Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrosion monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design and Materials of Reference Electrodes for Radioactive Waste Tank Service – A Literature Review

The Hanford site stores approximately 55 million gallons of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground, carbon steel storage tanks, 149 of these are single shell tanks (SSTs) and 28 of these are double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The DSTs have been in service for 38 to 56 years and current plans indicate that WTP operations will be completed in 2075. Thus, the tanks will need to remain in service far beyond the initial 40-year life expectancy. For life extension of the tanks, effective corrosion control practices must remain in force. This effort includes direct measurements of the extent of corrosion (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical-Sensing Cables Detect Potential Threats

Intelligent Optical Systems Inc. (IOS) completed Phase I and II Small Business Innovation Research (SBIR) contracts with NASA's Langley Research Center to develop moisture- and pH-sensitive sensors to detect corrosion or pre-corrosive conditions, warning of potentially dangerous conditions before significant structural damage occurs. This new type of sensor uses a specially manufactured optical fiber whose entire length is chemically sensitive, changing color in response to contact with its target, and demonstrated to detect potentially corrosive moisture incursions to within 2 cm. After completing the work with NASA, the company received a Defense Advanced Research Projects Agency (DARPA) Phase III SBIR to develop the sensors further for detecting chemical warfare agents, for which they proved just as successful. The company then worked with the U.S. Department of Defense (DoD) to fine tune the sensors for detecting potential threats, such as toxic industrial compounds and nerve agents. In addition to the work with government agencies, Intelligent Optical Systems has sold the chemically sensitive fiber optic cables to major automotive and aerospace companies, who are finding a variety of uses for the devices. Marketed under the brand name Distributed Intrinsic Chemical Agent Sensing and Transmission (DICAST), these unique continuous-cable fiber optic chemical sensors can serve in a variety of applications: Corrosive-condition monitoring, aiding experimentation with nontraditional power sources, as an economical means of detecting chemical release in large facilities, as an inexpensive "alarm" systems to alert the user to a change in the chemical environment anywhere along the cable, or in distance-resolved optical time domain reflectometry systems to provide detailed profiles of chemical concentration versus length.

Source record↗

Corrosion of Containment Alloys in Molten Salt Reactors and the Prospect of Online Monitoring

The aim of this review is to communicate some essential knowledge of the underlying mechanism of the corrosion of structural containment alloys during molten salt reactor operation in the context of prospective online monitoring in future MSR installations. The formation of metal halide species and the progression of their concentration in the molten salt do reflect containment corrosion, tracing the depletion of alloying metals at the alloy salt interface will assure safe conditions during reactor operation. Even though the progress of alloying metal halides concentrations in the molten salt do strongly understate actual corrosion rates, their prospective 1 st order kinetics followed by near-linearly increase is attributed to homogeneous matrix corrosion. The service life of the structural containment alloy is derived from homogeneous matrix corrosion and near-surface void formation but less so from intergranular cracking (IGC) and pitting corrosion. Online monitoring of corrosion species is of particular interest for molten chloride systems since besides the expected formation of chromium chloride species CrCl 2 and CrCl 3 , other metal chloride species such as FeCl 2 , FeCl 3 , MoCl 2 , MnCl 2 and NiCl 2 will form, depending on the selected structural alloy. The metal chloride concentrations should follow, after an incubation period of about 10,000 hours, a linear projection with a positive slope and a steady increase of <1 ppm per day. During the incubation period metal concentration show 1 st order kinetics and increasing linearly with time. Ideally, a linear increase reflects homogeneous matrix corrosion, while a sharp increase in the metal chloride concentration could set a warning flag for potential material failure within the projected service life, e.g. as result of intergranular cracking or pitting corrosion. Continuous monitoring of metal chloride concentrations can therefore provide direct information about the mechanism of the ongoing corrosion scenario and offer valuable information for a timely warning of prospective material failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Near-field passive sensor for the monitoring of high-temperature oxidative corrosion of metals

This study reports on the development and testing of a passive wireless device designed to track temperature and corrosion behavior in SS304H stainless steel under elevated temperatures. The ANSYS HFSS software was utilized to model and optimize the design of an inductor-capacitor (LC) resonator passive wireless sensors fabricated using platinum designs printed onto an aluminum oxide support operating at frequencies between (50–190 MHz). The optimal LC wireless sensor designs were then fabricated using screen-printing and sintering methods. Here, the sensors were tested by placing the sensor onto polished SS304H flat substrates and heated to 900–1050 °C in air. Wireless acquisition of sensor data during heating, cooling, and isothermal stages was achieved through a Pt loop antenna connected to an RF signal generator and a network analyzer.

20 FOSSIL-FUELED POWER PLANTS↗

Oxidation and hot corrosion of hot-pressed Si3N4 at 1000 deg C

The oxidation and hot corrosion of a commercial, hot-pressed Si3N4 were investigated at 1000 C under an atmosphere of flowing O2. For the hot corrosion studies, thin films of Na2SO4 were airbrushed on the Si3N4 surface. The hot corrosion attack was monitored by the following techniques: continuous weight measurements, SO2 evolution, film morphology, and chemical analyses. Even though the hot corrosion weight changes after 25 hr were relatively small, the formation of SiO2 from oxidation of Si3N4 was an order of magnitude greater in the presence of molten Na2SO4. The formation of a protective SiO2 phase at the Si3N4 surface is minimized by the fluxing action of the molten Na2SO4 thereby allowing the oxidation of the Si3N4 to proceed more rapidly. A simple process is proposed to account for the hot corrosion process.

Fielder, W. L.↗

In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N 2 , O 2 , or H 2 O

Here, in situ transmission electron microscopy (TEM) diffraction and imaging techniques are used to monitor and quantify corrosion of Inconel-625 by pure molten chloride salts (MgCl 2 – NaCl – KCl) at 500 °C–800 °C in 1.0 atm inert N 2 or pure O2, or by salts which are controllably hydrated in a high vacuum chamber. The isothermal corrosion rate R in inert N 2 increases from 203 ± 30 μ m year –1 at 700 °C to 463 ± 30 μ m year –1 at 800 °C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μ m year –1 at 700 °C. Salt hydration dramatically accelerates corrosion to R > 3 × 10 5 μ m year –1 at 700 °C while it leads to a more moderate R = 95 ± 20 and 486 ± 30 μ m year –1 at 500 °C and 600 °C, respectively. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600 °C, where corrosion is aggravated by increased generation and solubility of corrosive HCl gases. Hence, to reduce rate of corrosion it is important to both avoid incorporation of H 2 O into the system at each stage and ensure proper flushing of the system before increasing the temperature beyond 600 °C. Compositional analysis of the corroded cells indicate that corrosion in O 2 ambient is dominated by oxidation of metals by O 2 gas dissolved in the chloride melt, but corrosion in H 2 O ambients is caused by chlorination of metals by dissolved HCl gas and MgOH + ions. So, to reduce rate of corrosion, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O 2 . All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds of Ni, Mo and Cr involving NiCl 2 , (Na,K) 2 MoO 4 and CrO 2 (OH) 2 are detected in N 2 , H 2 O, and O 2 ambients, respectively. We believe that corrosion acceleration can be minimized by minimizing formation of volatile by-products or promoting reactions that could convert these volatile compounds to solid phases, as these volatile compounds led to destruction of protective oxide layers.

14 SOLAR ENERGY↗

Real-time Canister Welding Health Monitoring and Prediction System for Spent Fuel Dry Storage

In this report, the salt mist corrosion testing at controlled temperature was carried out successfully on 304L SS submerged arc welded coupons by Unifog Dispersion Tower at ORNL. Corrosion in-situ monitoring system from Intelligent Automation, Inc. (IAI) was setup in the corrosion test and running smoothly to record signals during the corrosion test. Parts and device selection, sensors attachment, and experimental procedures are discussed. There wasn’t any visible corrosion or crack propagation on the weld coupon after about a month of corrosion testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrosion rates measured under potentiostatic conditions to represent performance of a cermet nuclear waste form

Electrochemical tests were conducted to assess the corrosion performance of a developmental multiphase cermet nuclear waste form in different conditions. Corrosion currents were monitored as the surface equilibrated in an acidic brine solution during potentiostatic tests at different imposed potentials. Electrochemical impedance spectroscopy was used to quantify differences in the electrical properties of surfaces stabilised at different potentials. The passivating oxides that will stabilise the surface under disposal conditions are formed and maintained during testing. The measured corrosion currents were two orders of magnitude lower for passivated surfaces than for polished surfaces over a wide range of redox conditions. The electrochemical results were correlated with microscopic analyses of the corroded surfaces and physical models of the surface passivation and degradation processes are proposed. The measured corrosion rates are suitable for the long-term performance modeling of cermet nuclear waste forms.

Gattu, V. K.↗

Optical Structural Health Monitoring Device

This non-destructive, optical fatigue detection and monitoring system relies on a small and unobtrusive light-scattering sensor that is installed on a component at the beginning of its life in order to periodically scan the component in situ. The method involves using a laser beam to scan the surface of the monitored component. The device scans a laser spot over a metal surface to which it is attached. As the laser beam scans the surface, disruptions in the surface cause increases in scattered light intensity. As the disruptions in the surface grow, they will cause the light to scatter more. Over time, the scattering intensities over the scanned line can be compared to detect changes in the metal surface to find cracks, crack precursors, or corrosion. This periodic monitoring of the surface can be used to indicate the degree of fatigue damage on a component and allow one to predict the remaining life and/or incipient mechanical failure of the monitored component. This wireless, compact device can operate for long periods under its own battery power and could one day use harvested power. The prototype device uses the popular open-source TinyOS operating system on an off-the-shelf Mica2 sensor mote, which allows wireless command and control through dynamically reconfigurable multi-node sensor networks. The small size and long life of this device could make it possible for the nodes to be installed and left in place over the course of years, and with wireless communication, data can be extracted from the nodes by operators without physical access to the devices. While a prototype has been demonstrated at the time of this reporting, further work is required in the system s development to take this technology into the field, especially to improve its power management and ruggedness. It should be possible to reduce the size and sensitivity as well. Establishment of better prognostic methods based on these data is also needed. The increase of surface roughness with fatigue is closely connected to the microstructure of the metal, and ongoing research is seeking to connect this observed evidence of the fatigue state with microstructural theories of fatigue evolution to allow more accurate prognosis of remaining component life. Plans are also being discussed for flight testing, perhaps on NASA s SOFIA platform.

Buckner, Benjamin D.↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In Situ Transmission Electron Microscopy of High-Temperature Inconel-625 Corrosion by Molten Chloride Salts

This paper describes an approach to monitor high temperature molten chloride (MgCl 2 -NaCl-KCl) salt corrosion of Inconel-625 alloy in real time at high spatial resolution. The approach is based on a micro-environmental-cell assembly integrated into a transmission-electron-microscope goniometer to examine in situ the salt-alloy interface during corrosion, employing real time electron diffraction and imaging. It establishes procedures to minimize incorporation of H 2 O or O 2 from atmosphere in the chloride salts during sample fabrication and corrosion, which is critical to understanding the fundamental corrosion mechanisms. A clustering algorithm and a 2D Gaussian fit function are used to determine diffraction spot intensities in in situ diffraction patterns, to quantify alloy corrosion. This facilitates quantitative observation of the evolution of individual grains, in contrast to conventional macroscopic corrosion rate quantification. The isothermal corrosion rate of Inconel-625 in an anhydrous, unoxidized salt-stack is 220 ± 30 μm year -1 at 700 °C and 350 ± 20 μm year -1 at 800 °C. However, the corrosion rate at 700 °C increases five-fold to 1000 ± 170 μm year -1 when the salt stack is air-exposed, indicating the dominant effects of hydrated or oxidized impurities on corrosion acceleration. Furthermore, real time imaging of the microstructure evolution suggests that corrosion is initiated at grain boundaries.

14 SOLAR ENERGY↗

Determine Oxidation State of Transition Metals in Molten Salt Corrosion using Electron Energy Loss Spectroscopy

This work utilizes electron energy loss spectroscopy (EELS) to identify oxidation state of alloying elements in Ni-based alloys after exposure to molten chloride salt systems. Pure Ni and Ni 20Cr model alloy were corroded in molten ZnCl2 and KCl-MgCl2 under argon atmosphere at various temperatures. Oxidation states of Cr (Cr3+) and Ni (Ni2+) in the molten salt after corrosion were determined by monitoring changes in the L2,3 edges of corresponding EELS spectra. Oxidation state mapping technique using principal component analysis and multiple linear least squares fitting in HyperSpy Python package was developed.

36 MATERIALS SCIENCE↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simultaneous real-time measurement of composition, flow, attenuation, density, and pipe-wallthickness in multiphase fluids

Apparatus (10) and methods for making simultaneous measurements of composition (water-cut), fluid flow, and sound attenuation in a multiphase fluid flowing (15) through a pipe (12) in real-time, using the same apparatus (10) are described. Additionally, the apparatus (10) provides real-time pipe wall thickness monitoring for observing pipe corrosion or internal deposition. Knowledge of wall thickness is necessary to correct for water-cut (oil-water composition) automatically by adjusting the liquid path length internal to the pipe (spool). The use of short duration frequency chirp excitation signals (24) enables the apparatus to provide information that can be used to extract multiple levels of information from the same measurement in multiphase fluids including the presence of a significant quantity of gas (˜60% gas volume fraction) in different flow regimes. Besides measuring steady flow, this device is useful for measurements during fast changing flows, such as for a rod-pumped well. Measurements up to about 1000 times a second can reliably be made.

Sinha, Dipen N.↗

Hawai‘i National Marine Renewable Energy Center (HINMREC)

The Hawaii National Marine Renewable Energy Center (HINMREC) was established to facilitate the commercialization of wave energy converter (WEC) devices, and to accelerate development and testing of Ocean Thermal Energy Conversion (OTEC) technologies. Housed at the Hawaii Natural Energy Institute (HNEI) of the University of Hawaii (UH), this program started with execution of the contract between the US Department of Energy (DOE) and UH in March 2009, and activities ran through the end of the project in September 2019. The DOE tasked HINMREC with facilitating and accelerating the build-out of the Navy’s Wave Energy Test Site (WETS), the nation’s first grid-connected open water wave energy conversion test facility, located off Marine Corps Base Hawaii (MCBH) in Kaneohe, on the island of Oahu. WETS was expanded from an existing test berth at 30m water depth to include test berths at 60m and 80m water depths. In recognition of the high costs associated with at-sea testing and evaluation of WEC devices, it was deemed imperative that HINMREC seek ways to reduce costs to developers by providing key research support to these early-stage technologies. WETS and HINMREC’s support allowed development of wave energy technology by providing a testing infrastructure that allows technology developers to test, demonstrate and evaluate their WEC devices, and generate data in order to advance WEC designs toward commercial readiness. HINMREC’s roles have included support in the establishment of the full site, including of wave resource characterization and site survey, followed by the essential roles of independent WEC device power performance assessment and environmental monitoring in support of deployed pre-commercial WECs. This DOE-funded work transitioned effectively to continue Navy-funded tasks for OTEC development, and activities at WETS, now under Naval Facilities Engineering Command (NAVFAC) funding. A secondary objective in the establishment of HINMREC was to assist the private sector in moving OTEC systems beyond proof-of-concept to pre-commercialization, primarily focused on system and component engineering, and local and global investigations into the potential environmental impacts of OTEC systems. HINMREC was tasked with maintaining high-resolution models of ocean thermal resources and the potential sustainable power output of OTEC systems. Ongoing tests begun previously under Navy funding at the OTEC Heat Exchangers (HXs) Test Facility at the Natural Energy Laboratory of Hawaii Authority (NELHA), in Kona on Hawaii Island, have been continued to identify cost-effective aluminum alloys for use in OTEC systems operating in the corrosive marine environment.

16 TIDAL AND WAVE POWER↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗