Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “concurrent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Exploiting communication concurrency on high performance computing systems

Although logically available, applications may not exploit enough instantaneous communication concurrency to maximize hardware utilization on HPC systems. This is exacerbated in hybrid programming models such as SPMD+OpenMP. We present the design of a "multi-threaded" runtime able to transparently increase the instantaneous network concurrency and to provide near saturation bandwidth, independent of the application configuration and dynamic behavior. The runtime forwards communication requests from application level tasks to multiple communication servers. Our techniques alleviate the need for spatial and temporal application level message concurrency optimizations. Experimental results show improved message throughput and bandwidth by as much as 150% for 4KB bytes messages on InfiniBand and by as much as 120% for 4KB byte messages on Cray Aries. For more complex operations such as all-to-all collectives, we observe as much as 30% speedup. This translates into 23% speedup on 12,288 cores for a NAS FT implemented using FFTW. We also observe as much as 76% speedup on 1,500 cores for an already optimized UPC+OpenMP geometric multigrid application using hybrid parallelism.

97 MATHEMATICS AND COMPUTING↗

Are Lock-Free Concurrent Algorithms Practically Wait-Free?

Lock-free concurrent algorithms guarantee that some concurrent operation will always make progress in a finite number of steps. Yet programmers prefer to treat concurrent code as if it were wait-free, guaranteeing that all operations always make progress. Unfortunately, designing wait-free algorithms is generally a very complex task, and the resulting algorithms are not always efficient. Although obtaining efficient wait-free algorithms has been a long-time goal for the theory community, most nonblocking commercial code is only lock-free. This article suggests a simple solution to this problem. We show that for a large class of lock-free algorithms, under scheduling conditions that approximate those found in commercial hardware architectures, lock-free algorithms behave as if they are wait-free. In other words, programmers can continue to design simple lock-free algorithms instead of complex wait-free ones, and in practice, they will get wait-free progress. Our main contribution is a new way of analyzing a general class of lock-free algorithms under a stochastic scheduler. Our analysis relates the individual performance of processes to the global performance of the system using Markov chain lifting between a complex per-process chain and a simpler system progress chain. We show that lock-free algorithms are not only wait-free with probability 1 but that in fact a general subset of lock-free algorithms can be closely bounded in terms of the average number of steps required until an operation completes. Here, to the best of our knowledge, this is the first attempt to analyze progress conditions, typically stated in relation to a worst-case adversary, in a stochastic model capturing their expected asymptotic behavior.

97 MATHEMATICS AND COMPUTING↗

Developing strong concurrent multiphysics multiscale coupling to understand the impact of microstructural mechanisms on the structural scale

The heterogeneity in mechanical fields introduced by microstructure plays a critical role in the localization of deformation. To resolve this incipient stage of failure, it is therefore necessary to incorporate microstructure with sufficient resolution. On the other hand, computational limitations make it infeasible to represent the microstructure in the entire domain at the component scale. In this study, the authors demonstrate the use of concurrent multi- scale modeling to incorporate explicit, finely resolved microstructure in a critical region while resolving the smoother mechanical fields outside this region with a coarser discretization to limit computational cost. The microstructural physics is modeled with a high-fidelity model that incorporates anisotropic crystal elasticity and rate-dependent crystal plasticity to simulate the behavior of a stainless steel alloy. The component-scale material behavior is treated with a lower fidelity model incorporating isotropic linear elasticity and rate-independent J 2 plas- ticity. The microstructural and component scale subdomains are modeled concurrently, with coupling via the Schwarz alternating method, which solves boundary-value problems in each subdomain separately and transfers solution information between subdomains via Dirichlet boundary conditions. Beyond cases studies in concurrent multiscale, we explore progress in crystal plastic- ity through modular designs, solution methodologies, model verification, and extensions to Sierra/SM and manycore applications. Advances in conformal microstructures having both hexahedral and tetrahedral workflows in Sculpt and Cubit are highlighted. A structure-property case study in two-phase metallic composites applies the Materials Knowledge System to local metrics for void evolution. Discussion includes lessons learned, future work, and a summary of funded efforts and proposed work. Finally, an appendix illustrates the need for two-way coupling through a single degree of freedom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Scientific Case for Concurrent Neutron and X-ray Scattering and Spectroscopy

The interrogation of materials with X-rays or neutrons to determine the structure, energetics, and dynamics of materials is fundamental to advancing materials' physical and chemical science and developing innovative material technologies. A transcending challenge in developing novel materials is that progress hinges on understanding the structure and dynamics across multiple time and length scales in complex materials that feature multiple components, interfaces, and compositions. Despite the ever-growing demands on materials’ characterization, existing approaches are almost exclusively based on isolated X-ray or neutron scattering, i.e., an approach commensurate with the more narrowly defined needs of fifty years ago. A three-day workshop sponsored by the U.S. National Science Foundation (NSF) analyzed the demand for concurrent neutron and X-ray (NeX) experiments. It was held at the Spring Hill Suites, San Jose, California, from June 2 to 4, 2022. In this workshop, 70 national and international experts ascertained the crucial need to establish NeX capabilities to advance the science of complex materials and systems in the US. Here, we illustrate the need for NeX scattering and spectroscopy experiments by showcasing examples that span areas as diverse as biomaterials, energy science, soft matter, and nanomaterials. To provide NeX capability will require new instrumentation that enables concurrent experiments. Affected areas include chemistry, soft matter, quantum materials, pure and applied chemistry, bioscience, geoscience, and applied materials. NeX benefits research outcomes due to the complementarity of the two techniques, which is essential for better model refinement. While joint refinement of data from separate neutron and X-ray experiments is critical to avoid ambiguities, especially in multiphase-multicomponent materials, concurrent experiments overcome scientific and technical barriers associated with single measurements, separated by location and, thus, time. Among all the examples, these factors introduce uncertainties in the results that complicate data analysis. [1,2] [3] While models are strongly sample-dependent, the principles of joint refinement are generally applicable to these disciplines, including the development of advanced parameterization, modeling, and analysis techniques that also consider the temporal and spatial resolutions of the two methods, leading to unambiguous data interpretation. Solutions for technical barriers must be found to realize NeX experiments, including developing robust sample environments that meet the optical requirements of neutrons and X-rays.

36 MATERIALS SCIENCE↗

Performance of particle in cell methods on highly concurrent computational architectures

Particle in cell (PIC) methods are effective in computing Vlasov-Poisson system of equations used in simulations of magnetic fusion plasmas. PIC methods use grid based computations, for solving Poisson’s equation or more generally Maxwell’s equations, as well as Monte-Carlo type methods to sample the Vlasov equation. The presence of two types of discretizations, deterministic field solves and Monte-Carlo methods for the Vlasov equation, pose challenges in understanding and optimizing performance on today large scale computers which require high levels of concurrency. These challenges arises from the need to optimize two very different types of processes and the interactions between them. Modern cache based high-end computers have very deep memory hierarchies and high degrees of concurrency which must be utilized effectively to achieve good performance. The effective use of these machines requires maximizing concurrency by eliminating serial or redundant work and minimizing global communication. A related issue is minimizing the memory traffic between levels of the memory hierarchy because performance is often limited by the bandwidths and latencies of the memory system. This paper discusses some of the performance issues, particularly in regard to parallelism, of PIC methods. The gyrokinetic toroidal code (GTC) is used for these studies and a new radial grid decomposition is presented and evaluated. Scaling of the code is demonstrated on ITER sized plasmas with up to 16K Cray XT3/4 cores.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Concurrent conditions access across validity intervals in CMSSW

The CMS software system, known as CMSSW, has a generalized conditions, calibration, and geometry data products system called the EventSetup. The EventSetup caches results of reading or calculating data products based on the 'interval of validity', IOV, which is based on the time period for which that data product is appropriate. With the original single threaded CMSSW framework, updating only on an IOV boundary meant we only required memory for a single data product of a given type at any time during the program execution. In 2016 CMS transitioned to using a multi-threaded framework as away to save on memory during processing. This was accomplished by amortizing the memory cost of EventSetup data products across multiple concurrent events. To initially accomplish that goal required synchronizing event processing across IOV boundaries, thereby decreasing the scalability of the system. In this presentation we will explain how we used 'limited concurrent task queues' to allow concurrent IOVs while still being able to limit the memory utilized.

Dagenhart, David↗

Quality-of-Life-Adjusted Survival Analysis of Concurrent Chemo Radiotherapy for Locally Advanced (Nonmetastatic) Nasopharyngeal Cancer

Purpose: To assess whether the benefits of adding cisplatin (CDDP) concurrent with radiotherapy, followed by adjuvant CDDP and fluorouracil, justifies the toxicity cost for nasopharyngeal cancer (NPC) using the quality-adjusted time without symptoms or toxicity (Q-TWiST) approach. Methods and Materials: One hundred seven patients treated with radiotherapy (RT) and 111 with concurrent chemotherapy and radiotherapy (CRT) were analyzed. The overall survival was divided into three health states: time on active treatment only, during which any subjective nonhematologic toxic event of grade > = 3 was reported; time without symptoms of disease relapse; or treatment and time following first disease RELapse. The relative advantage of CRT and RT was examined by conducting the analysis cumulatively at restriction times 3, 6, 24, 36, 48 months. Results: At 48 months, the improvement in disease-free survival was 14.4% for CRT, whereas that for overall survival was 18.9%. The differences in Q-TWiST were -0.4, -0.7, 0.1, 1.6, and 3.6 months at 3, 6, 24, 36, and 48 months, respectively, with positive differences favoring CRT. At 24 months, the difference in Q-TWiST began to favor CRT. At 36 months, CRT may be the preferred option from the patient's viewpoint if the time spent in the REL state is valued to be <0.83, with the value of perfect health being 1. Finally, Q-TWiST accumulated within 48 months indicated a significant advantage in quality-adjusted survival time for CRT (p = 0.020). Conclusion: Irrespective of how patients valued periods of toxicity and delayed disease progression, concurrent chemotherapy and radiotherapy offered NPC patients significantly more quality-adjusted survival than radiotherapy alone in the long term.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multidisciplinary concurrent optimization framework for multi-phase building design process

Modern day building design projects require multidisciplinary expertise from architects and engineers across various phases of the design (conceptual, preliminary, and detailed) and construction processes. The Architecture Engineering and Construction (AEC) community has recently shifted gears toward leveraging design optimization techniques to make well-informed decisions in the design of buildings. However, most of the building design optimization efforts are either multidisciplinary optimization confined to just a specific design phase (conceptual/preliminary/detailed) or single disciplinary optimization (structural/thermal/daylighting/energy) spanning across multiple phases. Complexity in changing the optimization setup as the design progresses through subsequent phases, interoperability issues between modeling and physics-based analysis tools used at later stages, and the lack of an appropriate level of design detail to get meaningful results from these sophisticated analysis tools are few challenges that limit multi-phase multidisciplinary design optimization (MDO) in the AEC field. Here this paper proposes a computational building design platform leveraging concurrent engineering techniques such as interactive problem structuring, simulation-based optimization using meta models for energy and daylighting (machine learning based) and tradespace visualization. The proposed multi-phase concurrent MDO framework is demonstrated by using it to design and optimize a sample office building for energy and daylighting objectives across multiple phases. Furthermore, limitations of the proposed framework and future avenues of research are listed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the true power of bifacial perovskite solar cells under concurrent bifacial illumination

An accurate assessment of bifacial solar cells under concurrent bifacial illumination is critical to evaluate their real photovoltaic performance. Here, we demonstrate bifacial perovskite solar cells with bifacial equivalent power conversion efficiencies of 21% and 26% under concurrent bifacial illumination with an albedo of 0.2 and 0.5, respectively. A detailed balance efficiency limit analysis further reveals the full potential of bifacial perovskite solar cells.

14 SOLAR ENERGY↗

The scientific case for concurrent neutron and X-ray scattering and spectroscopy

The interrogation of materials with X-rays or neutrons to determine structure, energetics, and dynamics is fundamental to advancing physical and chemical materials science and enabling innovative material technologies. A persistent challenge in materials development is that progress depends on understanding structure and dynamics across multiple length and time scales in increasingly complex, multicomponent systems featuring interfaces, heterogeneity, and hierarchical organization. Despite rapidly growing demands on materials characterization, current experimental approaches are almost exclusively based on isolated X-ray or neutron scattering and spectroscopy, reflecting a paradigm largely unchanged for decades. To assess the scientific need for a new experimental paradigm, a 3-day workshop sponsored by the U.S. National Science Foundation (NSF) was held at the SpringHill Suites, San Jose, California, from June 2 to 4, 2022. The workshop brought together 70 national and international experts who critically evaluated opportunities enabled by concurrent neutron and X-ray (NeX) scattering, spectroscopy, and imaging experiments. The participants reached a clear consensus that establishing NeX capabilities is crucial for advancing the science of complex materials in the United States. This report illustrates the scientific drivers for NeX experiments through representative examples spanning biomaterials, energy materials, soft matter, nanomaterials, quantum materials, geoscience, and applied materials research. The complementarity of neutrons and X-rays is essential for robust model development and refinement, particularly in multiphase and multicomponent systems. While joint refinement of data from separate experiments is valuable, concurrent measurements uniquely eliminate uncertainties arising from sample evolution, environmental drift, and irreproducibility associated with experiments performed at different locations and times. Realizing NeX capabilities will require the development of new instrumentation, data analysis frameworks, and robust sample environments compatible with both neutron and X-ray probes. Addressing these challenges will enable unambiguous interpretation of complex materials behavior and open new frontiers in materials research.

X-ray↗

Critical Points Based Register-Concurrency Autotuning for GPUs

The unprecedented prevalence of GPGPU is largely attributed to its abundant on-chip register resources, which allow massively concurrent threads and extremely fast context switch. However, due to internal memory capacity constraints, there is a tradeoff between the per-thread register usage and the overall concurrency. This becomes a design problem in terms of performance tuning, since the performance “sweet spot” which can be significantly affected by these two factors is generally unknown beforehand. In this paper, we propose an effective autotuning solution to quickly and efficiently select the optimal number of registers perthread for delivering the best GPU performance. Experiments on three generations of GPUs (Nvidia Fermi, Kepler and Maxwell) demonstrate that our simple strategy can achieve an average of 10% performance improvement while a max of 50% over the original version without modifying the user program. Additionally, to reduce local cache misses due to register spilling and further improve performance, we explore three optimization schemes (i.e. bypass L1 for global memory access, enlarge local L1 cache and spill into shared memory) and discuss their impact on performance on a Kepler GPU.

auto-tuning↗

Concurrent Synthesis of High-Performance Monolayer Transition Metal Disulfides

To date, the chemical vapor deposition (CVD) approach has been widely used for the growth of transition metal dichalcogenides (TMDs). However, the reported CVD methods to synthesize TMDs cannot be used to grow more than one type of TMDs. This work reports a promising CVD technique to concurrently synthesize multiple monolayer transition metal disulfides once. The optoelectrical characterization and high-resolution transmission electron microscopy show the high quality of monolayer crystals, and, more importantly, there is no mixing between different precursors during the growth process, which has been investigated by considering the gas flow dynamics and concentration distribution of precursors in our setup. This strategy indicates the promising future for the batch production of 2D materials and the concurrent synthesis techniques in standard state-of-the-art complementary metal-oxide-semiconductor (CMOS) fabrication technology.

36 MATERIALS SCIENCE↗

Concurrent multiscale modeling of microstructural effects on localization behavior in finite deformation solid mechanics

The heterogeneity in mechanical fields introduced by microstructure plays a critical role in the localization of deformation. In order to resolve this incipient stage of failure, it is therefore necessary to incorporate microstructure with sufficient resolution. On the other hand, computational limitations make it infeasible to represent the microstructure in the entire domain at the component scale. Here, the authors demonstrate the use of concurrent multiscale modeling to incorporate explicit, finely resolved microstructure in a critical region while resolving the smoother mechanical fields outside this region with a coarser discretization to limit computational cost. The microstructural physics is modeled with a high-fidelity model that incorporates anisotropic crystal elasticity and rate-dependent crystal plasticity to simulate the behavior of a stainless steel alloy. The component-scale material behavior is treated with a lower fidelity model incorporating isotropic linear elasticity and rate-independent J 2 plasticity. The microstructural and component scale subdomains are modeled concurrently, with coupling via the Schwarz alternating method, which solves boundary-value problems in each subdomain separately and transfers solution information between subdomains via Dirichlet boundary conditions. In this study, the framework is applied to model incipient localization in tensile specimens during necking.

36 MATERIALS SCIENCE↗

A new apparatus for the concurrent measurement of friction and permeability evolution in fault gouge

Here we introduce a new miniature double direct shear (mini-DDS) apparatus, housed within a standard-triaxial (TEMCO) pressure vessel, capable of concurrently measuring the evolution of frictional strength, stability, healing and along-fault permeability under in situ conditions of stress and temperature. The apparatus accommodates gouge samples (25 mm × 32 mm) and intact rock samples with confining and shear stresses and pore pressures up to ~26 MPa. Permeability may be measured with applied flow rates ranging from 1.67 × 10 -11 to 3.6 × 10 -6 m 3 /s to a flow accuracy of 0.5% representing a lower bound of permeability >2.2 × 10 -18 m 2 . Sliding velocities are in the range 0.1 μm/s to 0.67 cm/s with a frame stiffness of 0.067 kN/μm. We describe protocols and procedures for calibration and experiments and note the potential of the apparatus for both rapid and extended-duration measurements of friction-permeability evolution and healing. The apparatus returns measurements of friction and stability of reference materials of F110 quartz consistent with the literature while additionally allowing the concurrent measurement of permeability. Permeability of F110 quartz evolves in slide-hold-slide (SHS) experiments with increases during holds and decreases during subsequent slides. These observations are consistent with grain crushing and resultant wear products that reduce that permeability by clogging during slides with unclogging of the major fluid channels occurring during shearing.

58 GEOSCIENCES↗

Efficacy and Factors Affecting Outcome of Gemcitabine Concurrent Chemoradiotherapy in Patients With Locally Advanced Pancreatic Cancer

Purpose: To evaluate the efficacy and prognostic factors of gemcitabine (GEM) concurrent chemoradiotherapy (CCRT) in patients with locally advanced pancreatic cancer. Methods and Materials: Between January 2002 and December 2005, 55 patients with locally advanced pancreatic cancer treated with GEM (400 mg/m{sup 2}/wk) concurrently with radiotherapy (median dose, 50.4 Gy; range, 26-61.2) at Taipei Veterans General Hospital were enrolled. GEM (1,000 mg/m{sup 2}) was continued after CCRT as maintenance therapy once weekly for 3 weeks and repeated every 4 weeks. The response, survival, toxicity, and prognostic factors were evaluated. Results: With a median follow-up of 10.8 months, the 1- and 2-year survival rate was 52% and 19%, respectively. The median overall survival (OS) and median time to progression (TTP) was 12.4 and 5.9 months, respectively. The response rate was 42% (2 complete responses and 21 partial responses). The major Grade 3-4 toxicities were neutropenia (22%) and anorexia (19%). The median OS and TTP was 15.8 and 9.5 months in the GEM CCRT responders compared with 7.5 and 3.5 months in the nonresponders, respectively (both p < 0.001). The responders had a better Karnofsky performance status (KPS) (86 {+-} 2 vs. 77 {+-} 2, p = 0.002) and had received a greater GEM dose intensity (347 {+-} 13 mg/m{sup 2}/wk vs. 296 {+-} 15 mg/m{sup 2}/wk, p = 0.02) than the nonresponders. KPS and serum carbohydrate antigen 19-9 were the most significant prognostic factors of OS and TTP. Conclusion: The results of our study have shown that GEM CCRT is effective and tolerable for patients with locally advanced pancreatic cancer. The KPS and GEM dose correlated with response. Also, the KPS and CA 19-9 level were the most important factors affecting OS and TTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Acute Esophagitis in Lung Cancer Patients Treated With Concurrent Three-Dimensional Conformal Radiotherapy and Chemotherapy

Purpose: To evaluate the risk factors for acute esophagitis (AET) in lung cancer patients treated with concurrent 3D-CRT and chemotherapy. Methods and Materials: Data from 100 patients treated with concurrent chemoradiotherapy with a mean dose of 62.05 {+-} 4.64 Gy were prospectively evaluated. Esophageal toxicity was graded according to criteria of the Radiation Therapy Oncology Group. The following dosimetric parameters were analyzed: length and volume of esophagus in treatment field, percentage of esophagus volume treated to {>=}10, {>=}20, {>=}30, {>=}35, {>=}40, {>=}45, {>=}50, {>=}55, and {>=}60 Gy, and the maximum (D{sub max}) and mean doses (D{sub mean}) delivered to the esophagus. Also, we developed an esophagitis index (EI) to account the esophagitis grades over treatment time. Results: A total of 59 patients developed AET (Grade 1, 26 patients; Grade 2, 29 patients; and Grade 3, 4 patients). V50 was associated with AET duration (p = 0.017), AET Grade 1 duration (p = 0.016), maximum analgesia (p = 0.019), esophagitis index score (p = 0.024), and AET Grade {>=}1 (p = 0.058). If V50 is <30% there is a 47.3% risk of AET Grade {>=}1, which increases to 73.3% if V50 is {>=}30% (p = 0.008). The predictive abilities of models (sensitivity and specificity) were calculated by receiver operating characteristic curves. Conclusions: According to the receiver operating characteristic curve analysis, the 30% of esophageal volume receiving {>=}50 Gy was the most statistically significant factor associated with AET Grade {>=}1 and maximum analgesia (A{sub max}). There was an association with AET Grade {>=}2 but it did not achieve statistical significance (p = 0.076)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Trial Using Proteasome Inhibitor Bortezomib and Concurrent Temozolomide and Radiotherapy for Central Nervous System Malignancies

Purpose: To evaluate the toxicity and response rate of bortezomib with concurrent radiotherapy and temozolomide in the treatment of patients with central nervous system malignancies. Patients and Methods: This open-label, dose-escalation, Phase I clinical study evaluated the safety of three dose levels of intravenously administered bortezomib (0.7, 1.0, and 1.3 mg/m{sup 2}/dose) on Days 1, 4, 8, and 11 of a 21-day cycle, in addition to concurrent radiotherapy and temozolomide at a daily dose of 75 mg/m{sup 2} starting on Day 1. The primary endpoint was dose-limiting toxicity, defined as any Grade 4-5 toxicity or Grade 3 toxicity directly attributable to protocol treatment, requiring hospitalization and/or radiotherapy interruption. The secondary endpoints included feasibility, non-dose-limiting toxicity, and treatment response. Results: A total of 27 patients were enrolled, 23 of whom had high-grade glioma (10 recurrent and 13 newly diagnosed). No dose-limiting toxicities were noted in any dose group, including the highest (1.3 mg/m{sup 2}/dose). The most frequent toxicities were Grade 1 and 2 stomatitis, erythema, and alopecia. All 27 patients were evaluable for response. At a median follow-up of 15.0 months, 9 patients were still alive, with a median survival of 17.4 months for all patients and 15.0 months for patients with high-grade glioma. Conclusion: Bortezomib administered at its typical 'systemic' dose (1.3 mg/m{sup 2}) is well tolerated and safe combined with temozolomide and radiotherapy when used in the treatment of central nervous system malignancies. A Phase II study to characterize efficacy is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Associated With Severe Acute Esophagitis From Hyperfractionated Radiotherapy With Concurrent Chemotherapy for Limited-Stage Small-Cell Lung Cancer

Purpose: To describe incidence and identify factors associated with development of severe acute esophagitis during hyperfractionated radiotherapy with concurrent chemotherapy (BID-CRT) in patients with limited-stage small-cell lung cancer (SCLC). Methods and Materials: Retrospective cohort analysis of patient-, tumor-, and treatment-related variables was performed to identify factors associated with Radiation Therapy Oncology Group (RTOG) Grade 3 acute esophagitis. Twice-daily chemoradiotherapy (BID-CRT) involved 45 Gy at 1.5 Gy per fraction, treated twice daily with concurrent platinum-based chemotherapy. Logistic regression analyses were used to identify factors associated with esophagitis. Results: Between June 1999 and June 2007, 48 patients underwent curative intent BID-CRT for SCLC and were included in the analysis. Median radiotherapy dose was 45 Gy (range, 42-51 Gy) delivered with a median 4 cycles of chemotherapy (range, 2-6). RTOG Grade 3 acute esophagitis developed in 11 patients. No patient developed Grade 4 or 5 esophagitis. Simple logistic regression analyses demonstrated a highly significant association between Grade 3 acute esophagitis and mean esophageal dose (p = 0.002) as well as relative volume dosimetric area under curve (RV-AUC; p = 0.004). Using multiple regression analysis, RV-AUC was identified as the only factor associated with Grade 3 esophagitis (p = 0.004). The most strongly associated dosimetric volume was the V15 (Grade 3 esophagitis rates of 15% vs. 64% for V15 <60% versus {>=}60%, respectively). Conclusions: RV-AUC is the factor most associated with development of Grade 3 acute esophagitis in limited stage SCLC patients receiving BID-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗