Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

Optimal current profile control for enhanced repeatability of L-mode and H-mode discharges in DIII-D

In this work, model-based control techniques are used to obtain target current profiles in low-confinement-mode (L-mode) as well as high-confinement-mode (H-mode) DIII-D discharges. The control problem is formulated as a trajectory optimization problem to search for a feasible path from the expected initial condition to the desired target. The result comprises a sequence of feedforward (open-loop) control requests and a corresponding state evolution from the initial condition to the desired target. On top of this optimal feedforward control sequence a feedback (closed-loop) controller based on a linearized model and optimal control design techniques is added to track the desired state evolution. Furthermore, the effectiveness of the control approach is demonstrated with experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Continental-Scale Estimate of Soil Organic Carbon Change at NEON Sites and Their Environmental and Edaphic Controls

Current carbon cycle models focus on the effects of climate and land-use change on primary productivity and microbial-mineral dependent carbon turnover in the topsoil, while less attention has been paid to vertical soil processes and soil-dependent response to land-use change along the profile. In this study, a spatial-temporal analysis was used to estimate soil organic carbon (SOC) change in topsoil/A horizon and subsoil/B horizon at National Ecological Observatory Network (NEON) sites, USA over 30 years. To separate the effects of land-use, environmental, and edaphic factors on SOC change, space-for-time substitution was used in combination with the Continuous Change Detection and Classification algorithm and Structural Equation Modeling. Results showed that (a) under natural vegetation, Spodosols and Inceptisols found in the eastern NEON sites had substantial topsoil SOC accumulation (+0.4 to +1.2 Mg C ha –1 year –1 ), while Inceptisols and Andisols in the west had a comparable magnitude of topsoil SOC loss (–0.5 to –1.8 Mg C ha –1 year –1 ); (b) Mollisols and Alfisols in the Central Plains sites were susceptible to significant SOC loss under farming and grazing; (c) Runoff/erosion and leaching potential, vertical translocation, and mineral sorption were the most important factors controlling SOC variation across the NEON sites. Our work could be used to parameterize ecosystem models simulating SOC change.

54 ENVIRONMENTAL SCIENCES↗

Power flow control using distributed saturable reactors

A magnetic amplifier includes a saturable core having a plurality of legs. Control windings wound around separate legs are spaced apart from each other and connected in series in an anti-symmetric relation. The control windings are configured in such a way that a biasing magnetic flux arising from a control current flowing through one of the plurality of control windings is substantially equal to the biasing magnetic flux flowing into a second of the plurality of control windings. The flow of the control current through each of the plurality of control windings changes the reactance of the saturable core reactor by driving those portions of the saturable core that convey the biasing magnetic flux in the saturable core into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the saturable core.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precision control of multiple quantum cascade lasers for calibration systems

We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby, and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Modified Virtual Oscillator Based Operation of Grid Forming Converters with Single Voltage Sensor

Virtual oscillator based control architecture for grid forming converter with inner current control loop for additional objective accomplishments is proposed in this paper. In general, virtual oscillator is based on Lienard type of oscillator equation with a cubic nonlinearity. Virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized which is based upon Lyapunov energy function type control architecture due to its advantages. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling as presented in this paper. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain and case studies showing the successful production of low harmonic load voltages under nonideal loading condition along with other important results are presented in this paper.

dual second order generalized integrator↗

Light field–controlled PHz currents in intrinsic metals

Oriented electric currents in metals are routinely driven by applying an external electric potential. Although the response of electrons to the external electric fields occurs within attoseconds, conventional electronics do not use this speed potential. Ultrashort laser pulses with controlled shapes of electric fields that switch direction at petahertz frequencies open perspectives for driving currents in metals. Light field–driven currents were demonstrated in various media including dielectrics, semiconductors, and topological insulators. Now, our research question is whether we can drive and control orders of magnitude more charge carriers in metals enabling ultrafast switching with practically low-energy, picojoule-level pulses. Here, we demonstrate the interaction of light with nanometer-thick metallic layers, which leads to a generation of light field–controlled electric currents. We show that the implantation of metallic layers into a dielectric matrix leads to up to 40 times increase of the sensitivity in contrast to a bare dielectric, decreasing the intensity threshold for lightwave electronics.

Fehér, Beatrix [HUN-REN Wigner Research Centre for↗

On the Low Risk of SSR in Type III Wind Turbines Operating in Grid-Forming Control: Preprint

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Electrical resistance of the current collector controls lithium morphology

Abstract The electrodeposition of low surface area lithium is critical to successful adoption of lithium metal batteries. Here, we discover the dependence of lithium metal morphology on electrical resistance of substrates, enabling us to design an alternative strategy for controlling lithium morphology and improving electrochemical performance. By modifying the current collector with atomic layer deposited conductive (ZnO, SnO 2 ) and resistive (Al 2 O 3 ) nanofilms, we show that conductive films promote the formation of high surface area lithium deposits, whereas highly resistive films promote the formation of lithium clusters of low surface area. We reveal an electrodeposition mechanism in which radial diffusion of electroactive species is promoted on resistive substrates, resulting in lateral growth of large (150 µm in diameter) planar lithium deposits. Using resistive substrates, similar lithium morphologies are formed in three distinct classes of electrolytes, resulting in up to ten-fold improvement in battery performance. Ultimately, we report anode-free pouch cells using the Al 2 O 3 -modified copper that maintain 60 % of their initial discharge capacity after 100 cycles, displaying the benefits of resistive substrates for controlling lithium electrodeposition.

25 ENERGY STORAGE↗

System and method of adjusting the equilibrium temperature of an inductively-heated susceptor

A system for inductively heating a workpiece may include an induction coil, at least one susceptor face sheet, and a current controller coupled. The induction coil may be configured to conduct an alternating current and generate a magnetic field in response to the alternating current. The susceptor face sheet may be configured to have a workpiece positioned therewith. The susceptor face sheet may be formed of a ferromagnetic alloy having a Curie temperature and being inductively heatable to an equilibrium temperature approaching the Curie temperature in response to the magnetic field. The current controller may be coupled to the induction coil and may be configured to adjust the alternating current in a manner causing a change in at least one heating parameter of the susceptor face sheet.

42 ENGINEERING↗

System for adjusting the equilibrium temperature of an inductively-heated susceptor

A system for inductively heating a workpiece may include an induction coil, at least one susceptor face sheet, and a current controller coupled. The induction coil may be configured to conduct an alternating current and generate a magnetic field in response to the alternating current. The susceptor face sheet may be configured to have a workpiece positioned therewith. The susceptor face sheet may be formed of a ferromagnetic alloy having a Curie temperature and being inductively heatable to an equilibrium temperature approaching the Curie temperature in response to the magnetic field. The current controller may be coupled to the induction coil and may be configured to adjust the alternating current in a manner causing a change in at least one heating parameter of the susceptor face sheet.

36 MATERIALS SCIENCE↗

Optimal Structures for Voltage Controllers in Inverters: Preprint

Output voltage regulation is a primary performance objective in power electronics systems which are not supported by a stiff voltage source. In this paper, we pose an optimal voltage control problem for ac inverter systems and study the structure of the resulting feedback laws. Here, it is demonstrated that the solution to the optimal voltage regulation control problem exhibits an inner current-controller structure even though there are no explicit objectives on tracking current which are targeted. Furthermore, the outer-loop voltage control and inner-loop current control structure is insensitive to the weighting transfer functions used in the optimal control problem. Although the inner-outer structure has been used in prior works, the optimal nature of such a structure was not known. In deriving the optimal controller, we also present a systematic design framework which is cognizant of the physical properties of inverters. Case studies are used to study the optimal controller and its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Modified Virtual Oscillator-Based Operation of Grid-Forming Converters with Single Voltage Sensor: Preprint

This paper proposes a virtual oscillator-based control architecture for a grid-forming converter with an inner current control loop. In general, the virtual oscillator is based on a Lienard type of oscillator equation with a cubic nonlinearity. A virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid-forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized that is based on the Lyapunov energy function type control architecture. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain. This paper also presents case studies showing the successful production of low harmonic load voltages under nonideal loading conditions, along with other important results.

dual second order generalized integrator↗

Magnetic rogue wave in a perpendicular anisotropic ferromagnetic nanowire with spin-transfer torque

We present the current controlled motion of a dynamic soliton embedded in spin wave background in ferromagnetic nanowire. With the stronger breather character we get the novel magnetic rogue wave and clarify its formation mechanism. The generation of magnetic rogue wave mainly arises from the accumulation of energy and magnons toward to its central part. We also observe that the spin-polarized current can control the exchange rate of magnons between the envelope soliton and the background, and the critical current condition is obtained analytically. Even more interesting is that the spin-transfer torque plays the completely opposite role for the cases below and above the critical value. - Highlights: Black-Right-Pointing-Pointer We get the current controlled motion of a dynamic soliton embedded in spin wave background. Black-Right-Pointing-Pointer We get the novel magnetic rogue wave and clarify its formation mechanism. Black-Right-Pointing-Pointer The generation of magnetic rogue wave arises from the accumulation of energy and magnons. Black-Right-Pointing-Pointer The spin-polarized current controls exchange rate of magnons between the envelope soliton and the background. Black-Right-Pointing-Pointer The spin-transfer torque plays the completely opposite role below and above the critical value.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗