Experimental Simulation of Turbine-Exhaust Oxygen Recovery

In some liquid-propellant rocket engines, the liquid-oxygen boost pump is driven by a turbine that is powered by high-pressure gaseous oxygen. Once it exits the turbine, this gaseous oxygen can be salvaged by injecting it into the subcooled liquid oxygen exiting the boost pump. If the main LOX pump is to function correctly under these circumstances, complete condensation of the gaseous oxygen must quickly follow its injection into the boost-pump discharge. The current investigation uses steam and water in a simple rig that allows the condensation process to be visualized and quantified. This paper offers dimensionless-parameter correlations of the data and trends observed.

Clark, Jim A.↗

Custom Unit Pump Design and Testing for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.

Schuller, Michael↗

Custom Unit Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, seal-less, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion, and restart capability under both ambient and vacuum conditions. The pump operated at 40 to 240 lbm/hr flow rate, 35 to 100 oF pump temperature, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test.

Schuller, Michael↗

Pump for delivering heated fluids

A thermomechanical pump particularly suited for use in pumping a warming fluid obtained from an RTG (Radioisotope Thermal Generator) through science and flight instrumentation aboard operative spacecraft is described. The invention is characterized by a pair of operatively related cylinders, each including a reciprocating piston head dividing the cylinder into a pressure chamber confining therein a vaporizable fluid, and a pumping chamber for propelling the warming fluid, and a fluid delivery circuit for alternately delivering the warming fluid from the RTG through the pressure chamber of one cylinder to the pumping chamber of the other cylinder, whereby the vaporizable fluid within the pair of pressure chambers alternately is vaporized and condensed for driving the associated pistons in pumping and intake strokes.

Sabelman, E. E.↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Pumped two-phase heat transfer loop

A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes several independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.

Edelstein, Fred↗

Pumped two-phase heat transfer loop

A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes a plurality of independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.

Edelstein, Fred↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Dual-module humidity pump for efficient air dehumidification: Demonstration and performance limitations

Condensation dehumidification in conventional air conditioning technologies is energy-intensive, accounting for up to 50% of building cooling energy used in some climates. Selective vacuum membrane dehumidification (VMD) is one of the leading alternative dehumidification technologies due to its potential for significant energy savings, and the “dual-module humidity pump” is one of the most promising VMD concepts. Here, this work is the first to provide experimental proof-of-concept for the dual-module humidity pump system and provides the first thermodynamic modeling framework that accounts for realistic steady-state operating limitations, both of which are lacking in the current literature. Additionally, this work is the first to provide a system design solution that overcomes practical challenges associated with air accumulation in the vacuum channels. The experimental results in this work show that the current prototype can remove up to 45% of the water vapor in the air stream, and the vapor pressure difference in the vapor rejection module needs to be approximately 2–4 times greater than that of the dehumidification module in order to maintain balanced mass transfer. The thermodynamic model applied to typical air conditioning conditions shows that the ideal dehumidification (latent) COPs can reach up to 40, but practical COPs are limited to approximately 10. Furthermore, the model shows that the overall energy efficiency increases as the membrane air selectivity increases, though this improvement gradually starts to diminish when the membrane selectivity is increased above 10,000.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high power spacecraft thermal management system

This paper describes the design and test results of an ammonia hybrid capillary pumped loop thermal control system. As a hytbrid, the system can operate as either a passive, capillary pumped loop, or, as a mechanically pumped system. The system is comprised of an evaporator section, a condenser section, 10 meters of liquid and vapor transport lines, a mechanical pump, and a reservoir. In the evaporator section, four capillary pumps are each integrated into three cold plates. The mechanical pump is installed in the liquid line and is in series with the capillary pumps. Testing has demonstrated that in the capillary pumped mode, the HPSTM can acquire and transport a total heat load of between 120 W and 24 kW, with a maximum heat flux density of 4.3 W/sq cm in the evaporator section. In the mechanically pumped configuration, a heat acquisition potential of 50 kW (9 W/sq cm heat flux density) has been demonstrated. The hybrid system still retains the proven capillary capabilities of temperature control, heat load sharing and fluid flow control between evaporator plates, rapid power cycling, and pressure priming recovery of deprimed evaporators.

Ku, J.↗

Superradiant Neutrino Lasers from Radioactive Condensates

Superradiance emerges from collective spontaneous emission in optically pumped gases, and is characterized by photon emission enhancements of up to $\frac{1}{4}$⁢𝑁 2 in an 𝑁 atom system. The gain mechanism derives from correlations developed within the decay medium rather than from stimulated emission as in lasing, so an analog of this process should be possible for fermionic final states. We introduce here the concept of superradiant neutrino emission from a radioactive Bose Einstein condensate, which can form the basis for a superradiant neutrino laser. A plausible experimental realization based on a condensate of electron-capture isotope 83 Rb could exhibit effective radioactive decay rates accelerated from 86.2 days to minutes in viably sized rubidium condensates of 10 6 atoms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermoelectric Integrated Membrane Evaporation Subsystem operational improvements

A three-man preprototype Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) has been developed to provide high quality water recovery from waste fluids on extended duration space flights. In the most recent effort, a number of improvements have been made to simplify subsystem operation and increase performance. These modifications include changes to the hollow fiber membrane evaporator, the condensing section of the thermoelectric heat pump, and the electronic controller logic and display. This paper describes the results of the test program that was conducted to evaluate the implemented improvements. In addition, an advanced design concept is discussed that will provide lower electrical power consumption, greater water production capacity, lower weight, and a smaller package than the present subsystem configuration.

Dehner, G. F.↗

Two-phase/two-phase heat exchanger analysis

A capillary pumped loop (CPL) system with a condenser linked to a double two-phase heat exchanger is analyzed numerically to simulate the performance of the system from different starting conditions to a steady state condition based on a simplified model. Results of the investigation are compared with those of similar apparatus available in the Space Station applications of the CPL system with a double two-phase heat exchanger.

Kim, Rhyn H.↗

Flow Boiling and Condensation Experiment Flight Hardware Development

The Flow Boiling and Condensation Experiment (FBCE) to be manifested on the International Space Station (ISS) consists of a fluid system and the associated electronics to provide for conditioning the test fluid (normal-PerFluorohexane or nPFH-C6F14) to the proper thermodynamic state prior to entering a test module, which can be interchangeable based on the science objectives. Two separate test modules have been manufactured for the FBCE, the Flow Boiling Module (FBM), which investigates flow boiling for a subcooled liquid, saturated liquid, or two phase mixture, and the Condensation Module Heat Transfer (CM-HT), which investigates condensation of a flowing saturated or superheated vapor. The test fluid heating is accomplished using the Bulk Heater Module (BHM), which heats the fluid to various states based on the demands of the currently installed test module. ISS Internal Thermal Control System (ITCS) water is utilized to cool the test fluid prior to entering the circulation pump, and is also utilized for cooling for condensation in CM-HT, for cooling of a camera in FBM. An adjustable pressure bellows-type accumulator is used to set the pressure at the inlet of the test section, but does not provide active pressure control during testing. The flow of the test fluid is achieved using a gear pump controlled by a coriolis flow meter, which also provides the flow rate measurement. Flow rates for the ITCS water loops are measured and controlled using coriolis flow meters with directly controlled proportional valves. During execution of FBCE operations, the FBM is scheduled to collect data for three months before being exchanged with CM-HT for another three month data collection run. In this work, we present the development of the flight hardware, the associated challenges experienced during the development such as packaging flight system hardware, and the lessons learned in overcoming the encountered challenges.

Guzik, Monica C.↗

The Capillary Pumped Loop (CPL) GAS experiment G-471

The Capillary Pumped Loop (CPL) experiment, 6-471 is a thermal control system with high density heat acquisition and transport capability. The CPL consists of two capillary pumped evaporators with integral heaters, a fluid loop charged with ammonia (NH3), a condenser plate (heat sink), and various control electronics. The purpose of the experiment is to demonstrate the capability of a capillary pumped system under zero gravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. A unique feature of the CPL is the capillary pumps, which contain no moving parts. Each pump contains a wick of porous material which is saturated with the working fluid (anhydrous ammonia). As heat is added to the fluid, it evaporates and travels to the condenser, thus transporting the heat (via the latent heat of vaporization) from the heat source to its sink at nearly a constant temperature. The evaporation process produces the pressure gradient or pumping action that circulates the fluid. This is the same principal that plants and trees use to transport water and nutrients from their roots to their leaves against gravity. The difference is that the CPL employs a closed system to return the fluid directly to the pumps, whereas "Mother Nature'' has an open system where the fluid is indirectly returned to the roots by condensation of water from the clouds in the form of rain. It should be noted that the CPL experiment was the first flight of a thermal control system of this type. It was also the first shuttle experiment from the Space Station Advanced Development Program.

Dan Butler↗

Champagne Heat Pump

The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

Jones, Jack A.↗

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗