Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗

Development of a Gibbs Energy Minimiser for the MOOSE-based Corrosion Modelling App Yellowjacket and Validation of MSTDB

Nuclear materials are highly complex multiscale, multiphysics systems,and an effective prediction of nuclear reactor performance and safety requires simulation capabilities that tightly couple different physical phenomena. The Idaho National Laboratory’s Multiphysics Object Oriented Simulation Environment (MOOSE) provides the computational foundation for performing such simulations. With the move towards advanced reactors, such as the Molten Salt Reactor (MSR), that employ high temperature fluids compared to conventional reactors, corrosion has become a problem of great interest. A new application called Yellowjacket is currently under development to directly couple thermodynamic equilibrium and kinetics with phase field models in order to model corrosion in MSRs. As part of Yellowjacket, a Gibbs energy minimiser is being developed to perform thermochemical equilibrium calculations for a range of different materials, which is currently in its infancy. This report describes the further progress towards the development of Yellowjacket Gibbs energy minimiser. Ontario Tech University is developing a new Gibbs energy minimiser for Yellowjacket which is the primary contribution of this work. The aim to develop a thermochemistry solver for the MOOSE framework following the same development philosophy and using the same tools and libraries. A special focus is on performance, documentation and SQA. Furthermore through a scope extension partway through the fiscal year a thorough assessment of the MSTDB-TC v1.3 was performed at Ontario Tech University in the context of continuous improvement and quality assurance. The objective of the work was to have an arm’s length review of the database to give confidence that the database is performing as it was intended while assessing its current state to give recommendations to future developments. This assessment involved two parts: A) a quantitative assessment, and B) a qualitative assessment. Part A involved developing an automated test-suite that would compute values from the database using Thermochimica with comparisons to experimental measurements for validation purposes, which gives confidence to the database’s stakeholders that its functioning properly. Part B involved reviewing all binary systems in the database and making a qualitative assessment with two performance indicators: comprehensiveness and overall confidence. It is important to note that the models in the database are empirical, which is to say that the quality of any model is highly dependent on the experimental data used to inform its development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Baseline Monitoring Data for the Remote-Handled Low-Level Waste Disposal Facility at Idaho National Laboratory

The purpose of this document is to summarize environmental monitoring data collected at the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility during the first four years of facility operations (FY 2019 through FY 2022). This summary provides a “baseline” condition for the facility, which can be used to distinguish contaminant releases from the RHLLW Disposal Facility from pre existing contamination as well as potential future releases from other sources (i.e., upgradient aquifer sources), as specified in the facility monitoring plan. Sufficient data has been collected over the first four years of operation of the RHLLW Disposal Facility to establish baseline conditions for future compliance monitoring of aquifer wells and performance monitoring of vadose zone lysimeters. Except for seven elevated tritium measurements from lysimeter HFEF-South believed to have been impacted by waste disposals, all data was deemed appropriate for establishing baseline concentrations. Monitoring of the aquifer detected indicator analytes gross alpha and gross beta and target analytes tritium and C-14. There were a few C-14 detections prior to an increase in the required detection level (RDL) after the first round of sampling. I-129 and Tc-99 were not detected above RDLs in aquifer samples. Lysimeter samples detected indicator analytes gross alpha and gross beta and target analyte tritium. Target analytes C-14, I-129, and Tc-99 were not detected above RDLs in lysimeter samples. Except for tritium, baseline concentrations of indicator and target analytes measured during the first four years of RHLLW facility operations are expected to represent conditions through the expected 20 year operating period of the facility. Elevated tritium in the aquifer, a result of past discharges of tritium at upgradient facilities, showed a decline over the first four years of operations, and levels are expected to continue to decline with time as a result of dilution and decay. Current tritium levels in lysimeter samples may be elevated due to tritium in the water applied during construction and infiltration testing of the facility. As a result, tritium concentrations in lysimeters may decline with time as a result of dilution and decay. Statistical measures (i.e., mean, standard deviation, and 99% upper confidence level [UCL]) were calculated for all detected analytes using the four years of concentration data. These measures will be used to evaluate future monitoring results and to demonstrate the facility is performing, or not performing, as established in the facility performance assessment (PA). Future monitoring results will also be combined with the baseline data in this report to further establish temporal trends and natural variability in the measurements. Based on the data collected during the baseline period, it is recommended the gross alpha action level for performance monitoring increase from 10 to 20 pCi/L due to several baseline measurements exceeding the preliminary action level of 10. An action level of 20 pCi/L is slightly greater than the 99% UCL, is protective of the aquifer, and would reduce unnecessary sampling. It is also recommended that tritium be added to the lysimeter analyte list for post-baseline period monitoring. Tritium, while not a dose concern, is a good tracer that can provide valuable information on water flow in and around the RHLLW Disposal Facility. Recommendations for a tritium action level are provided if considered necessary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D optical diagnostics for explosively driven deformation and fragmentation

High-speed, optical imaging diagnostics are presented for three-dimensional (3D) quantification of explosively driven metal fragmentation. At early times after detonation, Digital Image Correlation (DIC) provides non-contact measures of 3D case velocities, strains, and strain rates, while a proposed stereo imaging configuration quantifies in-flight fragment masses and velocities at later times. Experiments are performed using commercially obtained RP-80 detonators from Teledyne RISI, which are shown to create a reproducible fragment field at the benchtop scale. DIC measurements are compared with 3D simulations, which have been ‘leveled’ to match the spatial resolution of DIC. Overall, results demonstrate improved ability to identify predicted quantities-of-interest that fall outside of measurement uncertainty and shot-to-shot variability. Similarly, video measures of fragment trajectories and masses allow rapid experimental repetition and provide correlated fragment size-velocity measurements. Measured and simulated fragment mass distributions are shown to agree within confidence bounds, while some statistically meaningful differences are observed between the measured and predicted conditionally averaged fragment velocities. Together these techniques demonstrate new opportunities to improve future model validation.

42 ENGINEERING↗

Measurement of C P asymmetries in B 0 → K S 0 K S 0 K S 0 decays at Belle II

We report a measurement of decay-time-dependent charge-parity ( C P ) asymmetries in B 0 → K S 0 K S 0 K S 0 decays. We use 387 × 10 6 B B ¯ pairs collected at the ϒ ( 4 S ) resonance with the Belle II detector at the SuperKEKB asymmetric-energy electron-positron collider. We reconstruct 220 signal events and extract the C P -violating parameters S and C from a fit to the distribution of the decay-time difference between the two B mesons. The resulting confidence region is consistent with previous measurements in B 0 → K S 0 K S 0 K S 0 and B 0 → ( c c ¯ ) K 0 decays and with predictions based on the standard model. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The CosmoVerse White Paper: Addressing observational tensions in cosmology with systematics and fundamental physics.

The standard model of cosmology has provided a good phenomenological description of a wide range of observations both at astrophysical and cosmological scales for several decades. This concordance model is constructed by a universal cosmological constant and supported by a matter sector described by the standard model of particle physics and a cold dark matter contribution, as well as very early-time inflationary physics, and underpinned by gravitation through general relativity. There have always been open questions about the soundness of the foundations of the standard model. However, recent years have shown that there may also be questions from the observational sector with the emergence of differences between certain cosmological probes. In this White Paper, we identify the key objectives that need to be addressed over the coming decade together with the core science projects that aim to meet these challenges. These discordances primarily rest on the divergence in the measurement of core cosmological parameters with varying levels of statistical confidence. These possible statistical tensions may be partially accounted for by systematics in various measurements or cosmological probes but there is also a growing indication of potential new physics beyond the standard model. After reviewing the principal probes used in the measurement of cosmological parameters, as well as potential systematics, we discuss the most promising array of potential new physics that may be observable in upcoming surveys. We also discuss the growing set of novel data analysis approaches that go beyond traditional methods to test physical models. These new methods will become increasingly important in the coming years as the volume of survey data continues to increase, and as the degeneracy between predictions of different physical models grows. There are several perspectives on the divergences between the values of cosmological parameters, such as the model-independent probes in the late Universe and model-dependent measurements in the early Universe, which we cover at length. The White Paper closes with a number of recommendations for the community to focus on for the upcoming decade of observational cosmology, statistical data analysis, and fundamental physics developments.

Dienes, Keith [Univ. of Arizona, Tucson, AZ (Unite↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Monte Carlo method for constructing confidence intervals with unconstrained and constrained nuisance parameters in the NOvA experiment

Measuring observables to constrain models using maximum-likelihood estimation is fundamental to many physics experiments. Wilks' theorem provides a simple way to construct confidence intervals on model parameters, but it only applies under certain conditions. These conditions, such as nested hypotheses and unbounded parameters, are often violated in neutrino oscillation measurements and other experimental scenarios. Monte Carlo methods can address these issues, albeit at increased computational cost. In the presence of nuisance parameters, however, the best way to implement a Monte Carlo method is ambiguous. Furthermore, this paper documents the method selected by the NOvA experiment, the profile construction. It presents the toy studies that informed the choice of method, details of its implementation, and tests performed to validate it. It also includes some practical considerations which may be of use to others choosing to use the profile construction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the impact of high thermal conductivity paper on the performance and life of power transformers

Degradation of insulation paper is a key contributor to the failure of power transformers. Insulation degradation accelerates at elevated temperatures, which highlights the potential for better thermal management to prolong life. While several studies have analyzed the benefits of high thermal conductivity oil for reducing temperatures inside a transformer, this study is an initial assessment of the benefits of high thermal conductivity paper on transformer life. Blending particulates with cellulosic fibers offers a pathway for high thermal conductivity paper (with good dielectric properties), which can reduce internal temperatures. Presently, life extensions that can be achieved by the use of such thermally conducting papers were estimated, with the thermal conductivity of the paper being the key parameter under study. The analytical-numerical thermal model used in this study was validated against experimental measurements in a distribution transformer, adding confidence to the utility of the model. This model was then used to provide estimates of hot-spot temperature reduction resulting from the use of papers with higher thermal conductivity than baseline. Transformer life was predicted conventionally by tracking the degree of polymerization of paper over time, based on an Arrhenius model. Results indicate that increasing the thermal conductivity of paper from 0.2 W/mK (baseline) to 1W/mK reduces the hot spot temperature by 10°C. While degradation significantly depends on the moisture and oxygen content, the model shows that such a temperature reduction can increase life for all conditions, by as much as a factor of three.

42 ENGINEERING↗

A non-fueled nuclear-heated rod for in-pile transient boiling studies

Separate-effects boiling experiments have recently been conducted in the Transient Reactor Test Facility at Idaho National Laboratory to investigate transient heating and irradiation effects on cladding-to-coolant heat transfer. Specifically, transient critical heat flux (CHF) remains an important area of research, and better understanding of this phenomenon has potential for improving predictive models related to operational and safety limits. Consequently, this knowledge is expected to improve efficiency of light-water reactor operations. A novel borated nuclear-heated rodlet (BNHR) was designed to enable observation of transient cladding-to-coolant heat transfer phenomena. The final BNHR design takes a surrogate approach, wherein nuclear heating is induced by 10 B(n, α) reactions rather than derived from fissions in a fueled specimen. The structure of the BNHR consists of a hollowed out borated (B nat ~ 2.05 wt %) stainless steel tube with an hourglass-shaped outer surface, capped at both ends with non-borated stainless steel. This geometry allows for inner-rodlet instrumentation and generation of the highest nuclear heating rates near the center of the rodlet to ensure onset of boiling near instrumentation for real-time observation. A novel approach to measuring the nuclear energy deposition rate in the BNHR separate and apart from the influence of the coolant, termed the n-a thermometer, is also detailed in this paper. This device has demonstrated excellent repeatability, and measurements indicate predictive modeling results for energy deposition in the BNHR rod agree within a 10% margin of the experiment measurements. In conclusion, these results give confidence that the BNHR design has successfully met experiment objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Octopus processor for the CMS L1 muon trigger for High Luminosity LHC

The upgraded L1 muon trigger system of the CMS experiment in the High Luminosity Large Hadron Collider is based on custom processors featuring large Field Programmable Gate Arrays (FPGAs) connected by large numbers of optical links. These provide the I/O bandwidth and power necessary to process the complex algorithms used during the collection of physics data. The design and performance requirements of these processors creates significant challenges in signal integrity, power delivery, and thermal management. In this paper we describe the Octopus processor, featuring a large Xilinx Virtex Ultrascale+ FPGA and up to 128 links interfaced to optics through high quality twin-ax copper cables. Results on signal integrity at 25 Gb/s and the first demonstration of 50+ Gb/s links with pluggable optics in CMS are also shown, demonstrating bit error rates below 10 –15 at a 95% confidence level. The thermal performance is measured inside an Advanced-TCA crate with acceptable thermal margins up to 200 W of chip power. Future improvements are mentioned, potentially allowing operation at up to 300 W.

Instruments & Instrumentation↗

Protorheology

We all instinctively poke, bounce, scoop, and observe materials to understand rheological properties quickly. Yet, these observations are rarely analyzed quantitatively. To address this, here we introduce the paradigm of protorheology: approximate quantitative inference from simple observations. Several case studies demonstrate how protorheology is an inclusive entry to rheology for a broad range of practitioners and strengthens the confidence and interpretation of accurate laboratory measurements. We survey a range of creative tests according to which rheological phenomenon is revealed. Some new working equations are derived, and all working equations are summarized for convenient reference and comparison across different methods. Finally, this establishes a framework to enable increased use of photos, videos, and quantitative inference and to support the increasing interest in digital image analysis, inverse methods, and high-throughput characterization being applied to rheological properties.

42 ENGINEERING↗

Constraining primordial non-Gaussianity with DESI 2024 LRG and QSO samples

We analyse the large-scale clustering of the Luminous Red Galaxy (LRG) and Quasar (QSO) sample from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). In particular, we constrain the primordial non-Gaussianity (PNG) parameter f NL loc via the large-scale scale-dependent bias in the power spectrum using 1,631,716 LRGs (0.6 < z < 1.1) and 1,189,129 QSOs (0.8 < z < 3.1). This new measurement takes advantage of the enormous statistical power at large scales of DESI DR1 data, surpassing the latest data release (DR16) of the extended Baryon Oscillation Spectroscopic Survey (eBOSS). For the first time in this kind of analysis, we use a blinding procedure to mitigate the risk of confirmation bias in our results. We improve the model of the radial integral constraint proposing an innovative technique allowing the correction through the window matrix convolution. We also carefully test the mitigation of the dependence of the target selection on the photometry qualities by incorporating an angular integral constraint contribution to the window function, and validate our methodology with the blinded data. Finally, combining the two samples, we measure f NL loc = -3.6 -9.1 +9.0 at 68% confidence, where we assume the universality relation for the LRG sample and a recent merger model for the QSO sample about the response of bias to primordial non-Gaussianity. Adopting the universality relation for the PNG bias in the QSO analysis leads to f NL loc = 3.5 -7.4 +10.7 at 68% confidence. Due to restricted selection in the LRG sample, the inclusion of the LRGs allows for 10% improvement. This measurement is the most precise determination of primordial non-Gaussianity using large-scale structure to date, surpassing the latest result from eBOSS by a factor of 2.3.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Proton Beam-Driven Fusion Reactions Generated by an Ultra-Short Petawatt-Scale Laser Pulse

We present results from a pitcher-catcher experiment utilizing a proton beam generated with nanostructured targets at a petawatt-class, short-pulse laser facility to induce proton-boron fusion reactions in a secondary target. A 45-fs laser pulse with either 400 nm wavelength and 7 J energy, or 800 nm and 14 J, and an intensity of up to 5 × 10 21 W/cm 2 was used to irradiate either thin foil targets or near-solid density, nanostructured targets made of boron nitride (BN) nanotubes. In particular, for 800 nm wavelength irradiation, a BN nanotube target created a proton beam with about five times higher maximum energy and about ten times more protons than a foil target. This proton beam was used to irradiate a thick plate made of boron nitride placed in close proximity to trigger 11 B (p, α) 2α fusion reactions. A suite of diagnostics consisting of Thomson parabola ion spectrometers, postshot nuclear activation measurements, neutron time-of-flight detectors, and differentially filtered solid-state nuclear track detectors were used to measure both the primary proton spectrum and the fusion products. From the primary proton spectrum, we calculated (p, n) and (α,n) reactions in the catcher and compare with our measurements. The nuclear activation results agree quantitatively and neutron signals agree qualitatively with the calculations, giving confidence that primary particle distributions can be obtained from such measurements. These results provide new insights for measuring the ion distributions inside of proton-boron fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How To Maintain Effective IAEA Safeguards While Reducing Facility Impact

For almost twenty years, inspectors from the International Atomic Energy Agency have been visiting the K-Area Material Storage facility at the Savannah River Site where excess plutonium has been placed under IAEA safeguards as part of the United States Volunatary Offer Agreement. During that time, the mission of K-Area Complex has expanded from storage of nuclear matieral to glovebox operations in support of the National Nuclear Security Administration’s Plutonium Disposition program. With this change in mission, it is becoming increasingly challenging to manage facility staff radiation exposure and operating activities during the IAEA’s annual Physcial Inventory Verifications (PIV). This study has identified both near-term and long-term recommendations for IAEA monitoring protocols that would allow the IAEA to maintain effective safeguards of the material while decreasing the impact to the facility. A statisitical analysis has shown that reducing the number of containers measured during an annual PIV from 12 to 4 still ensures a high level of confidence in the confidence while reducing the inspector time in the facility amd with a corresponding significant reduction in personnel radiation exposure. A modified installation pattern of Remotely Monitored Sealing Arrays (RMSAs) is also proposed utilizing only the outer rows of arrays of stored material containers in the Stack Area (SA). The modified RMSA placement will provide equivalent protection, while significantly reducing personnel radiological exposure, manpower requirements and associated costs. With advances in technology, there are additional potential options in containment/surveillance and continuity of knowledge that would allow the agency to be outside of the facility during PIV measurements and have confidence in the accuracy and authencitity of the results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗