Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “command and control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hybrid DS/FFH Spread-Spectrum: A Robust, Secure Transmission Technique for Communication in Harsh Environments

Spread-spectrum modulation techniques have been adopted for many current and future military communication systems to accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A more recent synergistic combination is a direct-sequence spread-spectrum (DSSS) signaling with the use of integrally coordinated frequency hopping (FH) and/or time-hopping (TH) modulation, generically dubbed hybrid spread-spectrum (HSS). A highly useful form of this transmission scheme for many types of command, control, and sensing applications is the specific code-related combination of standard DSSS modulation with "fast" frequency hopping (FFH), wherein multiple frequency hops occur within a single data-bit time. In this paper, detailed error-probability analyses are performed for a hybrid DS/FFH system over standard Gaussian and fading-type channels, progressively including the effects from wide-band, partial-band, and follow-on jamming, multi-user interference and/or varying degrees of Rayleigh and Rician fading. In addition, a simulation-based study of the DS/FFH performance is performed and compared to several forms of existing standard DSSS and FHSS wireless networks. The parameter space of HSS is also explored to further demonstrate the adaptability of the waveform for varied harsh RF signal environments.

99 GENERAL AND MISCELLANEOUS↗

Apparatus and method for modifying the operation of a robotic vehicle in a real environment, to emulate the operation of the robotic vehicle operating in a mixed reality environment

Apparatus and methods for modifying the operation of a robotic vehicle in a real environment to emulate the operation of the robotic vehicle in a mixed reality environment include a vehicle sensing system having a communications module attached to the robotic vehicle for communicating operating parameters related to the robotic vehicle in a real environment to a simulation controller for simulating the operation of the robotic vehicle in a mixed (live, virtual and constructive) environment wherein the affects of virtual and constructive entities on the operation of the robotic vehicle (and vice versa) are simulated. These effects are communicated to the vehicle sensing system which generates a modified control command for the robotic vehicle including the effects of virtual and constructive entities, causing the robot in the real environment to behave as if virtual and constructive entities existed in the real environment.

42 ENGINEERING↗

Determining System Parameters for Optimal Performance of Hybrid DS/FFH Spread-Spectrum

In recent years there has been great interest in using hybrid spread-spectrum (HSS) techniques for commercial applications, particularly in the Smart Grid, in addition to their use in military communications because they accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this transmission technique for many types of command, control, and sensing applications is the specific code-related combination of standard direct sequence (DS) modulation with "fast" frequency hopping (FFH), denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper, an optimization problem is formulated that maximizes the DS/FFH communication system performance in terms of probability of bit error and solves for the system design parameters. The objective function is non-convex and can be solved by applying the Karush-Kuhn-Tucker conditions. System design parameters of interest are the length of the DS code sequence, number of frequency hopping channels, number of channels corrupted by wide-band jamming, and number of hops per bit. The proposed formulation takes into account the effects from wide-band and partial-band jamming, multi-user interference and/or varying degrees of Rayleigh and Rician multipath fading. Numerical results are presented to demonstrate the method s viability.

direct sequence↗

Design, Implementation, and Evaluation of a Hybrid DS/FFH Spread-Spectrum Radio Transceiver

In recent years there has been great interest in using hybrid spread-spectrum (HSS) techniques for commercial applications, particularly in the Smart Grid, in addition to their inherent uses in military communications. This is because HSS can accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this transmission technique for many types of command, control, and sensing applications is the specific code-related combination of standard direct-sequence modulation with "fast" frequency-hopping, denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper, we present the efforts carried out at Oak Ridge National Laboratory toward exploring the design, implementation, and evaluation of a hybrid DS/FFH spread-spectrum radio transceiver using a single Field Programmable Gate Array (FPGA). The FPGA allows the various subsystems to quickly communicate with each other and thereby maintain tight synchronization. We also investigate various hopping sequences against robustness to interference and jamming. Experimental results are presented that show the receiver sensitivity, radio data-rate/bit-error evaluations, and jamming and interference rejection capabilities of the implemented hybrid DS/FFH spread-spectrum system under widely varying design parameters.

data rate↗

MAVNet: Design of a Reliable Beyond Visual Line of Sight Communication System for Unmanned Vehicles

This paper details the design and system components of the Multi-Modal Autonomous Vehicle Network system (MAVNet). MAVNet was designed to provide reliable and redundant command, control and payload data distribution for unmanned vehicles operating beyond visual line of sight. Current industry solutions do not adequately solve key networking challenges, do not support network diversity and fall short of providing desirable next-generation requirements including data fusion from national air space data sources, multi-pilot and multi-agent control. The MAVNet system and the approach taken to solve these issues will be detailed in this paper.

Stinson, Brad J↗

Cloud-based control for power distribution system

Unique systems, methods, techniques and apparatuses for cloud-based control for power distribution systems are disclosed. One exemplary embodiment is a system comprising a microprocessor-based power management system in operative communication with a plurality of buildings located remotely from the power management system and a plurality of communication interface devices provided at corresponding ones of the plurality of buildings. The power management system is structured to perform a plurality of building unit-specific optimizations, evaluate a net power demand on the electrical power grid, reduce the net power demand on the electrical power grid while minimizing disruption to the resident-defined preference parameters, and transmit to each of the plurality of interface devices the one or more additional control commands corresponding to the specific building at which each interface device is provided.

Feng, Xiaoming↗

Systems and methods for controlling electrical grid resources

The present invention relates to PMU-based control systems for dampening inter-area oscillations in large-scale interconnected power systems or grids to protect against a catastrophic blackout. The control systems receive phasor measurements from two or more locations on an AC transmission line and generates a power control command to a power resource on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Science Federation Emulation Testbed: Demonstration of VFSIE Functionalities

The Virtual Federated Science Instrument Environment (VFSIE) is a digital twin of a federated infrastructure of multiple sites with science instruments and computing systems that are geographically dispersed. It emulates the federation using containers and virtual hosts (vhosts) connected over local and wide-area networks for the main purpose of supporting the development and testing of science workflows and software stacks, which will subsequently transition to the physical infrastructure. In this demo, we present VFSIE of a four sites scenario and illustrate the following use cases: (i) execution of federation stack components that expose resources to enable a science user to execute workflows, (ii) execution of remote control commands of beam-line instruments to collect measurements and position the sensor, and (iii) remote execution and access of Jupyter Notebook for tomographic image computations

Al Najjar, Anees↗

The Case for Modular Redundancy in Large-Scale High Performance Computing Systems

Recent investigations into resilience of large-scale high-performance computing (HPC) systems showed a continuous trend of decreasing reliability and availability. Newly installed systems have a lower mean-time to failure (MTTF) and a higher mean-time to recover (MTTR) than their predecessors. Modular redundancy is being used in many mission critical systems today to provide for resilience, such as for aerospace and command \& control systems. The primary argument against modular redundancy for resilience in HPC has always been that the capability of a HPC system, and respective return on investment, would be significantly reduced. We argue that modular redundancy can significantly increase compute node availability as it removes the impact of scale from single compute node MTTR. We further argue that single compute nodes can be much less reliable, and therefore less expensive, and still be highly available, if their MTTR/MTTF ratio is maintained.

99 GENERAL AND MISCELLANEOUS↗

Malware Analysis Report for SolarWinds.Orion.Core.BusinessLayer.dll

SolarWinds Orion is a software suite designed to provide “single pane of glass” monitoring of network devices and applications. On December 13 2020, FireEye revealed that SolarWinds Orion was the victim of a supply chain attack and that the SolarWinds signed file SolarWinds.Orion.Core.BusinessLayer.dll contained a backdoor. SolarWinds deployed the back-doored patch to customers beginning in March 2020. FireEye first identified this backdoor and labeled it SUNBURST. The backdoor is composed of roughly 4,000 lines1 of lightly obfuscated .NET within the SolarWinds.Orion.Core.BusinessLayer.OrionImprovementBusinessLayer class of the malicious dll. The backdoor’s capabilities include: the ability to detect and potentially disable antivirus and forensics tools, basic command and control via DNS, and more advanced command and control via HTTP.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Introduction to the Minitrack on Monitoring, Control, and Protection.

This minitrack is on topics related to the monitoring, control, and protection of electric power systems for real-time operations and short-term operations planning. This year the emphasis has been on recent developments in the area of large-scale dynamic research for power systems and on hybrid and distributed control concepts for decentralized command and control of existing critical energy infrastructures.

Eto, Joseph H↗

Massively parallel hierarchical control system and method

An electronic control system is disclosed for controlling individually controllable elements of an external component. In one embodiment the system may include a state translator subsystem for receiving a state command from an external subsystem. The state translator subsystem may have at least one module for processing the state command and generating operational commands for controlling the elements to achieve a desired state or condition. A programmable calibration command translation layer (PCCTL) subsystem may be included which receives and uses the operational commands to generate granular level commands for controlling the elements. A feedback control layer subsystem may be included which applies the granular level commands to the elements, and further modifies the granular level commands as needed to control the elements in closed loop fashion.

Panas, Robert Matthew↗

Autonomous Intelligent Assembly Systems LDRD 105746 (Final Report)

This report documents a three-year to develop technology that enables mobile robots to perform autonomous assembly tasks in unstructured outdoor environments. This is a multi-tier problem that requires an integration of a large number of different software technologies including: command and control, estimation and localization, distributed communications, object recognition, pose estimation, real-time scanning, and scene interpretation. Although ultimately unsuccessful in achieving a target brick stacking task autonomously, numerous important component technologies were nevertheless developed. Such technologies include: a patent-pending polygon snake algorithm for robust feature tracking, a color grid algorithm for uniquely identification and calibration, a command and control framework for abstracting robot commands, a scanning capability that utilizes a compact robot portable scanner, and more. This report describes this project and these developed technologies.

Anderson, Robert J.↗

Control circuits for asynchronous circuits

The described embodiments include a computing device with one or more asynchronous circuits and control circuits that control the operation of the asynchronous circuits. In some embodiments, the control circuits are arranged in a hierarchy with a top-level control circuit atop the hierarchy and one or more local control circuits lower in the hierarchy. In these embodiments, the top-level control circuit processes operating information for the one or more asynchronous circuits and/or other functional blocks in the computing device to determine an operating state for the computing device. Based on the operating state, the top-level control circuit communicates commands to the local control circuits to cause the local control circuits to operate in corresponding operating modes. Based on a corresponding operating mode command, each local control circuit sets one or more operating parameters for corresponding asynchronous circuits (and/or one or more other functional blocks).

42 ENGINEERING↗

Considerations for recovery of large areas of a nuclear facility for re-use - 15147

This paper highlights a number of factors an organization might consider for recovery of a facility, using a successful example from the UK. In 2013 a power failure led to the shutdown of the ventilation system that caused loose contamination to be deposited over large sections of man-accessible areas of plant after the evacuation of personnel. The successful initiation of emergency Command and Control arrangements during the Response phase, saw several key responders brought together to offer technical direction across many disciplines. The actions of the Command and Control unit prevented any further spread contamination to other areas of the facility and any external release. This enabled the return of the plant to an operational status which forms an important mission enabler for the site hazard reduction programme. Intervention at an early stage during the Response phase of the incident saw the cessation of traditional dilute chemical wet decontamination approach that would otherwise leave a legacy of slow leaching contamination; to that of containment and ultimate removal of loose contamination using strippable coatings. Doing so established a more rapid and reliably 'clean' access or pathway into the plant to establish the full extent of the situation. The scale and scope of the decontamination requirement was steadily revealed through a number of controlled re-entries to the plant. A number of other techniques were considered and employed to address the different areas making use of available plant resources to deliver the successful 'self-help' recovery of the plant using multi-disciplinary teams. As Response switched to Recovery, it was important to set out and agree which strategic option should be adopted to return the facility to normal operation. Equally, it was necessary to verify which equipment had been affected by the power outage and repair as required. Furthermore, equipment with designated safety functions had to be maintained alongside the Recovery activities. A careful balance of priorities demanded an unparalleled depth of plant knowledge to address this, whilst still keeping site and external stakeholders informed. The engagement by the plant workforce to take on the decontamination challenge to enable recovery of their plant supported by other teams formed a critical step in the speed of recovery. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

Nuclear Testing and the Joint Task Force System

During the 1940s, 50s, and early 60s, the United States conducted eight nuclear test operations in the far reaches of the Pacific Ocean. These operations were possible only because of a military command and control organization, the joint task force. Commanded by the Army Navy, and Air Force on a rotating basis, each of the seven JTFs provided the means by which the thousands of ships, planes, material, and personnel were moved over thousands of miles of ocean. The first task force, JTF-1, was created to test the destructive effects of the Fat Man bomb on Naval vessels at Bikini Atoll in the summer of 1946. Commanded by Vice Admiral William “Spike” Blandy, JTF-1 was a purely military operation supported by the MED. Never meant to be a permanent organization, JTF-1 was dissolved soon after completing its mission.

99 GENERAL AND MISCELLANEOUS↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗