Improving adsorption cryocoolers by multi-stage compression and reducing void volume

It is shown that the performance of gas adsorption cryocoolers is greatly improved by using adsorbents with low void volume within and between individual adsorbent particles (reducing void volumes in plumbing lines), and by compressing the working fluid in more than one stage. Refrigerator specific power requirements and compressor volumetric efficiencies are obtained in terms of adsorbent and plumbing line void volumes and operating pressures for various charcoal adsorbents using an analytical model. Performance optimization curves for 117.5 and 80 K charcoal/nitrogen adsorption cryocoolers are given for both single stage and multistage compressor systems, and compressing the nitrogen in two stages is shown to lower the specific power requirements by 18 percent for the 117.5 K system.

Bard, S.

Diaphragm Stirling cryocooler developments

This paper reports on the status of several ongoing development programs aimed at the demonstration of diaphragm Stirling cycle cryocooler performance. Key attributes of this technology focus on long reliable operating life and excellent efficiency, making it a candidate for cooling of satellite-borne long wavelength sensors for astrophysics and earth observing missions. Three programs are described, each leading to system or component test hardware: a 2 W 65 K single-stage Standard Spacecraft Cryocooler, a 300 mW 30 K two-stage cooler and a 200 mW 4-20 K single-stage cooler. Design features are described, and breadboard experimental data are presented.

Stacy, W. D.

Calorimetric thermal-vacuum performance characterization of the BAe 80 K space cryocooler

A comprehensive characterization program is underway at JPL to generate test data on long-life, miniature Stirling-cycle cryocoolers for space application. The key focus of this paper is on the thermal performance of the British Aerospace (BAe) 80 K split-Stirling-cycle cryocooler as measured in a unique calorimetric thermal-vacuum test chamber that accurately simulates the heat-transfer interfaces of space. Two separate cooling fluid loops provide precise individual control of the compressor and displacer heatsink temperatures. In addition, heatflow transducers enable calorimetric measurements of the heat rejected separately by the compressor and displacer. Cooler thermal performance has been mapped for coldtip temperatures ranging from below 45 K to above 150 K, for heatsink temperatures ranging from 280 K to 320 K, and for a wide variety of operational variables including compressor-displacer phase, compressor-displacer stroke, drive frequency, and piston-displacer dc offset.

Kotsubo, V. Y.

Thermal Strap Increases Cryocooling Efficiency

Report discusses concept for decreasing compressor power consumed by spacecraft mechanical cryocooler providing 0.5 W of refrigeration at temperature of 61 K at tip of cold finger. Involves connecting thermal strap between radiator or other heat sink at intermediate temperature and stiffening ring located on cold finger about one-third way from base to tip and attains temperature of about 250 K during normal operation. Depending upon specific design, electrical power consumed by mechanical cryocooler reduced by half.

Ross, Ronald G., Jr.

A Low Temperature, Reverse Brayton Cryocooler

This status report covers the fifty-second month of a project to develop a low temperature, reverse-Brayton cryocooler using turbomachines. This program consists of a Basic Phase and four Option Phases. Each of the Phases is directed to a particular load/temperature combination. The technology and fundamental design features of the components used in these systems are related but differ somewhat in size, speed, and some details in physical geometry. Each of the Phases can be carried out independently of the others, except that all of the Phases rely on the technology developed and demonstrated during the Basic Phase. The Basic Phase includes the demonstration of a critical component and the production of a prototype model cryocooler. The critical technology demonstration will be the test of a small turboalternator over a range of conditions at temperatures down to 6 K. These tests will provide design verification data useful for the further design of the other coolers. The prototype model cooler will be designed to provide at least 5 mW of cooling at 6 K. The heat rejection temperature for this requirement is 220 K or greater. The input power to the system at these conditions is to be less than 60 W.

Swift, Walter L.

On-Orbit Performance of the RHESSI Cryocooler

The Ramaty High Energy Solar Spectroscopic Imager (RHESSI) spacecraft was launched on February 5,2002. With more than a year of operation on-orbit, its Sunpower M77 cryocooler continues to maintain the array of nine germanium detectors at 7% Trends have begun to emerge in cryocooler power and vibration, suggesting that the cooler's operating point is slowly changing. Possible causes are identified and discussed.

Boyle, Robert F.

Thermal Imaging Applied to Cryocrystallography: Cryocooling and Beam Heating (Part I)

Thermal imaging provides a non-invasive method to study both the cryocooling process and the heating due to the X-ray beam interaction with a sample. The method has been used successfully to image cryocooling in a number of experimental situations, i.e. cooling as a function of sample volume and as a function of cryostream orientation. Although there are experimental limitations to the method, it has proved a powerful technique to aid cryocrystallography development. Due to the rapid spatial temperature information provided about the sample it is also a powerful tool in the testing of mathematical models. Recently thermal imaging has been used to measure the temperature distribution on both a model and typical crystal samples illuminated with an X-ray beam produced by an undulator. A brief overview of thermal imaging and previous results will be presented. In addition, a detailed description of the calibration and experimental aspects of the beam heating measurements will be described. This will complement the following talk on the mathematical modeling and analysis of the results.

Snell, Edward

Spacecraft Cryocooler Thermal Integration

Spacecraft instruments requiring cryocoolers to cool infrared focal plane arrays have increased complexity in the overall design with respect to power and thermal management. The use of mechanical cryocoolers can drive spacecraft solar array and thermal radiator dimensions, and spacecraft designers must be prudent in keeping these dimensions feasible.

Infrared focal plane Launch Lift Capabilities

Cryocooler Electromagnetic Compatibility

The Jet Propulsion Laboratory, under joint Ballistic Missile and Defense Organization/Air Force and NASA/Eos Atmospheric Infrared Sounder sponsorship, is conducting extensive space cryocooler characterization to provide a reliable and accurate data base on cryocooler performance for use by the space community.

detector

Cryocooler Coldfinger Heat Interceptor

Spacecraft instruments requiring cryocoolers in their design struggle to keep overall power requirements in line with feasible solar array dimensions and launch vehicle lift capacities. Intermediate temperature (150 K to 200 K) radiators to cool radiation shields or optics on spacecraft instruments provide an as yet untapped resource for reducing the cryocooler power requirments.

Cryogenic Temperature

Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

angular dependency

Automated Cryocooler Monitor and Control System Software

This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

Britchcliffe, Michael J.

TIRS Cryocooler: Spacecraft Integration and Test and Early Flight Data

The Thermal Infrared Sensor (TIRS) is an instrument on Landsat 8, launched in February 2013. The focal plane is cooled by a two-stage Ball Aerospace Stirling cycle cryocooler, with a coldfinger operating at 40K. This paper describes events during the spacecraft integration and test program, and results from early orbit operation of the cryocooler.

Boyle, R.

Development of a Turn Key Cryogenic Cooling Module for Space Flight Based on a Commercial Cryocooler

Commercial cryocoolers have significant price and lead time advantages over coolers built exclusively for the space market, but there are many challenges that must be overcome before using a COTS cooler for flight. The initial cost advantage is significantly narrowed by the cost of adapting the COTS cooler for flight. JPL is developing a “turnkey” cryogenic cooling solution based on a commercial cryocooler with the intention that it can become a standard product. The goal is to develop a complete, fully redundant cryogenic cooling solution based on the Thales 9310. The system includes the cooler, brackets to provide mounting and cooling, supporting structures, vibration isolation, thermal straps, thermal switches, and drive electronics. This paper discusses qualification of the various components for flight, including launch vibration and thermal performance testing, as well as a full up testing of the completed assembly.

Ramsey, Perry G.

Development of a Turn Key Cryogenic Cooling Module for Space Flight Based on a Commercial Cryocooler

Commercial cryocoolers have significant price and lead time advantages over coolers built exclusively for the space market, but there are many challenges that must be overcome before using a COTS cooler for flight. The initial cost advantage is significantly narrowed by the cost of adapting the COTS cooler for flight. JPL is developing a “turn key” cryogenic cooling solution based on a commercial cryocooler with the intention that it can become a standard product. The goal is to develop a complete, fully redundant cryogenic cooling solution based on the Thales 9310. The system includes the cooler, brackets to provide mounting and cooling, supporting structures, vibration isolation, thermal straps, thermal switches, and drive electronics. This paper discusses qualification of the various components for flight, including launch vibration and thermal performance testing, as well as a full up testing of the completed assembly.

Ramsey, Perry G.

NASA Team Develops a Test Article to Demonstrate “Zero Boil-Off” Storage of Liquid Hydrogen via Cryocoolers and a Two-Stage Cooling Approach

Funded by NASA’s Technology Demonstration Mission Program and managed by the Cryogenic Fluid Management Portfolio Project, a NASA team is developing a test article to demonstrate the “zero boil-off” storage of liquid hydrogen using active cooling (cryocoolers) and a two-stage cooling approach. The current state of the art for storage of liquid hydrogen on-orbit is on the order of hours while future missions may require storage for months or even years. To enable such extended storage durations, “near zero” propellant loss, or “zero boil-off”, must be achieved. This may be accomplished with the implementation of “near zero” leakage components, a high performing suite of passive technologies to minimize the environmental heat loads, and active cooling via cryocoolers to intercept and remove heat from the propellant tanks and associated structure. Of course, with any cryogenic vehicle and mission, a mass and power trade should be conducted to determine if it is indeed feasible to carry the additional dry mass associated with active cooling, or if one could simply carry additional propellants to accommodate propellant loss which is typically not an option for a long duration mission.

Hydrogen Storage

Cryocooler Coldfinger Heat Interceptor

Spacecraft instruments requiring cryocoolers in their design struggle to keep overall power requirements in line with feasible solar array dimensions.

cryocooler coldfinger heat interceptor radiators t