement with the recent work by Pires et al., we find no significant pulsation with a pulsed fraction higher than 1.3% (3σ) for periods above 150 ms. We also find a limit of 2.6% for periods above 2 ms, despite searches in different energy bands. The X-ray spectrum can be fit by either a double-blackbody model or by a single-temperature magnetized atmosphere model, both modified by a Gaussian absorption line at ∼0.44 keV. The origin of the absorption feature as a proton cyclotron line or as an atomic transition in the NS atmosphere is discussed. The predictions of the best-fit X-ray models extended to IR, optical, and UV bands, are compared with archival data. Our results are interpreted in the framework of a fallback disk scenario.

Christian Malacaria↗

Measurement, data analysis and prediction of pyrotechnic shock from pin-pullers and separation joints

To evaluate the potential for spacecraft damage caused by activation of pyrotechnic mechanisms, pyrotechnic shock tests were conducted on three configurations: pin-pullers on an orthogonal double Hopkinson bar arrangement, pin-pullers on a mock-up of the HALOE (Halogen Occultation Experiment) structure, and a section of separation joint on a single Hopkinson bar. Strains and accelerations were measured. The strains were converted to output stresses, forces and moments. Acceleration shock response spectra are presented for both acceleration- and force-time signals. The devices were attached to the Hopkinson bars with adaptors, which are typical of attachments used in practice. In order to predict the effect of the adaptors, finite element models of the adaptor-bar combinations were analyzed and results are presented with regard to grid size, time interval, and frequency range required to predict the response to pulses of 10 and 100 microsecond duration.

Evans, Maria J.↗

Phugoid characteristics of a YF-12 airplane with variable-geometry inlets obtained in flight tests at a Mach number of 2.9

Flight tests were conducted with the YF-12 airplane to examine the airplane's longitudinal characteristics at a Mach number of approximately 2.9. Phugoid oscillations as well as short period pulses were analyzed with the variable geometry engine inlets in the fixed and the automatic configurations. Stability and control derivatives for the velocity and altitude degrees of freedom and the standard short period derivatives were obtained. Inlet bypass door position was successfully used to represent the total inlet system, and the effect of the inlets on the velocity and altitude derivatives was determined. The phugoid mode of the basic airplane (fixed inlet configuration) had neutral damping, and the height mode was stable. With the addition of the inlets in the automatic configuration, the phugoid mode was slightly divergent and the height mode was divergent with a time to double amplitude of about 114 seconds. The results of the derivative estimation indicated that the change in the height mode characteristics was primarily the result of the change in the longitudinal force derivative with respect to velocity.

Powers, B. G.↗

Estimation of automobile-driver describing function from highway tests using the double steering wheel

The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.

Delp, P.↗