Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Dual Column Tracer Experimental Results

Argonne National Laboratory (Argonne) is assisting Morgridge Institute for Research (MIR) in their efforts to develop SHINE (Subcritical Hybrid Intense Neutron Emitter), which is an accelerator-driven process that will use a uranyl-sulfate solution for the production of Mo-99. An integral part of the process is the development of a dual column for the recovery of Mo-99 from an irradiated target solution. Argonne has collected data from batch studies and small-scale column experiments to input into VERSE (Versatile Reaction Separation), which was developed by Dr. Linda Wang at Purdue University, to design large-scale separation processes using data obtained on a much smaller scale. Plant-scale column designs have been generated for the initial Mo-recovery column and the concentration column, which has been added to reduce strip volume prior to entry into the LEU-Modified Cintichem purification process. Direct downscale column experiments have been performed using 1 g of linac-irradiated DU (depleted uranium) foils as a spike for a uranyl-sulfate solution. The strip solution from the initial recovery column was used as a spike for a pH 2 sodium nitrate solution, which served as the feed solution for the concentration column.

Youker, Amanda J.↗

Wall-Friction Support of Vertical Loads in Submerged Sand and Gravel Columns

Laboratory studies of the ‘floor-loads’ under submerged vertical columns of sand and/or gravel indicate that such loads can be approximated by a buoyancy-corrected Janssen-silo-theory-like relationship. Similar to conditions in storage silos filled with dry granular solids, most of the weight of the sand or gravel is supported by wall friction forces. Laboratory measurements of the loads on the floor at the base of the water-filled columns (up to 25-diameters tall) indicate that the extra floor-load from the addition of the granular solid never exceeded the load that would exist under an unsupported (wide) bed of submerged sand or gravel that has a total depth corresponding to only two column-diameters. The measured floorloads reached an asymptotic maximum value when the depth of granular material in the columns was only three or four pipe-diameters, and never increased further as the columns were filled to the top (e.g. up to heights of 10 to 25 diameters). The floor-loads were stable and remained the same for days after filling. Aggressive tapping (e.g. hitting the containing pipe on the outside, manually with a wrench up and down the height and around the circumference) could increase (and occasionally decrease) the floor load substantially, but there was no sudden collapse or slumping to a state without significant wall friction effects. Considerable effort was required, repeatedly tapping over almost the entire column wall periphery, in order to produce floor-loads that corresponded to the total buoyancy-corrected weight of granular material added to the columns. Projecting the observed laboratory behavior to field conditions would imply that a stable floor-load condition, with only a slightly higher total floor pressure than the preexisting hydrostatic-head, would exist after a water-filled bore-hole is filled with sand or gravel. Significant seismic vibration (either a large nearby event or many micro-seismic events over an extended period) would likely be necessary before the full (buoyancy-corrected) weight of the sand and/or gravel would be ‘delivered’ to the bottom of the submerged column.

42 ENGINEERING↗

Device-scale CFD study for mass transfer coefficient and effective mass transfer area in packed column

Carbon dioxide (CO 2 ) is a significant contributor of greenhouse gases emissions responsible for global warming. The fossil-fueled power plant is one of the major sources of CO 2 emission worldwide and needs to be mitigated. Post-combustion carbon capture by chemical absorption can be a promising technology to reduce CO 2 emission from power plants. The absorption is carried out via countercurrent flow in the packed columns. Although monoethanolamine (MEA) is a popular solvent, it has also limitations such as high volatility of solvent, corrosivity that leads to product degradation and damage to apparatuses, low CO 2 loading capacity, etc. Therefore, alternate solvents are being explored as prospective materials for carbon capture. A water-lean solvent, CO 2 binding organic liquids (CO2BOL), is currently being developed as a prospective material in carbon capture at the Pacific Northwest National Laboratory. Since the development of the material is at the primitive stage, it needs extensive investigation before industrial deployments. Hydrodynamics and mass transfer phenomena in the packed column using CO 2 BOL is unknown. Computational fluid dynamics (CFD) can be a useful tool to understand these phenomena in the packed column. Before employing the extensive CFD investigations, one needs to carefully validate CFD predictions for accurate flow predictions. This report demonstrates the validation of multiphase flow simulations against the experimental results for both structured and random packed columns. The reactive multiphase flow simulations using volume of fluid method were conducted at a wide range of liquid loads and contacts angles. The effective area is one of the critical factors dictating interphase mass transfer due to chemical reactions. Accordingly, CFD-predicted effective areas were compared with the experimental results of Tsai et al. [1] for Mellapak 250.Y structured packing. Both results matched well at different liquid loads in the presence of fast chemical kinetics using caustic solvents. Further, reactive multiphase flow simulations were also conducted in pall ring random packing to compute effective areas in the presence of fast chemical reactions. The CFD-predicted effective area compared well with correlation developed by Song et al. [2]. With successful validations, the current simulation framework can be further used for prediction of hydrodynamics and mass transfer phenomena using CO 2 BOL solvents in the packed column. Subsequently, it would be helpful in design optimization of a packed column. In addition to validation of the CFD model, this report also explains the mechanism for enhanced liquid side mass transfer for a structured packed column as compared to the wetted wall column.

20 FOSSIL-FUELED POWER PLANTS↗

Investigation of countercurrent flow profile and liquid holdup in random packed column with local CFD data

Liquid holdup and mass transfer area are critical parameters used in packed column design and CO 2 capture efficiency prediction. Compared to experimental methods, 3D computational fluid dynamics (CFD) can provide high-resolution data for studying countercurrent flow hydrodynamics in a packed column. In this paper, a framework was established for modeling the liquid–gas countercurrent flow in a random packed column with pall rings. Besides the column-averaged information, the radial pall ring distribution, velocity, and liquid holdup profiles are obtained in the simulations. The radial two-phase velocity and liquid holdup profiles show significant fluctuations caused by the non-uniform pall ring distribution. The entrance effect and wall influence are also observed in the packed column. By using local countercurrent flow information, the packing specific area $a_p$ and liquid velocity $u_L$ range are significantly expanded for liquid holdup hL prediction. This enables us to develop the liquid holdup correlation with one packing size and six CFD runs only. The proposed power law of the liquid holdup correlation $h_L~u_L^{0.44}$ indicates the random packed column falls in a viscous to turbulent transition regime with a Reynolds Number range of [6.7–40.2]. The derived liquid holdup correlation is in good agreement with existing correlations that are developed using the column-averaged experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of the influence of the heat generated by viscous friction on the efficiency of chromatography columns

The combination of the heat balance in a chromatographic column percolated by a stream of mobile phase and of the model of band migration under linear conditions along such a column permits the calculation of the axial and radial temperature distributions in the column, of the elution band profiles, and of the column efficiency under different sets of experimental conditions. The calculated results are always consistent with the experimental results published by different groups and often in good quantitative agreement. Minor discrepancies arise from difficulties in deriving precise estimates of the heat transfers from the column due to the massive endfittings of the column and to uncontrolled heat transfer from the column tube to ambient air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A protocol for the measurement of all the parameters of the mass transfer kinetics in columns used in liquid chromatography

Band broadening in chromatography results from the combination of the dispersive effects that are associated with the different steps involved in the migration of compound bands along the column. These steps include longitudinal diffusion, trans-particle mass transfer, external film mass transfer, overall eddy diffusion, including trans-column, short-range inter-channel, trans-channel eddy diffusion, and the possible, additional mass transfer contributions arising from heat friction and the thermal heterogeneity of the column. We describe a series of experiments that provide the data needed to determine the coefficients of the contributions to band broadening of each one of these individual mass transfer steps. This specifically designed protocol can provide key information regarding the kinetic performance of columns used in liquid chromatography and explain why different columns behave so differently. The limitations, accuracy and precision of these methods are discussed. Further avenues of research that could improve the characterization of the mass transfer mechanisms in chromatographic columns, possibly contributing to the development of better columns, are suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of thermal processes in very high pressure liquid chromatography for column immersed in a water bath: Application of the selected models

Currently, chromatographic analyses are carried out by operating columns packed with sub-2 {micro}m particles under very high pressure gradients, up to 1200 bar for 5 cm long columns. This provides the high flow rates that are necessary for the achievement of high column efficiencies and short analysis times. However, operating columns at high flow rates under such high pressure gradients generate a large amount of heat due to the viscous friction of the mobile phase stream that percolates through a low permeability bed. The evacuation of this heat causes the formation of significant or even large axial and radial gradients of all the physico-chemical parameters characterizing the packing material and the mobile phase, eventually resulting in a loss of column efficiency. We previously developed and successfully applied a model combining the heat and the mass balances of a chromatographic column operated under very high pressure gradients (VHPLC). The use of this model requires accurate estimates of the dispersion coefficients at each applied mobile phase velocity. This work reports on a modification of the mass balance model such that only one measurement is now necessary to accurately predict elution peak profiles in a wide range of mobile phase velocities. The conditions under which the simple equilibrium-dispersive (ED) and transport-dispersive (TD) models are applicable in VHPLC are also discussed. This work proves that the new combination of the heat transfer and the ED model discussed in this work enables the calculation of accurate profiles for peaks eluted under extreme conditions, like when the column is thermostated in a water bath.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMPARISONS OF CRYSTALLINE SILICOTITANATE AND RESORCINOL FORMALDEHYDE MEDIA FOR CESIUM REMOVAL BY IN-TANK COLUMN PROCESSING

Chemical and thermal performance of crystalline silicotitanate (CST) and resorcinol-formaldehyde (RF) ion exchange media were predicted for column configurations designed for installation in high level waste tanks and intended for cesium removal from radioactive waste supernates. Modeling predictions for the processing of a known Savannah River Site tank waste composition were generated. In a two column configuration under presumed nominal operating conditions (432 gallon packed bed, 10 gpm liquid flow, 25 C, 45 nCi/g average breakthrough limit) with lead/lag column rotation between processing cycles, approximately two cycles were predicted to treat 1,000,000 gallons of radioactive waste with CST as compared to three cycles predicted for RF. However, this processing mode was shown to be highly unfavorable for RF due to the fact that the lead column is unnecessarily exposed to large radiation doses during movement of the cesium mass transfer zone into the lag column. Thermal modeling calculations indicated that maximum temperatures within stagnant, packed CST and RF columns containing the highest anticipated cesium loading and no active cooling will reach 128 and 78 C, respectively, within 6 days. Active cooling maintains the cesium-saturated CST and RF columns below 88 and 41 C, respectively, under stagnant flow conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A RISING COOL COLUMN AS A SIGNATURE OF HELICAL FLUX EMERGENCE AND FORMATION OF PROMINENCE AND CORONAL CAVITY

Continuous observations were performed of a quiescent prominence with the Solar Optical Telescope on board the Hinode satellite on 2006 December 23 and 24. A peculiar slowly rising column of {approx}10{sup 4} K plasma develops from the lower atmosphere during the observations. The apparent ascent speed of the column is 2 km s{sup -1}, while the fine structures of the column exhibit much faster motion of up to 20 km s{sup -1}. The column eventually becomes a faint low-lying prominence. An overlying coronal cavity associated with the appearance of the column seen in the X-ray and EUV moves upward at {approx}5 km s{sup -1}. We discuss the relationship between these episodes and suggest that they are due to the emergence of a helical flux rope that undergoes reconnection with lower coronal fields, possibly carrying material into the coronal cavity. Under the assumption of the emerging flux scenario, the lower velocity of 2 km s{sup -1} and the higher one of 20 km s{sup -1} in the column are attributed to the rising motion of the emerging flux and to the outflow driven by magnetic reconnection between the emerging flux and the pre-existing coronal field, respectively. The present paper gives a coherent explanation of the enigmatic phenomenon of the rising column with the emergence of the helical rope and its effect on the corona. We discuss the implications that the emergence of such a helical rope has on the dynamo process in the convection zone.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE OF CONTRIBUTION OF INTERVENING CLOUDS TO GAMMA-RAY BURST'S X-RAY COLUMN DENSITY

The origin of excess of X-ray column density with respect to optical extinction in gamma-ray bursts (GRBs) is still a puzzle. A proposed explanation of the excess is the photoelectric absorption due to the intervening clouds along a GRB's line of sight. Here, we test this scenario by using the intervening Mg II absorption as a tracer of the neutral hydrogen column density of the intervening clouds. We identify a connection between the large X-ray column density (and large column density ratio of log (N{sub H,X}/N{sub H{sub I}})∼0.5) and large neutral hydrogen column density probed by the Mg II doublet ratio (DR). In addition, GRBs with large X-ray column density (and large ratio of log (N{sub H,X}/N{sub H{sub I}})>0) tend to have multiple saturated intervening absorbers with DR < 1.2. These results therefore indicate an additional contribution from the intervening system to the observed X-ray column density in some GRBs, although the contribution from the host galaxy alone cannot be excluded based on this study.

79 ASTRONOMY AND ASTROPHYSICS↗

Plant-Scale Concentration Column Designs for SHINE Target Solution

Argonne is assisting Morgridge Institute for Research (MIR) in their efforts to develop SHINE, an accelerator-driven process that will utilize a uranyl-sulfate solution for the production of fission product Mo-99. An integral part of the process is the development of a column for the separation and recovery of Mo-99 followed by a concentration column to reduce the product volume from 15–25 L to less than 1 L. Argonne has collected data from batch studies and breakthrough column experiments to utilize the VERSE (Versatile Reaction Separation) simulation program (Purdue University) to design plant-scale product concentration processes. Plant-scale columns for 2, 4, and 6 hr loading times were designed for separation of Mo-99 from 130 g-U/L uranyl-sulfate solution. The Mo-99 product solution volumes from the recovery of Mo-99 from 260 L of uranyl sulfate are 23.5, 17.6, and 14.5 L for the 2, 4, and 6 hr loadings, respectively; the resulting Mo concentration in 0.1-M NaOH is 2.34 × 10 -2 , 3.13 × 10 -2 , and 3.81 × 10 -2 mM, respectively. The resulting product can be acidified to pH 2 using nitric acid and passed through a concentration column to reduce volume to less than 1 L. Concentration column designs have been generated for each of the three process scenarios (2, 4, and 6 hr). The plant-scale concentration column designs assume loading temperature of 80°C.

Stepinski, Dominique C.↗

Final Technical Report: Moving ASR Cloud Microphysical Retrievals Beyond the Vertical Column

Clouds of all types play important roles in atmospheric heating, surface heating and emission of radiation, hence energy, to space. Clouds not only affect atmospheric heating via their impacts on solar and terrestrial radiation, they also release kinetic energy to the atmosphere when they form and they extract kinetic energy from the atmosphere when they evaporate. To understand the impacts of clouds on weather and climate, one must be able to make accurate observations of the amount of water associated with them and the impact of this water on atmospheric and surface heating rates. One important cloud type is liquid water clouds. Liquid clouds are often found in the boundary layers of Earth at altitudes from just above the surface to approximately 2000 m above it, at a variety of temperatures, including temperatures below the freezing point of liquid water (0 °C). As a result, they are important constituents over the world’s oceans as well as over cold, ice-covered surfaces such as in the Arctic. Observationally estimating the total amount of liquid contained in a column through a liquid water cloud can now be accomplished to acceptable accuracies (except for the thinnest, lowest liquid containing clouds) using instruments called passive microwave radiometers. However, observationally determining the spatial distribution of liquid within these columns has proven to be difficult. The focus of this project was on the application of two radars operating at two different frequencies to retrieve the distribution of liquid water within columns passing through liquid water clouds. Motivation in this project for using two different radars operating at different frequencies is that as overlapping (in space) beams from the two radars pass through the same column of liquid water cloud absorption of power from one beam (the 94-GHz beam) is greater than absorption of power from the other beam (the 35-GHz beam). Therefore, the difference in returned powers between the two radar beams with distance from the radars is proportional to the amount of liquid water that the two beams have passed through. Therefore, one can use the differences in power between the two beams with distance through a liquid water cloud to determine the distribution of liquid water throughout the cloud. The two radars used in this study are the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Program Ka-band Scanning ARM Cloud Radar (Ka-SACR) and the W-band Scanning ARM Cloud Radar (W-SACR). When this projected started in 2013, the Ka- and W-band SACRs were new technology, state-of-the-art sensors. To put together a sufficiently diverse and big set of test cases for the study, data from the SACRs deployed to NSA, SGP, TCAP and MAGIC were used, leading to a test set composed of 65 hours of suitable data spread over approximately 17 case study days. Using the Ka- and W-band SACR data from the case study periods, vertical distributions of liquid water content through liquid water clouds were retrieved. Because there are no other data sets with which to compare the retrievals, distributions of liquid water through a column were summed and compared to the total amounts of liquid water obtained by retrievals applied to passive microwave radiometer observations. The total amounts of liquid water (in units of millimeters, or the thickness in millimeters of the total liquid water in a vertical column if allowed to pool at the bottom of the column) between the two retrievals agreed to within 0.060 mm with a standard deviation of 0.31 mm, or to within 0.016 mm with a standard deviation of 0.12 mm once outliers were removed. The standard deviation of 0.12 mm was fairly independent of the total amount of liquid water in the clouds, indicating that retrieval errors were larger for clouds with smaller amounts of liquid in them. Errors in the retrieved total amounts of liquid were also found to be sensitive to the a priori information that was fed into the retrieval approach. Overall, standard deviations of 0.12 mm are sufficient for some cloud studies but for radiation studies standard deviations on the order of 0.02 mm need to be achieved for clouds with the lowest amounts of liquid water. Many modifications to the retrieval approach were tested subsequently in an attempt to reduce the standard deviations relative to the radiometer retrievals below 0.12 mm but none of them worked reliably. We decided to wait until the DOE ARM Program deployed its second generation SACR2s to its NSA and ENA sites for further retrieval evaluation. The SACR2s were engineered to better synchronize data between the Ka- and W-band radars, reducing potential sources of noise for radar retrieval of liquid water distributions within clouds. The SACR2s have improved in reliability recently and the system deployed to ENA is best positioned to provide the data to advance research on this path. This will be an ongoing research activity beyond the project because of the promise in SACR2 data from the DOE ARM ENA Facility.

58 GEOSCIENCES↗

Chromatographic Modeling of 1-Foot Detritiation Test Column Results for the Optimization of Regeneration Time

This report documents the methods and results of a modeling study on a series of data generated by 1-foot test columns for the Water Detritiation project. In order to compliment modeling work already in progress on this project, a purely empirical curve-fitting approach is used in this study to determine chromatographic performance indicators such as retention time, curve width, and the number of chromatographic stages. The data used in this study comes from four sets of chromatographic test separations performed in March through May of 2017 using 1-foot columns. All are using the same flow rates and temperature (room temperature, nominally 25 C°). The first set of data (referred to in this report as the Column 1 data) is a series of twelve breakthrough curve measurements. Prior to each of these twelve runs, the column was regenerated by flowing hydrogen gas through the column, for increasing amounts of time, ranging from 2 hours to 25 hours. The second set of data (referred to as the Column 2 data) is comprised of five measurements of breakthrough curves measured in similar fashion as the Column 1 data, across a range of regeneration times from 2 to 21 hours. The third set of data (referred to as the Purge data) is of three breakthrough curves, measured after a regeneration time of 8 hours, which takes place after a nitrogen purge of 15, 30, or 45 minutes. The fourth data set is a series of five breakthrough curve measurements using a 2 nd batch of stationary phase, taken after regeneration times ranging from 2 to 20 hours. The overall modeling approach is as follows. First, the data is pre-processed for formatting, artifact removal, and is normalized. The data is then fit by integrated versions of four common chromatographic models. The best model is chosen based on the predictive performance of the model, and chromatographic performance values are calculated based on the best model’s fit parameters. Each of these processes are detailed below.

42 ENGINEERING↗

Multiphase computational fluid dynamics modeling of reacting flows in absorption columns for carbon capture

First-principles derived computational fluid dynamics (CFD) simulations have been proposed as a fundamental tool for investigating solvent-based CO 2 absorption in packed columns due to their ability to accurately represent the underlying nonlinear, multiscale dynamics. Numerous studies have previously utilized such CFD simulations to investigate hydrodynamics of columns with structured and random packings by assessing the key hydrodynamic metrics such as the interfacial and wetted areas. While mapping such metrics for different conditions is essential to the optimization of absorption columns, it is not sufficient, as the CO 2 capture rate depends also on the coupled, nonlinear dynamics from the underlying chemical reaction kinetics, thermodynamics, and heat-transfer rates. In this work, we present detailed CFD simulation results augmented by incorporating the effects of interfacial physical mass transfer of CO 2 , heat release from chemical reaction kinetics, and thermophysical property variations from resulting temperature gradients. We demonstrate the applicability of the proposed approach in numerically assessing the performance of packed columns by evaluating key hydrodynamic quantities, CO 2 absorption rates, and temperature rise in a reference column with packings that are structurally similar to the Sulzer Mellapak™ 250.Y packing, for different solvent inflow velocities and temperatures. Predictions from simulation results are found to be consistent with the trends in experimental observations from the literature, suggesting that the predictive capabilities of the simulation framework can be leveraged to guide the future development of absorber-column designs and optimized process flowsheets.

Absorption columns↗

Reproducible automated renewable column generation

Preparation of chromatographic columns requires considerable time during chemical separation procedures. Automated systems capable of repeatedly generating renewable, uniformly packed columns would find widespread use in analytical laboratories. Here, a fully automated commercial-off-the-shelf (COTS) system was utilized to pack and unpack 1 mL TEVA and UTEVA columns. To accurately determine the reproducibility of the resin load per column, studies were conducted over several weeks. Method optimization yielded an improvement in loading from 15–19% to 3–5% relative standard deviation. Furthermore, availability of automated COTS equipment capable of reproducibly generating separation columns has the potential to reduce time and costs associated with column separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Installation of the Pulse-Plate Column Pilot Plant

There are three primary types of solvent extraction equipment utilized in the nuclear industry for reprocessing of used nuclear fuel; pulse columns, mixer-settlers, and centrifugal contactors. Considerable research and development has been performed at the INL and throughout the DOE complex on the application of centrifugal contactors for used fuel reprocessing and these contactors offer many significant advantages. However, pulse columns have been used extensively in the past in throughout the world for aqueous separations processes and remain the preferred equipment by many commercial entities. Therefore, a pulse-plate column pilot plant has been assembled as part of the Advanced Fuel Cycle Initiative to support experimentation and demonstration of pulse column operation. This will allow the training of personnel in the operation of pulse columns. Also, this capability will provide the equipment to allow for research to be conducted in the operation of pulse columns with advanced solvents and processes developed as part of the fuel cycle research and development being performed in the AFCI program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Complete temperature profiles in ultra-high pressure liquid chromatography columns

The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C{sub 18} particles, average d{sub p} {approx} 1.7 {micro}m) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than {+-}0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.

36 MATERIALS SCIENCE↗

Influence of the Physical Properties of Liquids and Diameter of Bubble on the Formation of Liquid Column at the Interface of Two Liquid Phases by the Rising Bubble

The formation of metal emulsion in a steel-making process enhances the reaction between metal and slag. A part of the metal emulsion is formed by a bubble passing through the interface between the metal and slag phases. In a previous study, it was determined that the formation of metal column by the bubble is related to the formation of metal droplets. In this research, the effects of bubble particle size, interfacial tension, viscosity of upper layer, and lower layer density on the formation of lower liquid column were investigated. In order to conduct an in situ observation of gas and liquid behaviors, aqueous solution and silicon oil systems were employed. It was determined that a narrow and elongated column forms liquid droplets in the upper liquid layer and contributes to the formation of droplets. The height of the column and the volume of droplets increase with the increase in bubble size. The influence of interfacial tension of the two liquid phases on the column height and the formation of droplet is slight. The height of the formed column decreases with the increase in the density of lower liquid.

36 MATERIALS SCIENCE↗