Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “decaying DC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Observation of spin-glass behavior in nickel adsorbed few layer graphene

Nickel-adsorbed graphene was prepared by first synthesizing graphite oxide (GO) by modified Hummers' method and then reducing a solution containing both GO and Ni{sup 2+}. Energy dispersive X-ray spectroscopy analysis showed 31 at. % nickel was present. Magnetization measurements under both dc and ac magnetic fields were carried out in the temperature range 2 K to 300 K. The zero field cooled and field cooled magnetization data showed a pronounced irreversibility at a temperature around 20 K. The analysis of the ac susceptibility data was carried out by both Vogel-Fulcher as well as power law. From dynamic scaling analysis, the microscopic flipping time {tau}{sub 0}{approx}10{sup -13}s and critical exponent z{nu}=5.9{+-}0.1 were found, indicating the presence of conventional spin glass in the system. The spin glass transition temperature was estimated as 19.5 K. Decay of thermoremanent magnetization was explained by stretched exponential function with a value of the exponent as 0.6. From the results, it is concluded that nickel adsorbed graphene behaves like a spin-glass.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study of nitrogen flowing afterglow with mercury vapor injection

The reaction kinetics in nitrogen flowing afterglow with mercury vapor addition was studied by optical emission spectroscopy. The DC flowing post-discharge in pure nitrogen was created in a quartz tube at the total gas pressure of 1000 Pa and discharge power of 130 W. The mercury vapors were added into the afterglow at the distance of 30 cm behind the active discharge. The optical emission spectra were measured along the flow tube. Three nitrogen spectral systems – the first positive, the second positive, and the first negative, and after the mercury vapor addition also the mercury resonance line at 254 nm in the spectrum of the second order were identified. The measurement of the spatial dependence of mercury line intensity showed very slow decay of its intensity and the decay rate did not depend on the mercury concentration. In order to explain this behavior, a kinetic model for the reaction in afterglow was developed. This model showed that the state Hg(6 {sup 3}P{sub 1}), which is the upper state of mercury UV resonance line at 254 nm, is produced by the excitation transfer from nitrogen N{sub 2}(A{sup 3}Σ{sup +}{sub u}) metastables to mercury atoms. However, the N{sub 2}(A{sup 3}Σ{sup +}{sub u}) metastables are also produced by the reactions following the N atom recombination, and this limits the decay of N{sub 2}(A{sup 3}Σ{sup +}{sub u}) metastable concentration and results in very slow decay of mercury resonance line intensity. It was found that N atoms are the most important particles in this late nitrogen afterglow, their volume recombination starts a chain of reactions which produce excited states of molecular nitrogen. In order to explain the decrease of N atom concentration, it was also necessary to include the surface recombination of N atoms to the model. The surface recombination was considered as a first order reaction and wall recombination probability γ = (1.35 ± 0.04) × 10{sup −6} was determined from the experimental data. Also sensitivity analysis was applied for the analysis of kinetic model in order to reveal the main control parameters in the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flux creep in Bi2Sr2CaCu2O8(sub +x) single crystals

The results of a magnetic study on a Bi2Sr2CaCu2O(8+x) single crystal are reported. Low field susceptibility (dc and ac), magnetization cycles and time dependent measurements were performed. With increasing the temperature the irreversible regime of the magnetization cycles is rapidly restricted to low fields, showing that the critical current J(sub c) becomes strongly field dependent well below T(sub c). At 2.4 K the critical current in zero field, determined from the remanent magnetization by using the Bean formula for the critical state, is J(sub c) = 2 10(exp 5) A/sq cm. The temperature dependence of J(sub c) is satisfactorily described by the phenomenological law J(sub c) = J(sub c) (0) (1 - T/T(sub c) (sup n), with n = 8. The time decay of the zero field cooled magnetization and of the remanent magnetization was studied at different temperatures for different magnetic fields. The time decay was found to be logarithmic in both cases, at least at low temperatures. At T = 4.2 K for a field of 10 kOe applied parallel to the c axis, the average pinning energy, determined by using the flux creep model, is U(sub o) = 0.010 eV.

Agostinelli, E.↗

Astrophysical reaction rates for {sup 58,60}Ni(n,{gamma}) from new neutron capture cross section measurements

New neutron capture cross sections of {sup 58,60}Ni were measured in the energy range from 100 eV to 600 keV using the Oak Ridge Electron Linear Accelerator. The combination of these new neutron capture data with previous transmission data allowed a resonance analysis up to 900 keV using R-matrix theory. The theoretically determined direct capture cross sections were included in the analyses. From these resonance parameters and the direct capture contribution, new (n,{gamma}) astrophysical reaction rates were determined over the entire energy range needed by the latest stellar models describing the so-called weak s process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the ATLAS muon triggers in Run 2

The performance of the ATLAS muon trigger system is evaluated with proton-proton ( pp ) and heavy-ion (HI) collision data collected in Run 2 during 2015–2018 at the Large Hadron Collider. It is primarily evaluated using events containing a pair of muons from the decay of Z bosons to cover the intermediate momentum range between 26 GeV and 100 GeV. Overall, the efficiency of the single-muon triggers is about 68% in the barrel region and 85% in the endcap region. The p T range for efficiency determination is extended by using muons from decays of J ψ mesons, W bosons, and top quarks. The performance in HI collision data is measured and shows good agreement with the results obtained in pp collisions. The muon trigger shows uniform and stable performance in good agreement with the prediction of a detailed simulation. Dedicated multi-muon triggers with kinematic selections provide the backbone to beauty, quarkonia, and low-mass physics studies. The design, evolution and performance of these triggers are discussed in detail.

47 OTHER INSTRUMENTATION↗

Acousto-ultrasonics to Assess Material and Structural Properties

This report was created to serve as a manual for applying the Acousto-Ultrasonic NDE method, as practiced at NASA Glenn, to the study of materials and structures for a wide range of applications. Three state of the art acousto-ultrasonic (A-U) analysis parameters, ultrasonic decay (UD) rate, mean time (or skewing factor, "s"), and the centroid of the power spectrum, "f(sub c)," have been studied and applied at GRC for NDE interrogation of various materials and structures of aerospace interest. In addition to this, a unique application of Lamb wave analysis is shown. An appendix gives a brief overview of Lamb Wave analysis. This paper presents the analysis employed to calculate these parameters and the development and reasoning behind their use. It also discusses the planning of A-U measurements for materials and structures to be studied. Types of transducer coupling are discussed including contact and non-contact via laser and air. Experimental planning includes matching transducer frequency range to material and geometry of the specimen to be studied. The effect on results of initially zeroing the DC component of the ultrasonic waveform is compared with not doing so. A wide range of interrogation problems are addressed via the application of these analysis parameters to real specimens is shown for five cases: Case 1: Differences in density in [0] SiC/RBSN ceramic matrix composite. Case 2: Effect of tensile fatigue cycling in [+/-45] SiC/SiC ceramic matrix composite. Case 3: Detecting creep life, and failure, in Udimet 520 Nickel-Based Super Alloy. Case 4: Detecting Surface Layer Formation in T-650-35/PMR-15 Polymer Matrix Composites Panels due to Thermal Aging. Case 5: Detecting Spin Test Degradation in PMC Flywheels. Among these cases a wide range of materials and geometries are studied.

Kautz, Harold E.↗

Effects of EMF Emissions from Cables and Junction Boxes on Marine Species

Studies have shown that diverse aquatic species are electrosensitive. Many fishes, and marine mammals, can either detect, navigate by, or are affected by electromagnetic fields (EMF) with various sensitivities, and their behavior may be impacted by unnatural EMF emissions in the water column. Sharks, rays and skates are known to have the highest sensitivity to electric fields. Electric field emissions in the range 0.5–100 micro volt/m appear to attract them, and emissions over 100 micro volt/m to repulse them. A marine hydrokinetic MHK device will have multiple components and associated multiple submarine cables on the seafloor and running through the water column and would potentially increase the level of EMF emissions to which the marine species at the site may be exposed to. There are therefore concerns amongst stakeholders that EMF emissions associated with MHK devices and their components may act as barriers to species migration, cause disorientation, change community compositions and ecosystems, and that they may attract sharks, leading to a local increase in the risk of shark attacks. However, field data to validate and model potential relationships between observed responses and the EMF emissions in situ are sparse. A program of experimental field surveys were conducted off the coast of South Florida, USA to characterize the electromagnetic field (EMF) emissions in the water column from a submarine cable, and to monitor for responses of local aquatic species. The field surveys were conducted at the South Florida Ocean Measurement Facility (SFOMF) off Fort Lauderdale, which is a cabled offshore in-water navy range. It consists of multiple active submarine power cables and a number of junction boxes, with the capability to transmit AC/DC power at a range of strength and frequencies. The site includes significant marine life activities and community structure, including highly mobile species, such as sharks, stingrays, mammals and turtles. SFOMF therefore typifies a setting representative of an offshore location where a MHK device may be sited. Background electromagnetic field (EMF) levels and EMF emissions due to submarine cables were measured using a custom E-field sensor and a commercial magnetometer deployed from an autonomous underwater vehicle (AUV) at various fixed altitudes above the seafloor. EMF signatures detected from power cables and junction boxes are contrasted against ambient background levels and other EMF sources. The potential responses of local marine species were observed at selected representative locations using divers on SCUBA, complemented with fixed cameras on the sea bottom and by a set of video cameras mounted on the AUV. The objectives of the study were: 1) to characterize the EMF emission levels associated with submarine cables 2) to monitor potential responses of aquatic animals to the emissions and 3) to develop an associated database of field observations. As control, observations of EMF levels and in situ marine species were conducted with power in the cable turned off. Good quality measurements of EMF emissions were obtained using the mobile AUV platform and the data from the surveys were used to develop contour maps of the EMF levels in the water column above the live cable as well as to provide information about how the field decays away from the cable. The measurements show good agreement with theoretical models of the how EMF levels decay away from the cable in deep and shallow water environment. Electric fields in excess of 200µV/m were measured in the vicinity of the cable during the power on state. Quarterly surveys by SCUBA divers were conducted, using point and transect count methods, over a period of one year at three locations, one at a shallow site where the water depth is approximately 5m, and the other at the Barracuda Reef where the water depth is approximately 10m. The sampling results were analyzed to determine if the presence of an SFOMF generated EMF alters: (1) abundance, species richness, and assemblage structure of coral reef fishes, (2) the behavior of fishes including elasmobranchs, and (3) the distribution of marine turtles and mammals. Diver observations were also used in attempt to discern if there were any noticeable organismal responses during the transitional period between ambient OFF to energized AC or DC power states, and video footage was intended to augment the in-situ visual survey data and aid in interpretation of the results. Comparisons are provided between observation datasets between the three sites and between the point and transect count methods. Presence of several individual elasmobranch species, including sharks and stingrays, were recorded during the surveys. No apparent effect on richness could be discerned between the power on and off states. No apparent sudden animal movements were observed during transitions between power states.

16 TIDAL AND WAVE POWER↗

Magnetization dynamics in La{sub 0.67}Ca{sub 0.33}MnO{sub 3} epitaxial films probed with resonant and non-resonant microwave absorption

Temperature (T) dependent microwave absorption measurements are performed on La{sub 0.67}Ca{sub 0.33}MnO{sub 3} (LCMO) epitaxial thin films of thickness 100 and 200 nm in an electron paramagnetic resonance spectrometer operating in X-band. The resonant absorption peak is monitored for out-of-plane (H{sup ⊥}) and in-plane (H{sup ∥}) dc magnetic field (H) as the system goes through magnetic ordering. These data suggest a resilient transformation to the ferromagnetic (FM) phase in the vicinity of the Curie temperature (T{sub C}), indicative of a phase separation, which is dominant in the thinner film. The saturation magnetization is calculated from SQUID magnetometry on the same film. A pronounced zero-field absorption is seen in H{sup ∥} geometry displaying anomalous growth in 100 nm film at T < T{sub C}. This feature is correlated with the magneto-conductivity of the manganite which is colossal in the vicinity of T{sub C} in the well-ordered film of thickness 200 nm. Signature of standing spin wave modes is seen in H{sup ⊥} measurements which are analyzed to calculate the spin wave stiffness constant D(T) in the limit of zero temperature. The same is also inferred from the decay of equilibrium magnetization in the framework of Bloch law. These studies reveal that a bulk like LCMO is obtained in the fully relaxed thicker films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Critical behavior of quasi-two-dimensional semiconducting ferromagnet Cr 2 Ge 2 Te 6

Some critical properties of the single-crystalline semiconducting ferromagnet Cr 2 Ge 2 Te 6 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic phase transition. Critical exponents β = 0.200 ± 0.003 with a critical temperature T c = 62.65 ± 0.07 K and γ = 1.28 ± 0.03 with T c = 62.75 ± 0.06 K are obtained by the Kouvel-Fisher method whereas δ = 7.96 ± 0.01 is obtained by a critical isotherm analysis at T c = 62.7 K. These critical exponents obey the Widom scaling relation δ = 1 + γ / β , indicating self-consistency of the obtained values. Furthermore, with these critical exponents the isotherm M ( H ) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m = f ± ( h ) , where m and h are renormalized magnetization and field, respectively. The determined exponents match well with those calculated from the results of the renormalization group approach for a two-dimensional Ising system coupled with a long-range interaction between spins decaying as J ( r ) ≈ r - ( d + σ ) with σ = 1.52 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for exotic decays of the Higgs boson into $b\bar{b}$ and missing transverse momentum in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for the exotic decay of the Higgs boson (H) into a $b\bar{b}$ resonance plus missing transverse momentum is described. The search is performed with the ATLAS detector at the Large Hadron Collider using 139 fb -1 of pp collisions at $\sqrt{s}$ = 13 TeV. The search targets events from $ZH$ production in an NMSSM scenario where H → $\tilde{χ}^0_2\tilde{χ}^0_1$, with $\tilde{χ}^0_2$ → a$\tilde{χ}^0_1$, where a is a light pseudoscalar Higgs boson and $\tilde{χ}^0_{1,2}$ are the two lightest neutralinos. The decay of the a boson into a pair of b-quarks results in a peak in the dijet invariant mass distribution. The final-state signature consists of two leptons, two or more jets, at least one of which is identified as originating from a b-quark, and missing transverse momentum. Observations are consistent with Standard Model expectations and upper limits are set on the product of cross section times branching ratio for a three-dimensional scan of the masses of the $\tilde{χ}^0_2\tilde{χ}^0_1$ and a boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the CP-violating phase &straightphi; s in B$_s^0$→J/ψ&straightphi; decays in ATLAS at 13 TeV

A measurement of the B$_s^0$→J/ψ&straightphi; decay parameters using 80.5 fb -1 of integrated luminosity collected with the ATLAS detector from 13 Te proton–proton collisions at the LHC is presented. The measured parameters include the CP-violating phase &straightphi; s , the width difference Δ Γ s between the B$_s^0$ meson mass eigenstates and the average decay width Γ s . The values measured for the physical parameters are combined with those from 19.2fb -1 of 7 and 8 Te data, leading to the following: &straightphi;s=-0.087±0.036(stat.)±0.021(syst.)rad ΔΓ s =0.0657±0.0043(stat.)±0.0037(syst.)ps -1 Γ s =0.6703±0.0014(stat.)±0.0018(syst.)ps -1 Results for &straightphi; s and Δ Γ s are also presented as 68% confidence level contours in the &straightphi; s –Δ Γ s plane. Furthermore the transversity amplitudes and corresponding strong phases are measured. &straightphi; s and Δ Γ s measurements are in agreement with the Standard Model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Measurements of the production cross-section for a Z boson in association with b -jets in proton-proton collisions at √s = 13 TeV with the ATLAS detector

This paper presents a measurement of the production cross-section of a Z boson in association with b-jets, in proton-proton collisions at √s = 13 TeV with the ATLAS experiment at the Large Hadron Collider using data corresponding to an integrated luminosity of 35.6 fb -1 . Inclusive and differential cross-sections are measured for events containing a Z boson decaying into electrons or muons and produced in association with at least one or at least two b-jets with transverse momentum p T > 20 GeV and rapidity |y| < 2.5. Predictions from several Monte Carlo generators based on leading-order (LO) or next-to-leading-order (NLO) matrix elements interfaced with a parton-shower simulation and testing different flavour schemes for the choice of initial-state partons are compared with measured cross-sections. We find that the 5-flavour number scheme predictions at NLO accuracy agree better with data than 4-flavour number scheme ones. This is because the 4-flavour number scheme predictions underestimate data in events with at least one b-jet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for excited electrons singly produced in proton–proton collisions at $\sqrt{s}$ = 13 TeV with the ATLAS experiment at the LHC

A search for excited electrons produced in pp collisions at $\sqrt{s}$ = 13 TeV via a contact interaction $q\overline{q}$ → ee* is presented. The search uses 36.1 fb -1 of data collected in 2015 and 2016 by the ATLAS experiment at the Large Hadron Collider. Decays of the excited electron into an electron and a pair of quarks ($eq\overline{q}$) are targeted in final states with two electrons and two hadronic jets, and decays via a gauge interaction into a neutrino and a W boson ( νW ) are probed in final states with an electron, missing transverse momentum, and a large-radius jet consistent with a hadronically decaying W boson. No significant excess is observed over the expected backgrounds. Upper limits are calculated for the pp → ee* →$eeq\overline{q}$ and pp → ee* → eνW production cross sections as a function of the excited electron mass $m_{e*}$ at 95% confidence level. The limits are translated into lower bounds on the compositeness scale parameter Λ of the model as a function of $m_{e*}$. For $m_{e*}$ <0.5 TeV, the lower bound for Λ is 11 TeV. In the special case of $m_{e*}$=Λ, the values of $m_{e*}$< 4.8 TeV are excluded. The presented limits on Λ are more stringent than those obtained in previous searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resonance hairpin and Langmuir probe-assisted laser photodetachment measurements of the negative ion density in a pulsed dc magnetron discharge

The time-resolved negative oxygen ion density n{sub -} close to the center line in a reactive pulsed dc magnetron discharge (10 kHz and 50% duty cycle) has been determined for the first time using a combination of laser photodetachment and resonance hairpin probing. The discharge was operated at a power of 50 W in 70% argon and 30% oxygen gas mixtures at 1.3 Pa pressure. The results show that the O{sup -} density remains pretty constant during the driven phase of the discharge at values typically below 5x10{sup 14} m{sup -3}; however, in the off-time, the O{sup -} density grows reaching values several times those in the on-time. This leads to the negative ion fraction (or degree of electronegativity) {alpha}=n{sub -}/n{sub e} being higher in the off phase (maximum value {alpha}{approx}1) than in the on phase ({alpha}=0.05-0.3). The authors also see higher values of {alpha} at positions close to the magnetic null than in the more magnetized region of the plasma. This fractional increase in negative ion density during the off-phase is attributed to the enhanced dissociative electron attachment of highly excited oxygen molecules in the cooling plasma. The results show that close to the magnetic null the photodetached electron density decays quickly after the laser pulse, followed by a slow decay over a few microseconds governed by the negative ion temperature. However, in the magnetized regions of the plasma, this decay is more gradual. This is attributed to the different cross-field transport rates for electrons in these two regions. The resonance hairpin probe measurements of the photoelectron densities are compared directly to photoelectron currents obtained using a conventional Langmuir probe. There is good agreement in the general trends, particularly in the off-time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent results of the Majorana Demonstrator experiment

The Majorana Demonstrator is searching for neutrinoless double-beta decay in 76Ge with two modular arrays of natural and 76Ge-enriched germanium detectors. It is located at the 4850' level of Sanford Underground Research Facility in Lead, South Dakota, USA, and its total mass of germanium detectors is 44.1 kg, of which 29.7 kg is enriched. The analysis of the first 26 kg-yr of data provides an unprecedented energy resolution of 0.13% in the region of interest at 2039 keV and a background level of 15.4 ±2.0 counts/(FWHM t yr). It establishes the lower limit of the half-life of neutrinoless double beta decay as 2.7 1025 yr in 76Ge at 90% CL. This analysis will be summarized here with an emphasis on the energy determination.

López-Castaño, JM↗

Critical behavior of the van der Waals bonded ferromagnet Fe 3 - x GeTe 2

The critical properties of the single-crystalline van der Waals bonded ferromagnet Fe 3-x GeTe 2 were investigated by bulk dc magnetization around the paramagnetic to ferromagnetic (FM) phase transition. The Fe 3-x GeTe 2 single crystals grown by self-flux method with Fe deficiency x ≈ 0.36 exhibit bulk FM ordering below T c = 152 K. The Mössbauer spectroscopy was used to provide information on defects and local atomic environment in such crystals. Critical exponents β = 0.372(4) with a critical temperature T c = 151.25(5) K and γ = 1.265(15) with T c = 151.17(12) K are obtained by the Kouvel-Fisher method, whereas δ = 4.50 ( 1 ) is obtained by a critical isotherm analysis at T c = 151 K. These critical exponents obey the Widom scaling relation δ = 1 + γ / β , indicating self-consistency of the obtained values. With these critical exponents the isotherm M(H) curves below and above the critical temperatures collapse into two independent universal branches, obeying the single scaling equation m = f±(h), where m and h are renormalized magnetization and field, respectively. The exponents determined in this study are close to those calculated from the results of the renormalization group approach for a heuristic model of three-dimensional Heisenberg (d = 3,n = 3) spins coupled with the attractive long-range interactions between spins that decay as J(r) ≈ r -(3+σ) with σ = 1.89.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗