Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dead time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Half-life determination for {sup 108}Ag and {sup 110}Ag

In this work, the half-life of the short-lived silver radionuclides {sup 108}Ag and {sup 110}Ag were measured by following the activity of samples after they were irradiated in the IEA-R1 reactor. The results were then fitted using a non-paralizable dead time correction to the regular exponential decay and the individual half-life values obtained were then analyzed using both the Normalized Residuals and the Rajeval techniques, in order to reach the most exact and precise final values. To check the validity of dead-time correction, a second correction method was also employed by means of counting a long-lived {sup 60}Co radioactive source together with the samples as a livetime chronometer. The final half-live values obtained using both dead-time correction methods were in good agreement, showing that the correction was properly assessed. The results obtained are partially compatible with the literature values, but with a lower uncertainty, and allow a discussion on the last ENSDF compilations' values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trials and tribulations in the first three years in operation of the SSAMS for biomedical 14 C-AMS at LLNL

We report on the first several years of operation of our recently installed 250 kV SSAMS at LLNL, purchased to replace our 1-MV AMS system for the measurement of 14 C from labeled biochemical samples. We have modified the ion source region to improve ion output. Additionally, the SSAMS required significant software modifications to the data acquisition system in order to accurately measure 14 C at the high-count rates typically encountered with labeled biochemical samples. Here, we found that the data can be corrected assuming a nonparalyzable dead time response with a single event dead time of 6 µs. Since operation began, we have measured over 13,000 graphitic unknowns and over 1900 standards with an overall precision of 1.0%. We have optimized our system for the analysis of CO 2 gas samples. We compared aliquots of identical samples measured as solid graphite and as liquid drops. Excellent agreement was found between the two, although the average precision of the graphite targets was an order of magnitude better than the liquid drop analysis due to the much larger number of 14 C atoms available for measurement.

42 ENGINEERING↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

Data Compression in the NEXT-100 Data Acquisition System

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An analog study of a shock-position diffuser control on a supersonic turbojet engine

Shock position was assumed to be controlled by air bleed through a diffuser-exit bypass door operated by a second-order servomotor. Pressure disturbance resulting from changes in bypass-door position had whereas a disturbance in engine speed had a large effect on diffuser pressure and could impose severe requirements on diffuser control response. The controlled diffuser response improved with faster servomotor response and smaller diffuser dead time and lag. The effect of diffuser dead time on diffuser response was greater than the effect of diffuser lag.

Novik, David↗

ANALYTICAL LABORATORY AT IDAHO NATIONAL LABORATORY COUNTING EQUIPMENT STANDARDIZATION AND QUALITY CONTROL IMPROVEMENT

The Analytical Laboratory at Idaho National Laboratory (INL) is a growing program with an emphasis on providing high quality results to customers, and an increasing focus on independent research. The Analytical Laboratory Counting Group has a number of capabilities: six gamma-ray counters, one gamma-ray sample changer, four gas flow proportional counter drawers, an auto-changing gas flow proportional counter, two liquid scintillation counters, and an alpha spectroscopy system. Other capabilities within the Analytical Laboratory include quadrupole inductively coupled plasma mass spectrometry (ICP-MS), high resolution ICP-MS, multi-collector ICP-MS, ICP atomic emission spectrometry (ICP-AES), gas mass spectrometry, thermal ionization mass spectrometry (TIMS), several glove boxes and fume hoods for sample preparation, and six interconnected hot cells for sample receipt and dissolution. In order to position the Analytical Laboratory as a world-class research institution, the Counting Group has recently begun making improvements to its analytical techniques, calibrations, standardization, and quality control procedures. A large part of this effort is to increase the level of documentation of instrument work. One project is to re-calibrate all of the gamma systems with newly purchased standards. One of the changes made in the purchase of the new standards was to lower the total activity so that the dead time of the calibration would more closely match the dead time of typical samples. Similarly, another planned project is to use new standards to re-calibration the gas flow proportional counters. Additional work has focused on testing and improving alpha spectroscopy sample preparation techniques. Plutonium separations have been tested to improve tracer recovery and to verify the separation technique in the presence of typical sample matrices. A final planned area of improvements has focused on liquid scintillation counting. One difficulty the Counting Group has encountered in liquid scintillation counting is an inflated gross alpha count relative to other analysis methods in the presence of high gross beta activity. Ideas include investigating the impact of choice of scintillation cocktail, as well as the effects of sample dilution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Highly stable high-rate discriminator for nuclear counting

Pulse amplitude discriminator is specially designed for nuclear counting applications. At very high rates, the threshold is stable. The output-pulse width and the dead time change negligibly. The unit incorporates a provision for automatic dead-time correction.

English, J. J.↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking Simulations of the Compton Spectrometer and Imager with Calibrations

The Compton Spectrometer and Imager (COSI) is a balloon-borne 𝛾-ray (0.2-5 MeV) telescope designed to study astrophysical sources. COSI employs a compact Compton telescope design utilizing 12 high-purity germanium double-sided strip detectors and is inherently sensitive to polarization. In 2016, COSI was launched from Wanaka, New Zealand and completed a successful 46-day flight on NASA’s new Super Pressure Balloon. In order to perform imaging, spectral, and polarization analysis of the sources observed during the 2016 flight, we compute the detector response from well-benchmarked simulations. As required for accurate simulations of the instrument, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine which applies the intrinsic detector performance to Monte Carlo simulations. The simulated detector effects include energy, position, and timing resolution, thresholds, dead strips, charge sharing, charge loss, crosstalk, dead time, and detector trigger conditions. After including these effects, the simulations closely resemble the measurements, the standard analysis pipeline used for measurements can also be applied to the simulations, and the responses computed from the simulations are accurate. We have computed the systematic error that we must apply to measured fluxes at certain energies, which is 6.3% on a rage. Here we describe the detector effects engine and the benchmarking tests performed with calibrations.

Sleator, Clio C.↗

Design and performance testing of a novel far field Gamma system to assay radioactive waste in 400 and 200 litre drums - 15339

A Far Field Gamma ray Measurement system has been developed for measuring and assaying both 400 and 200 litre waste drums with a wide range of activity at nuclear power stations. These include radioactive waste drums with surface dose-rates of less than 2 mSv/h (200 mrem/h) and, at the higher range of activity, 400 litre drums with surface dose-rates of up to 50 mSv/h (5 rem/h). The assay system incorporates an electro-mechanically cooled high purity Germanium profile detector and advanced digital spectroscopic analysis electronics. A novel optimised conical-trapezoidal collimator has been incorporated to reduce the effect of the radioactive background in addition to the conventional detector lead shield with tin and copper graded lining to reduce the effect of lead X-rays. Two features have been incorporated to reduce detector dead time and maintain detector resolution when measuring high activity drums. The first is the inclusion of two automated tungsten filters of different thickness as an integral part of the detector collimator. The filters are used in conjunction with an automated rail system on which the detector platform is mounted. The detector can be positioned at different distances from the drum surface in order to reduce detector dead time. The deployment of the filters and the adjustment of the drum - detector position are automatically controlled based on a user defined dose-rate limit table. The data is provided by two Geiger-Muller dose-rate detectors, which are used to measure the drum surface dose-rate. This data is subsequently used to adjust the detector position and in cases of higher dose-rate deploy one or other of the tungsten filters. The drum rotation platform incorporates a load cell to determine drum weight and hence the drum density. This information is used to calculate an attenuation correction based on the assumption of uniform drum density and uniform distribution of activity within the drum. Where the waste drums have a more complicated and known regular internal structure, such as a small radioactive region surrounded by an annulus of shielding material, the analysis algorithms incorporated into the far field geometry and attenuation correction spectroscopic data analysis code are able to make a more accurate determination of drum activity than would be possible assuming a completely uniform drum. The detector energy and efficiency calibration is achieved using a point source with multiple gamma ray energy peaks. The response of the high purity Germanium detector is also modelled using the Monte Carlo Neutron Photon code and the model is benchmarked using the measured point source calibration data. The performance of the instrument has been determined for a range of uniform density matrix drums containing a set of Eu-152 line or rod sources located in re-entrant tubes positioned on an equal volume basis. When rotated, the test drums with volume distributed line sources simulate waste drums of different density each with a uniformly distributed radioactive source. The measurements have been validated using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Output statistics of laser anemometers in sparsely seeded flows

It is noted that until very recently, research on this topic concentrated on the particle arrival statistics and the influence of the optical parameters on them. Little attention has been paid to the influence of subsequent processing on the measurement statistics. There is also controversy over whether the effects of the particle statistics can be measured. It is shown here that some of the confusion derives from a lack of understanding of the experimental parameters that are to be controlled or known. A rigorous framework is presented for examining the measurement statistics of such systems. To provide examples, two problems are then addressed. The first has to do with a sample and hold processor, the second with what is called a saturable processor. The sample and hold processor converts the output to a continuous signal by holding the last reading until a new one is obtained. The saturable system is one where the maximum processable rate is arrived at by the dead time of some unit in the system. At high particle rates, the processed rate is determined through the dead time.

Edwards, R. V.↗

Experimental Investigation of Dynamic Relations in a 48-inch Ram-jet Engine

Engine dynamics were investigated for supercritical operation of the ram jet at Mach 2.75 over a range of simulated altitudes from 68,000 to 82,000 feet. Indicial-and frequency-response tests were conducted with fuel flow as the input variable. For a wide range of operating points, the response of static or total pressure to fuel flow consisted of a dead time followed by a response form that generally approximated a linear, first-order, lead-lag. The dead time varied significantly only with distance from the combustion zone. The rise ratio and the time constant of the lead-lag function were nearly independent of the pressure sensed.

Hurrell, Herbert G↗

Multispectral Gamma-Ray Analysis Using Clover Detectors with Application to Uranium Fission Product Analysis

A high-efficiency gamma-ray counting system has been built at Los Alamos National Laboratory for use in analyzing nuclear forensics samples. This system consists of two clover high-purity germanium detectors and is surrounded by a thallium-doped sodium iodide annulus. Special precautions have been taken to ensure the system has a low background. The system is connected to XIA Pixie-4 fast digitizers and collects data in list-mode. This work is split into two main parts. The first part describes the proper steps and techniques to initialize the settings of a detector system connected to fast digitizers in order to optimize the system for resolution and throughput. The various counting modes for this particular system are described in detail, including the benefits and drawbacks of each mode. Steps are then shown to characterize the system by obtaining efficiency curves for various counting modes and sample geometries. Because of the close counting geometry involved with this system, true coincidence summing factors must be calculated, and are done so in part by measuring the peak-to-total ratios of the system in its various counting modes across a wide energy range. The dead-time for the system can be complicated due to the multiple inputs of the system. Techniques for calculating the dead-time of multiple-detector systems are discussed. The second part of this work shows the system’s usefulness in analyzing nuclear forensics samples, specifically irradiated enriched uranium. Three fission product parent-daughter pairs of different lifetimes are analyzed over a course of six months. The activities of each nuclide are calculated at each time step. Age dating techniques using the parent-daughter pairs are discussed, as well as the detection limits of each nuclide for a range of sample ages. Finally, avenues for further research are presented, as well as potential sources of error or uncertainty for this work.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-speed electronics of the T0 detector for the ALICE experiment (CERN)

The design and special features of the main units of high-speed electronics for the trigger subsystem of the T0 detector of the ALICE experiment are considered. Its characteristic time resolution is 50 ps. The dead time does not exceed 25 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

An improved correction algorithm for number density measurements made with the forward scattering spectrometer probe

A correction factor to the number density measured by the Forward Scattering Spectrometer Probe (FSSP) which compensates for dead time and coincidence errors was determined by calculating the probabilities of, and the average number of particles in, the six possible types of dead time and coincidence events. These probabilities and averages were calculated by means of a probabilistic model based on Poisson statistics. A Monte Carlo computer simulation of the FSSP operation was also carried out and the number density correction factor was compared with the Monte Carlo data. For an actual number density of 2000/cu cm, it was found that the measured number density was of the order of 300/cu cm.

Lock, James A.↗

Advanced readout methods for superheated emulsion detectors

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 μm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗