Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth profiling techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Temperature Uncertainty Modeling with Proxy Structural Data as Geostatistical Constraints for Well Siting: An Example Applied to Granite Springs Valley, NV, USA

Utilizing existing temperature and structural information around Granite Springs Valley, Nevada, we build 3D stochastic temperature models with the aim of evaluating the 3D uncertainty of temperature and choosing between candidate exploration well locations . The data used to support the modeling are measured temperatures and structural proxies from 3D geologic modeling, the latter considered "secondary" data. Two stochastic geostatistical techniques are explored for incorporating the structural proxies: cosimulation and local varying mean. With both the cosimulation and local varying mean methods, many equally likely temperature models (i.e., realizations) are produced, from which temperature probability profiles are calculated at candidate well locations. To aid in choosing between the candidate locations, two quantities summarize the temperature probabilities: Vprior and entropy. Vprior quantifies the likelihood for economic temperatures at each candidate location, whereas entropy identifies where new information has the most potential to reduce uncertainty. In general, the cosimulation realizations have smoother spatial structure, and extrapolate high temperatures at candidate locations that are located along the direction of the longest spatial correlation, which are down dip from existing temperature logs. The smooth realizations result in tight temperature probability profiles that are easier to interpret, but they have unrealistic temperature reversals in some locations because the cosimulation technique does not enforce a conductive geothermal gradient as a baseline (i.e., linearly increasing temperature with depth). The local varying mean results produce realizations with more realistic geothermal gradients, with temperatures increasing downward since a depth-temperature relationship is included. However, because they have much noisier spatial nature compared to cosimulation, it is harder to interpret the temperature probability profiles. The different local varying mean results allow the geologist to determine which proxy (e.g., dilation versus distance to fault termination) should be used given the specific geothermal system. In general, Vprior from local varying mean results identify locations that are close to high values for the structural proxies: areas with highe r probabilities for higher temperatures. The entropy results identify where uncertainty is greatest and therefore new drilling information could be most useful. Though these techniques provide useful information, even when applied to areas of sparse data, our comp arison of these two techniques demonstrates the need for new geothermal geostatistics techniques that combine the advantages of these two methods and that are tailored to the spatial uncertainty issues inherent in geothermal exploration.

3D temperature modeling↗

A Thin Alumina Film as a Tritium Adsorption Inhibitor for Stainless Steel 316

The effect of a thin alumina coating on stainless-steel 316 (SS316) samples on tritium adsorption and transport are discussed. Compact films of alumina were produced on the surfaces of pristine SS316 samples using an atomic layer deposition (ALD) technique. Subsequently, these samples were exposed for 24 hours to a deuterium-tritium gas mixture (P T =0.5 atm, 25°C). A combination of methods including selective-etching and programmed thermal desorption were employed to assess both, the depth profile of the tritium concentration in the sample and the total quantity of tritium absorbed respectively. Tritium was quantitatively determined through the measurement of beta radioactivity using liquid-scintillation counting techniques. Data suggest that SS316 with a thin film of alumina reduces the total tritium uptake by ~25% relative to uncoated samples. Significantly, such films appear to reduce, by a factor of 200, tritium diffusion into SS316 and therefore constitute an effective barrier against tritium transport. This observation is of practical importance for tritium and, generally, reactive gas handling.

36 MATERIALS SCIENCE↗

Synthetic Absorption Lines from Simulations of Multiphase Gas in Galactic Winds

Supernova-driven galactic winds are multiphase streams of gas that are often observed flowing at a range of velocities out of star-forming regions in galaxies. In this study, we use high-resolution 3D simulations of multiphase galactic winds modeled with the hydrodynamics code Cholla to investigate the connection between numerical studies and observations. Using a simulated interaction between a hot $T$ ~ 10 4 K supernova-driven wind and a cool $T$ ~ 10 7 K cloud of interstellar material, we create mock observables, including the optical depth ($\tau$) and covering fraction ($C$ $f$ ) of six commonly observed ions (Si II , C II , Si IV , C IV , N V , and O VI ) as a function of gas velocity. We compare our mock observables to surveys of galactic winds in the literature, finding good agreement with velocities and profiles of the low ions. We then compute "empirical" values for the optical depth and covering fraction following observational techniques and compare them to the values calculated directly from the simulation data. We find that the empirically computed values tend to underestimate the "true" value of $\tau$ for ions with high optical depth and overestimate the "true" value of $\tau$ for ions with low optical depth relative to the simulated data. In conclusion, the empirically estimated covering fractions match our direct calculations very well for the low-ionization ions; for the high-ionization ions, the empirical covering fractions underestimate the directly computed values by up to ~40%.

79 ASTRONOMY AND ASTROPHYSICS↗

An investigation of impurity redistribution in diffused layer on /n+/-p silicon solar cells parameters

Recent calculations by Wang et al. (1974) have shown that the short-circuit current for silicon solar cells is sensitive to the impurity distribution in the diffused and base region. In the present work, these theoretical results were verified by experimentally investigating the impurity profile and sheet resistance of the diffused layers of (n+)-p silicon solar cells fabricated by normal diffusion processes and at subsequently various drive-in times. Impurity profiles of the n+ diffused layer, measured by differential Hall and resistivity technique, resemble the erfc distribution. The junction depth is larger as drive-in time increases. Measured short-circuit current is in agreement with calculated ones. Open-circuit voltage is independent of drive-in times, and its calculated values are consistent with capacitance-voltage measurements.

Wang, E. Y.↗

Climatology of Global Precipitation Measurement Mission Precipitation Regimes and Implications for Global Estimates of Vertical Winds

The Global Precipitation Measurement (GPM) mission Validation Network (VN) framework leverages over 118 ground-based polarimetric Doppler radars to validate a large subset of precipitation measurements and retrievals from the GPM Dual-frequency Precipitation Radar (DPR). Recently, GPM DPR reflectivity profiles within the VN have been classified according to their convective regime using unsupervised machine learning techniques. The archetypal regimes are stratiform, convective, mixed stratiform-convective (e.g., transition regions), and “other” (e.g., peripheral regions of light precipitation). Subcategories within these four primary regimes vary according to the characteristic depth of included reflectivity profiles, resulting in 12 main GPM DPR precipitation profile categories. Polarimetry of ground-based Doppler radars in the VN offers additional insights into the types of precipitation, while pairs of radars positioned near each other enable retrieval of vertical winds via dual-Doppler analysis. Geometrically matched to the DPR reflectivity profiles in the GPM VN, these ground-based data and retrievals contribute more detailed characterization of the distinct kinematic and microphysical structures associated with each of the 12 DPR precipitation regimes. DPR reflectivity profiles linked with wind in the VN are restricted to GPM overpasses of proximal radar pairs that allow dual-Doppler analysis. Although a limited subset of DPR profiles in the VN are matched with vertical motion, agreement between the reflectivity structures paired with wind data and those of the greater DPR dataset in the VN suggest that estimates of vertical motion may be inferred in regions without ground-based measurements. We present a climatology of the 12 convective regimes identified within the DPR VN dataset as well as early efforts to estimate the kinematic and microphysical structures of precipitation profiles within the greater GPM DPR dataset by applying machine learning techniques. Precipitation data paired with global estimates of vertical winds from these efforts offer early insight to and support upcoming missions to retrieve convective mass flux, including the Investigation of Convective Updrafts (INCUS) in the Tropics and the global Atmosphere Observing System (AOS).

Precipitation↗

Remote sensing of subsurface water temperature by laser Raman spectroscopy

This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.

Leonard, D. A.↗

Temperature uncertainty modelling with proxy structural data as geostatistical constraints for well siting: an example applied to Granite Springs Valley, NV, USA

Utilizing existing temperature and structural geology information around Granite Springs Valley, Nevada, we build 3D stochastic temperature models with the aims of evaluating the 3D uncertainty of temperature and choosing between candidate exploration well locations. The data used to support the modelling are measured temperatures and structural proxies from 3D geologic modelling (distance to fault, distance to fault intersections and terminations, Coulomb stress change and dilation tendency), the latter considered ‘secondary’ data. Two stochastic geostatistical techniques are explored for incorporating the structural proxies: cosimulation and local varying mean. With both the cosimulation and local varying mean methods, many equally-likely temperature models (i.e. realizations) are produced, from which temperature probability profiles are calculated at candidate well locations. To aid in choosing between the candidate locations, two quantities summarize the temperature probabilities: V prior and entropy. V prior quantifies the likelihood for economic temperatures at each candidate location, whereas entropy identifies where new information has the most potential to reduce uncertainty. In general, the cosimulation realizations have smoother spatial structure, and extrapolate high temperatures at candidate locations that are located along the direction of the longest spatial correlation, which are down dip from existing temperature logs. The smooth realizations result in tight temperature probability profiles that are easier to interpret, but they have unrealistic temperature reversals in some locations because of the dipping ellipsoid shape created and that the cosimulation technique does not enforce a conductive geothermal gradient as a baseline (i.e. linearly increasing temperature with depth). The local varying mean results produce realizations with more realistic geothermal gradients, with temperatures increasing downward since a depth-temperature relationship is included. However, because they have much noisier spatial nature compared to cosimulation, it is harder to interpret the temperature probability profiles. The different local varying mean results allow the geologist to determine which proxy (e.g. dilation v. distance to fault termination) should be used given the specific geothermal system. In general, V prior from local varying mean results identify locations that are close to high values for the structural proxies: areas with higher probabilities for higher temperatures. The entropy results identify where uncertainty is greatest and therefore new drilling information could be most useful. Though these techniques provide useful information, even when applied to areas of sparse data, our comparison of these two techniques demonstrates the need for new geothermal geostatistics techniques that combine the advantages of these two methods and that are tailored to the spatial uncertainty issues inherent in geothermal exploration.

15 GEOTHERMAL ENERGY↗

Spatial Description of Lithium Plating

Fast charging lithium ion batteries is a critical obstacle to overcome before widespread uptake of electric vehicles. During fast charging, lithium ion batteries in electric vehicles degrade at an accelerated rate, which is frequently caused by lithium plating. In this presentation, three different methods to spatially and temporally detect and quantify lithium plating are presented; notably, mass spectroscopy titration, operando depth profiling X-ray diffraction, and in-situ X-ray diffraction mapping of pouch cells. Each of the tree techniques successfully quantify lithium plating and provide insight into its spatial occurrence within lithium ion cells.

47 OTHER INSTRUMENTATION↗

Advancing Tunnel Detection Via Vertical Acoustic Profiling

This study demonstrates that placing an acoustic source at depth significantly enhances the detection of tunnels. By adapting the methodology of vertical seismic profiling to acoustic-range frequencies, we introduce a novel approach for tunnel detection. To our knowledge, this report documents the first application of this technique. The field study was conducted on a cleared site at the Oak Ridge National Laboratory; the subsurface was clay. A series of vertical shafts were bored immediately before and after the placement of a 40 ft long, 3 ft diameter steel pipe located 10 ft below the surface. Acoustic signatures were produced at various depths up to 30 ft and an array of surface geophones was used to collect the resulting signals. The innovation lies in using subsurface acoustic signatures to better enable the collection of wide-angle diffracted waves by surface geophones. These diffracted waves appear as subharmonic frequencies of the source signal and are recorded by a surface geophone array. While the concept draws from vertical seismic profiling used in oil and gas exploration, a key distinguishing feature is the use of acoustic frequencies, which are necessary for detecting small subsurface features. The findings have important implications. Critical information pertaining to diffracted source signals are not measured by current state-of-the-art methods. Although this study confirms enhanced detectability, accurate localization and imaging will require additional research. Future work should focus on leveraging diffracted-wave strength and time delays to enable full imaging and characterization.

47 OTHER INSTRUMENTATION↗

Slant-lidar aerosol extinction measurements and their relation to measured and calculated albedo changes

Lidar and albedo data for a single day on which aerosols increased the surface plus atmospheric albedo above values measured on two surrounding very clean days are presented. The slant-lidar extinction measurement technique used is described along with the equipment and operating procedures. The derivation of optical depths, backscatter-to-extinction ratios, and extinction profiles is addressed, and the use of the lidar-derived optical depths in calculating expected albedo change is considered. Measured and calculated albedo changes are compared, and the results are found to agree within experimental uncertainties.

Russell, P. B.↗

Niobium's intrinsic coherence length and penetration depth revisited using low-energy muon spin spectroscopy and secondary-ion mass spectrometry

Here, we report direct, simultaneous measurements of the London penetration depth (𝜆 𝐿 ) and Bardeen-Cooper-Schrieffer coherence length (𝜉 0 ) in oxygen-doped niobium, with impurity concentrations spanning the “clean” to “dirty” limits. Two depth-resolved techniques—low-energy muon spin spectroscopy and secondary-ion mass spectrometry—were used to quantify the element's Meissner screening profiles, analyzed within a framework that accounts for nonlocal electrodynamics. The analysis indicates intrinsic length scales of 𝜆 𝐿 = 29.1⁢ (10)⁢ nm and 𝜉 0 = 39.9 ⁢(25)⁢ nm, corresponding to a Ginzburg-Landau parameter 𝜅 = 0.70⁢ (5). The obtained 𝜆 𝐿 and 𝜅 values, accurately quantified at the nanoscale, are smaller than those commonly used in applications and modeling, and indicate that clean niobium lies at the boundary between type-I and type-II superconductivity, supporting the contemporary view that its intrinsic state may be type I.

Particle Accelerator↗

Directed-energy process technology efforts

A summary of directed-energy process technology for solar cells was presented. This technology is defined as directing energy or mass to specific areas on solar cells to produce a desired effect in contrast to exposing a cell to a thermal or mass flow environment. Some of these second generation processing techniques are: ion implantation; microwave-enhanced chemical vapor deposition; rapid thermal processing; and the use of lasers for cutting, assisting in metallization, assisting in deposition, and drive-in of liquid dopants. Advantages of directed energy techniques are: surface heating resulting in the bulk of the cell material being cooler and unchanged; better process control yields; better junction profiles, junction depths, and metal sintering; lower energy consumption during processing and smaller factory space requirements. These advantages should result in higher-efficiency cells at lower costs. The results of the numerous contracted efforts were presented as well as the application potentials of these new technologies.

Alexander, P.↗

Aircraft laser sensing of sound velocity in water - Brillouin scattering

A real-time data source for sound speed in the upper 100 m has been proposed for exploratory development. This data source is planned to be generated via a ship- or aircraft-mounted optical pulsed laser using the spontaneous Brillouin scattering technique. The system should be capable (from a single 10 ns 500 mJ pulse) of yielding range resolved sound speed profiles in water to depths of 75-100 m to an accuracy of 1 m/s. The 100 m profiles will provide the capability of rapidly monitoring the upper-ocean vertical structure. They will also provide an extensive, subsurface-data source for existing real-time, operational ocean nowcast/forecast systems.

Hickman, G. D.↗

Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument

The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing, planned for early March.

Wiens, R. C.↗

High Spectral Resolution Lidar and MPLNET Micro Pulse Lidar Aerosol Optical Property Retrieval Intercomparison During the 2012 7-SEAS Field Campaign at Singapore

From August 2012 to February 2013 a High Resolution Spectral Lidar (HSRL; 532 nm) was deployed at that National University of Singapore near a NASA Micro Pulse Lidar NETwork (MPLNET; 527 nm) site. A primary objective of the MPLNET lidar project is the production and dissemination of reliable Level 1 measurements and Level 2 retrieval products. This paper characterizes and quantifies error in Level 2 aerosol optical property retrievals conducted through inversion techniques that derive backscattering and extinction coefficients from MPLNET elastic single-wavelength datasets. MPLNET Level 2 retrievals for aerosol optical depth and extinction/backscatter coefficient profiles are compared with corresponding HSRL datasets, for which the instrument collects direct measurements of each using a unique optical configuration that segregates aerosol and cloud backscattered signal from molecular signal. The intercomparison is performed, and error matrices reported, for lower (0-5km) and the upper (>5km) troposphere, respectively, to distinguish uncertainties observed within and above the MPLNET instrument optical overlap regime.

MPL↗

Analysis of Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption During the ASCENDS 2009-2011 Airborne Campaigns

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission and have demonstrated the CO2 and O2 measurements from aircraft. Our technique uses two pulsed lasers allowing simultaneous measurement of a single CO2 absorption line near 1572 nm, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are stepped in wavelength across the CO2 line and an O2 line doublet during the measurement. The column densities for the CO2 and O2 are estimated from the differential optical depths (DOD) of the scanned absorption lines via the IPDA technique. For the 2009 ASCENDS campaign we flew the CO2 lidar on a Lear-25 aircraft, and measured the absorption line shapes of the CO2 line using 20 wavelength samples per scan. Measurements were made at stepped altitudes from 3 to 12.6 km over the Lamont OK, central Illinois, North Carolina, and over the Virginia Eastern Shore. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We averaged every 10 seconds of measurements and used a cross-correlation approach to estimate the range to the scattering surface and the echo pulse energy at each wavelength. We then solved for the best-fit CO2 absorption line shape, and calculated the DOD of the fitted CO2 line, and computed its statistics at the various altitude steps. We compared them to CO2 optical depths calculated from spectroscopy based on HITRAN 2008 and the column number densities calculated from the airborne in-situ readings. The 2009 measurements have been analyzed and they were similar on all flights. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. They showed the expected nearly the linear dependence of DOD vs altitude. The measurements showed ~ 1 ppm random errors for 8-10 km altitudes and ~30 sec averaging times. For the 2010 ASCENDS campaigns we flew the CO2lidar on the NASA DC-8 and added an 02lidar channel. During July 2010 we made measurements of CO2 and O2 column absorption during longer flights over Railroad Valley NV, the Pacific Ocean and over Lamont OK. CO2 measurements were made with 30 steps/scan, 300 scans/sec and improved line resolution and receiver sensitivity. Analysis of the 2010 CO2 measurements shows the expected ~linear change of DOD with altitude. For measurements at altitudes> 6 km the random errors were 0.3 ppm for 80 sec averaging times. For the summer 2011 ASCENDS campaigns we made further improvements to the lidar's CO2 line scan and receiver sensitivity. We demonstrated measurements over the California Central Valley, to stratus cloud tops over the Pacific Ocean, over mountain regions with snow, and over several areas with broken clouds. Details of the lidar measurements and their analysis will be described in the presentation.

Abshire, J. B.↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption and Range During the ASCENDS 2009-2011 Airborne Campaigns

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission and have demonstrated the CO2 and O2 measurements from aircraft. Our technique uses two pulsed lasers allowing simultaneous measurement of a single CO2 absorption line near 1572 nm, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are stepped in wavelength across the CO2 line and an O2 line doublet during the measurement. The column densities for the CO2 and O2 are estimated from the differential optical depths (DOD) of the scanned absorption lines via the IPDA technique. For the 2009 ASCENDS campaign we flew the CO2 lidar only on a Lear-25 aircraft, and measured the absorption line shapes of the CO2 line using 20 wavelength samples per scan. Measurements were made at stepped altitudes from 3 to 12.6 km over the Lamont OK, central Illinois, North Carolina, and over the Virginia Eastern Shore. Although the received signal energies were weaker than expected for ASCENDS, clear C02 line shapes were observed at all altitudes. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We averaged every 10 seconds of measurements and used a cross-correlation approach to estimate the range to the scattering surface and the echo pulse energy at each wavelength. We then solved for the best-fit CO2 absorption line shape, and calculated the DOD of the fitted CO2 line, and computed its statistics at the various altitude steps. We compared them to CO2 optical depths calculated from spectroscopy based on HITRAN 2008 and the column number densities calculated from the airborne in-situ readings. The 2009 measurements have been analyzed in detail and they were similar on all flights. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. They showed the expected nearly the linear dependence of DOD vs altitude. The measurements showed -1 ppm random errors for 8-10 km altitudes and -30 sec averaging times. For the 2010 ASCENDS campaigns we flew the CO2 lidar on the NASA DC-8 and added an O2 lidar channel. During July 2010 we made measurements of CO2 and O2 column absorption during longer flights over Railroad Valley NV, the Pacific Ocean and over Lamont OK. CO2 measurements were made with 30 steps/scan, 300 scans/sec and improved line resolution and receiver sensitivity. Analysis of the 2010 CO2 measurements shows the expected -linear change of DOD with altitude. For measurements at altitudes> 6 km the random errors were 0.3 ppm for 80 sec averaging times. For the summer 2011 ASCENDS campaigns we made further improvements to the lidar's CO2 line scan and receiver sensitivity. The seven flights in the 2011 Ascends campaign were flown over a wide variety of surface and cloud conditions in the US, which produced a wide variety of lidar signal conditions. Details of the lidar measurements and their analysis will be described in the presentation.

Abshire, J. B.↗

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗