Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

U.S. Department of Energy Solar District Cup Collegiate Design Competition

The Solar District Cup is a multidisciplinary collegiate competition that challenges student teams to design and model standalone solar and solar-plus-storage systems for multiple buildings on a local electrical distribution network, such as a college campus, across a development, or in a district. Students learn cross-cutting skills that prepare them to become part of the next generation of the distributed energy workforce. Student teams act as renewable energy developers proposing to solar and solar-plus-storage system requests. Students, faculty, and prospective employers can benefit from knowing about this program and what students learn--either immediately as participants, mentors, or judges, or as potential employers of Solar District Cup alumni. RE+ is also one of our competition partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Verification and Validation of Performance with Dissemination of Best Practices in District Energy and CHP for Enhanced Resiliency, Energy Efficiency, and Cybersecurity

This report contains the results of the International District Energy Association’s work to analyze, validate, and verify performance data of existing district energy systems and identify industy best practices for the purpose of improving system reliability, resiliency, and efficiency, and to accellerate decarbonization. In addition to a technical evaluation of the surveyed systems and identification of a series of technical performance metrics, the report illustrates the accompanying operations and financial best practices employed by surveyed systems to fully serve their customer base. Additionally, the third chapter of the report describes the current landscape of cybersecurity threats and counteracting measures, and recommends a series of steps for effectively guarding highly networked district energy systems against cybersecurity attacks.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

LCOH Estimated from Existing Geothermal District Heating Systems in the U.S.

Levelized cost of heat for geothermal district heating systems in the US was calculated from reported construction and operation costs obtained from a literature review. These costs were inflation adjusted to 2016 dollars. To obtain geothermal district heating levelized cost of heat, capital costs were amortized over 30 years with an interest rate of 4%. These results suggest that the levelized cost of heat produced in these systems is on the order of $35,750 per gigawatt hr (thermal). Expressed in more common units, the levelized cost of geothermal district heat is $36/MWh (~$10.5/MMBtu). This cost is reflective of state-of-the-art systems at the time of installation and does not account for recent technology advances such as combine heating/cooling systems and storage systems.

15 GEOTHERMAL ENERGY↗

Quantifying the Mobility and Energy Benefits of Automated Mobility Districts Using Microscopic Traffic Simulation

This poster highlights a study quantifying the mobility and energy benefits of automated mobility districts (AMDs), with a focus on the district-scale implementation of advanced vehicle (AV) technologies, the benefits of an AV-shared-mobility service within a confined geographic region or district, and AMD models serving as 'special generators' in existing urban travel demand models. Through the study, leaders developed an AMD modeling and simulation toolkit.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing Fleet Operations in Automated Mobility Districts: Serving On-Demand Mobility with Automated Electric Shuttles

On-demand transportation services have seen a dramatic rise in the past decade, thanks to technology. Connected and automated vehicle (CAV) technology holds potential for a major transformation in the on-demand mobility services landscape.The timeline for fully automated vehicles (AVs) to reach the critical market share is still uncertain. In the short term, many cities in the United States and abroad are testing low-speed automated electric shuttles (AES) as a shared on-demand mobility service in geo-fenced regions. An automated mobility district (AMD) is a campus-sized implementation of connected/automated vehicle technology to realize the full benefits of a fully electric automated mobility service within a confined region or district. Building on this concept, an AMD toolkit is under development at the National Renewable Energy Laboratory (NREL) to inform a campus-or district-sized implementation in which automated electric shuttles (AES). This research extends the functionality of the AMD toolkit by developing a mathematical program to optimize the operations of an AES fleet in an on-demand service configuration.

25 ENERGY STORAGE↗

Modeling and Simulation of Automated Mobility Districts

Increasing interest and investment in connected, automated, and electric vehicles (CAEVs), and mobility-as-a-service (MaaS) concepts are paving the way for the next major shift in transportation through automated and shared mobility. The initial excitement towards rapid deployment and adoption of automated vehicles has subsided, and low-speed automated shuttles are emerging as a more pragmatic pathway for introducing automated mobility in geo-fenced districts. Such shuttles hold the promise to provide a viable alternative for serving short trips in urban districts with high travel densities. As interest in low-speed automated shuttle systems (to improve urban mobility) increases, the need for tools that can inform communities regarding benefits or dis-benefits of automated shuttle deployments is imminent. However, most of the existing transportation planning and simulation tools are not capable of handling emerging shared automated mobility options. This presentation provide the details of a microscopic simulation toolkit that can be used by cities and communities to plan for the deployment of low-speed automated shuttles systems, as well as other shared mobility options. Labeled as Automated Mobility District (AMD) modeling and simulation toolkit, the proposed decision support tool intends to help cities evaluate the mobility and sustainability impacts of deploying shared automated vehicles in geofenced regions.The AMD modeling and simulation task is funded through DOE's SMART Mobility Consortium. This presentation outlines the progress of the AMD modeling and simulation task in FY19, including case studies conducted in Greenville, SC, and Austin, TX.

47 OTHER INSTRUMENTATION↗

Automated Mobility Districts - A Conceptual Definition: Preprint

An automated mobility district (AMD) provides for the movement of people and goods within a district through the use of fleets of roboticized vehicles as the primary mobility system. The concept of an AMD has precursors deployed in a few places around the world, in which the circulation within a dense urban district, such as a business and residential center or a major activity center like an airport terminal complex is accomplished using a fully automated transport system(s).

ADVANCED PROPULSION SYSTEMS↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY↗

U.S. Geothermal District Heating Systems and Funding Data

This dataset contains detailed information on geothermal district heating (GDH) systems across the United States, including technical specifications, costs, energy usage, and funding sources. Data includes system details such as state, site, location, operational years, temperature, flow rate, capacity, energy use, load factor, costs (original, updated, and operational), funding sources, employment impact, and project status. Additionally included are contributions to GDH systems, including federal, state, and local grants, as well as loans from agencies such as USDA and USDOE. This dataset serves as a resource for analyzing the economic and technical landscape of geothermal district heating in the United States.

15 GEOTHERMAL ENERGY↗

Land quality, sustainable development and environmental degradation in agricultural districts: A computational approach based on entropy indexes

Land Degradation (LD) in socio-environmental systems negatively impacts sustainable development paths. This study proposes a framework to LD evaluation based on indicators of diversification in the spatial distribution of sensitive land. We hypothesize that conditions for spatial heterogeneity in a composite index of land sensitivity are more frequently associated to areas prone to LD than spatial homogeneity. Spatial heterogeneity is supposed to be associated with degraded areas that act as hotspots for future degradation processes. A diachronic analysis (1960–2010) was performed at the Italian agricultural district scale to identify environmental factors associated with spatial heterogeneity in the degree of land sensitivity to degradation based on the Environmentally Sensitive Area Index (ESAI). In 1960, diversification in the level of land sensitivity measured using two common indexes of entropy (Shannon's diversity and Pielou's evenness) increased significantly with the ESAI, indicating a high level of land sensitivity to degradation. In 2010, surface area classified as “critical” to LD was the highest in districts with diversification in the spatial distribution of ESAI values, confirming the hypothesis formulated above. Entropy indexes, based on observed alignment with the concept of LD, constitute a valuable base to inform mitigation strategies against desertification. - Highlights: • Spatial heterogeneity is supposed to be associated with degraded areas. • Entropy indexes can inform mitigation strategies against desertification. • Assessing spatial diversification in the degree of land sensitivity to degradation. • Mediterranean rural areas have an evident diversity in agricultural systems. • A diachronic analysis carried out at the Italian agricultural district scale.

54 ENVIRONMENTAL SCIENCES↗

Ground Source Geothermal District Heating and Cooling System

Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anthropogenic Markers in Alta Irrigation District Water Supply Wells

In July 2016, LLNL produced a report for the Kings River Watershed Coalition Authority (KRWCA) entitled “Groundwater Age and Nitrate Isotopic Composition in Alta Irrigation District Water Supply Wells” (Esser et al., 2016). That report summarized groundwater age and nitrate isotopic composition data produced by LLNL for Alta Irrigation District (AID) groundwater wells sampled by KRWCA in a pilot project to test the utility of advanced isotopic methods for constraining the timing and source of nitrate in groundwater at selected sites in the Kings River service area. One section of that report made recommendations for follow-on study. The first and strongest recommendation was to measure a wider suite of source tracers including co-contaminants such as herbicides, pesticides, pharmaceuticals, personal care products, and food constituents and additives. KRWCA followed up on this recommendation in Phase II of the pilot study by re-sampling the original set of wells and submitting the samples to a commercial laboratory for analysis of a limited range of co-contaminants (including pharmaceuticals, personal care products , and food constituents and additives, but not including herbicides or pesticides). They have asked that LLNL review and interpret these data in the context of previous LLNL analyses and to evaluate the utility of such co-contaminant analyses in providing additional constraints on the source of groundwater nitrate contamination in Alta Irrigation District water supply wells. The goal of the second phase of this pilot project is to evaluate the utility of co-contaminant occurrence for constraining nitrate source in groundwater at selected sites in the Kings River service area, with special reference to the use of such data in conjunction with advanced isotopic methods such as nitrate isotopic composition and groundwater age. Nitrate isotopic composition alone cannot distinguish nitrate derived from animal manure from nitrate derived from human septic waste. The presence or absence of agricultural chemicals (herbicides, pesticides, veterinary pharmaceuticals) or chemicals associated with people (human pharmaceuticals, artificial sweeteners) can help make this distinction. Co-contaminant analyses using multi-analyte LC-MS-MS protocols are now commercially available and reasonably priced. The feasibility and utility of the using co-contaminants for nitrate source attribution can be evaluated by 1) determining the degree to which co-contaminants occur in distinct and easily attributable groupings (e.g. agricultural chemicals vs personal care products and food additives); 2) determining the degree to which co-contaminant occurrence is consistent with nitrate isotopic composition and groundwater age (e.g. no co-contaminant occurrence in very old groundwater; co-contaminants consistent with animal manure or human septic waste occurring in groundwaters having nitrate isotopic composition also consistent with animal manure or human septic waste); and 3) determining the degree to which co-contaminants provide additional constraint on nitrate source over and beyond nitrate isotopic composition and groundwater age (e.g. distinguishing between animal manure and human septic waste).

58 GEOSCIENCES↗

DC Solar for All: Implementation Plan to Scale Low- and Moderate- Income Community Solar + Storage Resilience Hubs in the District of Columbia

This implementation plan discusses the District of Columbia's strategy to combine low-income community solar projects with resilience technologies. Through the technical and financial support offered by the Inclusive Shared Solar Initiative and building on extensive stakeholder engagement in LMI neighborhoods around the District, the District of Columbia team expects to reduce energy burdens for LMI residents, address barriers to and streamline SfA program enrollment, and support the development of innovative benefit delivery models, including a community solar-supported climate resilience center.

14 SOLAR ENERGY↗

San Xavier District Solar Energy Project for Administration Building and Education Center

The San Xavier District of the Tohono O’odham Nation (District) developed grid-tied solar photovoltaic (PV) systems for two tribal buildings: the San Xavier District Administration Building and Education Center. For the Administration Building, an approximately 182-kilowatt (kW) solar PV system is projected to produce roughly 310,000 kilowatt-hours (kWh) per year and displace about 80% of the energy use of the building. For the Education Center, an approximately 73.5-kw system is projected to produce roughly 130,000 kWh per year and displace about 95% of the building’s energy use. The anticipated 25-year cost savings from the combined 255-kW systems are estimated to be approximately $1,750,000 and $820,000 for the Administration Building and the Education Center, respectively.

14 SOLAR ENERGY↗

Field performance of a district central ground source heat pump system in the US

This case study discusses the field performance of a district central ground source heat pump (GSHP) system installed at Ball State University (BSU) in Muncie, IN., USA. This district GSHP system replaces the existing central steam plant and water-cooled chiller plants and designed to serve 47 major buildings in BSU. The field performance of the GSHP system was analyzed based on measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. It was compared with the performance of a baseline scenario- a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. This paper presents the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district central GSHP system.

Im, Piljae↗