Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed PV forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Integrated Approach to Ancillary PV Component Reliability Assessment (Final Report)

In this project, we have established a nondestructive, generalized methodology that (1) fuses rich field data with advanced ML for proactive reliability forecasting, (2) dramatically reduces experimental iterations via synthetic dataset generation, and (3) achieves unprecedented regression precision in both anomaly detection and component-level degradation assessment—paving the way for truly predictive maintenance of grid-tied PV inverters under diverse outdoor conditions.

14 SOLAR ENERGY↗

Probabilistic Solar Power Forecasting Using Bayesian Model Averaging

There is rising interest in probabilistic forecasting to mitigate risks from solar power uncertainty, but the numerical weather prediction (NWP) ensembles readily available to system operators are often biased and underdispersed. We propose a Bayesian model averaging (BMA) post-processing method suitable for forecasting power from utility-scale photovoltaic (PV) plants at multiple time horizons up to at least the day-ahead timescale. BMA is a kernel dressing technique for NWP ensembles in which the forecast is a weighted sum of member-specific probability density functions. We tailor BMA for utility-scale PV forecasting by modeling power clipping at the AC inverter rating and advance the theory of BMA with a new beta kernel parameterization that accommodates theoretical constraints not previously addressed. BMA is demonstrated for a case study of 11 utility-scale PV plants in Texas, forecasting at hourly resolution for the complete year 2018. BMA's mixture-model approach mitigates underdispersion of the raw ensemble to significantly improve forecast calibration, while consistently outperforming an ensemble model output statistics (EMOS) parametric approach from the literature. At 4-hour lead time, the BMA post-processing achieves continuous ranked probability skill scores of 2--36% over the raw ensemble, with consistent performance at multiple lead times suitable for power system operations.

14 SOLAR ENERGY↗

Ensemble Solar Forecasting Statistical Quantification and Sensitivity Analysis: Preprint

Uncertainties associated with solar forecasts present challenges to maintain grid reliability, especially at high solar penetrations. This study aims to quantify the errors associated with the day-ahead solar forecast parameters and the theoretical solar power output for a 51-kW solar power plant in a utility area in the state of Vermont, U.S. Forecasts were generated by three numerical weather prediction (NWP) models, including the Rapid Refresh, the High Resolution Rapid Refresh, and the North American Model, and a machine-learning ensemble model. A photovoltaic (PV) performance model was adopted to calculate theoretical solar power generation using the forecast parameters (e.g., irradiance, cell temperature, and wind speed). Errors of the power outputs were quantified using statistical moments and a suite of metrics, such as the normalized root mean squared error (NRMSE). In addition, the PV model's sensitivity to different forecast parameters was quantified and analyzed. Results showed that the ensemble model yielded forecasts in all parameters with the smallest NRMSE. The NRMSE of solar irradiance forecasts of the ensemble NWP model was reduced by 28.10% compared to the best of the three NWP models. Further, the sensitivity analysis indicated that the errors of the forecasted cell temperature attributed only approximately 0.12% to the NRMSE of the power output as opposed to 7.44% from the forecasted solar irradiance.

14 SOLAR ENERGY↗

Ensemble Solar Forecasting Statistical Quantification and Sensitivity Analysis

Uncertainties associated with solar forecasts present challenges to maintain grid reliability, especially at high solar penetrations. This study aims to quantify the errors associated with the day-ahead solar forecast parameters and the theoretical solar power output for a 51-kW solar power plant in a utility area in the state of Vermont, U.S. Forecasts were generated by three numerical weather prediction (NWP) models, including the Rapid Refresh, the High Resolution Rapid Refresh, and the North American Model, and a machine-learning ensemble model. A photovoltaic (PV) performance model was adopted to calculate theoretical solar power generation using the forecast parameters (e.g., irradiance, cell temperature, and wind speed). Errors of the power outputs were quantified using statistical moments and a suite of metrics, such as the normalized root mean squared error (NRMSE). In addition, the PV model's sensitivity to different forecast parameters was quantified and analyzed. Results showed that the ensemble model yielded forecasts in all parameters with the smallest NRMSE. The NRMSE of solar irradiance forecasts of the ensemble NWP model was reduced by 28.10% compared to the best of the three NWP models. Further, the sensitivity analysis indicated that the errors of the forecasted cell temperature attributed only approximately 0.12% to the NRMSE of the power output as opposed to 7.44% from the forecasted solar irradiance.

14 SOLAR ENERGY↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Distributionally Robust Decentralized Volt-Var Control With Network Reconfiguration

Here, this paper presents a decentralized volt-var optimization (VVO) and network reconfiguration strategy to address the challenges arising from the growing integration of distributed energy resources, particularly photovoltaic (PV) generation units, in active distribution networks. To reconcile control measures with different time resolutions and empower local control centers to handle intermittency locally, the proposed approach leverages a two-stage distributionally robust optimization; decisions on slow-responding control measures and set points that link neighboring subnetworks are made in advance while considering all plausible distributions of uncertain PV outputs. We present a decomposition algorithm with an acceleration scheme for solving the proposed model. Numerical experiments on the IEEE 123 bus distribution system are given to demonstrate its outstanding out-of-sample performance and computational efficiency, which suggests that the proposed method can effectively localize uncertainty via risk-informed proactive timely decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategies for microgrid operation under real-world conditions

Microgrids are an increasingly relevant technology for integrating renewable energy sources into electricity systems. Based on a microgrid implementation in California, in this study we investigate microgrid operation under real-world conditions. These conditions have not yet been considered in combination and encompass energy charges, demand charges, export limits, as well as uncertainty about future electricity demand and generation in the microgrid. Under these conditions, we evaluate the performance of two frequently applied groups of strategies for microgrid operation. The first group is composed of proactive strategies that optimize decisions based on forecasts of future electricity generation and demand. The second group includes reactive strategies that make operational decisions based exclusively on the current state of the microgrid. We evaluate the performance of the strategies under varying operational parameters, forecast accuracies, and microgrid configurations—well beyond our Californian showcase. Our results confirm the expectation that proactive strategies outperform reactive ones in the majority of settings. Yet, reactive strategies can perform better under short control intervals or under moderate prediction errors of PV generation or demand. Furthermore, the interplay between real-world conditions and operational strategies reveals several additional insights for research on microgrid operation. First, we find that demand charges and export limits decisively affect microgrid performance. Second, the impact of forecast errors is highly non-linear and non-monotonous. Third, escalating negative interactions between forecast errors and demand charges make proactive strategies benefit from longer control intervals. This result is contrary to existing best practice, which promotes short control intervals to minimize the impact of uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Bidding Curve Design for Hybrid Power Plants with Uncertain Solar Forecast: Preprint

This paper presents a novel bidding curve design algorithm tailored for hybrid power plants (HPPs) to participate in the wholesale electricity market. Utilizing forecasts for photovoltaic (PV) generation and available battery power, our algorithm strategically computes the bidding curve to maximize HPP profit while adeptly managing the inherent uncertainty associated with PV power generation. In addition, the introduction of the penalty cost in HPP bidding curves provides the system operator a tool to effectively manage the system-level uncertainty that caused by HPPs. Numerical analysis through Monte Carlo simulations confirms that our bidding curve methodology outperforms the benchmark across various scenarios.

bidding curve↗

DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the converters combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.

14 SOLAR ENERGY↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications: Second Edition

As the world looks for low-carbon sources of energy, solar power stands out as the single most abundant energy resource on Earth. Harnessing this energy is the challenge for this century. Photovoltaics, solar heating and cooling, and concentrating solar power (CSP) are primary forms of energy applications using sunlight. These solar energy systems use different technologies, collect different fractions of the solar resource, and have different siting requirements and production capabilities. Reliable information about the solar resource is required for every solar energy application. This holds true for small installations on a rooftop as well as for large solar power plants; however, solar resource information is of particular interest for large installations, because they require substantial investment, sometimes exceeding 1 billion dollars in construction costs. Before such a project is undertaken, the best possible information about the quality and reliability of the fuel source must be made available. That is, project developers need reliable data about the solar resource available at specific locations, including historic trends with seasonal, daily, hourly, and (preferably) subhourly variability to predict the daily and annual performance of a proposed power plant. Without this data, an accurate financial analysis is not possible. Additionally, with the deployment of large amounts of distributed photovoltaics, there is an urgent need to integrate this source of generation to ensure the reliability and stability of the grid. Forecasting generation from the various sources will allow for larger penetrations of these generation sources because utilities and system operators can then ensure stable grid operations. Developed by the foremost experts in the field who have come together under the umbrella of the International Energy Agency's Solar Heating and Cooling Task 46, this handbook summarizes state-of-the-art information about all the above topics.

14 SOLAR ENERGY↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Momentum power spectrum of SDSS galaxies by massE cosmic ruler: 2.1×improvement in measure of growth rate

ABSTRACT Peculiar motion of galaxies probes the structure growth in the universe. In this study, we employ the galaxy stellar mass-binding energy (massE) relation with only two nuisance parameters to build the largest peculiar-velocity (PV) catalogue to date, consisting of 229 890 ellipticals from the main galaxy sample (MGS) of the Sloan Digital Sky Survey (SDSS). We quantify the distribution of the massE-based distances in individual narrow redshift bins (dz = 0.005), and then estimate the PV of each galaxy based on its offset from the Gaussian mean of the distribution. As demonstrated with the Uchuu-SDSS mock data, the derived PV and momentum power spectra are insensitive to accurate calibration of the massE relation itself, enabling measurements out to a redshift of 0.2, well beyond the current limit of z = 0.1 using other galaxy scaling laws. We then measure the momentum power spectrum and demonstrate that it remains almost unchanged if varying significantly the redshift bin size within which the distance is measured, as well as the intercept and slope of the massE relation, respectively. By fitting the spectra using the perturbation theory model with four free parameters, fσ8 is constrained to fσ8 = 0.459$^{+0.068}_{-0.069}$ over Δz = 0.02–0.2, 0.416$^{+0.074}_{-0.076}$ over Δz = 0.02–0.1, and 0.526$^{+0.133}_{-0.148}$ over Δz = 0.1–0.2. The error of fσ8 is 2.1 times smaller than that by the redshift space distortion (RSD) of the same sample. A Fisher matrix forecast illustrates that the constraint on fσ8 from the massE-based PV can potentially exceed that from the stage-IV RSD in late universe (z<0.5).

Shi, Yong (ORCID:0000000286146275)↗

Self-Consumption of Electricity Produced from PV Systems in Apartment Buildings - Comparison of the Situation in Australia, Austria, Denmark, Germany, Greece, Italy, Spain, Switzerland and the USA

Since 2000 grid-connected solar photovoltaic systems have increased their world-wide cumulative capacity more than 300 times to reach 400 GW at the end of 2017. Another doubling is forecasted until 2020 and the further development is coupled with the question at what prices solar photovoltaic electricity can be provided and delivered to the customers. The installation of PV systems for self-consumption is already now an interesting option for many people but in general limited to those who have access to a rooftop they own or can use. A new development to enable residents of multi apartment buildings to commonly use electricity generated by a PV system is a relatively new development and is still facing a lot of administrative and regulatory challenges.

14 SOLAR ENERGY↗