Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Association between media coverage and prevalence of idiopathic environmental intolerance attributed to electromagnetic field in Taiwan

Highlights: • The prevalence rate of IEI-EMF in Taiwan declined form 13.3% in 2007 to 4.6% in 2012. • Residents in Taiwan had increasing exposure to EMF related to mobile phone use during the same period of time. • Media coverage of EMF related issues had the similar trend with the decreased IEI-EMF prevalence rate. • Most media coverage conveyed information on the negative health impacts of EMF. • Risk communications seem to be more effective than precautionary measures in coping with the public fears about EMF. Idiopathic environmental intolerance attributed to electromagnetic fields (IEI-EMF) describes symptoms sufferers attribute to exposure to electromagnetic fields (EMF). In Taiwan, the prevalence rate of IEI-EMF was 13.3% in 2007, but a survey using the same method found the rate declined to 4.6% in 2012. Because media reports may encourage readers to attribute their symptoms to EMF, the change might be related to media coverage. We searched articles indexed in the largest newspaper database in Taiwan to evaluate the association between media coverage and the prevalence of IEI-EMF. We also assessed the effects of other potential affecting factors. The number of newspaper articles related to EMF and IEI-EMF increased from 2005 to 2007 and then has been decreasing until 2012, which is compatible with the change in the prevalence of IEI-EMF. However, from 2007 to 2012, the other potential affecting factors such as density of mobile phone base stations, number of mobile phone users, total mobile phone calling time, and number of text messages sent through mobile phones all increased in Taiwan. This finding indicated a positive association between media coverage and the prevalence of IEI-EMF in Taiwan, which might also be true in other countries.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Proton Therapy Coverage for Prostate Cancer Treatment

Purpose: To determine the impact of prostate motion on dose coverage in proton therapy. Methods and Materials: A total of 120 prostate positions were analyzed on 10 treatment plans for 10 prostate patients treated using our low-risk proton therapy prostate protocol (University of Florida Proton Therapy Institute 001). Computed tomography and magnetic resonance imaging T{sub 2}-weighted turbo spin-echo scans were registered for all cases. The planning target volume included the prostate with a 5-mm axial and 8-mm superoinferior expansion. The prostate was repositioned using 5- and 10-mm one-dimensional vectors and 10-mm multidimensional vectors (Points A-D). The beam was realigned for the 5- and 10-mm displacements. The prescription dose was 78 Gy equivalent (GE). Results: The mean percentage of rectum receiving 70 Gy (V{sub 70}) was 7.9%, the bladder V{sub 70} was 14.0%, and the femoral head/neck V{sub 50} was 0.1%, and the mean pelvic dose was 4.6 GE. The percentage of prostate receiving 78 Gy (V{sub 78}) with the 5-mm movements changed by -0.2% (range, 0.006-0.5%, p > 0.7). However, the prostate V{sub 78} after a 10-mm displacement changed significantly (p < 0.003) with different movements: 3.4% (superior), -5.6% (inferior), and -10.2% (posterior). The corresponding minimal doses were also reduced: 4.5 GE, -4.7 GE, and -11.7 GE (p {<=} 0.003). For displacement points A-D, the clinical target volume V{sub 78} coverage had a large and significant reduction of 17.4% (range, 13.5-17.4%, p < 0.001) in V{sub 78} coverage of the clinical target volume. The minimal prostate dose was reduced 33% (25.8 GE), on average, for Points A-D. The prostate minimal dose improved from 69.3 GE to 78.2 GE (p < 0.001) with realignment for 10-mm movements. Conclusion: The good dose coverage and low normal doses achieved for the initial plan was maintained with movements of {<=}5 mm. Beam realignment improved coverage for 10-mm displacements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Capturing the Coverage Dependence of Aromatics’ Adsorption through Mean-Field Models

To capture the dominant interactions (surface-mediated and through-space steric) in catalytic hydrodeoxygenation systems, coverage-dependent mean-field models of aromatic adsorption are developed on Pt(111) and Ru(0001). We derive three key insights from this work: (1) we can universally apply mean-field models to capture the coverage-dependent behavior of oxygenated aromatics on transition metal surfaces, (2) we can deconvolute surface-mediated and throughspace steric interactions from the mean-field model, and (3) we can develop relatively accurate models that predict the adsorption energy of aromatics on transition metal surfaces for the full coverage range using the work function at lowest modeled coverage. In conclusion, our approach enables the rapid prediction of coverage-dependent behavior of oxygenated aromatics on transition metal surfaces, reducing the computational cost associated with these studies by an order of magnitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relationship between the surface coverage of spectator species and the rate of electrocatalytic reactions.

Relationships between the surface coverage of spectator (blocking) species and the rate of the hydrogen oxidation reaction (HOR), the oxygen reduction reaction (ORR), and the bulk oxidation of dissolved CO on Pt(100) and Pt(111) single crystals in acidic electrolytes has been probed by cyclic voltammetry, in situ surface X-ray scattering (SXS), and ex situ scanning tunneling microscopy (STM) techniques. It is shown that the surface coverage by spectator species during the HOR and the ORR are the same as for the corresponding coverage obtained in the inert (Ar-saturated) environment. This observation is consistent with the proposition that the availability of active sites for H{sub 2} and O{sub 2} is determined almost entirely by the coverage of adsorbates from the supporting electrolyte and not by the active intermediates. Related electrochemical-SXS studies undertaken for bulk CO oxidation reveal that the maximum rate above the ignition potential is reached on a surface that is covered by {approx}90% of an ordered CO adlayer. The nature of the active sites in this case is determined by a combination of electrochemical and STM results. It is found that the active sites in this potential region are steps, which appear to be active sites for OH adsorption. To get insight into the relationship between the diffusion-limiting current and the surface coverage by the inactive CO adlayer, we introduce the concept of a partially blocked electrode surface with active and inactive areas. On the basis of the calculations and experimental results, it is proposed that the active sites for given electrochemical reactions on Pt electrodes are arrays of adsorbate-free nanoscale patches embedded in an inactive adlayer of nonreactive molecular species.

08 HYDROGEN↗

Two-Photon Photoemission Study of the Coverage-Dependent Electronic Structure of Chemisorbed Alkali Atoms on a Ag(111) Surface

We report a systematic investigation of the electronic structure of chemisorbed alkali atoms (Li-Cs) on a Ag(111) surface by two-photon photoemission spectroscopy. Angle-resolved two-photon photoemission spectra are obtained for 0-0.1 monolayer coverage of alkali atoms. The interfacial electronic structure as a function of periodic properties and the coverage of alkali atoms is observed and interpreted assuming ionic adsorbate/substrate interaction. The energy of the alkali atom σ-resonance at the limit of zero coverage is primarily determined by the image charge interaction, whereas at finite alkali atom coverages, it follows the formation of a dipolar surface field. The coverage- and angle-dependent two-photon photoemission spectra provide information on the photoinduced charge-transfer excitation of adsorbates on metal surfaces. This work complements the previous work on alkali/ Cu(111) chemisorption

Environmental Molecular Sciences Laboratory↗

Determination of Absolute Coverages for Small Aliphatic Alcohols on TiO2(110)

The absolute coverages of water and small aliphatic alcohols (C1-C4) were determined on TiO{sub 2}(110) using a combination of temperature programmed desorption and liquid nitrogen cooled quartz crystal microbalance measurements. The absolute saturation coverages of water on Ti{sup 4+} and bridging oxygen (O{sub b}) sites are found to be equal to 1 monolayer with respect to the number of Ti{sup 4+} and/or O{sub b} sites (1 ML {triple_bond} 5.2 x 10{sup 14} cm{sup 2}) in a good agreement with prior studies. The saturation coverages of primary alcohols on Ti{sup 4+} sites are found to be approximately constant and equal to 0.77 ML. This indicates that the increasing length of the alkyl chains does not contribute to additional steric hindrance. Additional steric hindrance is observed with increasing number of chains as shown for secondary alcohols and tertiary t-butanol where the coverage decreases to 0.62 and 0.44 ML, respectively. On O{sub b} rows, a monotonic decrease of the alcohol coverage is observed for both increasing length of the alkyl chains and the chain number.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Finding gaps in the national electric vehicle charging station coverage of the United States

Abstract The United States federal government has invested $7.5 billion into charging infrastructure, including the National Electric Vehicle Infrastructure Program, to build fast charging stations along designated highways for long-distance car travel. We develop a consecutive coverage metric to compute the percent of United States roads (traffic-weighted) that are consecutively accessible within 500 miles of each county. We answer (1) what the state of consecutive coverage is in each county and (2) what the increase in coverage is when designated highways receive fast chargers. In 2023, 10% of counties had at least 75% minimum viable coverage. We find that if all designated highways receive fast-charging stations, 94% of United States counties will reach at least 75% fast charger coverage. However, the remaining counties are rural. This demonstrates that federal funding for fast chargers will help connect most—but not all—counties to the national network of continuously accessible charging stations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural and electronic properties of AlN(0001) surface under partial N coverage as determined by ab initio approach

Properties of bare and nitrogen-covered Al-terminated AlN(0001) surface were determined using density functional theory (DFT) calculations. At a low nitrogen coverage, the Fermi level is pinned by Al broken bond states located below conduction band minimum. Adsorption of nitrogen is dissociative with an energy gain of 6.05 eV/molecule at a H3 site creating an overlap with states of three neighboring Al surface atoms. During this adsorption, electrons are transferred from Al broken bond to topmost N adatom states. Accompanying charge transfer depends on the Fermi level. In accordance with electron counting rule (ECR), the DFT results confirm the Fermi level is not pinned at the critical value of nitrogen coverage θ{sub N}(1) = 1/4 monolayer (ML), but it is shifted from an Al-broken bond state to Np{sub z} state. The equilibrium thermodynamic potential of nitrogen in vapor depends drastically on the Fermi level pinning being shifted by about 4 eV for an ECR state at 1/4 ML coverage. For coverage above 1/4 ML, adsorption is molecular with an energy gain of 1.5 eV at a skewed on-top position above an Al surface atom. Electronic states of the admolecule are occupied as in the free molecule, no electron transfer occurs and adsorption of a N{sub 2} molecule does not depend on the Fermi level. The equilibrium pressure of molecular nitrogen above an AlN(0001) surface depends critically on the Fermi level position, being very low and very high for low and high coverage, respectively. From this fact, one can conclude that at typical growth conditions, the Fermi level is not pinned, and the adsorption and incorporation of impurities depend on the position of Fermi level in the bulk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Expanding proteome coverage with orthogonal-specificity α-Lytic proteases

Bottom-up proteomics studies traditionally involve proteome digestion with a single protease, trypsin. However, trypsin alone does not generate peptides that encompass the entire proteome. Alternative proteases have been explored, but most have specificity for charged amino acid side chains. Therefore, additional proteases that improve proteome coverage by cleavage at sequences complimentary to trypsin may increase proteome coverage. We demonstrate the novel application of two proteases for bottom-up proteomics: wild type alpha-lytic protease (WaLP), and an active site mutant of WaLP, M190A alpha-lytic protease (MaLP). We assess several relevant factors including MS/MS fragmentation, peptide length, peptide yield, and protease specificity. By combining data from separate digestions with trypsin, LysC, WaLP, and MaLP, proteome coverage was increased 101% compared to trypsin digestion alone. To demonstrate how the gained sequence coverage can access additional PTM information, we show identification of a number of novel phosphorylation sites in the S. pombe proteome and include an illustrative example from the protein MPD2, wherein two novel sites are identified, one in a tryptic peptide too short to identify and the other in a sequence devoid of tryptic sites. The specificity of WaLP and MaLP for aliphatic amino acid side chains was particularly valuable for coverage of membrane protein sequences, which increased 350% when the data from trypsin, LysC, WaLP, and MaLP were combined.

Environmental Molecular Sciences Laboratory↗

Effect of cold cap coverage and emissivity on the plenum temperature in a pilot-scale waste vitrification melter

Integrated computational fluid dynamics (CFD) models are being developed to model the complex physics occurring within the high-level waste melter for vitrification of legacy tank waste at the Hanford site. Here, we present a validation of the integrated CFD model by using data from two experimental runs in a pilot-scale melter. While the model uses several simplifying assumptions (such as constant heat sinks from a cooling jacket and inleakage of ambient air, steady state feed-to-batch conversion heat, and a cold cap model with a simplified shape), it closely predicts the molten glass (1150°C and 1175°C) and plenum temperatures (550°C) obtained from thermocouples during two pilot-scale tests, with an average cold cap coverage of 80%. Additional simulations were performed to explore the sensitivity of the predicted plenum temperatures to variations in cold cap coverage (fraction of melt surface covered by the glass batch) and batch emissivity. The plenum temperature was found to be in the range of 606°C when cold cap coverage decreased from 95% to 70%. Cold cap emissivity had a smaller effect, increasing the plenum temperature by as much as 179°C when cold cap emissivity increased from 0.2 to 0.8. Maintaining a high cold cap coverage without overfeeding is important for a sustained melter operation with high glass throughput. This work provides a tool for achieving that goal in terms of correlating the plenum temperature with the cold cap coverage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-AB-BRB-00: New Methods to Ensure Target Coverage

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRB-03: Coverage-Based Treatment Planning to Accommodate Organ Deformable Motions and Contouring Uncertainties for Prostate Treatment

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-I-03: Correction of Intra-Fractional Set-Up Errors and Target Coverage Based On Cone-Beam Computed Tomography for Cervical Cancer Patients

Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed. Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.

60 APPLIED LIFE SCIENCES↗

Code Coverage Status of the ARC code GAMSRC

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. GAMSOR serves as procedure to obtain the neutron and gamma power distribution information in the ARC code system. GAMSOR is a specially modified version of DIF3D (dif3d.x becomes dif3d_gamsor.x). After some work, it was determined that carrying out software on GAMSOR was impractical and would not fit well with commercial grade dedication. GAMSRC was written in the last decade to replace GAMSOR such that the user can rely soley upon the verified DIF3D (dif3d.x) code and GAMSRC to obtain the neutron and gamma power distribution information. GAMSRC is also fully verified and ready for commercial grade dedication. In the coming years, GAMSOR will be deprecated and GAMSRC will fully take over in the ARC code system. This document identifies the set of test problems used to assess the code coverage for GAMSRC. The goal is to document what parts of the existing GAMSRC code are touched by the set of test problems and which are not. The code coverage analysis of GAMSRC was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of GAMSRC. The code coverage tables are given for each submodule of GAMSRC. Because GAMSRC links to modules in DIF3D, some details on coverage changes to the DIF3D lined files is provided. As will be seen, most of the uncovered parts/files can be ignored because they are either for error message and debugging output or obviously not needed by GAMSRC today.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Coverage Status of the ARC Code DASSH-F

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. DASSH-F serves as a steady state thermal hydraulic capability within the ARC system and replaces the SE2-ANL software that preceded it. This document identifies the set of test problems used to assess the code coverage for DASSH-F. The goal is to document what parts of the existing DASSH-F code are touched by the set of test problems and which are not. Because the verification work remains to be done on DASSH-F, one can assume that most of these issues will be resolved as part of that work. The code coverage analysis of DASSH-F was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of DASSH-F. The code coverage tables are given for each submodule of DASSH-F. Because DASSH-F links to modules in DIF3D, some details on coverage changes to the DIF3D linked files is provided. As will be seen, most of the uncovered parts/files can be ignored because they are either for error message and debugging output or obviously not needed by DASSH-F today. Seven features of the DASSH-F code were identified to not be covered by the existing testing suite and thus additional verification test problems are suggested to fully cover these sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of coverage on the reliability of a fault tolerant computer

A mathematical reliability model is established for a reconfigurable fault tolerant avionic computer system utilizing state-of-the-art computers. System reliability is studied in light of the coverage probabilities associated with the first and second independent hardware failures. Coverage models are presented as a function of detection, isolation, and recovery probabilities. Upper and lower bonds are established for the coverage probabilities and the method for computing values for the coverage probabilities is investigated. Further, an architectural variation is proposed which is shown to enhance coverage.

Bavuso, S. J.↗