Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dew point”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Oxy-fuel combustion and power generation system

Integration of an oxyfuel combustion boiler at elevated pressures and a heat exchanger is achieved to produce carbon dioxide by feeding flue gas comprising carbon dioxide and water from the oxyfuel combustion boiler to a direct contact cooler column wherein water is condensed at a temperature of 0 to 10° C. lower than its dew point; feeding a portion of the condensed water from the direct contact cooler column to the oxyfuel combustion boiler; feeding a portion of the carbon dioxide from the direct contact cooler column to the oxyfuel combustion boiler; and recovering a portion of the carbon dioxide from the direct contact cooler column.

Alekseev, Alexander↗

Clean and High-Efficiency Natural Gas Furnace with Advanced Acidic Gas Trap Technology

Ccurrent natural gas condensing furnaces generate substantial acidic condensate and SOx/NOx/CO/HC/methane emissions, causing long-term environment issues related to air, water and soil. Acidic condensate occurs when flue gases within the furnaces cool down below the dew points of acidic gases, which upon condensation, combine with water vapor to produce acidic solutions. The acidic condensate causes serious corrosion and fouling problems in natural gas condensing furnaces. This paper presents a novel solution to use an advanced adsorption technology based on monolithic acidic gas trap (AGT) adsorbers for SOx trapping, NOx redox, and formic acid/CO/HC/methane oxidation, enabling a new natural gas furnace with utra-clean flue gas and neutral condensate. When the AGT adsorber is appropriately integrated with natural gas furnaces, the acidic gases of SOx, NOx and formic gas/CO/HC will be continuously adsorbed, redoxed or oxidized, respectively, from the flue gas during a regular heating season, except for occasional regeneration activities for SOx trapping. In the paper, we present results from a prototype furnace employing the novel AGT component, which enables a pH of the condensate =7, NOx emissions of 1-2 nanograms/joule and an annual fuel utilization efficiency (AFUE) of 96%, providing a cost-effective technology for condensing furnaces that is eco-friendly to the environment.

Gao, Zhiming↗

DATA DRIVEN APPROACH TO ANALYZING THE IMPACT OF POWER PLANT CYCLING ON AIR PREHEATER DEGRADATION AND REMAINING USEFUL LIFE

Due to the increased penetration of renewable energy generation sources, and fluctuations of the oil and gas prices, modern coal burning power plants deal with increased variability in the demand for power generation. These varying demands result in their intermittent under-capacity operation (cycling). Periodical ramping down and back up to follow the daily power demands causes damages to the plant components reducing its operational life. In this paper we analyze the impact of cycling on a rotary Ljungstrom air preheater (APH) unit installed at a coal fire power plant in the US. An inefficient air preheater can significantly impact boiler performance. Due to the repeated boiler’s hot-cold start, the APH experiences fluctuating operating conditions that result in accelerated degradation mechanisms, such as dew-point corrosion, fouling/deposition plugging, and air heater leakage.The analysis in this paper utilizes field data related to APH basket replacement, and the number of cycles experienced by the boiler to model the life expectancy of the baskets. The data-driven model enables preventive maintenance strategies for the APH by predicting how long the APH baskets will last in a probabilistic sense. The analysis showed that an increase in cycling for a fixed operation time can reduce the APH basket remaining useful life by about 30%.

Sharma, Himanshu↗

Multi-Objective Cycle Optimization of an Integrally Geared Waste Heat Recovery Unit for a Combined Cycle Power System

This paper has presented the cycle design and optimization details for a sCO2-based WHRS targeting the Solar Turbines Titan 130. The PreheatSR cycle layout was chosen to effectively address the issue of acid dew point corrosion and ensure high system performance is not significantly impacted by use of alternative fuels. The optimization process discussed uses a multi-objective optimization to discover a series of optimal cycle configurations given ambient temperature variability for a chosen site location while considering the initial capital cost of the cycle components. Cycle models built that incorporated off-design methods for the heat exchangers and turbomachinery allowed for the investigation of cycle operation that maximizes power output for individual cycle conditions. The resulting Pareto front serves as a guide for how to configure the WHRS cycle for the highest yearly energy extracted for a given investment.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

A multi-scale time-series dataset with benchmark for machine learning in decarbonized energy grids

The electric grid is a key enabling infrastructure for the ambitious transition towards carbon neutrality as we grapple with climate change. With deepening penetration of renewable resources, the reliable operation of the electric grid becomes increasingly challenging. In this paper, we present PSML, a first-of-its-kind open-access multi-scale time-series dataset, to aid in the development of data-driven machine learning (ML)-based approaches towards reliable operation of future electric grids. The dataset is synthesized from a joint transmission and distribution electric grid to capture the increasingly important interactions and uncertainties of the grid dynamics, containing power, voltage and current measurements over multiple spatio-temporal scales. Using PSML, we provide state-of-the-art ML benchmarks on three challenging use cases of critical importance to achieve: (i) early detection, accurate classification and localization of dynamic disturbances; (ii) robust hierarchical forecasting of load and renewable energy; and (iii) realistic synthetic generation of physical-law-constrained measurements. We envision that this dataset will provide use-inspired ML research in safety-critical systems, while simultaneously enabling ML researchers to contribute towards decarbonization of energy sectors.

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE Project 3-2417: Meteorological Data During 2024 Stimulation

This preliminary data archive includes meteorological data recorded at the Utah FORGE facility over the period of time including the 16A/16B stimulation activities, largely March/April/May of 2024. This information may prove useful for understanding seismic and other instrumentation response during monitoring. The bulk of relevant stimulation activities occurred between March 25th and April 28th, 2024 and the included files span this period. All sensors were installed at the 78-16 pad and hence reflect weather state at the site. This dataset was acquired by the FOGMORE R&D project (Fiber Optic MOnitoring for Reservoir Evolution), Utah FORGE R&D Project 3-2417.

15 GEOTHERMAL ENERGY↗

Gap-filled meteorological data (2011-2020) and modeled potential evapotranspiration data from the KCOMTCRE2 WeatherUnderground weather station, from the East River Watershed, Colorado

This dataset is a gap-filled meteorological dataset (years 2011-2020) that includes modeled potential evapotranspiration from a station near the pumphouse on the East River (KCOMTCRE2 WeatherUnderground ) near the top of the ridge at the Pumphouse PLM wells. These datasets are useful as model inputs. The KOMTCRE2 station is located on Mt. Crested Butte in Colorado. More information can be found at: https://www.wunderground.com/dashboard/pws/KCOMTCRE2/table/2020-12-7/2020-12-7/daily. The purpose of this dataset is to use as input to hydrological and flow-reactive transport models as meteorological forcing. One attached file includes metadata files with definitions for all variables and units. Subsequent files include the same time series dataset, but aggregated and gap-filled at different time-stamp intervals. These include 5 minute time-series, 15 minute time-series, 30 minute time-series, 1 hour time-series, daily time-series, and hourly and daily modeled evapotranspiration.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

Environmental monitoring data from the 2022-2023 field experiment at Game Ridge, Missoula County, Montana, USA

This dataset contains sensor data from programmed loggers as well as handheld moisture probes, including weather data, air and soil temperature, and soil volumetric water content. Data files and data dictionary(ies) are uploaded as .csv files. The Users Guide is a .pdf file. Location data can be found in the Google Earth file GameRidge_SitePlotCoordinates.kmz.kml included here. These datasets were collected for Plant Carbohydrate Depletion, Mycorrhizal Networks, and Vulnerability to Drought: An Experimental Test in the Field. This experiment examined the interdependency between plant hydraulics and carbohydrate availability and sought to develop ways to incorporate interactions with below ground symbiotic organisms to better model and quantify forest response to drought. This environmental data was collected to provide context for the fungal community data and Pinus ponderosa physiological data.

54 ENVIRONMENTAL SCIENCES↗

Upper-air soundings collected during the CROCUS Urban Canyons 2024 campaign in Chicago, Illinois USA

Funded by the Department of Energy’s Office of Science, Biological and Environmental Research program, Community Research on Climate and Urban Science (CROCUS) studies urban climate change and the impact it has on communities, with particular focus on disinvested, under-resourced communities. This information leads to new insights on urban climate challenges and informs future actions for mitigating and adapting to climate change at the street, neighborhood and regional levels.As part of the CROCUS effort, the Urban Canyons 2024 project was undertaken to study conditions at unprecedented detail over various neighborhoods in Chicago, Illinois. This dataset consists of upper air soundings that were collected as part of this effort. Soundings were launched during two intensive observing periods, IOP1 occurred on 22-23 July 2024, while IOP2 occurred on 27-28 July 2024. For IOP1, soundings were launched at coordinated times from three sites, Shedd Aquarium in Downtown Chicago, Abizu Campus High School in Humboldt Park, and Gary Comer Youth Center in West Woodlawn. For IOP2, the Gary Comer site was replaced by a neighborhood site in West Woodlawn, Chicago. The Abizu Campos site was operated by Valparaiso University and used iMET-4 rawinsondes, the other sites were operated by the University of Illinois Urbana-Champaign and used GRAW DFM-19 sondes.This dataset contains netCDF files containing quality-controlled temperature, dewpoint, geopotential height, pressure, and vector wind measurements at 1 second intervals following launch. These files are readable by the open-source netCDF software libraries available in many software packages (i.e., python, R, fortran, C++, etc.). The dataset also contains quicklook plots of each launch on a skew-T log-p thermodynamic diagram. These are in png format viewable by most web browsers.

54 ENVIRONMENTAL SCIENCES↗

CROCUS High-Frequency Measurements of CO₂, H₂O, Wind, and Temperature at University of Illinois Chicago

As of April 9, 2026: this dataset is currently being versioned to include data up to March 31, 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. Raw atmospheric measurements collected at the University of Illinois Chicago (UIC) as part of the Community Research on Climate and Urban Science (CROCUS) project. The data includes high-frequency measurements of carbon dioxide (CO₂) concentration, water vapor (H₂O) concentration, wind speed (U, V, W components), temperature, and atmospheric pressure. These raw data are recorded by the LI-7500DS Open Path CO₂/H₂O Analyzer and a sonic anemometer at a 10 Hz acquisition frequency, providing the necessary inputs for calculating fluxes of CO₂, H₂O, heat, and momentum. In addition to gas concentration measurements, the dataset includes diagnostic information from the instruments, including absorptance, sample and reference signals, and diagnostic values. The data were collected to study urban atmospheric conditions and contribute to flux calculations for urban climate research. These measurements form the basis for calculating 30-minute average fluxes of key atmospheric variables using the eddy covariance method. This dataset provides critical raw input data for researchers interested in atmospheric fluxes, urban air quality, and the interaction between the urban environment and atmospheric processes. The data is part of the U.S. Department of Energy’s Biological and Environmental Research (BER) program, under the CROCUS Urban Integrated Field Laboratory (UIFL) project.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at Chicago State University Prairie Site

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at Chicago State University (CSU) at a prarie site on campus in Chicago, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). File naming convention includes the project (CROCUS), location (CSU), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at Argonne National Laboratory Prairie Site

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a prairie field site at Argonne National Laboratory in Lemont, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). File naming convention includes the project (CROCUS), location (atmos), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at University of Illinois - Chicago Tower

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at the University of Illinois in Chicago, Illinois, on the meteorological tower near the greenhouse on campus. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. File naming convention includes the project (CROCUS), location (UIC), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗