Machine Learning-Based Prediction of Distribution Network Voltage and Sensor Allocation

Increasing penetration of fast-varying energy resources may negatively affect power systems' operation. At the same time, sensor deployment throughout distribution networks improves system awareness and enables the development of new and advanced voltage control solutions. Such control techniques rely on accurate prediction in anticipation to voltage violation scenarios. This paper analyzes various approaches for voltage prediction in a distribution system; it is shown that combining multiple techniques into a single regressor improves its predictive power. Moreover, a two-step regressor is proposed, where initial predictions based on a global regressor are refined by local regressors; in this case, prediction errors decrease significantly. Additionally, a clustering approach is employed for performing sensor allocation, so that only the most influential buses are selected for monitoring without diminishing prediction accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Architecture for Co-Simulation of Transportation and Distribution Systems with Electric Vehicle Charging at Scale in the San Francisco Bay Area

This work describes the Grid-Enhanced, Mobility-Integrated Network Infrastructures for Extreme Fast Charging (GEMINI) architecture for the co-simulation of distribution and transportation systems to evaluate EV charging impacts on electric distribution systems of a large metropolitan area and the surrounding rural regions with high fidelity. The current co-simulation is applied to Oakland and Alameda, California, and in future work will be extended to the full San Francisco Bay Area. It uses the HELICS co-simulation framework to enable parallel instances of vetted grid and transportation software programs to interact at every model timestep, allowing high-fidelity simulations at a large scale. This enables not only the impacts of electrified transportation systems across a larger interconnected collection of distribution feeders to be evaluated, but also the feedbacks between the two systems, such as through control systems, to be captured and compared. The findings are that with moderate passenger EV adoption rates, inverter controls combined with some distribution system hardware upgrades can maintain grid voltages within ANSI C.84 range A limits of 0.95 to 1.05 p.u. without smart charging. However, EV charging control may be required for higher levels of charging or to reduce grid upgrades, and this will be explored in future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Bilevel Voltage Regulation Operation for Distribution Systems With Self-Operated Microgrids

The emerging of microgrids in distribution systems has significantly enhanced the resilience of power grids. However, the operators of a distribution system and microgrids therein can be different and have accessibility to different devices. To model the operation of such a grid, this work proposes a bilevel formulation and probes into the voltage regulation operation, considering the interaction between different systems. The proposed bilevel formulation considers the cooperation of active energy resources (AER), transformer tap-changers, and capacitor banks that are controlled by different operators. To facilitate the solution time of the target bilevel optimization, the lower-level problems with different objectives are modeled using deep neural networks (DNNs) which are then converted into a set of constraints. Hence, the bilevel problem can be reformed to a single-level problem. Lastly, the proposed solution procedures are validated using a customized joint system constructed by the IEEE 123-bus system and a real distribution system in Iowa. According to the numerical validation results, the solution time of the proposed nonlinear activation function based DNN model is 69 times faster than other methods in solving voltage regulation with a bilevel structure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities

Increased penetration levels of distributed variable renewable generation can cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But because of the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network are needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69-node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time-series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ripple-Type Control for Enhancing Resilience of Networked Physical Systems: Preprint

Distributed control agents have been advocated as an effective means for improving the resiliency of our physical in-frastructures under unexpected events. While purely local control has been shown to be insufficient, centralized optimal resource allocation approaches can be slow. In this context, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physicalsystem and are allowed to communicate with peers over a 'hot-line' communication network. According to this protocol, agents act upon on local readings unless their control resources have been depleted, in which case they send a beacon for assistance to peer agents. Our ripple-type scheme triggers communication locally only for the agents with saturated resources, and is proved to converge. Moreover, under a monotonicity assumption on the underlying physical law coupling control outputs to inputs, the devised control is proved to converge to a configuration satisfying safe operational constraints. The assumption is shown to hold for voltage control in electric power systems and pressure control in water distribution networks. Numerical tests on both networks corroborate the efficacy of the novel scheme.

distributed control↗

Adaptive Control of Distributed Energy Resources for Distribution Grid Voltage Stability

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. Here we provide a derivation of the adaptive control approach and validate the algorithm in experiments on the IEEE 37 and 8500 node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ripple-Type Control for Enhancing Resilience of Networked Physical Systems

Distributed control agents have been advocated as an effective means for improving the resiliency of our physical infrastructures under unexpected events. Purely local control has been shown to be insufficient, centralized optimal resource allocation approaches can be slow. In this context, we put forth a hybrid low-communication saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a “hotline” communication network. According to this protocol, agents act on local readings unless their control resources have been depleted, in which case they send a beacon for assistance to peer agents. Our ripple-type scheme triggers communication locally only for the agents with saturated resources and it is proved to converge. Moreover, under a monotonicity assumption on the underlying physical law coupling control outputs to inputs, the devised control is proved to converge to a configuration satisfying safe operational constraints. The assumption is shown to hold for voltage control in electric power systems and pressure control in water distribution networks. Numerical tests corroborate the efficacy of the novel scheme.

distributed control↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Voltage Regulation Performance Evaluation of Distributed Energy Resource Management via Advanced Hardware-in-the-Loop Simulation

This paper evaluates the performance of coordinated control across advanced distribution management systems (ADMS), distributed energy resources (DERs), and distributed energy resource management systems (DERMS) using an advanced hardware-in-the-loop (HIL) platform. This platform provides a realistic laboratory testing environment, including accurate dynamic modeling of a real-world distribution system from a utility partner, real controllers (ADMS and DERMS), physical power hardware (DERs), and standard communications protocols. One grid service—voltage regulation—is evaluated to show the performance of the coordinated grid automation system. The testing results demonstrate that the coordinated DERMS and ADMS system can effectively regulate system voltages within target operation limits using DERs. The realistic laboratory HIL testing results give utilities confidence in adopting the grid automation systems to manage DERs to achieve system-level control and operation objectives (e.g., voltage regulation). This helps utilities mitigate potential risks (e.g., instability) prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MPC-Based Local Voltage Control Strategy of DGs in Active Distribution Networks

The increasing penetration of distributed generators (DGs) exacerbates the voltage violations in active distribution networks (ADNs). The commonly used centralized voltage control may aggravate the burden of computation and communication. Local voltage control can realize fast response to frequent voltage fluctuations. However, effective local control for DGs still needs to be further investigated. In this paper, a model predictive control (MPC)-based local voltage control strategy of DGs is proposed to cope with voltage violation problems and enhance the adaptation to the DG volatility. DGs are regulated with local Q-V control curves to respond to voltage fluctuations rapidly. Based on the dynamic network partition, a unified control curve for DGs is set in the same area to realize efficient operation. To further improve the performance of voltage control, the parameter tuning of control curves is regularly conducted based on decentralized inter-area coordination with the rolling of the control horizon. Finally, case study is verified on the modified IEEE 33-node distribution system. The proposed local control strategy of DGs can effectively improve the voltage profile and reduce power losses of the whole network without high computation and communication burden.

active distribution network (ADN)↗