Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contractors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SPC-2772 Rev 2 General Build to Print Fabrication Specification for Nuclear Use Items

This specification is for use with Safety Significant structures, systems, and components. The scope is for build to print fabrication including, but not limited to, machining, forming, welding, cutting, assembling, etc. Specific scope and associated requirements will be identified in drawings and/or additional procurement documents. ASME B31 fabrication is not included in the scope of this specification. Any conflict between this specification and referenced Codes and Standards, or any supplementary specifications in the procurement documents requires written clarification from the Contractor prior to proceeding with any work. Any deviation from the procurement documents requires approval by the Contractor with the change request process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SPC-70486 Rev 0 Stirling Engine Prototype Performance Specification

Idaho National Laboratory (INL) is developing a small microreactor to produce electrical power utilizing a small nuclear core and Stirling engines under the Microreactor Application Research Validation and Evaluation (MARVEL) program. The purpose of this performance specification is to define requirements to build and test the Stirling Engine prototype, including interfacing with Kinnetech in the development/test of the engines. This specification includes prototyping components only and are not for use in the reactor. Prototype testing is a preliminary test to be conducted with conceptual equipment from which a final design will be developed. The results of the testing defined herein will not be used as a qualification test. The Stirling Engines have an engine controller module (QEC). Currently, the QEC doesn’t have a means to stop the engine. An analog controlled engine braking system must be developed and tested with the engine prototype. Any conflict between this specification and any supplementary specifications in the procurement documents requires written clarification from the Contractor prior to proceeding with any work. Any deviation from the procurement documents requires approval by the Contractor with the change request process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SPC-70525 Rev 2 Beryllium Metal Procurement Specification

Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core under the Microreactor Application Research Validation and Evaluation (MARVEL) program. Key to this design are neutron reflector components constructed of Beryllium Metal (S-65) which is a structural grade of hot-pressed beryllium block. MARVEL will be located at the Transient Reactor Test (TREAT) facility. Any conflict between this specification and referenced Codes and Standards, or any supplementary specifications in the procurement documents requires written clarification from the Contractor prior to proceeding with any work. Any deviation from the procurement documents requires approval by the Contractor with the change request process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SPC-70804 Rev 1 Zircar ZAL-45 Alumina Standoff Plates for Use in MARVEL

Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core and Stirling engines under the Microreactor Application Research Validation and Evaluation (MARVEL) program. This procurement specification defines the requirements for fabrication of the MARVEL ZAL-45 standoff plates manufactured by Zircar. The design requires eight (8) ceramic standoff plates; however, the requested quantity shall be twelve to account for required testing after receipt of materials. Any conflict between this specification and referenced Codes and Standards, or any supplementary specifications in the procurement documents requires written clarification from the Contractor prior to proceeding with any work. Any deviation from the procurement documents requires approval by the Contractor with the change request process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SPC-70843 Rev 0 MARVEL Control Drum Actuator Fabrication Specification

Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core and Stirling engines under the Microreactor Application Research Validation and Evaluation (MARVEL) program. This procurement specification defines the requirements for fabrication of components that make up the control drum (CD) actuators. This specification outlines the requirements for fabrication, acknowledging that specific elements will integrate into final assemblies, while others will be delivered as standalone components. The Subcontractor is not responsible for the CD actuator’s final assembly. Any conflict between this specification and referenced Codes and Standards, or any supplementary specifications in the procurement documents requires written clarification from the Contractor prior to proceeding with any work. Any deviation from the procurement documents requires approval by the Contractor with the change request process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

PV System Owner's Guide to Identifying, Assessing, and Addressing Weather Vulnerabilities, Risks, and Impacts

The report is designed to help federal facility managers, engineers, contractors, and consultants identify the most common PV system vulnerabilities that could lead from mild to catastrophic loss of PV systems during severe weather events. The guide helps users understand the type and severity of severe weather that can occur at any given location, and provides pre- and post-storm operations and maintenance (O&M) measures that can reduce the potential for damage to a PV system during a severe weather event and help speed the recovery of a PV system damaged during a storm. The guide emphasizes safety in responding to damage from severe weather events.

14 SOLAR ENERGY↗

Safely Exploring Solar: A Guide for Austin Energy Customers

It's easy to get overwhelmed as you start to explore your solar options. There is a wealth of information available out there, particularly online, and it can be hard to know who to trust. This informational guide has been adapted from Austin Energy's Solar Education Course and other national best practice resources, as of May 1, 2023. It will help you understand some of the key concepts and resources available to help you on your solar journey if you have a home in Austin Energy's service territory and are considering installing solar. This document includes: (1) Austin Energy Programs and Services Related to Solar; (2) Tips for Spotting a Solar Scam; (3) Things to Know When Designing Your System; (4) Key Considerations When Shopping for a Solar Contractor; and (5) Final Takeaways.

14 SOLAR ENERGY↗

Austin Solar Guide (Flyer)

This flyer was developed to guide homeowners on their solar journey and expand the benefits of solar to local residents. The guide is an overview of various energy and solar programs and services through the Austin Energy utility with tips for spotting scams, a summary of common terms when designing a solar system, and considerations when searching for a solar contractor.

14 SOLAR ENERGY↗

Behavioral Approaches to Improve Consumer Uptake of Inflation Reduction Act Incentives

During this workshop, attendees will suggest how local home improvement contractors can be encouraged to support the roll out of Inflation Reduction Act (IRA) provisions with behavioral insights. Workshop sponsor, NREL, and workshop moderator, Dr. Sussman, will compile audience suggestions for states, local governments, and the US Department of Energy to inform their rollout of the IRA.

behavior↗

Accelerating Discovery to Deployment: Argonne's Materials Engineering Research Facility (MERF) and Its Role in Scaling Materials Technologies for Water and Resource Solutions

The U.S. Department of Energy (DOE) national laboratories represent a unique class of government‐owned, contractor‐operated research institutions dedicated to conducting research and development (R&D) related activities that address national priorities, supporting and advancing the DOE mission. They play a vital role in sustaining U.S. innovation capacity, stewarding the nation's technical base, and nurturing science and technologies. In this perspective, we highlight the processing science and scaleup capabilities of the Materials Engineering Research Facility (MERF) at DOE's Argonne National Laboratory to demonstrate how DOE National Laboratories bridge fundamental science and applied technology development to accelerate deployment. Case studies are presented on selective membranes for critical mineral recovery, sensors for per‐ and polyfluoroalkyl substances (PFAS) detection, surface functionalization via atomic layer deposition (ALD) and sequential infiltration synthesis (SIS), and lithium recovery from battery recycling waste streams using a novel electrodialysis process. These examples underscore MERF's role in translating innovative technologies into practical solutions for renewable water and critical resource recovery, which also leverage Argonne's analytical and computational capabilities. This perspective also outlines mechanisms for collaborating with the DOE national laboratories to strengthen partnerships across government, the national laboratories, academia, and industry.

36 MATERIALS SCIENCE↗

Whole-building life-cycle analysis with a new GREET® tool: Embodied greenhouse gas emissions and payback period of a LEED-Certified library

Embodied greenhouse gas (GHG) emissions of building components and buildings operations need to be quantified to holistically address building sustainability. To evaluate embodied GHG emissions of buildings and to provide insights on building materials and building design decisions toward decarbonization, we have recently created a building life-cycle assessment (LCA) module in the widely used Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET (R)) LCA model. We applied the GREET building LCA module to examine embodied GHG impacts and the payback period of a LEED (Leadership in Energy and Environmental Design) certified public library in Chicago, USA. We developed localized, detailed life-cycle inventories to address individual building materials used in the library. We expanded the LCA system boundary to include the mechanical, electrical, and plumbing system, as well as refrigerant impacts, which are often ignored in previous studies. Results show that the total embodied GHG emissions are approximately 817 metric tons, or approximately 538 kg/m 2 . Sensitivity analysis highlights the positive role of increasing the use of recycled materials for reducing embodied GHG emissions. Sensitivity analysis on embodied GHG emissions payback periods shows the need to benchmark the embodied and operational carbon performance of buildings for comparison to alternative building designs and sustainability practices. Furthermore, this analysis demonstrates that building LCA models, such as the GREET building LCA module, which addresses embodied and operational GHG emission impacts of whole buildings holistically, could empower building architects, technology developers, manufacturers, and general contractors to address embodied and operational impacts holistically for building sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost details from front-end engineering design of piperazine with the advanced stripper

This Front-End Engineering Design (FEED) was funded by the U.S. Department of Energy (DOE) to estimate the cost to capture and compress 90% of the CO 2 from an existing natural gas combined cycle (NGCC) in Denver City, Texas, USA. The FEED used the PZAS (Piperazine with the Advanced Stripper) 2G amine scrubbing technology developed and modeled by The University of Texas at Austin. This FEED is unique in providing more public cost details than other FEEDs funded by DOE. The primary objective of the FEED was to provide a comprehensive estimate for the total installed cost of the capture plant. The estimated capital cost of NGCC at the Mustang Station is $\$727$ million for a capacity of 460 MW and 1.6 million tonnes CO 2 /yr. This includes a contingency of $\$104.6$ million and a contractor’s profit of $\$60.1$ million. The total direct field cost is $\$384.1$ million. With an optimistic fuel value of $\$3$/MMBtu, the estimated cost of capture varies from $\$85$/t at 4% IRR/85% load to $\$170$/t at 10% IRR/52% load. Air cooling is technically feasible but expensive. The air cooling systems for the water wash and pump-around intercooling account for 23.4% of the direct cost. The gas-fired boilers represent only 4% of the direct costs, but steam extraction would reduce energy cost, free up cooling water, and reduce the direct costs of processing additional flue gas and CO 2 from the boilers. The absorbers represent 9.6% of the direct cost in this FEED with no direct contact cooler and only 7.6 m of packing. Furthermore, the solvent cross exchangers are less expensive than expected (2.5% of direct costs). Doubling the number of these exchangers could reduce the heat duty from 3.0 to 2.5 GJ/t CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing the cost of home energy upgrades in the US: An industry survey

Decarbonizing the US residential building stock requires a substantial acceleration in home energy upgrades. Numerous barriers exist to accelerating adoption of efficient and electric building technologies, but foremost among these is high upfront costs. This study uses an industry survey delivered to a sample of home energy professionals to examine promising cost reduction strategies across a range of project types, including HVAC, water heating, and envelope/insulation projects. The survey included quantitative and qualitative questions to collect evidence on the estimated cost reduction potential of these strategies and their likelihood of use in the construction industry. The 167 survey respondents included contractors, energy consultants, architects, manufacturers, and others with experience in delivering energy upgrades in single-family and multifamily buildings in the US. Results show that significant cost reductions are achievable by minimizing additional infrastructure costs (such as replacing electric panels), streamlining project planning/management, and deploying innovations that simplify installation. We find that for a typical deep retrofit project, including heat pumps for space and water heating in addition to envelope upgrades, the strategies could result in a total installed cost reduction of nearly 50%, dramatically improving the customer economics of such a project. This research makes a novel contribution to the literature on strategies to reduce the costs of residential retrofits. We discuss how our study's insights on the highest-value cost reduction strategies for home energy upgrades can further accelerate their uptake in the US housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Iraq/Afghanistan war lung injury reflects burn pits exposure

This descriptive case series retrospectively reviewed medical records from thirty-one previously healthy, war-fighting veterans who self-reported exposure to airborne hazards while serving in Iraq and Afghanistan between 2003 and the present. They all noted new-onset dyspnea, which began during deployment or as a military contractor. Twenty-one subjects underwent non-invasive pulmonary diagnostic testing, including maximum expiratory pressure (MEP) and impulse oscillometry (IOS). In addition, five soldiers received a lung biopsy; tissue results were compared to a previously published sample from a soldier in our Iraq Afghanistan War Lung Injury database and others in our database with similar exposures, including burn pits. We also reviewed civilian control samples (5) from the Stony Brook University database. Military personnel were referred to our International Center of Excellence in Deployment Health and Medical Geosciences, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell under the auspices of Northwell IRB: 17-0140-FIMR Feinstein Institution for Medical Research “Clinicopathologic characteristics of Iraq Afghanistan War Lung Injury.” We retrospectively examined medical records, including exposure data, radiologic imaging, and non-invasive pulmonary function testing (MGC Diagnostic Platinum Elite Plethysmograph) using the American Thoracic Society (ATS) standard interpretation based on Morgan et al., and for a limited cohort, biopsy data. Lung tissue, when available, was examined for carbonaceous particles, polycyclic aromatic hydrocarbons (Raman spectroscopy), metals, titanium connected to iron (Brookhaven National Laboratory, National Synchrotron Light Source II, Beamline 5-ID), oxidized metals, combustion temperature, inflammatory cell accumulation and fibrosis, neutrophil extracellular traps, Sirius red, Prussian Blue, as well as polarizable crystals/particulate matter/dust. Among twenty-one previously healthy, deployable soldiers with non-invasive pulmonary diagnostic tests, post-deployment, all had severely decreased MEP values, averaging 42% predicted. These same patients concurrently demonstrated abnormal airways reactance (X5Hz) and peripheral/distal airways resistance (D5–D20%) via IOS, averaging – 1369% and 23% predicted, respectively. These tests support the concept of airways hyperresponsiveness and distal airways narrowing, respectively. Among the five soldiers biopsied, all had constrictive bronchiolitis. We detected the presence of polycyclic aromatic hydrocarbons (PAH)—which are products of incomplete combustion—in the lung tissue of all five warfighters. All also had detectable titanium and iron in the lungs. Metals were all oxidized, supporting the concept of inhaling burned metals. Combustion temperature was consistent with that of burned petrol rather than higher temperatures noted with cigarettes. All were nonsmokers. Neutrophil extracellular traps were reported in two biopsies. Compared to our prior biopsies in our Middle East deployment database, these histopathologic results are similar, since all database biopsies have constrictive bronchiolitis, one has lung fibrosis with titanium bound to iron in fixed mathematical ratios of 1:7 and demonstrated polarizable crystals. These results, particularly constrictive bronchiolitis and polarizable crystals, support the prior data of King et al. (N. Engl. J. Med. 365:222–230, 2011) Soldiers in this cohort deployed to Iraq and Afghanistan since 2003, with exposure to airborne hazards, including sandstorms, burn pits, and improvised explosive devices, are at high risk for developing chronic clinical respiratory problems, including: (1) reduction in respiratory muscle strength; (2) airways hyperresponsiveness; and (3) distal airway narrowing, which may be associated with histopathologic evidence of lung damage, reflecting inhalation of burned particles from burn pits along with particulate matter/dust. Non-invasive pulmonary diagnostic tests are a predictor of burn pit-induced lung injury

36 MATERIALS SCIENCE↗

Productivity and cost of energy chipping with non-integrated harvesting systems in the Coastal Plain of the US south

Research from the 1980s–2010s suggested that integrated harvesting systems that harvest conventional products (e.g., sawtimber, pulpwood) and energy chips simultaneously were the most effective solution to produce energy chips in the US South. Alternatives, such as biomass-only systems, have important advantages in forest stands with low volumes of merchantable timber. The goal of this study was to estimate the productivity and cost of producing energy chips using non-integrated systems. Innovative chipping contractors using non-integrated systems were identified through contacts with procurement foresters responsible for purchasing energy chips. Elemental time-and-motion studies were conducted to estimate harvesting productivity on five operations, including one clearcut harvest and four first thinnings in overstocked stands. The hourly cost of equipment was estimated using the machine rate method. Cost per tonne was estimated by combining hourly productivity and hourly costs in a modified version of the Auburn Harvesting Analyzer. System productivity averaged 37 tonnes per scheduled machine hour (smh) and cut-and-haul costs averaged $33.86 t −1 (USD), which was comparable to previous estimates from integrated systems. In conclusion, this study suggests there are viable alternatives to integrated harvesting systems to produce energy chips, especially in stands with low volumes of merchantable timber.

09 BIOMASS FUELS↗

Role of uncertainties in protecting ecological resources during remediation and restoration

Cleanup of contaminated waste sites is a National priority to protect human health and the environment, while restoring land to productive uses. While there are uncertainties with under standing risk to individuals from exposure, the aim of this study was to focus on uncertainties and complexities for ecological systems, complicated by hundreds of species occupying any remediation site which participate in multiple-interacting food webs. The ability to better predict the effectiveness of remediation in fostering future ecosystems might facilitate remedy selection and improve strategic environmental management. This investigation examined (1) uncertainties in ecosystem processes, (2) uncertainties in exposure from contamination before remediation, and (3) uncertainties during remediation. Two Department of Energy sites Hanford Site and Savannah River Site were used as case studies to illustrate how the uncertainties affect eco-receptors. Several types of ecological, physical, and human dimension uncertainties are defined. Ecological uncertainties include temporal, spatial, individual, developmental, and exogenous types. Physical uncertainties are weather-related, watershed variations, slope/aspect, soil/sediment structure and form, unforeseen events, and temporal patterns. Human dimension uncertainties include current land use, future land use, extractive and non-extractive recreation. The effects of remedial strategies varied between the two sites because Hanford is a primarily arid shrub-steppe ecotype, while Savannah River is a wet forest ecotype. Defining the associated ecological sensitivities and uncertainties and providing examples might help policy-makers, managers, planners, and contractors to be aware of issues to consider throughout planning, remediation, and restoration. Adding ecological uncertainty analysis to risk evaluations and remediation planning is analogous to using safety factors in human health risk assessment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗