Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth migration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Assessment of TeF 6 Adsorption

Research and development that supports the management of off-gases from nuclear fuel reprocessing has historically been focused on the off-gas streams that arise from aqueous reprocessing technology. However, as Gen-IV reactor development pathways move toward deployment, alternative spent nuclear fuel (SNF) processing and disposition pathways have been considered more actively. This work is focused upon aspects of fluoride volatility (FV) processing. The versatility of this method for deployment against multiple types of spent fuel encourages the continued advancement of both the primary separations processes and the secondary processes, including waste treatment, material control and accountability, and engineering designs. Recent work noted that TeF 6 , the most highly volatile fluorinated compound produced during FV processing, did not have a clear abatement technology recommended in the literature. Thus, this work performed scoping tests on activated alumina and copper shot to assess whether they could be used to remove TeF 6 from gas streams that bear F 2 . Previous work on this topic was not well described in the literature and was not performed with excess F 2 in the stream as would be typical of spent fuel processing via FV. To support an understanding of the concentration of TeF 6 contacting the adsorbent beds, a series of preliminary testing identified the TeF 6 production rate and the equilibrium concentration of TeF 6 in the gas stream contacting the adsorbent. Excess F 2 was determined to not affect the ability of activated alumina to remove TeF 6 from the gas stream quickly and completely. A determination of whether excess F 2 affected the distribution depth of Te in the sorbent bed is still pending analysis of the used sorbent. Literature suggests that when activated alumina is near saturation, TeF 6 could migrate from the sorbent bed. Future testing should investigate this possibility. Copper metal did not adsorb TeF 6 in the presence of F 2 across the sorbent temperature range of 50 to 335°C. F 2 was fully removed by the copper bed. Although preliminary thermodynamics would indicate adsorption to be energetically favorable, other factors that impact adsorption (e.g., slow kinetics, excess fluorine on the copper surface, an unfavorable transition state) are likely preventing the adsorption of TeF 6 at an easily measurable rate. The work also investigated TeF 6 production from multiple forms of Te in the temperature range of 100 to 250°C. No previous study had assessed the initial reaction rates for this process. A carefully designed study allowed determination of the activation energy for the production of TeF 6 from Te metal. The substantial amount of data collected during this study merits analysis beyond what is described here. A more in-depth kinetic analysis will be pursued. Additional analytical results will provide the ability to benchmark adsorption coefficients for TeF 6 , understand the distribution of TeF 6 within the alumina bed, and better understand the effect of F 2 partial pressure on Te fluorination. The data from this report, as supplemented by these additional analyses, will be submitted to a peer-reviewed journal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

Formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

The formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

Formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Local control of perpendicular magnetic anisotropy of Pd/Co multilayers via ion bombardment

In this work, we have controlled locally the magnetic anisotropy of PdCo multilayers using ion beam modification. First, we have used techniques with different probing depths to confirm that cobalt is partially oxidized in the Pd/Co multilayers exhibiting PMA fabricated by sputtering, presumably due to the diffusion of atmospheric oxygen migrated through the Pd capping layer. Then, low energy ion bombardment has been employed to induce a structural disorder in the upper layers of the multilayer, gradually reducing the PMA at local scale with increasing ion doses. Medium ion doses lead to a marked decline in PMA, resulting in equivalent magnetic anisotropy directions and the loss of characteristic labyrinthine magnetic domain morphology. High ion doses completely suppress PMA, yielding a typical in-plane shape anisotropy. Furthermore, by combining controlled PMA reduction via lithographic techniques, we create elongated structures displaying distinct magnetic responses; bombarded regions exhibit reduced PMA, whereas adjacent regions maintain their PMA. Notably, regions with reduced PMA do not disrupt the distribution of perpendicular magnetic domains in neighboring PMA regions, even at widths as narrow as 500 nm, demonstrating the robustness of the PMA domain structure.

Sebastiani-Tofano, Eugenia [Universidad Complutens↗

UV–Vis–NIR Reflectance Spectroscopy and Chemometrics for Monitoring Pu Directly on an Ion Exchange Column

Here, we present a fiber-optic UV–vis–NIR reflectance spectroscopy method for direct, noninvasive monitoring of Pu(IV) in a glass ion exchange column during dynamic loading and elution in a glovebox. A movable probe enables spatially resolved spectral acquisition along the column axis, capturing distinct features associated with Pu(IV) nitrate complexes during loading and free ions during elution. Principal component analysis was applied to extract the dominant spectral variance and resolve relative concentration profiles without requiring precise knowledge of optical penetration depth or species identity. This in situ approach reveals spatial gradients and speciation dynamics in real time, which provides actionable insight into Pu(IV) ion migration, resin saturation, and breakthrough behavior under evolving flow conditions. The method offers a practical, fiber-compatible strategy to monitor glass column–based separations for Pu and other lanthanides or actinides and to characterize metal–resin interactions in flow-through systems.

actinide↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Light hydrocarbon and noble gas migration as an analogue for potential CO 2 leakage: numerical simulations and field data from three hydrocarbon systems

Abstract Sites where anthropogenic CO 2 captured from industrial sources is stored in deep geological formations for climate change mitigation are required to show secure retention of the injected CO 2 . Monitoring, reporting, and verification (MRV) plans are needed to indicate that no CO 2 release has occurred. We explored the degree to which direct comparison between a surface anomaly and reservoir geochemistry using various geochemical parameters can be used for attribution. We used data collected on light hydrocarbons and noble gases throughout the sedimentary column at three CO 2 enhanced oil recovery (EOR) sites to understand the processes that may cause fluid evolution. Light hydrocarbon and noble gases were sampled from reservoirs, gas‐bearing intervals above reservoirs, and groundwater. Vertical profiles indicated that lighter components are relatively enriched during migration (i.e. chromatographic separation). Static and numerical models were designed to simulate episodic gas migration and geochemical alteration of these geochemical parameters from solubility and sorption. The effects of hydrocarbon solubility were minimal (Bernard ratio changes within 5.2%) although field data were within the range of expected alterations from sorption. Forward models of CO 2 migration and noble gas interactions showed that CO 2 stripping causes an enrichment of crustal noble gases. In areas where natural fluxes of CO 2 from depth are non‐existent, the occurrence of crustal noble gas signature may distinguish fugitive CO 2 from the reservoir from natural near‐surface sources, and could be considered to explain apparent fluid anomalies. © 2019 Society of Chemical Industry and John Wiley & Sons, Ltd.

Anderson, Jacob↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed.

Jones, W. R.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed. Previously announced in STAR as N82-24322

Jones, W. R., Jr.↗

Electrical Resistivity Tomography of the 216-U-5 and 216-U-6 WA-1 Waste Sites

The subsurface below the 216-U-5 and 216-U-6 sites needs to be characterized as part of the remedial investigation of the 200-WA-1 operable unit at the Hanford Site. Electrical resistivity tomography (ERT) was selected as a first step in this characterization effort to provide information about the three-dimensional distribution of historically disposed waste fluids in the subsurface beneath these sites. ERT does not directly image specific contaminants. However, ERT provides a three-dimensional image of subsurface zones where the bulk electrical conductivity is higher than surrounding background values. Disposed waste fluids can increase the bulk electrical conductivity in the subsurface where they are present by increasing the moisture content and because the high concentration of waste-fluid constituents such as nitrate cause the fluid to have a higher specific conductance than background pore water. Thus, zones of increased bulk electrical conductivity in the subsurface can be interpreted as zones where waste fluids are present. An ERT survey of the subsurface beneath the 216-U-5 and 216-U-6 sites was conducted to collect ERT data suitable for interpreting the bulk electrical conductivity distribution in the subsurface. Data interpretation was applied using the NQA-1 qualified E4D ERT parallel modelling and inversion code (Johnson 2014). A summary cross-section and interpretation of the 216-U-5 and 216-U-6 ERT is provided in Figure S.1. The ERT image reveals two distinct zones of anomalous bulk conductivity emanating from 216-U-5 and 216-U-6 that merge at a depth of approximately 14 m below the surface and continue to a depth of no more than 26 m below the surface, which is approximately 60 m above the current water table elevation. The image also suggests that lateral transport of waste streams disposed into 216-U-5 and 216-U-6 was limited. These results are consistent with historical groundwater monitoring, which indicated that the disposed waste had not migrated to the water table, possibly due to the relatively low volumes of waste discharge into 216-U-5 and 216-U-6. The ERT information provides a line of evidence supporting this conclusion and can be used to guide the selection of characterization borehole(s) location and depth as needed for additional characterization of the contaminant distribution and properties at these sites. Locations of bulk conductivity anomalies associated with 216-U-5 and 216-U-6 releases are offset approximately 10 m to the west of the locations of 216-U-5 and 216-U-6 as recorded in the Waste Information Data System database. There are two predominant regions of elevated bulk conductivity in addition to those associated with 216-U-5 and 216-U-6. The first is located beneath Beloit Ave. from approximately 190 to 195 m in elevation. The small region of high conductivity directly beneath Beloit Ave. is likely an artifact resulting from the failure to account for the Beloit Ave. topographic rise in the ERT modeling, as that information was unavailable. Information concerning the precise positioning of the railroad tracks shown was also unavailable, particularly in the vertical dimension. The high conductivity anomaly beneath the assumed railroad track location is likely caused by misplacement of the tracks in the ERT model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating PID Shunting in Polycrystalline CIGS Devices via Multi-Scale, Multi-Technique Characterization

We investigated potential-induced degradation (PID) in CuIn 1-x Ga x Se 2 (CIGS) mini-modules stressed in the laboratory. Small cores were removed from the modules and were subjected to analysis. We completed a proof-of-concept correlative study relating cathodoluminescence to sodium content via time-of-flight secondary-ion mass spectrometry imaging. By comparing one-dimensional depth profile results and three-dimensional tomography results on stressed and unstressed CIGS mini-modules, we can see that PID in CIGS results from sodium migration through absorber, most likely via grain boundaries. Potassium concentration distributions show little change when adding a voltage bias to a temperature and humidity stress. This suggests doping with other large alkali ions, such as cesium and rubidium, rather than sodium can increase the PID resistance of CIGS modules.

14 SOLAR ENERGY↗

Future Antarctic Bed Topography and Its Implications for Ice Sheet Dynamics

The Antarctic bedrock is evolving as the solid Earth responds to the past and ongoing evolution of the ice sheet. A recently improved ice loading history suggests that the Antarctic Ice Sheet (AIS) has generally been losing its mass since the Last Glacial Maximum. In a sustained warming climate, the AIS is predicted to retreat at a greater pace, primarily via melting beneath the ice shelves.We employ the glacial isostatic adjustment (GIA) capability of the Ice Sheet System Model (ISSM) to combine these past and future ice loadings and provide the new solid Earth computations for the AIS.We find that past loading is relatively less important than future loading for the evolution of the future bed topography. Our computations predict that the West Antarctic Ice Sheet (WAIS) may uplift by a few meters and a few tens of meters at years AD 2100 and 2500, respectively, and that the East Antarctic Ice Sheet is likely to remain unchanged or subside minimally except around the Amery Ice Shelf. The Amundsen Sea Sector in particular is predicted to rise at the greatest rate; one hundred years of ice evolution in this region, for example, predicts that the coastline of Pine Island Bay will approach roughly 45mmyr−1 in viscoelastic vertical motion. Of particular importance, we systematically demonstrate that the effect of a pervasive and large GIA uplift in the WAIS is generally associated with the flattening of reverse bed slope, reduction of local sea depth, and thus the extension of grounding line (GL) towards the continental shelf. Using the 3-D higher-order ice flow capability of ISSM, such a migration of GL is shown to inhibit the ice flow. This negative feedback between the ice sheet and the solid Earth may promote stability in marine portions of the ice sheet in the future.

ice dynamics↗

Voltage bias stress effects in metal halide perovskites are strongly dependent on morphology and ion migration pathways

The solar-to-power power conversion efficiencies (PCEs) of metal halide perovskites (MHP) have improved over the last decade using a wide variety of methods, including composition manipulation, dopant introduction, and interfacial buffers. These methods, however, have taken little regard for the electronic and interfacial effects such alterations may cause within devices under voltage bias stress – a condition required for most device operation. We investigate how halide and cation substitution in MHP structures [specifically, CH 3 NH 3 PbI 2.87 Cl 0.13 and Cs 0.1 (MA 0.17 FA 0.83 ) 0.9 Pb(I 0.83 Br 0.17 ) 3 ] effects the current behavior of devices while under a range of voltage bias stress in both light and dark conditions. Additionally, conducting in depth investigations into the electronic and morphological differences between these two MHP devices, we confirmed their unique voltage bias stress effects are due to intrinsic behavior within the perovskite structure. Importantly, we also determined how crystallite orientation can influence ion migration and therefore alter charge transport and current stability in MHP photovoltaic devices.

36 MATERIALS SCIENCE↗

Multi-Year Movements of Blacknose, Finetooth, & Sharpnose Sharks in the US South Atlantic Based on Monitoring Within a Regional-Scale Acoustic Telemetry Network

Despite their numerical abundance and economic value, the behavior of many small coastal sharks in the US South Atlantic has been only coarsely described. Here we present movement summaries for blacknose (Carcharhinus acronotus), finetooth (C. isodon), and Atlantic sharpnose shark (Rhizoprionodon terraenovae) as they travelled through a regional-scale acoustic telemetry network, offering direct comparisons of habitat utilization, site fidelity, and the extent and timing of coastal migrations. From 2013-2016, 165 total sharks were implanted with acoustic transmitters at Cape Canaveral, Florida, and tracked up to four years. While blacknose sharks were common off east Florida year-round, finetooth sharks were most abundant winter through early spring and sharpnose sharks summer through fall. Blacknose sharks also moved more slowly (mean 0.8 kilometers per hour) and had the broadest depth preferences, while finetooth sharks were strongly shore-associated and sharpnose preferred proportionally deeper waters. All species exhibited low site fidelity when at Cape Canaveral, remaining at the same site for more than 1 hour on average, even when associated with deeper hard-bottom sites. Most finetooth and many blacknose undertook spring migrations as far as Virginia and North Carolina, respectively, before returning to east Florida each winter. Sharpnose also made regular northward movements that were not as obviously seasonally-driven. Multiple individuals of all species, particularly females, returned briefly south to Cape Canaveral in mid-summer, illustrating that coastal migrations in these species are more akin to seasonal expansions of their geographic ranges as opposed to a synchronized shift of the entire population along the coast.

Reyier, Eric↗

Mapping of carbon concentrations in the Allende meteorite with the C-12(d,p)C-13 method

Carbon concentrations in a 4.2 x 4.2 mm area of the Allende meteorite were mapped with the C-12(d,p)C-13 nuclear method. The x,y resolution perpendicular to the deuteron beam was 65 microns; the depth resolution was 0.6 micron. The matrix of the meteorite contains about 1 wt pct carbon, which is uniformly distributed at the 65-micron level of resolution. The matrix contains most, perhaps close to all, C of this meteorite. The coarse-grained constituents, such as chondrules, show a very strong enhancement of C in the depth range 2 to about 0 micron; the matrix does not show this enhancement. The enhancement may be due to contamination of the coarse-grained areas or else to migration of C in solid solution from the interiors of comparatively large crystals to their freshly polished surfaces.

Van Der Stap, C. A. H.↗

Helium irradiated cavity formation and defect energetics in Ni-based binary single-phase concentrated solid solution alloys

In this study, binary single-phase concentrated solid solution alloys (SPCSAs), including Ni 80 Co 20 , Ni 80 Fe 20 , Ni 80 Cr 20 , Ni 80 Pd 20 , and Ni 80 Mn 20 (in atomic percentage), were irradiated with 200 keV He + ions at 500 °C. He cavity size and density distribution were systematically investigated using transmission electron microscope. Here we show that alloying elements have a clear impact on He cavity formation. Cavity size is the smallest in Ni 80 Mn 20 but the largest in Ni 80 Co 20 . Alloying elements could also substantially affect cavity density profile. In-depth examination of cavities at peak damage region (~500 nm) and at low damage region (~300 nm) demonstrates that cavity size is depth (damage) dependent. Competition between consumption and production of vacancies and He atoms could lead to varied cavity size. Density functional theory (DFT) calculations were performed to obtain the formation and migration energies of interstitials and vacancies. Combined experimental and simulation results show that smaller energy gap between interstitial and vacancy migration energies may lead to smaller cavity size and narrower size distribution observed in Ni 80 Mn 20 , comparing with Ni 80 Co 20 . Finally, the results of this study call attention to alloying effects of specific element on cavity formation and defect energetics in SPCSAs, and could provide fundamental understanding to predict radiation effects in more complexed SPCSAs, such as high entropy alloys.

36 MATERIALS SCIENCE↗