Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compute tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Computed Tomography Scanning and Geophysical Measurements of the Integrated Mid-Continent Stacked Carbon Storage Hub Sleepy Hollow Reagan Unit 86A Well

The Computed Tomography (CT) facilities, the Multi-Sensor Core Logger (MSCL), and the Geologic Storage Core Flow laboratory at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia and Pittsburgh, Pennsylvania were used to characterize a core through Upper Pennsylvanian strata (limestones, mudstones, and sandstones) from the Sleepy Hollow Reagan Unit (SHRU) 86A well in southwest-central Nebraska. The Integrated Mid-Continent Stack Carbon Storage Hub (IMSCS-HUB) core from the vertical well was obtained as part of the Department of Energy’s (DOE) effort to assess the feasibility of stacked storage complexes in Nebraska and Kansas to support a commercial-scale CO2 storage hub. The Sleepy Hollow Field (SHF) is one of three sites within the IMSCS-HUB corridor. Bulk scans of core were obtained from the IMSCS-HUB SHRU 86A well. This report, and the associated scans, include detailed datasets not typically made available to the public. The data sets presented in this report can be accessed from NETL's Energy Data eXchange (EDX) online system.

58 GEOSCIENCES↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Examination of Scanning Electron Microscope and Computed Tomography Images of PICA

Micrographs of PICA (Phenolic Impregnated Carbon Ablator) taken using a Scanning Electron Microscope (SEM) and 3D images taken with a Computed Tomography (CT) system are examined. PICA is a carbon fiber based composite (Fiberform ) with a phenolic polymer matrix. The micrographs are taken at different surface depths and at different magnifications in a sample after arc jet testing and show different levels of oxidative removal of the charred matrix (Figs 1 though 13). CT scans, courtesy of Xradia, Inc. of Concord CA, were captured for samples of virgin PICA, charred PICA and raw Fiberform (Fig. 14). We use these images to calculate the thermal conductivity (TC) of these materials using correlation function (CF) methods. CF methods give a mathematical description of how one material is embedded in another and is thus ideally suited for modeling composites like PICA. We will evaluate how the TC of the materials changes as a function of surface depth. This work is in collaboration with ETH-Zurich, which has expertise in high temperature materials and TC modeling (including CF methods).

Lawson, John W.↗

Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis

A software method has been developed that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography (CT). This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2D sheets (or flattened onion skins ) in addition to a series of top view slices and 3D volume rendering. The advantages of viewing the data in this fashion are as follows: (1) the use of standard and specialized image processing and analysis methods is facilitated having 2D array data versus a volume rendering; (2) accurate lateral dimensional analysis of flaws is possible in the unwrapped sheets versus volume rendering; (3) flaws in the part jump out at the inspector with the proper contrast expansion settings in the unwrapped sheets; and (4) it is much easier for the inspector to locate flaws in the unwrapped sheets versus top view slices for very thin cylinders. The method is fully automated and requires no input from the user except proper voxel dimension from the CT experiment and wall thickness of the part. The software is available in 32-bit and 64-bit versions, and can be used with binary data (8- and 16-bit) and BMP type CT image sets. The software has memory (RAM) and hard-drive based modes. The advantage of the (64-bit) RAM-based mode is speed (and is very practical for users of 64-bit Windows operating systems and computers having 16 GB or more RAM). The advantage of the hard-drive based analysis is one can work with essentially unlimited-sized data sets. Separate windows are spawned for the unwrapped/re-sliced data view and any image processing interactive capability. Individual unwrapped images and un -wrapped image series can be saved in common image formats. More information is available at http://www.grc.nasa.gov/WWW/OptInstr/ NDE_CT_CylinderUnwrapper.html.

Roth, Don J.↗

Development of X-Ray Computed Tomography Image Quality Indicators, "IQIs"

The intent of this effort, which is funded through the NASA OSMA NDE Program, is to develop a methodology and tools to assess Computed Tomography (CT) system performance. In particular, our team has fabricated Image Quality Indicators (IQIs) using materials and internal features useful for assessing CT detectability limits, contrast sensitivity, and resolution. Unlike traditional 2D radiography IQIs, those for CT should be more conducive to volumetric datasets and of uniform aspect ratio cross-sections.

Additive Manufacturing↗

Multihead Attention U‐Net for Magnetic Particle Imaging–Computed Tomography Image Segmentation

Magnetic particle imaging (MPI) is an emerging noninvasive molecular imaging modality with high sensitivity and specificity, exceptional linear quantitative ability, and potential for successful applications in clinical settings. Computed tomography (CT) is typically combined with the MPI image to obtain more anatomical information. Herein, a deep learning‐based approach for MPI‐CT image segmentation is presented. The dataset utilized in training the proposed deep learning model is obtained from a transgenic mouse model of breast cancer following administration of indocyanine green (ICG)‐conjugated superparamagnetic iron oxide nanoworms (NWs‐ICG) as the tracer. The NWs‐ICG particles progressively accumulate in tumors due to the enhanced permeability and retention (EPR) effect. The proposed deep learning model exploits the advantages of the multihead attention mechanism and the U‐Net model to perform segmentation on the MPI‐CT images, showing superb results. In addition, the model is characterized with a different number of attention heads to explore the optimal number for our custom MPI‐CT dataset.

Juhong, Aniwat↗

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Domain identification in impedance computed tomography by spline collocation method

A method for estimating an unknown domain in elliptic boundary value problems is considered. The problem is formulated as an inverse problem of integral equations of the second kind. A computational method is developed using a splice collocation scheme. The results can be applied to the inverse problem of impedance computed tomography (ICT) for image reconstruction.

Kojima, Fumio↗

LATTE: open-source, high-performance traveltime computation, tomography and source location in acoustic and elastic media

Traveltime-based tomography and source location are fundamental approaches for imaging subsurface structures and understanding the spatiotemporal distribution of seismicity from local to global scales. We present an open-source, high-performance framework integrating eikonal equation solvers and adjoint-state theory for traveltime computation, velocity tomography, source location and joint tomography-location in 2-D/3-D acoustic and elastic media. We introduce novel regularization schemes based on total generalized p-variation, structural similarity and multitask machine learning to enhance the fidelity and interpretability of inverted models and source locations. Key features of our implementation also include the ability to leverage both absolute-difference and double-difference traveltime misfits for high-fidelity velocity tomography and source parameter estimation; support for traveltime computation and inversion in diverse 2-D/3-D scenarios with arbitrary source and receiver distributions; and a perturbation-based optimal step-size estimation method to reduce computational costs. In addition, our implementation employs shared-memory and distributed-memory parallelization to provide an efficient solution for traveltime computation, tomography, and source location. In conclusion, we validate the efficacy and accuracy of our approach through multiple synthetic data examples.

58 GEOSCIENCES↗

Bimodal Visualization of Industrial X-Ray and Neutron Computed Tomography Data

Advanced manufacturing creates increasingly complex objects with material compositions that are often difficult to characterize by a single modality. Our collaborating domain scientists are going beyond traditional methods by employing both X-ray and neutron computed tomography to obtain complementary representations expected to better resolve material boundaries. However, the use of two modalities creates its own challenges for visualization, requiring either complex adjustments of bimodal transfer functions or the need for multiple views. Together with experts in nondestructive evaluation, we designed a novel interactive bimodal visualization approach to create a combined view of the co-registered X-ray and neutron acquisitions of industrial objects. Using an automatic topological segmentation of the bivariate histogram of X-ray and neutron values as a starting point, the system provides a simple yet effective interface to easily create, explore, and adjust a bimodal visualization. Here, we propose a widget with simple brushing interactions that enables the user to quickly correct the segmented histogram results. Our semiautomated system enables domain experts to intuitively explore large bimodal datasets without the need for either advanced segmentation algorithms or knowledge of visualization techniques. We demonstrate our approach using synthetic examples, industrial phantom objects created to stress bimodal scanning techniques, and real-world objects, and we discuss expert feedback.

image segmentation↗

In situ Visible Light and Thermal Imaging Data from a Laser Powder Bed Fusion Additive Manufacturing Process Co-Registered to X-ray Computed Tomography and Fatigue Data

This dataset is comprised of in situ sensing data collected during a laser-based powder bed fusion additive manufacturing process, as well as rasterized scan path information, post-build X-ray computed tomography (XCT), and fatigue test results. A total of 64 cylinders, approximately 15 mm in diameter and 102 mm tall, were printed out of stainless steel 316H on a Colibrium Additive Concept Laser M2 Series 5 machine. Parameters known to produce dense material were used to construct 56 of these cylinders, while the remaining 8 cylinders were printed with relatively high energy density parameters prone to producing keyhole pores. In addition, two spatter generation blocks were constructed upstream of the 64 cylinders such that ejecta produced during the melting of the spatter generators were stochastically seeded onto the 64 cylinders. Based on previous experiments, these spatter particles were theorized to produce stochastic lack-of-fusion pores. During the construction of the build, high-resolution images of reflected light in the visible spectrum were captured both before and after recoating for each print layer. Additionally, temporally integrated thermal imaging in the near infrared spectrum produced integrated sum and max images on a layerwise basis. The multimodal in situ data has been co-registered to the build plate coordinate system, allowing for identification of process anomalies (e.g., spatter particles) apparent in the two sensors. Following construction of the build, the cylinders were subjected to XCT to identify internal flaws, and the resulting data have also been registered to the build plate coordinate system. Finally, 60 of the 64 cylinders were machined into fatigue coupons conforming to ASTM E466 and subsequently subjected to either high- or -low-cycle fatigue testing. The results of the fatigue tests have also been included in the dataset, and the XCT data corresponded to the approximate location of the gauge sections of the machine fatigue specimen geometry.

42 ENGINEERING↗

Computed tomography for non-destructive evaluation of composites: Applications and correlations

The state-of-the-art fabrication techniques for composite materials are such that stringent species-specific acceptance criteria must be generated to insure product reliability. Non-destructive evaluation techniques including computed tomography (CT), X-ray radiography (RT), and ultrasonic scanning (UT) are investigated and compared to determine their applicability and limitations to graphite epoxy, carbon-carbon, and carbon-phenolic materials. While the techniques appear complementary, CT is shown to provide significant, heretofore unattainable data. Finally, a correlation of NDE techniques to destructive analysis is presented.

Goldberg, B.↗

Strategy to safely enable X-ray computed tomography examination of highly radioactive tristructural isotropic nuclear fuel

Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.

42 - ENGINEERING↗

Deep learning‑based metal artefact reduction in X-ray computed tomography of TRISO fuel compacts

TRISO (TRi-structural ISOtropic) – compact-type micro-particle fuels – are next generation nuclear fuel compacts designed with safety in mind. Structural integrity and characterisation before and after irradiation are important to determine the performance of the fuel compacts under real reactor conditions. X-ray computed tomography can be an important tool for non-destructive evaluation of these fuel compacts. The fuel particles are highly attenuating for X-rays which creates metal artefact, rendering the images unusable. Our artefact correction can mitigate these artefacts significantly. The proposed method works by first segmenting highly-attenuating structures (metal) and forward projecting to localise the source of artefacts in the projection domain, then, using a traditional or U-net-based deep learning architecture, contextually interpolating those regions to remove the artefacts. Finally the reconstruction from the modified projection is fused with the segmented metal. The proposed method shows a significant improvement in the image quality while significantly reducing the reconstruction time compared to the standard technique.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Computed Tomography Support for Microgravity Materials Science Experiments

The accurate measurement of density in both liquid and solid samples is of considerable interest to Principal Investigators with materials science experiments slated for the ISS. The work to be described is an innovative application of a conventional industrial nondestructive evaluation instrument. Traditional applications of industrial computed tomography (CT) rely on reconstructing cross sections of large structures to provide two-dimensional planar views which can identify defects such as porosity, or other material anomalies. This has been done on microgravity materials science experiments to check the integrity of ampoule-cartridge assemblies for safety purposes. With a substantially monoenergetic flux, as can be obtained with a radioactive cobalt source, there will be a direct correlation between absorption and density. Under such conditions it then becomes possible to make accurate measurements of density throughout a sample, and even when the sample itself is enclosed within a furnace and a safety required cartridge. Such a system has been installed at Kennedy Space Center (KSC) and is available to PIs to examine samples before and after flight. The CT system is being used to provide density information for two purposes. Firstly, the determination of density changes from liquid to solid is vital information to the PI for purposes of modeling the solidification behavior of his sample, and to engineers who have to design containment ampoules and must allow for shrinkage and other volume changes that may occur during processing. While such information can be obtained by pycnometric measurements, the possibility of using a furnace installed on the CT system enables one to examine potentially dangerous materials having high vapor pressures, while not needing visible access to the material. In addition, uniform temperature can readily be obtained, and the system can be controlled to ramp up, hold, and ramp down while collecting data over a wide range of parameters automatically. Results of initial tests on low melting point elements such as gallium, indium and tin will be presented, and the intent is to proceed to compounds such as InSb, HgCdTe and CdTe. Alloys such as Pb-Sb (PI - Poirier, U AZ) and Cu-Al (PI - Trivedi, Ames Lab.), which are the subjects of flight experiments, will also be examined. The second application is the conversion of measured density values directly to composition. This was successfully done with the mercury cadmium telluride alloys grown on the second and fourth United States Microgravity Payload (USMP-2 and USMP-4) missions by Lehoczky. CdTe values along the length of the boules were obtained at KSC prior to cutting the sample, and could have been obtained prior to its removal from the cartridge and ampoule. Examples of the data obtained will be shown. It is anticipated that several of the materials science PIs will avail themselves of the technique described, initially for determining densities prior to flight, and then to acquire early quantitative data on the compositional variation within their samples.

Gillies, Donald C.↗

High resolution computed tomography of advanced composite and ceramic materials

Advanced composite and ceramic materials are being developed for use in many new defense and commercial applications. In order to achieve the desired mechanical properties of these materials, the structural elements must be carefully analyzed and engineered. A study was conducted to evaluate the use of high resolution computed tomography (CT) as a macrostructural analysis tool for advanced composite and ceramic materials. Several samples were scanned using a laboratory high resolution CT scanner. Samples were also destructively analyzed at the locations of the scans and the nondestructive and destructive results were compared. The study provides useful information outlining the strengths and limitations of this technique and the prospects for further research in this area.

Yancey, R. N.↗

Quantifying Void Ratio Variation in Sand using Computed Tomography

A series of displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses in a microgravity environment aboard the Space Shuttle during the NASA STS-89 mission. Post-flight analysis included studying the internal fabric and failure patterns of these specimens using Computed Tomography (CT). The CT scans of three specimens subjected to different compression levels (uncompressed specimen, a specimen compressed to 3.3% nominal axial strain (epsilon(sub a)), and a specimen compressed to 25% epsilon(sub a)) are presented to investigate the evolution of instability patterns and to quantify void ratio variation. The progress of failure is described and discussed. Also, specimens' densities were calibrated using standard ASTM procedures and void ratio spatial variation was calculated and represented by contour maps and histograms. The CT technique demonstrated good ability to detect specimen inhomogeneities, localization patterns, and quantifying void ratio variation within sand specimens.

Alshibli, Khalid A.↗