At least 91 records · Page 5

Shuttle cryogenic supply system optimization study. Volume 4: Cryogenic cooling in environmental control systems

An analysis of cryogenic fluid cooling in the environmental control system of the space shuttle was conducted. The technique for treating the cryogenic fluid storage and supply tanks and subsystems as integrated systems was developed. It was concluded that a basic incompatibility exists between the heat generated and the cryogen usage rate and cryogens cannot be used to absorb the generated heat. The use of radiators and accumulators to provide additional cooling capability is recommended.

Source record↗

Advanced Ground Systems Maintenance Cryogenics Test Lab Control System Upgrade Project

This project will outfit the Simulated Propellant Loading System (SPLS) at KSC's Cryogenics Test Laboratory with a new programmable logic control system. The control system upgrade enables the Advanced Ground Systems Maintenace Element Integration Team and other users of the SPLS to conduct testing in a controls environment similar to that used at the launch pad.

Technology Portfolio System↗

Fluid management system for a zero gravity cryogenic storage system

The fluid management system comprises a mixing/recirculation system including an external recirculation pump for receiving fluid from a zero gravity storage system and returning an output flow of the fluid to the storage system. An internal axial spray injection system is provided for receiving a portion of the output flow from the recirculation pump. The spray injection system thermally de-stratifies liquid and gaseous cryogenic fluid stored in the storage system.

Lak, Tibor I.↗

Cryogenic optical systems and instruments; Proceedings of the Meeting, San Diego, CA, August 23, 24, 1984

Systems considerations for the Shuttle Infrared Telescope Facility (SIRTF) are discussed, taking into account SIRTF telescope engineering and trade studies, implications of orbital inclination for SIRTF design and operations, the approaching of the natural background limit with the SIRTF, a long life feasibility study for SIRTF, and the impact of chopping on image quality in the SIRTF telescope. Cryogenic systems and coolers for space missions are considered, giving attention to the Infrared Astronomical Satellite (IRAS) hardware flight performance, the design of the superfluid helium dewar for the Cosmic Background Explorer (COBE), Infrared Telescope (IRT) system cryogenic performance, the solidification of a cryogen by pumping, the production of superfluid helium using a Joule-Thomson Expander, and open cycle He-3 cooling to 0.18 K for space operation. Other topics explored are related to cryogenic optical instruments, facilities, and components, and to supporting technology for cryogenic infrared telescopes in space.

Melugin, R. K.↗

Advanced long term cryogenic storage systems

Long term, cryogenic fluid storage facilities will be required to support future space programs such as the space-based Orbital Transfer Vehicle (OTV), Telescopes, and Laser Systems. An orbital liquid oxygen/liquid hydrogen storage system with an initial capacity of approximately 200,000 lb will be required. The storage facility tank design must have the capability of fluid acquisition in microgravity and limit cryogen boiloff due to environmental heating. Cryogenic boiloff management features, minimizing Earth-to-orbit transportation costs, will include advanced thick multilayer insulation/integrated vapor cooled shield concepts, low conductance support structures, and refrigeration/reliquefaction systems. Contracted study efforts are under way to develop storage system designs, technology plans, test article hardware designs, and develop plans for ground/flight testing.

Brown, Norman S.↗

Design of propellant acquisition systems for advanced cryogenic space propulsion systems

This paper presents results of work conducted to expand the technology base and evolve practical propellant surface tension acquisition system designs for future cryogenic space vehicles. Surface tension screen device channel flow analysis and supporting tests showed that reasonable mesh sizes could provide the required retention performance. Integrated subsystem studies and development showed that practical and effective screen surface tension acquisition devices could be designed for typical applications, but that other interfacing feed subsystems are often constrained by the design of the particular acquisition device. These constraints may dominate the total feed system performance.

Burge, G. W.↗

Shuttle cryogenic supply system optimization study. Volume 5A-1: Users manual for math models

The Integrated Math Model for Cryogenic Systems is a flexible, broadly applicable systems parametric analysis tool. The program will effectively accommodate systems of considerable complexity involving large numbers of performance dependent variables such as are found in the individual and integrated cryogen systems. Basically, the program logic structure pursues an orderly progression path through any given system in much the same fashion as is employed for manual systems analysis. The system configuration schematic is converted to an alpha-numeric formatted configuration data table input starting with the cryogen consumer and identifying all components, such as lines, fittings, and valves, each in its proper order and ending with the cryogen supply source assembly. Then, for each of the constituent component assemblies, such as gas generators, turbo machinery, heat exchangers, and accumulators, the performance requirements are assembled in input data tabulations. Systems operating constraints and duty cycle definitions are further added as input data coded to the configuration operating sequence.

Source record↗

Cryogenic Insulation Systems

The results of a comparative study of cryogenic insulation systems performed are presented. The key aspects of thermal insulation relative to cryogenic system design, testing, manufacturing, and maintenance are discussed. An overview of insulation development from an energy conservation perspective is given. Conventional insulation materials for cryogenic applications provide three levels of thermal conductivity. Actual thermal performance of standard multilayer insulation (MLI) is several times less than laboratory performance and often 10 times worse than ideal performance. The cost-effectiveness of the insulation system depends on thermal performance; flexibility and durability; ease of use in handling, installation, and maintenance; and overall cost including operations, maintenance, and life cycle. Results of comprehensive testing of both conventional and novel materials such as aerogel composites using cryostat boil-off methods are given. The development of efficient, robust cryogenic insulation systems that operate at a soft vacuum level is the primary focus of this paper.

Augustynowicz, S. D.↗