Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condition assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hawai'i Water Resources: Utilizing NASA Earth Observations to Assess Ocean Conditions Leading to the Spread of the Nuisance Red Algae (Chondria tumulosa) in Papahānaumokuākea Marine National Monument, Hawai’i

Chondria tumulosa, a newly discovered red alga, was observed in low abundance in 2016 but has since proliferated and is now smothering and decimating vast expanse of coral reefs in Manawai, located in Papahānaumokuākea Marine National Monument (PMNM). If the spread persists, the outbreak of this cryptogenic species could potentially cause region-wide ecosystem degradation. In coordination with the U.S. Fish and Wildlife Service, Marine National Monuments of the Pacific and the National Oceanographic and Atmospheric Administration (NOAA) Office of National Marine Sanctuaries’ Papahānaumokuākea Marine National Monument, this project created a tool to analyze oceanographic conditions (sea surface temperature (SST), chlorophyll-a, water velocity, salinity, turbidity) across the Monument that could potentially be driving the algal spread. The Google Earth Engine tool enabled the partners to visualize oceanographic conditions and gather time-series graphs utilizing Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), Suomi National Polar-orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS), Sentinel-3 Ocean and Land Colour Instrument (OLCI), Hybrid Coordinate Ocean Model (HYCOM) and NOAA's Climate Data Record in a user-friendly interface. The team used in situ SST data from subsurface temperature recorders provided by the partners to validate the tool's accuracy. Preliminary statistical analysis of MODIS data found warming trends in SST in Manawai as well as increased chlorophyll-a levels during the summer months in contrast to the control (non-infected) Lalo atoll. The tool did not aim to classify algal presence due to limited availability of higher resolution satellite imagery but instead enabled PMNM managers to monitor conditions that may be conducive to algal growth around the monument to make informed decisions and mitigation practices.

DEVELOP Project Summary↗

Controlling and assessing pressure conditions during treatment of tar sands formations

A method for treating a tar sands formation includes providing heat to at least part of a hydrocarbon layer in the tar sands formation from a plurality of heaters located in the formation. Heat is allowed to transfer from the heaters to at least a portion of the formation. A pressure in the portion of the formation is controlled such that the pressure remains below a fracture pressure of the formation overburden while allowing the portion of the formation to heat to a selected average temperature of at least about 280.degree. C. and at most about 300.degree. C. The pressure in the portion of the formation is reduced to a selected pressure after the portion of the formation reaches the selected average temperature.

04 OIL SHALES AND TAR SANDS↗

Experimental Validation of a Resilient Monitoring and Control System

Complex, high performance, engineering systems have to be closely monitored and controlled to ensure safe operation and protect public from potential hazards. One of the main challenges in designing monitoring and control algorithms for these systems is that sensors and actuators may be malfunctioning due to malicious or natural causes. To address this challenge, this paper addresses a resilient monitoring and control (ReMAC) system by expanding previously developed resilient condition assessment monitoring systems and Kalman filter-based diagnostic methods and integrating them with a supervisory controller developed here. While the monitoring and diagnostic algorithms assess plant cyber and physical health conditions, the supervisory controller selects, from a set of candidates, the best controller based on the current plant health assessments. To experimentally demonstrate its enhanced performance, the developed ReMAC system is then used for monitoring and control of a chemical reactor with a water cooling system in a hardware-in-the-loop setting, where the reactor is computer simulated and the water cooling system is implemented by a machine condition monitoring testbed at Idaho National Laboratory. Results show that the ReMAC system is able to make correct plant health assessments despite sensor malfunctioning due to cyber attacks and make decisions that achieve best control actions despite possible actuator malfunctioning. Monitoring challenges caused by mismatches between assumed system component models and actual measurements are also identified for future work.

97 MATHEMATICS AND COMPUTING↗

AVHRR monitoring of U.S. crops during the 1988 drought

Effects of the 1988 drought on crops in the U.S. Corn Belt were assessed and monitored by the Foreign Crop Condition Assessment Division (FCCAD), U.S. Department of Agriculture. The primary data were vegetation index numbers (VINs), each of which was calculated as an average vegetation index of a geographically referenced cell of AVHRR pixels. Using VINs, the FCCAD was able to detect the existence of drought early in the season, monitor changing conditions, and provide objective assessments of the drought's extent and severity. Field observations confirmed the image analyses, and underlined the importance of the timing of extreme weather events with respect to crop stages for interpreting VINs. The analyses were conducted in an operational environment, providing a unique test of the AVHRR data for large area, near real-time crop monitoring. Because large area, operational remote sensing of crops is quite different from traditional, controlled, small plot research studies, more work is needed to link the two; this would improve crop assessment capabilities.

Teng, William L.↗

LWR Sustainability: Assessment of Aging of Nuclear Power Plant Safety Related Concrete Strutures

Current regulatory testing and inspection requirements are reviewed and a summary of degradation experience is presented. Techniques commonly used to inspect NPP concrete structures to assess and quantify age-related degradation are summarized. An approach for conduct of condition assessments of structures in NPPs is presented. Criteria, based primarily on visual indications, are provided for use in classification and assessment of concrete degradation. Materials and techniques for repair of degraded structures are generally discussed.

aging management↗

Improving online risk assessment with equipment prognostics and health monitoring

The current approach to evaluating the risk of nuclear power plant (NPP) operation relies on static probabilities of component failure, which are based on industry experience with the existing fleet of nominally similar light water reactors (LWRs). As the nuclear industry looks to advanced reactor designs that feature non-light water coolants (e.g., liquid metal, high temperature gas, molten salt), this operating history is not available. Many advanced reactor designs use advanced components, such as electromagnetic pumps, that have not been used in the US commercial nuclear fleet. Given the lack of rich operating experience, we cannot accurately estimate the evolving probability of failure for basic components to populate the fault trees and event trees that typically comprise probabilistic risk assessment (PRA) models. Online equipment prognostics and health management (PHM) technologies can bridge this gap to estimate the failure probabilities for components under operation. The enhanced risk monitor (ERM) incorporates equipment condition assessment into the existing PRA and risk monitor framework to provide accurate and timely estimates of operational risk.

active and passive components↗

Ambient monitoring to inform the protection of beneficial uses and achieve water quality goals in Sinclair and Dyes Inlets, Puget Sound, WA

Currently discharge limits enforced under the Clean Water Act are focused on meeting water quality standards at the end of the pipe and environmental performance is measured based on meeting the discharge limits; but meeting discharge limits has very little to do with achieving water quality goals for coastal and estuarine ecosystems. Therefore, an effective monitoring and assessment program is needed to assess continuous process improvement, evaluate the ecological conditions, and provide metrics that can inform effective management of coastal and estuarine water quality. As part of an integrated Environmental Investment (ENVVEST) project for Sinclair and Dyes Inlets (ENVVEST 2006; Johnston et al. 2009) a network of monitoring stations was established to characterize environmental conditions, assess potential impacts, and establish environmental quality trends within the Inlets. Water, sediment, and biota monitoring locations were selected that were co-located near suspected sources (industrial, waste water, and stormwater outfalls; marinas, stream mouths, and other sources) or were representative of ambient marine and nearshore conditions. Water column stations and effluents from industrial outfalls were sampled seasonally for trace metals (Cd, Cr, Cu, Hg, Pb, and Zn) using analytical procedures appropriate for seawater (Strivens, Brandenberger and Johnston, 2018), conventional parameters (salinity, dissolved and total organic carbon, total and suspended solids, dissolved O2, pH, turbidity, NO2+NO3, NH4, N, and P), and toxicity. Effluent and water column toxicity tests included mysid shrimp (Americamysis bahia) 96 hr survival, sand dollar (Dendraster excentricus) or purple sea urchin (Strongylocentrotus purpuratus) 96 hr embryo development, QwikLite – dinoflagellate (Pyrocystis lunula) 24 hr bioluminescence response, mussel larvae (Mytilus sp.) 48 hr larvae survival and development, and kelp (Macrocystis pyrifera) 48 hr growth and germination. Additionally, indigenous mussels (Mytilis spp.) were sampled biennially for contaminant residues of metals, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), lipid content, and stable isotopes of C and N. The mussel data were compared to benchmarks of ecological effects (Johnston et al. 2007, Applied Biomonitoring 2009), samples obtained from a local seafood market harvested from Penn Cove on Whidbey Island (PKPLPC), and data from the national mussel watch status and trends monitoring program (Kimbrough et al. 2008). Results from 2009-2016 showed that dissolved metals nearly always met water quality standards and that water quality in Navy nearshore areas appeared to improve after best management practices (BMPs) for industrial process improvements (US Navy 2012) were completed in Sept. 2013 (Figure 1). In general, toxicity from exposure to whole effluent samples was not observed and ambient water samples were not toxic to test organisms, except that ambient toxicity was only observed during the presence of algal blooms which showed that toxicity was highly correlated with the abundance of the toxic algae Gymnodinium splendens (Rosen et al. 2009). Overall, mussel tissue residues were below benchmarks at most locations (Figure 2), however there were locations that had elevated levels of PAHs, PCBs, Hg, and Cu. Results from the monitoring provide metrics that are being used to assess progress toward meeting environmental quality goals for the watershed.

ENVVEST, PSEMP↗

Wastewater Treatment at the Fernald Preserve-Past, Present, and Future - 19555

Industrial wastewater treatment at the Fernald Preserve, Ohio, Site has been ongoing since a uranium metals refinery was constructed there at the beginning of the Cold War in 1951. Initially, the primary purpose of treatment was to recover uranium for reuse. Later, when cleanup of the site was progressing in the 1990's, wastewater treatment efforts greatly expanded. Large treatment facilities were constructed to handle contaminated surface water, groundwater, remediation wastewater, and leachate from the on-site disposal facility. These new facilities were designed to reduce uranium concentration to meet the US Environmental Protection Agency (EPA) drinking water standard and not generate large quantities of contaminated waste. Anion-exchange resin was chosen as the treatment media. The centerpiece of these facilities was the Advanced Wastewater Treatment facility, which had a treatment capacity of 10,978 liters per minute (lpm) (2900 gallons per minute [gpm]). Forecasts estimated that with the exception of groundwater the site's remediation would be completed in 2006. In 2003, the US Department of Energy (DOE) Office of Environmental Management began negotiations with the EPA and Ohio Environmental Protection Agency to reduce wastewater treatment capacity at the Fernald Environmental Management Project. These negotiations resulted in the site's treatment capacity being reduced to 6814 lpm (1800 gpm) via the Converted Advanced Wastewater Treatment facility (CAWWT). By 2010, the uranium concentration in the groundwater being pumped had been reduced to the degree that only intermittent treatment for uranium removal was needed. As a result, the CAWWT was considerably oversized. Increased maintenance on the aging CAWWT equipment led the DOE Office of Legacy Management (LM) to commission an assessment of the facility, which was completed in early 2015. The condition assessment identified numerous components at or near the end of their design life. Based on the assessment's findings and the fact that the current facility's treatment capacity was substantially greater than needed, LM began looking at options for an appropriately sized treatment system to handle the site's needs until the groundwater remediation was completed (currently projected for 2039). Options were evaluated in the spring of 2015, and LM presented the recommended changes to regulators and stakeholders. Approvals for a new, smaller system with a 189 lpm (50 gpm) capacity were obtained through a series of meetings in the summer of 2015. After more detailed planning in the fall of 2015, LM initiated the project in 2016. The project comprises the following four phases: (1) Removal and disposal of used media, piping, and tanks to make room for the new system in the existing building (completed in January 2017); (2) design of the new system (completed in April 2017); (3) construction, installation, and startup of the new system (completed in May 2018); and (4) backwash basin refurbishment (yet to be completed). In the late 2030's, when groundwater remediation is projected to be completed at the site, it is anticipated that the only remaining wastewater treatment need will be for small quantities of leachate from the on-site disposal facility. Results of leachate treatment testing in 2003 indicate it may be feasible to utilize a small passive treatment system for this leachate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

10 CFR 830 Major Modification Determination for Replacement of ATR Primary Coolant Pumps and Motors

The continued safe and reliable operation of the ATR is critical to the Department of Energy (DOE) Office of Nuclear Energy (NE) mission. While ATR is safely fulfilling current mission requirements, a variety of aging and obsolescence issues challenge ATR engineering and maintenance personnel’s capability to sustain ATR over the long term. First documented in a series of independent assessments, beginning with an OA Environmental Safety and Health Assessment conducted in 2003, the issues were validated in a detailed Material Condition Assessment (MCA) conducted as a part of the ATR Life Extension Program in 2007.Accordingly, near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent subprojects. The first project will replace the existent diesel-electrical bus (E-3), switchgear, and the 50-year-old obsolescent marine diesels with commercial power that is backed with safety related emergency diesel generators, switchgear, and uninterruptible power supply (UPS). The second project, the subject of this major modification determination, will replace the four, obsolete, original primary coolant pumps (PCPs) and motors. Completion of this and the two other age-related projects (replacement of the ATR diesel bus [E-3] and switchgear and replacement of the existent emergency firewater injection system) will resolve major age-related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues that lead to the conclusion that the project is a major modification: 1. Evaluation Criteria #3 (Change of existing process). The proposed strategy for equipping the replacement PCPs with VFDs and having the PCPs also function as ECPs will require significant safety basis changes requiring DOE approval. 2. Evaluation Criteria #4 (Use of new technology). The use of VFD and VFD “pump catcher” technology for the PCPs is not currently in use and has not been previously formally reviewed/approved by DOE for ATR. It is noted that VFD technology has several decades of commercial use and experience. However, the ATR probabilistic risk assessment will have to be updated, reflecting the changes for supplying ECP flows including VFD reliability, to confirm that the proposed activity maintains or reduces the CDF for the ATR. 3. Evaluation Criteria #5 (Create the need for new or revised safety SSCs). It is expected that the proposed activity will result in a revised list of safety-related SSCs. Specifically, as currently proposed, the existing ECPs will be deleted from the list. The PCPs and their associated components, picking up the ECP function, will be classified as safety-related active Seismic Category I.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

10 CFR 830 Major Modification Determination for Emergency Firewater Injection System Replacement

The continued safe and reliable operation of the ATR is critical to the Department of Energy (DOE) Office of Nuclear Energy (NE) mission. While ATR is safely fulfilling current mission requirements, a variety of aging and obsolescence issues challenge ATR engineering and maintenance personnel’s capability to sustain ATR over the long term. First documented in a series of independent assessments, beginning with an OA Environmental Safety and Health Assessment conducted in 2003, the issues were validated in a detailed Material Condition Assessment (MCA) conducted as a part of the ATR Life Extension Program in 2007.Accordingly, near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent sub-projects. The first project will replace the existent diesel-electrical bus (E-3), switchgear, and the fifty year old antiquated marine diesels with commercial power that is backed with safety-related emergency diesel generators (EDGs), switchgear, and uninterruptible power supply. The second project will replace the four, obsolete, original primary coolant pumps and motors. The third project, the subject of this major modification determination, will replace the current emergency firewater injection system (EFIS). The replacement water injection system will function as the primary emergency water injection system with the EFIS being retained as a defense-in-depth backup. Completion of this and the two other age-related projects (replacement of the ATR diesel bus (E-3) and switchgear and replacement of the existent aged primary coolant pumps and motors) will resolve major age-related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues that lead to the conclusion that the project is a major modification.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Assessment of CTF for Time-at-Temperature Applications

The US nuclear industry is interested in improving the economics of their fleet of light-water reactors (LWRs) by uprating US plants. One option being considered is to regain lost margin from overly conservative fuel safety limits. The current limit requires avoidance of critical heat flux (CHF) and prevents further operation of fuel that experiences a dry-out in boiling water reactors (BWRs) or departure from nucleate boiling (DNB) in pressurized water reactors (PWRs); however, it has been shown that temporary, mild dry-out of the fuel does not necessarily increase the risk of fuel failure during its normal anticipated operating life. Such mild dry-out or DNB events may occur during a plant anticipated operational occurrence (AOO), such as a locked rotor in a PWR or a pump trip in a BWR. The time-at-temperature (TAT) approach to regulating fuel operation aims to demonstrate that the fuel rod’s integrity is not challenged during such a mild transient that leads to CHF in which the fuel operates at an elevated temperature for a brief period of time. However, implementing this approach will require extensive fuel material experimental data, as well as supporting modeling and simulation (M&S) predictions, to ensure that the predicted fuel response during AOOs, with all applicable uncertainty considered, will not threaten the safety of the fuel during the transient or the remainder of its anticipated lifecycle. To address this need, a comprehensive effort is being proposed that includes generating cladding material data under TAT conditions, assessment of available code capabilities for TAT conditions, development of new mechanistic models, and demonstration of the M&S capabilities for AOOs of interest. This will require a joint effort between the Nuclear Energy Advanced Modeling and Simulation (NEAMS) and Advanced Fuels Campaign (AFC) programs, as well as close collaboration with nuclear industry stakeholders. The outcome of this collaboration will result in development and assessment of capabilities that can be used by the nuclear industry to support qualification of a TAT-based fuel failure criteria safety limit. This report focuses on the thermal hydraulics (T/H) modeling capabilities and summarizes currently available data for validating the T/H subchannel code CTF for TAT conditions, as well as preliminary assessment results of the code. The initial assessment also resulted in implementation of an alternative post-CHF heat transfer package, which has been shown to significantly improve accuracy. This report is not a final assessment and does not consider all available validation data; it is intended that a future assessment will more fully validate the code for this application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complexity and entropy representation for machine component diagnostics

The Complexity-entropy causality plane (CECP) is a parsimonious representation space for time series. It has only two dimensions: normalized permutation entropy and Jensen-Shannon complexity of a time series. This two-dimensional representation allows for detection of slow or rapid drifts in the condition of mechanical components monitored through sensor measurements. The CECP representation can be used for both predictive analytics and visual monitoring of changes in component condition. This method requires minimal pre-processing of raw signals. Furthermore, it is insensitive to noise, stationarity, and trends. These desirable properties make CECP a good candidate for machine condition monitoring and fault diagnostics. In this work we study the effectiveness of CECP on three rotary component condition assessment applications. We use CECP representation of vibration signals to differentiate various machine component health conditions for rotary machine components, namely roller bearing and gears. The results confirm that the CECP representation is able to detect, with high accuracy, changes in underlying dynamics of machine component degradation states. From class separability perspective, the CECP representation is able to generate linearly separable classes for the classification of different fault states. This classification performance improves with increasing signal length. For signal length of 16,384 data points, the fault classification accuracy varies from 90% to 100% for bearing applications, and from 85% to 100% for gear applications. We observed that the optimum parameter for CECP representating depends on the application. For bearing applications we found that embedding dimension D = 4, 5, 6, and embedding delay τ = 1, 2, 3 are suitable for good fault classification. For gear applications we find that embedding dimension D = 4, 5, and embedding delay τ = 1, 5 are suitable for fault classification.

47 OTHER INSTRUMENTATION↗

Oxygen Compatibility Assessment of Components and Systems

Fire hazards are inherent in oxygen systems and a storied history of fires in rocket engine propulsion components exists. To detect and mitigate these fire hazards requires careful, detailed, and thorough analyses applied during the design process. The oxygen compatibility assessment (OCA) process designed by NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) can be used to determine the presence of fire hazards in oxygen systems and the likelihood of a fire. This process may be used as both a design guide and during the approval process to ensure proper design features and material selection. The procedure for performing an OCA is a structured step-by-step process to determine the most severe operating conditions; assess the flammability of the system materials at the use conditions; evaluate the presence and efficacy of ignition mechanisms; assess the potential for a fire to breach the system; and determine the reaction effect (the potential loss of life, mission, and system functionality as the result of a fire). This process should be performed for each component in a system. The results of each component assessment, and the overall system assessment, should be recorded in a report that can be used in the short term to communicate hazards and their mitigation and to aid in system/component development and, in the long term, to solve anomalies that occur during engine testing and operation.

Stoltzfus, Joel↗

Strategy Developed for Selecting Optimal Sensors for Monitoring Engine Health

Sensor indications during rocket engine operation are the primary means of assessing engine performance and health. Effective selection and location of sensors in the operating engine environment enables accurate real-time condition monitoring and rapid engine controller response to mitigate critical fault conditions. These capabilities are crucial to ensure crew safety and mission success. Effective sensor selection also facilitates postflight condition assessment, which contributes to efficient engine maintenance and reduced operating costs. Under the Next Generation Launch Technology program, the NASA Glenn Research Center, in partnership with Rocketdyne Propulsion and Power, has developed a model-based procedure for systematically selecting an optimal sensor suite for assessing rocket engine system health. This optimization process is termed the systematic sensor selection strategy. Engine health management (EHM) systems generally employ multiple diagnostic procedures including data validation, anomaly detection, fault-isolation, and information fusion. The effectiveness of each diagnostic component is affected by the quality, availability, and compatibility of sensor data. Therefore systematic sensor selection is an enabling technology for EHM. Information in three categories is required by the systematic sensor selection strategy. The first category consists of targeted engine fault information; including the description and estimated risk-reduction factor for each identified fault. Risk-reduction factors are used to define and rank the potential merit of timely fault diagnoses. The second category is composed of candidate sensor information; including type, location, and estimated variance in normal operation. The final category includes the definition of fault scenarios characteristic of each targeted engine fault. These scenarios are defined in terms of engine model hardware parameters. Values of these parameters define engine simulations that generate expected sensor values for targeted fault scenarios. Taken together, this information provides an efficient condensation of the engineering experience and engine flow physics needed for sensor selection. The systematic sensor selection strategy is composed of three primary algorithms. The core of the selection process is a genetic algorithm that iteratively improves a defined quality measure of selected sensor suites. A merit algorithm is employed to compute the quality measure for each test sensor suite presented by the selection process. The quality measure is based on the fidelity of fault detection and the level of fault source discrimination provided by the test sensor suite. An inverse engine model, whose function is to derive hardware performance parameters from sensor data, is an integral part of the merit algorithm. The final component is a statistical evaluation algorithm that characterizes the impact of interference effects, such as control-induced sensor variation and sensor noise, on the probability of fault detection and isolation for optimal and near-optimal sensor suites.

Source record↗