Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous air monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

GEMINI Case Study

Sandia's GEMINI-Scout Mine Rescue Robot is an unmanned ground vehicle designed to enter potentially hazardous environments to explore, assess, and evaluate dangerous situations first responders may face when conducting a rescue mission. GEMINI is approximately four feet long and two feet tall, which enables the robot to maneuver through small locations on rough terrains caused by earthquakes, fires, or radiological incidents. GEMINI uses track propulsion to climb stairs, travel through gravel and sand pits, pivot in place, and traverse 45-degree climbs with few problems. Furthermore, the vehicle's dual tracked-chassis design allows it to operate in hostile, dark, muddy, high-temperature, and explosive debris-strewn environments, while maintaining efficient ground mobility. The mobility and modularity of the vehicle allow for easy integration of sensors to conduct gas and temperature sensing and offers pan/tilt, zoom color, and thermal camera video streaming capabilities. The vehicle is also able to carry a payload of about 50 pounds of batteries and can handle an additional 200 pounds of payload, whether for additional diagnostics, supplies, or clothing for those trapped in an effected area. GEMINI is remotely operated through a wireless connection and an onboard computer running a customized embedded control application, which directly communicates to all onboard components except for the audio and video systems. When line of sight is not possible, operators use a shockresistant fiber optic cable to ensure continuous functionality of the vehicle. This allows for direct local control of the vehicle, which streams collected data back to the operator for enhanced situational awareness. In addition, the vehicle incorporates safety features such as explosion proof housing to ensure safe electronic operations in hazardous gas or flooded environments; a four-channel video link and two-way audio to ensure located survivors can communicate with operators; and an MSHA-approved multi-gas sensor to monitor air quality.

42 ENGINEERING↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2021

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2021. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2021 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 VAC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 °C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 °C) and with the oven off (at 22 °C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 °C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.

Sriraman, Aishwarya↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2020

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2020. The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2020. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2020 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

Resource Conservation and Recovery Act↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

RASA Field Performance at US International Monitoring Stations

This report attempts to collate, analyze, and summarize RASA performance over time at each of 11 US operated IMS stations. The performance over time was compared to routine maintenance operations. The data, in general, were summarized into a set analyzed almost exclusively in Excel. The data set allows for further probing into RASA performance over time. The data set would permit data to be routinely added for continued analysis. In general, all RASA systems ran within the CTBTO mandated the MDA requirements over their current lifetime of operations. The largest impacts to performance appeared to arise from variabilities of Germanium gamma detectors as they were replaced. It is noted that the air volumes of samples were not provided and had to be assumed to be constant over the period analyzed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Pest Management (IPM) for Early Detection Algal Crop Protection. Final Report

During large-scale, outdoor algal biomass growth, production strain(s) are subject to attack by pathogens, predators, and non-productive competitors, compromising the biomass yield. The project team at UCSD developed and demonstrated the effectiveness of Volatile Organic Compound, VOC, analysis via mass spectrometry (MS) as an early detection system for the presence of production algal ponds infection. The MS detection can then trigger high-resolution melt analysis (HRMA) and enhanced quantitative PCR (qPCR) to identify predatory or pathogenic species precisely. This study gathered the foundational data informing how wholly automated systems monitor the health of production ponds. By detecting the presence of low molecular weight VOCs in the air space above ponds, the instrument was able to mimic “sniffing” the health of the algae pond. This early warning system will be free growers from time-consuming and costly regular surveillance of ponds with the current techniques, such as qPCR and flow-cam assays, which are slower, less sensitive, and not easily fully automated, resulting in increased production efficiency through the reduction of crop loss. This project demonstrated that Chemical Ionization Mass Spectrometry, CIMS, could serve as a real-time monitor of ponds health tracking up to 100 different VOCs simultaneously for continuous periods up to 60 days without interruption, signaling infection within an algal crop 24 to 36 hours prior to techniques such as qPCR and microscopy. While mass spectrometry is an expensive tool, this simple VOC sampling system proved not only to be sensitive and robust but could to multiplexed to monitor several ponds, lowering the overall cost serially. This technology demonstrated a reduction in biomass production cost by approximately 50% compared to growers not employing any detection methodology.

09 BIOMASS FUELS↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful selection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Increased salinity decreases annual gross primary productivity at a Northern California brackish tidal marsh

Tidal marshes sequester 11.4–87.0 Tg C yr –1 globally, but climate change impacts can threaten the carbon capture potential of these ecosystems. Tidal marshes occur across a wide range of salinity, with brackish marshes (0.5–18 ppt (parts per thousand)) dominating global tidal marsh extents. A diverse mix of freshwater- and saltwater-tolerant plant and microbial communities has led researchers to predict that carbon cycling in brackish wetlands may be less sensitive to changes in salinity than fresh- or saltwater wetlands. Rush Ranch, a well-monitored brackish tidal wetland of the San Francisco Bay National Estuarine Research Reserve, experiences highly variable annual salinity regimes. Within a five-year period (2014–2018), Rush Ranch experienced particularly extreme drought-induced salinization during the 2014 and 2015 growing seasons. During drought years, tidal channel salinity rose from a 15 year baseline of 4.7 ppt to growing season peaks of 10.3 ppt and 12.5 ppt. Continuous eddy covariance data from 2014 to 2018 demonstrate that during drought summers, gross primary productivity (GPP) decreased by 24%, whereas ecosystem respiration remained similar among all five years. Stepwise linear regression revealed that salinity, not air temperature or tidal height, was the dominant driver of annual GPP. A random forest model trained to predict GPP based on environmental data from low salinity years (i.e. naive to salinization) significantly over predicted GPP in drought years. When growing season salinities were doubled, annual estimates of net ecosystem exchange of CO 2 decreased by up to 30%. These results provide ecosystem-scale evidence that increased salinity influences CO 2 fluxes dominantly through reductions in GPP. This relationship provides a starting point for incorporating the effect of changes in salinity in wetland carbon models, which could improve wetland carbon forecasting and management for climate resilience.

54 ENVIRONMENTAL SCIENCES↗

Conservation of Helium while Maintaining High System Purity

Recent helium shortages and helium price increases have lead to an increased emphasis being placed on conserving helium. The need to conserve helium must be balanced with need to maintain the high levels of purity necessary to prevent operational problems caused by contamination. Helium losses and contamination control are especially important for test stands that have cryogenic distribution systems operating continuously with frequent changeover of cryogenic temperature components that are being tested. This paper describes a mathematical model to estimate the quantity of helium lost and the purity of the helium after the pump and backfill procedure is complete. The process to determine the optimal time during pump down to cut off pumping and start backfilling is described. There is a tradeoff between trying to achieve the lowest possible pressure during pumping and the quantity of air leaking into the volume while pumping is occurring. An additional benefit of careful sel ection of pump and backfill parameters in conjunction with real-time pressure monitoring can reduce the labor and time required to complete a successful pump and backfill procedure. This paper is intended to be a tool for engineers to review their pump and backfill procedures and measured data to optimize helium losses, system purity, and labor required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

User Access to Scientific Facilities via 5G: A Cyber Security Thought Experiment

5G is more than an over-the-air radio technology upgrade. It is a strategy to extend Mobile Network Operator service offerings beyond traditional voice, instant messaging and Internet access. 5G Mobile Network Operators will offer new telecommunication services that include enhanced guarantees of confidentiality, integrity and availability. How could such services change the way Science collaborations connect scientists to supercomputers and other scientific facilities? Current scientific collaborations implicitly trust cloud service providers to securely store and process data. The perceived risks of outsourcing Science data security are counterbalanced by assurances that cloud providers operate at a scale that allows them to implement security measures impractical for Science collaborations (e.g. continuous system administrator behavioral monitoring and strict individual separation of duties). If that is true for a cloud service provider like Amazon Web Services (2018 revenue: $25.7 billion), could it also be true for Mobile Network Operators like Verizon Wireless (2018 revenue: $91.7 billion) or AT&T Mobility (2018 revenue: $71.3 billion)? DOE Leadership Class supercomputer facility users currently access them from the public Internet via Secure Shell. The sponsors and operators of the supercomputer facilities have determined that the public Internet path between the Scientist’s Device and the Login Node does not natively provide enough confidentiality or integrity to protect those communications. Therefore, the facilities achieve additional confidentiality and integrity by requiring Secure Shell encryption across those untrusted network paths. Using 5G Network Slice technology, a Mobile Network Operator may offer communication services between supercomputer users and facilities that natively provide confidentiality and integrity guarantees. Sponsors and operators of supercomputer facilities may determine that these guarantees provide enough confidentiality and integrity to protect those communications. If so, a 5G Network Slice could replace an SSH session running over the public Internet. Finally, this use case could be extended to other Office of Science user facility access requirements. Consider microscopy instruments at (e.g.) the Center for Nanoscale Materials or the Environmental Molecular Sciences Laboratory. The embedded systems controlling such instruments may not always support encrypted network access technologies like SSH. 5G Network Slices may offer an alternative to current VPN or SSH tunneling techniques, with additional benefits like guaranteed minimum bandwidth.

5G↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2025

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2025. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of the DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, the evaluation of data collected in 2025 continued to indicate that WVDP activities posed no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summertime Carbonaceous Aerosol in Interior Versus Coastal Northern Alaska

Abstract Rapid warming is likely increasing primary production and wildfire occurrence in the Arctic. Projected changes in carbonaceous aerosols during the summer will impact atmospheric chemistry and climate, but our understanding of these processes is limited by sparse observations. Here, we characterize carbonaceous aerosol in Alaska, USA: Toolik Field Station in the Interior and the Atmospheric Radiation Measurement facility at Utqiaġvik on the Arctic coast, during the summers of 2022 and 2023. We estimated PM 2.5 and PM 10 concentrations using laser light scattering (PurpleAir sensors) and examined total carbon (TC) and its organic carbon (OC) and elemental carbon (EC) fractions in total suspended particles (TSP). We investigated the dominant sources of carbonaceous aerosol using air mass backward‐trajectories from the NOAA HYSPLIT model and radiocarbon source apportionment of TC. TC concentrations were about twice as high in the Interior compared to the coast, with contemporary sources dominating at both Toolik (95%–99%) and Utqiaġvik (86%–89%) over minor contributions from fossil sources. Elevated PM, TC, OC, and EC concentrations coincided with major boreal forest fire activity in North America that brought smoke to the region. The radiocarbon signature of EC measured at Toolik during these wildfire events indicated that over 90% of the EC came from contemporary sources. Our measurements demonstrate the potential for Arctic aerosol concentrations to respond significantly to climate warming‐induced changes to the landscape and emphasize the need for continuous atmospheric monitoring to advance our understanding of this rapidly changing environment.

Welch, Allison M. [Department of Earth System Scie↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2024

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2024. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2024 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

54 ENVIRONMENTAL SCIENCES↗